36C26119B0031-002.pdf

PDF 14 MB Posted

Attached to
640-16-114 Replace Building 100 & 101 Flooring Repair Federal contract opportunity
Solicitation number
36C26119B0031
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 21

About this file

This notice provides information regarding an upcoming solicitation for flooring repair and replacement services at two Department of Veterans Affairs buildings in Palo Alto, California. The solicitation will seek bids to furnish all labor, materials, equipment, and supervision to repair and replace flooring on four floors of Buildings 100 and 101 at the VA Palo Alto Health Care System campus. The period of performance is expected to be 480 days after notice to proceed. The magnitude of construction is estimated between $2 million and $5 million. The solicitation will be set aside for Service-Disabled Veteran-Owned Small Businesses and issued on or around May 24, 2019 through the Federal Business Opportunities website. Bids will be due 30 days after issuance unless an extension is provided through amendment.

36C26119B0031 20181220 Package 1_Part1.pdf

View the file

Other files for this federal contract opportunity

Other files attached to 640-16-114 Replace Building 100 & 101 Flooring Repair, newest first.
File Type Posted
36C26119C0122-000.docx DOCX document
36C26119B0031-0005000.docx DOCX document
36C26119B0031-0004001.pdf PDF
36C26119B0031-0004000.docx DOCX document
36C26119B0031-0003001.pdf PDF
36C26119B0031-0003000.docx DOCX document
36C26119B0031-0002000.docx DOCX document
36C26119B0031-0001000.docx DOCX document
36C26119B0031-007.docx DOCX document
36C26119B0031-010.docx DOCX document
36C26119B0031-004.pdf PDF
36C26119B0031-003.pdf PDF
36C26119B0031-006.pdf PDF
36C26119B0031-008.docx DOCX document
36C26119B0031-005.doc DOC document
36C26119B0031-009.docx DOCX document
36C26119B0031-001.docx DOCX document
36C26119B0031-000.docx DOCX document
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REPLACE BUILDING 100/101 FLOORING REPAIR

VA PALO ALTO HEALTH CARE SYSTEM

3801 Miranda Avenue, Palo Alto, CA

DVA Project Number: 640-16-114 MEI Project Number: 227

PACKAGE #1: B100 / B101 FLOORING AND TOILET ROOMS

CONSTRUCTION DOCUMENTS 100% SUBMITTAL

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

COVER SHEET

G0-1

100 / 101

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMMMC

100% SUBMITTAL

AS2-1 DRAWING NUMBER

DISCIPLINE PREFIX

GROUP NUMBER

A

(E) COLUMN LINE W/

COLUMN DESIGNATIONS

DOOR SYMBOL

DOOR MARK

HARDWARE GROUP

WINDOW TYPE1i

AS9-1

AS5-1

AS3-1

DETAIL

DETAIL IDENTIFICATION

SHEET WHERE DETAIL IS SHOWN

INTERIOR ELEVATION(S)

ELEVATION IDENTIFICATION

(UNFOLD ELEVATIONS CLOCKWISE)

SHEET WHERE ELEVATION IS SHOWN

SECTION

SECTION IDENTIFICATION

SHEET WHERE SECTION IS SHOWN

REVISION

CLOUD AROUND REVISION

OPTIONAL

ROOM NAME

ROOM IDENTIFICATION, TYPE 1

3RD NO.-CEILING

2ND NO.-WALLS / WAINSCOT

ROOM MATERIAL CODES

ROOM NUMBER

1ST NO.-FLOOR / BASE

ROOM NAME

ROOM IDENTIFICATION, TYPE 2

ROOM NUMBER

TYPICAL FURRING OR

PARTITION TYPE, SEE DWG. AS9-

1A1i

SOUND TREATED PARTITION

W/ ACOUSTICAL INSULATION

EXISTING WALL / PARTITION /

FURRING TO REMAIN

EXISTING ONE-HOUR FIRE

RESISTIVE COMPARTMENT

SEPARATION WALL /

PARTITION TO REMAIN

DIMENSION LINES

. CENTERLINE OF COLUMN

OR STUD

FACE OF FINISH F.O.F.

CENTERLINE OF OPENING

CENTERLINE OF OPENING

AREAS WHERE NO WORK

TO BE DONE

EXISTING DOOR TO

REMAIN

EXISTING WALL OR

PARTITION TO BE REMOVED

DOOR TO BE REMOVED

INTERIOR WINDOW

REGISTER, EXHAUST OR

RETURN

SUPPLY DIFFUSER

RECESSED MOUNTED

LIGHTING FIXTURE

RECESSED MOUNTED

LIGHTING FIXTURE

EXIT SIGN

ROOM NAME

ROOM IDENTIFICATION, TYPE 3

ROOM NUMBER

+ 9' - 0" CEILING HEIGHT, A.F.F.

EXISTING TWO-HOUR FIRE

RESISTIVE COMPARTMENT

SEPARATION WALL /

PARTITION TO REMAIN

EXISTING WALL / PARTITION /

FURRING TO REMAIN, CUT

AND REMOVE (E) FINISH AS

REQUIRED FOR NEW

CONSTRUCTION, (E) STUDS

TO REMAIN

ACCESS PANEL11

A.1

1.1

(N) COLUMN LINE W/

COLUMN DESIGNATIONS

SYMBOLS U.O.N.

ROOM NAME

A1 1

ROOM NAME

ROOM NAME

RECESSED MOUNTED

LINEAR LIGHTING FIXTURE

CONCRETE

EARTH

GYPSUM BOARD

BATT INSULATION

RIGID INSULATION

MEDIUM DENSITY FIBERBOARD

ALUMINUM

STUCCO

PLYWOOD

WOOD

PLASTER

STEEL

MATERIALS U.O.N. ABBREVIATIONS

TYP.

THRES.

S.

RM.

R.H.

REINF.

REQ.

REF.

STD.

SIM.

SHR.

THK.

T.B.

T.C.

TEL.

STOR.

STRL.

STL.

N.I.C.

NO. or #

N.T.S.

N.R.

OPNG.

OPP.

O.F.C.I

O.A.

O.C.

PLYWD.

PT.

PL.

QTY.

PTN.

VERT.

V.I.F.

W.C.

WD.

W/O

W.

W/

WP.

N.

U.O.N.

CEM.

DWG.

CONC.

CONT.

CORR.

CPT.

CTSK.

CNTR.

CLG.

CLO.

CLR.

CER.

DET.

DIA.

DIM.

DN.

DR.

CTR.

ADJ.

A.F.F.

ARCH.

(N)

A.B.

ADD.

(E)

BLKG.

BM.

BOT.

CAB.

BD.

BLDG.

MTD.

INC.

INFO.

HGT.

INT.

JT.

INSUL.

H.C.

MIN.

MISC.

MAX.

KIT.

LAB.

or H.

EA.

EQ.

EXT.

F.A.

F.D.

FDN.

FIN.

FIXT.

EL.

FPRF.

FLUOR.

F.O.F.

F.O.S.

FL.

E.

L

ACOUST.

A.P.

BKG.

BLK.

C.G.

C.J.

COL.

CONSTR.

DISP.

E.J.

ELEC.

ELEV.

ENCL.

ENGR.

E.P.B.

EQPT.

EXP.

E.W.C.

F.E.

F.E.C.

F.H.C.

FT.

F.S.

HDWD.

H.M.

HORIZ.

HR.

I.D.

LAM.

LT.

MAT.

MECH.

MET.

MFR.

NOM.

O.D.

OFF.

O.H.

P. LAM.

PR.

P.T.D.

RAD.

REFR.

RGTR.

RESIL.

R.O.

SCHED.

SECT.

SHT.

S.C.

SPEC.

SQ.

S.ST.

SUSP.

T.P.B.

VEST.

W.O.

WT.

W.R.

M.D.F.

(RL)

C.O.

E.B.

EMER.

EXST.

HDWE.

GYP.

GA.

GALV.

G.B.

GL.

DVA

Vertical

Noted

Wood

West With

Unless Otherwise

Verify In Field

Without

Water Closet

Waterproof

Typical

Threshold

Robe Hook

Top of Curb

Reinforced Required

Room

Reference

Standard

Similar

Shower

South

Storage

Towel Bar

Telephone

Structural

Thick

Steel

Not In Contract

Not To Scale

Owner (Government or VA) Furnished, Contractor Installed

Number

On Center

Opening Opposite

Overall

Non Rated

Plywood

Partition

Quantity

Point

Plate

North

Cement

Drawing Mounted

Ceiling Closet Clear

Concrete

Continuous Corridor

Ceramic

Carpet

Countersunk

Counter

Detail Diameter Dimension

Down Door

Center

Insulation

Height

Incandescent Information

Hollow Core

Interior

Joint

Maximum

Minimum

Kitchen

Laboratory

Miscellaneous

Each

At Centerline

Existing New

Adjustable

Architectural

Board

Building

Blocking Beam

Anchor Bolt

Additional

Bottom

Cabinet

Above Finished Floor

Equal

Exterior

Elevation

Finish Fixture

Fire Alarm Floor Drain Foundation

Fluorescent Face of Finish Face of Studs Fireproof

Floor

And

East

Diameter

Angle

Acoustical

Access Panel

Backing

Block

Corner Guard Construction Joint

Column

Construction

Dispenser

Expansion Joint

Electrical Elevator

Enclosure Engineer Electrical Panelboard

Equipment

Expansion Electric Water Cooler

Fire Extinguisher Fire Extinguisher

Fire Hose Cabinet

Foot or Feet Floor Sink

Hardwood

Hollow Metal Horizontal Hour

Inside Diameter

Laminate Light

Material

Mechanical Metal Manufacturer

Nominal

Outside Diameter Office Opposite Hand

Plastic Laminate

Pair

Paper Towel

Radius

Refrigerator Register

Resilient

Rough Opening

Schedule Section

Sheet

Solid Core

Specification Square Stainless Steel

Suspended

Telephone

Vestibule

Where Occurs

Weight Water Resistant

Medium Density

Relocated Existing

U.O.N.

Pound or Number

Cased Opening

Expansion Bolt

Emergency

Existing

Hardware

Gypsum

Gauge Galvanized Grab bar Glass

Cabinet

Fiberboard

Dispenser

Panelboard

Department of Veterans Affairs

CL

1. LOCATIONS OF ALL UTILITY LINES (DUCTS, PIPES, CONDUITS, AND OTHER OVERHEAD

OBSTRUCTIONS) SHOWN ARE APPROXIMATE. VERIFY IN FIELD EXACT LOCATIONS OF EXISTING

UTILITY LINES AND FIXTURES. COORDINATE ALL SUPPORT SYSTEMS SO AS NOT TO INTERFERE

WITH EACH OTHER. PROVIDE ADDITIONAL BRACING AS NECESSARY TO COMPLETE THE

INSTALLATION AT NO INCREASE TO THE CONTRACT SUM.

2. IN ALL CONSTRUCTION AREAS, SEAL ALL EXISTING AND NEW PENETRATIONS SUCH AS DUCTS, CONDUITS, PIPES, ETC. AT EXISTING AND NEW FIRE RESISTIVE RATED PARTITIONS AND

FLOOR/CEILING ASSEMBLIES, WHETHER SHOWN OR NOT AT NO CHANGE TO THE CONTRACT

SUM. USE SEALANT TYPE TO MAINTAIN PROPER FIRE RESISTIVE RATING OF THE PENETRATED

ASSEMBLIES. ALL PENETRATIONS AT FIRE RESISTIVE RATED PARTITIONS OR FLOOR/CEILING

ASSEMBLIES SHALL BE IN ACCORDANCE WITH THE APPROPRIATE U.L. LISTED APPROVED

SYSTEMS.

3. IF CONTRACTOR PROPOSED ALTERNATE CONSTRUCTION DETAILS AND ARE REVIEWED BY

THE CLIENT AND ARCHITECT, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS AND

TIME DELAYS RESULTING FROM CONTRACTOR'S PROPOSED ALTERNATE CONSTRUCTION

DETAILS WHICH AFFECT OTHER PARTS OF THE WORK OR THE WORK OF SEPARATE

CONTRACTORS.

4. FIRE PROTECTION AT FIRE RESISTIVE RATED WALLS AND PARTITIONS:

A. NO ELECTRICAL BOXES SHALL BE LOCATED BACK TO BACK WITHIN 2'-0" MEASURED

HORIZONTALLY, ON FIRE RESISTIVE RATED PARTITION. IF LOCATED WITHIN 2'-0" EACH

ELECTRICAL BOX SHALL BE SEPARATED WITH FIRE RESISTIVE RATED GYPSUM BOARD

AROUND FIVE SIDES RECESSED INTO PARTITION ASSEMBLY.

B. ANY ELECTRICAL BOX LARGER THAN 16 SQUARE INCHES SHALL BE PROTECTED WITH

FIRE RESISTIVE RATED GYPSUM BOARD AROUND FIVE SIDES.

C. FOR ANY 100 SQUARE FEET OF FIRE RESISTIVE RATED PARTITION AREA, THE

ALLOWABLE AGGREGATED AREA FOR UTILITY BOXES SHALL NOT EXCEED 100 SQUARE

INCHES.

5. CONTRACTOR STAGING AREA WILL BE DESIGNATED DURING THE CONSTRUCTION

SOLICITATION PHASE. COORDINATE WITH COR FOR EXACT LOCATION.

GENERAL NOTES PROJECT TEAM

ARCHITECT

MEI ARCHITECTS

239 9TH STREET

SAN FRANCISCO, CA 94103

TEL: (415) 703-0328

FAX: (415) 707-6328

MECHANICAL

CAPITAL ENGINEERING

11020 SUN CENTER DRIVE, SUITE 100

RANCHO CORDOVA, CA 95670

TEL: (916) 851-3500

ELECTRICAL

F.W. ASSOCIATES, INC.

520 3RD STREET, SUITE 206

OAKLAND, CA, 94607

TEL: (510) 763-7475

FAX: (510 763-7033

SIGNAGE

SMI SIGN SYSTEM, INC.

3903 CORNELL PLACE

FREDRICK, MD 21703

TEL: (301) 468-1132

PROJECT MANAGEMENT

CONCOURSE FEDERAL GROUP

1001 CONNECTICUT AVENUE, NW SUITE 704

WASHINGTON, DC 20036

TEL: (301) 802-6262

COST ESTIMATER

CONCOURSE FEDERAL GROUP

1001 CONNECTICUT AVENUE, NW SUITE 704

WASHINGTON, DC 20036

TEL: (301) 802-6262

PROJECT DATA

VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL

CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE

TECHNICAL INFORMATION LIBRARY (TIL).

2018 INTERNATIONAL BUILDING CODE (IBC)

2018 NFPA 101 LIFE SAFETY CODE

2018 NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 AND

NFPA 900

2017 OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA)

STANDARDS

2016 VA SEISMIC DESIGN REQUIREMENTS, H-18-8

2018 INTERNATIONAL MECHANICAL CODE (IMC)

2017 NATIONAL ELECTRICAL CODE (NEC)

2018 NATIONAL STANDARD PLUMBING CODE (NSPC)

2014 UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) INCLUDING VA

SUPPLEMENT, BARRIER FREE DESIGN GUIDE

VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE STANDARDS

62.1- 2016

SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE STANDARD 15 -

APPLICABLE BUILDING

CODES:

EXISTING BUILDING DATA

BUILDING 100

FIRST FLOOR: 7238 SF

SECOND FLOOR: 5,002 SF

THIRD FLOOR: 4,942 SF

FOURTH FLOOR: 5,041 SF

FULLY AUTOMATIC SPRINKLERED

PROJECT GROSS AREA:

FIRE PROTECTION:

BUILDING 101

FIRST FLOOR: 6658 SF

SECOND FLOOR: 434 SF

THIRD FLOOR: 492 SF

FOURTH FLOOR: 641 SF

FULLY AUTOMATIC SPRINKLERED

OCCUPANCY

CLASSIFICATION:

CONSTRUCTION TYPE:

FIRE PROTECTION:

NO. OF STORIES:

EXISTING BUILDING AREA:

BUILDING 100

GROUP I & B [IBC]

HEALTHCARE & BUSINESS [NFPA]

TYPE I-B [IBC]

TYPE II (222) [NFPA]

FULLY AUTOMATIC SPRINKLERED

FOUR STORIES AND ONE BASEMENT

108,200 SF

BUILDING 101

GROUP B [IBC]

BUSINESS [NFPA]

TYPE I-A [IBC]

TYPE II (111) [NFPA]

FULLY AUTOMATIC SPRINKLERED

FOUR STORIES

41,000 SF

PROJECT DESCRIPTION

THE SCOPE OF WORK FOR THIS PROJECT CONSISTS OF THE FOLLOWING:

B100 FIRST, SECOND, THIRD, AND FOURTH FLOOR PUBLIC CORRIDORS / ELEVATOR LOBBIES

REPLACE EXISTING CERAMIC FLOOR TILE WITH RESINOUS TERRAZZO FLOORING

REPLACE EXISTING CERAMIC WALL TILE WITH PHENOLIC WALL PANELING

B100 FIRST, SECOND, THIRD, AND FOURTH FLOOR TOILET ROOMS

REPLACE EXISTING WALL TILE, FLOOR TILE, TOILET PARTITION, TOILET ACCESSORIES, PLUMBING

FIXTURES, LIGHTING FIXTURES, AND FINISH CEILING IN ITS ENTIRETY

B101 FIRST FLOOR PUBLIC CORRIDORS / ELEVATOR LOBBIES

REPLACE EXISTING CERAMIC FLOOR TILE WITH RESINOUS TERRAZZO FLOORING

REPLACE EXISTING CERAMIC WALL TILE WITH PHENOLIC WALL PANELING

B100 AND B101

REPLACE EXISTING SIGNAGE WITH NEW SIGNAGE AS SHOWN ON DRAWINGS.

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

PROJECT TEAM, PROJECT DATA,

ABBREVIATIONS, SYMBOLS,

MATERIALS, AND DRAWING INDEX

G0-2

100 / 101

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMMMC

100% SUBMITTAL

VICINITY MAP LOCATION MAPPROJECT SITE

BUILDING 100 & 101

PROJECT SITE,

BUILDING 100 & 101

GENERAL

G0-1 COVER SHEET

G0-2 PROJECT TEAM, PROJECT DATA, ABBREVIATIONS, SYMBOLS, MATERIALS, AND DRAWING INDEX

G0-3.1 FIRST FLOOR AREA OF WORK AND CONSTRUCTION PHASING PLAN

G0-3.2 SECOND FLOOR AREA OF WORK AND CONSTRUCTION PHASING PLAN

G0-3.3 THIRD FLOOR AREA OF WORK AND CONSTRUCTION PHASING PLAN

G0-3.4 FOURTH FLOOR AREA OF WORK AND CONSTRUCTION PHASING PLAN

DRAWING LIST

MECHANICAL & PLUMBING

M1-1A PLUMBING & MECHANICAL PLUMBING FIXTURE SCHEDULE

M2-1A BUILDING 100 PLUMBING & MECHANICAL FIRST FLOOR OVERALL PLAN

M2-2A BUILDING 100 PLUMBING & MECHANICAL SECOND FLOOR OVERALL PLAN

M2-3A BUILDING 100 PLUMBING & MECHANICAL THIRD FLOOR OVERALL PLAN

M2-4A BUILDING 100 PLUMBING & MECHANICAL FOURTH FLOOR OVERALL PLAN

M4-1A BUILDING 100 PLUMBING & MECHANICAL FIRST FLOOR ENLARGED PLANS

M4-2A BUILDING 100 PLUMBING & MECHANICAL SECOND FLOOR ENLARGED PLANS

M4-3A BUILDING 100 PLUMBING & MECHANICAL THIRD FLOOR ENLARGED PLANS

M4-4A BUILDING 100 PLUMBING & MECHANICAL FOURTH FLOOR ENLARGED PLANS

ELECTRICAL

ES0-1 SYMBOL LEGEND, ABBREVIATIONS, GENERAL NOTES & FIXTURE SCHEDULE

ES1-1 FIRST FLOOR AREA OF WORK OVERALL PLAN

ES1-2 SECOND FLOOR AREA OF WORK OVERALL PLAN

ES1-3 THIRD FLOOR AREA OF WORK OVERALL PLAN

ES1-4 FOURTH FLOOR AREA OF WORK OVERALL PLAN

ES2-2 BUILDING 100 SECOND FLOOR

ES2-3 BUILDING 100 THIRD FLOOR

ES2-4 BUILDING 100 FOURTH FLOOR

ES4-1A BUILDING 100 FIRST FLOOR ENLARGED FLOOR PLAN - DEMO, POWER, & LIGHTING

ES4-2A BUILDING 100 SECOND FLOOR ENLARGED FLOOR - DEMO, POWER, & LIGHTING

ES4-3A BUILDING 100 THIRD FLOOR ENLARGED FLOOR PLAN - DEMO, POWER, & LIGHTING

ES4-4A BUILDING 100 FOURTH FLOOR ENLARGED FLOOR PLAN - DEMO, POWER, & LIGHTING

ES6-1 DETAILS AND DIAGRAMS

ARCHITECTURE

AS1-1A BUILDING 100 FIRST FLOOR PLAN - DEMOLITION

AS1-1B BUILDING 101 FIRST FLOOR PLAN - DEMOLITION

AS1-2A BUILDING 100 SECOND FLOOR PLAN - DEMOLITION

AS1-3A BUILDING 100 THIRD FLOOR PLAN - DEMOLITION

AS1-4A BUILDING 100 FOURTH FLOOR PLAN - DEMOLITION

AS2-1A BUILDING 100 FIRST FLOOR PLAN

AS2-1B BUILDING 101 FIRST FLOOR PLAN

AS2-2A BUILDING 100 & 101 SECOND FLOOR PLAN

AS2-3A BUILDING 100 & 101 THIRD FLOOR PLAN

AS2-4A BUILDING 100 & 101 FOURTH FLOOR PLAN

AS4-1A BUILDING 100 FIRST FLOOR - ENLARGED DEMOLITION, FLOOR, AND REFLECTED CEILING PLANS AS4-2A BUILDING 100 SECOND FLOOR ENLARGED DEMOLITION, FLOOR, AND REFLECTED CEILING PLANS AS4-3A BUILDING 100 THIRD FLOOR ENLARGED DEMOLITION, FLOOR, AND REFLECTED CEILING PLANS AS4-4A BUILDING 100 FOURTH FLOOR ENLARGED DEMOLITION, FLOOR, AND REFLECTED CEILING PLANS AS5-1A BUILDING 100 & 101 FIRST FLOOR INTERIOR ELEVATIONS, AND TYPICAL MOUNTING HEIGHTS

AS5-1B BUILDING 100 FIRST FLOOR INTERIOR ELEVATIONS

AS5-1C BUILDING 100 FIRST FLOOR INTERIOR ELEVATIONS

AS5-2A BUILDING 100 & 101 SECOND FLOOR INTERIOR ELEVATIONS

AS5-3A BUILDING 100 & 101 THIRD FLOOR INTERIOR ELEVATIONS

AS5-4A BUILDING 100 & 101 FOURTH FLOOR INTERIOR ELEVATIONS

AS9-1 PARTITION AND INTERIOR DETAILS

AS9-1A INTERIOR DETAILS

AS9-3 CEILING DETAILS

SIGNAGE

AG-1 SIGNAGE LOCATION PLANS

AG-2 SIGNAGE SCHEDULE

AG-3 SIGNAGE DETAILS

AG-4 SIGNAGE DETAILS

UPDN

UP

DN

UP

DN

DN

DN

DN

1238910111213141516

B

D

E

F

G

H

I

J

47 6 5

L

A

M

N

O

Q

P

J.2

C

7.8

K

I.3

I.5

8.58.7

M.3

9.9

1.2.3.4.5.6.7.8.9.10.

0.30.7

J.1

B.

C.

C.5

K.

L.

M.

N.

O.

P.

AS2-4A

AS2-4A

(E) CORRIDOR

B1-C01

(E) MALE

TOILET

B1-120

(E) FEMALE

TOILET

B1-122

(E) VESTIBULE

B1-C11

(E) CORRIDOR

F1-C05

(E) CORRIDOR

B1-C22

(E)

COURTYARD

(E) CORRIDOR

B1-C24

(E) CORRIDOR

B1-C21

(E) CORRIDOR

B1-C23

(E) CORRIDOR

F1-C03

(E) CORRIDOR

F1-C02

(E) CORRIDOR

F1-C06

(E) CORRIDOR

A1-C14

(E) ELEVATOR

LOBBY

A1-C15

(E) CORRIDOR

C1-016

(E) ELEVATOR

LOBBY

C1-C17

(E) CORRIDOR

D1-C04

(E) CORRIDOR

D1-C03

(E) CORRIDOR

D1-C14

(E)

INFOMATION

B1-100

(E)

LOBBY/WAIT

B1-C10

(E) FEMALE

TOILET

C1-373

(E) MALE

TOILET

F1-123

(E) FEMALE

TOILET

F1-121

ALL GENDER

TOILET

F1-236

ALL GENDER

TOILET

F1-238

(E) MALE

TOILET

C1-371

(E) ELEVATOR

LOBBY

B1-C20

(E) ELEVATOR

LOBBY

B1-C02

(E) CORRIDOR

B1-C03

(E) CORRIDOR

A1-C01

(E) CORRIDOR

A1-C30

(E) BRIDGE

A1-C10

(E) FOOD

SERVICE

C1-204

(E) VESTIBULE

C1-202

(E) ENTRY

C1-200

(E) CORRIDOR

B1-C10

ALL GENDER

TOILET

F1-122

(E) STORAGE

A1-452

(E) AE

DECENDENT

AFFAIRS

A1-106

(E) CORRIDOR

A1-C13

(E) ER SDC

A1-130

(E) RELEASE

OF INFO

F1- 115

(E) BLOOD

DRAW ROOM

F1-120

(E) VOL

SERVICE

F1-110

(E) OFFICE 02

F1-110A

(E) OFFICE 01

F1-110B

(E) PATIENT

COFFEE ROOM

F1-100

(E) CORRIDOR

F1-C01

(E) BIOMED SAT

E1-280

(E) EDUC

OFFICE

E1-200

(E)

OUTPATIENT

PHARMACY

SERVICE

ADMIN OFFICE

E1-210

(E) CONS

E1-110

(E)

OUTPATIENT

PHARMACY

E1-100

(E) DP

E1-101

(E) IV WKRM

E1-103

(E) HAC

A1-150

(E) CORRIDOR

F1-C07

(E) CORRIDOR

E1-C21

(E) CORRIDOR

E1-C01(E) INVEST

DRUGS

E1-105

(E) VAULT / SEC

/ DISP / FLAM

E1-140(E) TEL / DATA

E1-TC4

(E) ELEC

E1-EC4

(E) OPEN IP &

OP PHARMACY

E1-120

(E) IV PREP

E1-???

(E) CH RES

D1-231

(E) CORRIDOR

D1-C12

(E) PROC 01

D1-238

(E) LAB

D1-236

(E) NS

D1-200

(E) CORRIDOR

D1-C10

(E) PATIENT

LOCKER

D1-201

(E) CORRIDOR

D1-C02

(E) TRAVEL

D1-100

(E) BMS

STORAGE

C1-363

(E) CORRIDOR

C1-C14

(E) CONSULT

ROOM

C1-115

(E) CONSULT

ROOM

C1-11

(E) PROCESS 1

C1-109

(E) MED/TMT

C1-105

(E) FEMALE

TOILET

C1-103

(E) RECEPTION

C1-100A

(E) WAIT

C1-100

(E) HAC

E1-144

(E) POISON

E1-146

(E) RETAIL

STORE

A1-110

(E) STORAGE

A1-100

(E) EUCH

A1-121

(E) CHAPL 7

A1-122

(E) CHAPLAIN

SERVICE

A1-120

(E) SACRISTY

A1-130

CHAPEL

A1-132

(E) ELEC

A1-EC1

(E) TEL / DATA

A1-TC1

(E) BMS

STORAGE

A1-229

(E) STAFF

TOILET

A1-230

(E) STORAGE

A1-231

(E) CREDIT

UNION

A1-210

(E) FOOD PREP

C1-220

(E) FOOD

SERVICE

C1-206

(E)

AUDITORIUM

B1-100

(E) KITCHEN

C1-234

(E) VESTIBULE

C1-201

(E) CORRIDOR

C1-C01

(E) COFFEE

SHOP

C1-203

(E) ADMITTING

& ELIGIBILITY

A1-100

(E) TELE / DATA

A1-TC2

(E) ELEC

A1-EC2

(E) CO-PAY

D1-110

(E) AGENT

CASHIER

D1-120

AS4-1A

CONSTRUCTION PHASING NOTES1

1. CONTRACTOR SHALL SUBMIT CONSTRUCTION PHASING SCHEDULE FOR GOVERNMENT REVIEW AND

APPROVAL. CONSTRUCTION PHASING SCHEDULE SHALL INCLUDE TOTAL NUMBERS OF PROPOSED

PHASES AND APPROXIMATE DATES FOR EACH PHASE.

2. CONTRACTOR SHALL SUBMIT CONSTRUCTION PHASING PLANS FOR GOVERNMENT REVIEW AND

APPROVAL. CONTRUCTION PHASING PLAN SHALL INDICATE BOUNDARIES OF EACH CONSTRUCTION

PHASE, PROPOSED CONSTRUCTION BARRIER LOCATIONS, AND ALTERNATE EGRESS ROUTE FOR

CONSTRUCTION AREAS AND EXISTING ADJACENT AREAS AFFECTED BY THE CONSTRUCTION AT EACH

CONSTRUCTION PHASE.

3. WORK IN EXISTING CORRIDORS / LOBBIES:

A. ALL WORK IN EXISITNG CORRIDORS AND LOBBIES SHALL BE EXECUTED IN A MINIMUM TOTAL OF

TWENTY-FIVE (25) CONSTRUCTION PHASES. CONSTRUCTION PHASES AREAS ARE NOT SHOWN

ON DRAWINGS, CONTRACTOR SHALL COORDINATE EXACT NUMBER OF PHASES, AREAS AND

BOUNDARIES FOR EACH PHASE, AND SEQUENCES OF PHASES IN FIELD WITH CONTRACTING

OFFICER'S REPRESENTATIVE (COR). ADDITIONAL CONSTRUCTION PHASES AS REQUIRED BY COR

OR AS RESULT OF FIELD CONDITION SHALL NOT INCREASE CONTRACT COST.

B. ALL WORK IN EXISITNG CORRIDORS AND LOBBIES SHALL BE PERFORMED DURING BUSINESS

OFF-HOURS. COORDINATE AND VERIFY EXACT TIMING OF WORK WITH COR. CLOSE DOWN OF

THESE AREAS DURING BUSINESS HOURS WILL NOT BE PERMITTED UNLESS WRITTEN

PERMISSION IS OBTAINED FROM THE COR. ALL WORK IN THESE AREAS SHALL BE SCHEDULED

AND ARRANGED SO THAT THESE AREAS CAN BE OPEN DURING BUSINESS HOURS TO MAINTAIN

HOSPTIAL OPERATIONS AND TO ALLOW PUBLIC TRAFFIC. AT THE END OF EACH WORK SHIFT,

CONTRACTOR SHALL THOROUGHLY CLEAN WORK AREAS, PROTECT WORK, AND PROVIDE

COVER BOARD OR OTHER APPROPRIATE PROTECTION AS REQUIRED AND AS REQUESTED BY

COR PRIOR TO RE-OPENING OF THESE AREAS FOR PUBLIC ACCESS.

C. COMPLETE DEMOLITION AND CONSTRUCTION FOR EACH PHASE. CONTRACTOR SHALL OBTAIN

ACCEPTANCE FROM GOVERNMENT PRIOR TO BEGINNING WORK IN THE NEXT CONSTRUCTION

PHASE.

4. WORK IN EXISTING TOILET ROOMS

A. ALL WORK IN EXISTING TOILET ROOMS SHALL BE EXECUTED IN A MINIMUM TOTAL OF SIXTEEN

(16) CONSTRUCTION PHASES. CONSTRUCTION PHASES AREAS ARE NOT SHOWN ON DRAWINGS,

CONTRACTOR SHALL COORDINATE EXACT NUMBER OF PHASES, AREAS AND BOUNDARIES FOR

EACH PHASE, AND SEQUENCES OF PHASES IN FIELD WITH CONTRACTING OFFICER'S

REPRESENTATIVE (COR). ADDITIONAL CONSTRUCTION PHASES AS REQUIRED BY COR OR AS

RESULT OF FIELD CONDITION SHALL NOT INCREASE CONTRACT COST. AT EACH CONSTRUCTION

PHASE, NO MORE THAN TWO TOILET ROOMS SHALL BE SHUT DOWN.

B. TOILET ROOMS CONSTRUCTION PHASES ARE INDEPENDENT OF CORRIDORS / LOBBIES WORK

CONSTRUCTION PHASES, TOILET ROOMS CONSTRUCTION PHASE CAN EXECUTE

CONCURRENTLY WITH CORRIDORS / LOBBIES CONSTRUCTION PHASES.

C. ALL WORK IN EXISTING TOILET ROOMS SHALL BE PERFORMED DURING BUSINESS HOURS.

D. COMPLETE DEMOLITION AND CONSTRUCTION FOR EACH PHASE, CONTRACTOR SHALL OBTAIN

CERTIFICATE FOR GOVERNMENT MOVE-IN PRIOR TO BEGINNING WORK IN THE NEXT

CONSTRUCTION PHASE.

B100

B101

N

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

FIRST FLOOR AREA OF WORK AND

CONSTRUCTION PHASING PLAN

G0-3.1

100 / 101

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMChecker

100% SUBMITTAL

1" = 20'-0"

4 FIRST FLOOR AREA OF WORK AND CONSTRUCTION PHASING PLAN

1238910111213141516

B

D

E

F

G

H

I

J

7 6 5

L

A

M

N

O

Q

P

J.2

C

K

I.3

I.5

8.58.7

M.3

9.9

1.2.3.4.5.6.7.8.9.10.

0.30.7

J.1

B.

C.

C.5

K.

L.

M.

N.

O.

P.

AS2-2A

AS4-2A

AS2-2A

(E) CORRIDOR

B2-C24

(E) ELEVATOR

LOBBY

B2-C20

(E) CORRIDOR

B2-C21

(E) CORRIDOR

B2-C22

(E) CORRIDOR

B2-C23

ALL GENDER

TOILET

C2-104

ALL GENDER

TOILET

C2-106

ALL GENDER

TOILET

F2-203

ALL GENDER

TOILET

F2-201

(E) PUBLIC

TOILET

F2-360

(E) CORRIDOR

F2-C01

(E) CORRIDOR

C2-C01

(E) CORRIDOR

E2-C30

(E) CORRIDOR

B2-C04

(E) MALE

TOILET

B2-280

(E) FEMALE

TOILET

B2-290

(E) ELEVATOR

LOBBY

B2-C01

(E) FAMILY

WAIT

A1-178

(E) SOCIAL WK

A2-100

(E) CORRIDOR

A2-C01

(E) CORRIDOR

A2-C09

(E) ELEVATOR

LOBBY

A2-C10

(E) HS

F2-202

(E) VEST

F2-204

(E) CHIEF

F2-136

(E) STF PHYS

F2-134

(E) STF PHYS

F2-132

(E) STF PHYS

F2-130

(E)

PULMONARY

F2-100

(E) CORRIDOR

E2-C30(E) HYG 1

E2-302

(E) HYG 2

E2-301

(E) CORRIDOR

E2-C20

(E) PORCELAIN

E2-360A

(E) WAIT

E2-200

(E) CHIEF

E2-100C

(E)

NEPHROLOGY

E2-100

(E) OFFICE

E2-110

(E) CORRIDOR

D2-C01

(E) AUD

STORAGE 1

D2-100

(E) PHYS /

CONS

C2-174

(E) HS

C2-170

(E) N SUPV

C2-176

(E) VIS LOUNGE

C2-100

(E) CORRIDOR

C2-C09

(E) ELEVATOR

LOBBY

C2-C10

(E) CORRIDOR

C2-C08

(E) PHYS ASST

C2-171

(E) HAC

C2-173

(E) BIOCHEM

LAB

B2-150

(E) CHEM

B2-136

(E) CORRIDOR

B2-C05

(E) CORRIDOR

B2-C01

(E) TEL / DATA

B2-TC2

(E) ELEC

B2-EC2

CONSTRUCTION PHASING NOTES1

1. CONTRACTOR SHALL SUBMIT CONSTRUCTION PHASING SCHEDULE FOR GOVERNMENT REVIEW AND

APPROVAL. CONSTRUCTION PHASING SCHEDULE SHALL INCLUDE TOTAL NUMBERS OF PROPOSED

PHASES AND APPROXIMATE DATES FOR EACH PHASE.

2. CONTRACTOR SHALL SUBMIT CONSTRUCTION PHASING PLANS FOR GOVERNMENT REVIEW AND

APPROVAL. CONTRUCTION PHASING PLAN SHALL INDICATE BOUNDARIES OF EACH CONSTRUCTION

PHASE, PROPOSED CONSTRUCTION BARRIER LOCATIONS, AND ALTERNATE EGRESS ROUTE FOR

CONSTRUCTION AREAS AND EXISTING ADJACENT AREAS AFFECTED BY THE CONSTRUCTION AT EACH

CONSTRUCTION PHASE.

3. WORK IN EXISTING CORRIDORS / LOBBIES:

A. ALL WORK IN EXISITNG CORRIDORS AND LOBBIES SHALL BE EXECUTED IN A MINIMUM TOTAL OF

TWENTY-FIVE (25) CONSTRUCTION PHASES. CONSTRUCTION PHASES AREAS ARE NOT SHOWN

ON DRAWINGS, CONTRACTOR SHALL COORDINATE EXACT NUMBER OF PHASES, AREAS AND

BOUNDARIES FOR EACH PHASE, AND SEQUENCES OF PHASES IN FIELD WITH CONTRACTING

OFFICER'S REPRESENTATIVE (COR). ADDITIONAL CONSTRUCTION PHASES AS REQUIRED BY COR

OR AS RESULT OF FIELD CONDITION SHALL NOT INCREASE CONTRACT COST.

B. ALL WORK IN EXISITNG CORRIDORS AND LOBBIES SHALL BE PERFORMED DURING BUSINESS

OFF-HOURS. COORDINATE AND VERIFY EXACT TIMING OF WORK WITH COR. CLOSE DOWN OF

THESE AREAS DURING BUSINESS HOURS WILL NOT BE PERMITTED UNLESS WRITTEN

PERMISSION IS OBTAINED FROM THE COR. ALL WORK IN THESE AREAS SHALL BE SCHEDULED

AND ARRANGED SO THAT THESE AREAS CAN BE OPEN DURING BUSINESS HOURS TO MAINTAIN

HOSPTIAL OPERATIONS AND TO ALLOW PUBLIC TRAFFIC. AT THE END OF EACH WORK SHIFT,

CONTRACTOR SHALL THOROUGHLY CLEAN WORK AREAS, PROTECT WORK, AND PROVIDE

COVER BOARD OR OTHER APPROPRIATE PROTECTION AS REQUIRED AND AS REQUESTED BY

COR PRIOR TO RE-OPENING OF THESE AREAS FOR PUBLIC ACCESS.

C. COMPLETE DEMOLITION AND CONSTRUCTION FOR EACH PHASE. CONTRACTOR SHALL OBTAIN

ACCEPTANCE FROM GOVERNMENT PRIOR TO BEGINNING WORK IN THE NEXT CONSTRUCTION

PHASE.

4. WORK IN EXISTING TOILET ROOMS

A. ALL WORK IN EXISTING TOILET ROOMS SHALL BE EXECUTED IN A MINIMUM TOTAL OF SIXTEEN

(16) CONSTRUCTION PHASES. CONSTRUCTION PHASES AREAS ARE NOT SHOWN ON DRAWINGS,

CONTRACTOR SHALL COORDINATE EXACT NUMBER OF PHASES, AREAS AND BOUNDARIES FOR

EACH PHASE, AND SEQUENCES OF PHASES IN FIELD WITH CONTRACTING OFFICER'S

REPRESENTATIVE (COR). ADDITIONAL CONSTRUCTION PHASES AS REQUIRED BY COR OR AS

RESULT OF FIELD CONDITION SHALL NOT INCREASE CONTRACT COST. AT EACH CONSTRUCTION

PHASE, NO MORE THAN TWO TOILET ROOMS SHALL BE SHUT DOWN.

B. TOILET ROOMS CONSTRUCTION PHASES ARE INDEPENDENT OF CORRIDORS / LOBBIES WORK

CONSTRUCTION PHASES, TOILET ROOMS CONSTRUCTION PHASE CAN EXECUTE

CONCURRENTLY WITH CORRIDORS / LOBBIES CONSTRUCTION PHASES.

C. ALL WORK IN EXISTING TOILET ROOMS SHALL BE PERFORMED DURING BUSINESS HOURS.

D. COMPLETE DEMOLITION AND CONSTRUCTION FOR EACH PHASE, CONTRACTOR SHALL OBTAIN

CERTIFICATE FOR GOVERNMENT MOVE-IN PRIOR TO BEGINNING WORK IN THE NEXT

CONSTRUCTION PHASE.

B100

B101

N

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

SECOND FLOOR AREA OF WORK AND

CONSTRUCTION PHASING PLAN

G0-3.2

100 / 101

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMChecker

100% SUBMITTAL 1" = 20'-0"

4 SECOND FLOOR AREA OF WORK AND CONSTRUCTION PHASING PLAN

DN

UPDN

UP

DN

UPDN

1238910111213141516

B

D

E

F

G

H

I

J

47 6 5

L

A

M

N

O

Q

P

J.2

C

7.8

K

I.3

I.5

8.58.7

M.3

9.9

1.2.3.4.5.6.7.8.9.10.

0.30.7

J.1

B.

C.

C.5

K.

L.

M.

N.

O.

P.

AS2-3A

AS2-3A

ALL GENDER

TOILET

F3-243

ALL GENDER

TOILET

F3-241

(E) CORRIDOR

B3-C21

(E) ELEVATOR

LOBBY

B3-C20

(E) CORRIDOR

B3-C24

(E) CORRIDOR

B3-C23

(E) CORRIDOR

B3-C22

ALL GENDER

TOILET

C3-104

ALL GENDER

TOILET

C3-106

(E) CORRIDOR

C3-C01

(E) CORRIDOR

F3-C01

(E) ELEVATOR

LOBBY

B3-C01

(E) CORRIDOR

B3-C07

(E) MALE

TOILET

B3-280

(E) FEMALE

TOILET

B3-290

(E) ELEVATOR

LOBBY

A3-C10

(E) HS

F3-242

(E) CONS /

MEDIT

F3-240

(E) CORRIDOR

A3-C09

(E) CHIEF

F3-235

(E) THER

F3-236

(E) CORRIDOR

F3-C20

(E) CORRIDOR

F3-C21

(E) CORRIDOR

B3-C30

(E) CORRIDOR

C3-C09

(E) ELEVATOR

LOBBY

C3-C10

(E) SOCIAL WK

C3-177

(E) PHYS ASST

C3-174

(E) SUPV MAS

C3-176

(E) VIS LNG

C3-100

(E) N SUPV

C3-172

(E) STR W/C

C3-170

(E) CORRIDOR

C3-C08

(E) HEAD

NURSE

C3-108

(E) CONF

B3-136

(E) CORRIDOR

B3-C05

(E) HAC

C3-173

(E) DIET

C3-171

(E) CORRIDOR

B3-C01

(E)

ELECTRICAL

B3-EC2

(E) TEL / DATA

B3-TC2

(E) CORRIDOR

A3-C01

(E) SOCIAL WK

A3-100

(E) FAM WAIT

A3-176

(E) OPERATION

RECOVERY

ROOM RECP

F3-100

E3-105

(E) BIO ENG

E3-110

F3-104

(E) SURGERY

WAITING ROOM

F3-108

F3-102

CONSTRUCTION PHASING NOTES1

1. CONTRACTOR SHALL SUBMIT CONSTRUCTION PHASING SCHEDULE FOR GOVERNMENT REVIEW AND

APPROVAL. CONSTRUCTION PHASING SCHEDULE SHALL INCLUDE TOTAL NUMBERS OF PROPOSED

PHASES AND APPROXIMATE DATES FOR EACH PHASE.

2. CONTRACTOR SHALL SUBMIT CONSTRUCTION PHASING PLANS FOR GOVERNMENT REVIEW AND

APPROVAL. CONTRUCTION PHASING PLAN SHALL INDICATE BOUNDARIES OF EACH CONSTRUCTION

PHASE, PROPOSED CONSTRUCTION BARRIER LOCATIONS, AND ALTERNATE EGRESS ROUTE FOR

CONSTRUCTION AREAS AND EXISTING ADJACENT AREAS AFFECTED BY THE CONSTRUCTION AT EACH

CONSTRUCTION PHASE.

3. WORK IN EXISTING CORRIDORS / LOBBIES:

A. ALL WORK IN EXISITNG CORRIDORS AND LOBBIES SHALL BE EXECUTED IN A MINIMUM TOTAL OF

TWENTY-FIVE (25) CONSTRUCTION PHASES. CONSTRUCTION PHASES AREAS ARE NOT SHOWN

ON DRAWINGS, CONTRACTOR SHALL COORDINATE EXACT NUMBER OF PHASES, AREAS AND

BOUNDARIES FOR EACH PHASE, AND SEQUENCES OF PHASES IN FIELD WITH CONTRACTING

OFFICER'S REPRESENTATIVE (COR). ADDITIONAL CONSTRUCTION PHASES AS REQUIRED BY COR

OR AS RESULT OF FIELD CONDITION SHALL NOT INCREASE CONTRACT COST.

B. ALL WORK IN EXISITNG CORRIDORS AND LOBBIES SHALL BE PERFORMED DURING BUSINESS

OFF-HOURS. COORDINATE AND VERIFY EXACT TIMING OF WORK WITH COR. CLOSE DOWN OF

THESE AREAS DURING BUSINESS HOURS WILL NOT BE PERMITTED UNLESS WRITTEN

PERMISSION IS OBTAINED FROM THE COR. ALL WORK IN THESE AREAS SHALL BE SCHEDULED

AND ARRANGED SO THAT THESE AREAS CAN BE OPEN DURING BUSINESS HOURS TO MAINTAIN

HOSPTIAL OPERATIONS AND TO ALLOW PUBLIC TRAFFIC. AT THE END OF EACH WORK SHIFT,

CONTRACTOR SHALL THOROUGHLY CLEAN WORK AREAS, PROTECT WORK, AND PROVIDE

COVER BOARD OR OTHER APPROPRIATE PROTECTION AS REQUIRED AND AS REQUESTED BY

COR PRIOR TO RE-OPENING OF THESE AREAS FOR PUBLIC ACCESS.

C. COMPLETE DEMOLITION AND CONSTRUCTION FOR EACH PHASE. CONTRACTOR SHALL OBTAIN

ACCEPTANCE FROM GOVERNMENT PRIOR TO BEGINNING WORK IN THE NEXT CONSTRUCTION

PHASE.

4. WORK IN EXISTING TOILET ROOMS

A. ALL WORK IN EXISTING TOILET ROOMS SHALL BE EXECUTED IN A MINIMUM TOTAL OF SIXTEEN

(16) CONSTRUCTION PHASES. CONSTRUCTION PHASES AREAS ARE NOT SHOWN ON DRAWINGS,

CONTRACTOR SHALL COORDINATE EXACT NUMBER OF PHASES, AREAS AND BOUNDARIES FOR

EACH PHASE, AND SEQUENCES OF PHASES IN FIELD WITH CONTRACTING OFFICER'S

REPRESENTATIVE (COR). ADDITIONAL CONSTRUCTION PHASES AS REQUIRED BY COR OR AS

RESULT OF FIELD CONDITION SHALL NOT INCREASE CONTRACT COST. AT EACH CONSTRUCTION

PHASE, NO MORE THAN TWO TOILET ROOMS SHALL BE SHUT DOWN.

B. TOILET ROOMS CONSTRUCTION PHASES ARE INDEPENDENT OF CORRIDORS / LOBBIES WORK

CONSTRUCTION PHASES, TOILET ROOMS CONSTRUCTION PHASE CAN EXECUTE

CONCURRENTLY WITH CORRIDORS / LOBBIES CONSTRUCTION PHASES.

C. ALL WORK IN EXISTING TOILET ROOMS SHALL BE PERFORMED DURING BUSINESS HOURS.

D. COMPLETE DEMOLITION AND CONSTRUCTION FOR EACH PHASE, CONTRACTOR SHALL OBTAIN

CERTIFICATE FOR GOVERNMENT MOVE-IN PRIOR TO BEGINNING WORK IN THE NEXT

CONSTRUCTION PHASE.

B100

B101

N

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

THIRD FLOOR AREA OF WORK AND

CONSTRUCTION PHASING PLAN

G0-3.3

100 / 101

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMChecker

4 THIRD FLOOR AREA OF WORK AND CONSTRUCTION PHASING PLAN

DN

DN

DN

DN

UP

DN

DN

DN

DN

DN

DNDN

1238910111213141516

B

D

E

F

G

H

I

J

47 6 5

L

A

M

N

O

Q

P

J.2

C

7.8

K

I.3

I.5

8.58.7

M.3

9.9

1.2.3.4.5.6.7.8.9.10.

0.30.7

J.1

B.

C.

C.5

K.

L.

M.

N.

O.

P.

AS2-4A

AS2-4A

AS4-4A

(E) CORRIDOR

B4-C24

(E) ELEVATOR

LOBBY

B4-C20

(E) CORRIDOR

B4-C21

(E) CORRIDOR

B4-C23

(E) CORRIDOR

B4-C22

ALL GENDER

TOILET

F4-133

ALL GENDER

TOILET

F4-131

ALL GENDER

TOILET

C4-104

ALL GENDER

TOILET

C4-106

(E) STAFF

TOILET

F4-101

(E) STAFF

TOILET

F4-102

(E) CORRIDOR

F4-C01

(E) CORRIDOR

C4-C01

(E) CORRIDOR

C4-C17

(E) MALE

TOILET

B4-280

(E) FEMALE

TOILET

B4-290

(E) CORRIDOR

B4-C07

(E) ELEVATOR

LOBBY

B4-C01

(E) CORRIDOR

A4-C09

(E) ELEVATOR

LOBBY

A4-C10

(E) SOCIAL WK

A4-176

(E) HEAD

NURSE

A4-174

(E) HS

A4-100

(E) CORRIDOR

A4-C01

(E) TEL / DATA

B4-TC2

(E) ELEC

B4-EC2

(E) CORRIDOR

A4-C02

(E) CONF

B4-100

(E) CORRIDOR

C4-C09

(E) SPD

C4-175

(E) ELEVATOR

LOBBY

C4-C10

(E) HAC

C4-173

(E) BMS

STORAGE

C4-171

(E) CORRIDOR

D4-C01

(E) LAB

E4-216

(E) LAB

E4-218

(E) LAB

E4-220

(E) LAB

E4-222

(E) HAC

E4-300

(E) HEMA

F4-110

(E) MADP

CONTROL

F4-130A

(E) ACCS PROC

& DIST

F4-130

(E) BB TRANS

SERV

F4-140

(E) VEST

F4-200

(E) CORRIDOR

F4-C20

(E) REFR

F4-120A

(E) BULK

STORAGE

F4-120

(E) ADP CRTS

F4-122

(E) URIN

F4-168

(E) CLIN CHEM

F4-164

(E) DAYROOM

C4-170

(E) KITCHEN

C4-100

(E) PT/OT

OFFICE

B4-170

(E) EXTENDED

CARE ADMIN

B4-C03

CONSTRUCTION PHASING NOTES1

1. CONTRACTOR SHALL SUBMIT CONSTRUCTION PHASING SCHEDULE FOR GOVERNMENT REVIEW AND

APPROVAL. CONSTRUCTION PHASING SCHEDULE SHALL INCLUDE TOTAL NUMBERS OF PROPOSED

PHASES AND APPROXIMATE DATES FOR EACH PHASE.

2. CONTRACTOR SHALL SUBMIT CONSTRUCTION PHASING PLANS FOR GOVERNMENT REVIEW AND

APPROVAL. CONTRUCTION PHASING PLAN SHALL INDICATE BOUNDARIES OF EACH CONSTRUCTION

PHASE, PROPOSED CONSTRUCTION BARRIER LOCATIONS, AND ALTERNATE EGRESS ROUTE FOR

CONSTRUCTION AREAS AND EXISTING ADJACENT AREAS AFFECTED BY THE CONSTRUCTION AT EACH

CONSTRUCTION PHASE.

3. WORK IN EXISTING CORRIDORS / LOBBIES:

A. ALL WORK IN EXISITNG CORRIDORS AND LOBBIES SHALL BE EXECUTED IN A MINIMUM TOTAL OF

TWENTY-FIVE (25) CONSTRUCTION PHASES. CONSTRUCTION PHASES AREAS ARE NOT SHOWN

ON DRAWINGS, CONTRACTOR SHALL COORDINATE EXACT NUMBER OF PHASES, AREAS AND

BOUNDARIES FOR EACH PHASE, AND SEQUENCES OF PHASES IN FIELD WITH CONTRACTING

OFFICER'S REPRESENTATIVE (COR). ADDITIONAL CONSTRUCTION PHASES AS REQUIRED BY COR

OR AS RESULT OF FIELD CONDITION SHALL NOT INCREASE CONTRACT COST.

B. ALL WORK IN EXISITNG CORRIDORS AND LOBBIES SHALL BE PERFORMED DURING BUSINESS

OFF-HOURS. COORDINATE AND VERIFY EXACT TIMING OF WORK WITH COR. CLOSE DOWN OF

THESE AREAS DURING BUSINESS HOURS WILL NOT BE PERMITTED UNLESS WRITTEN

PERMISSION IS OBTAINED FROM THE COR. ALL WORK IN THESE AREAS SHALL BE SCHEDULED

AND ARRANGED SO THAT THESE AREAS CAN BE OPEN DURING BUSINESS HOURS TO MAINTAIN

HOSPTIAL OPERATIONS AND TO ALLOW PUBLIC TRAFFIC. AT THE END OF EACH WORK SHIFT,

CONTRACTOR SHALL THOROUGHLY CLEAN WORK AREAS, PROTECT WORK, AND PROVIDE

COVER BOARD OR OTHER APPROPRIATE PROTECTION AS REQUIRED AND AS REQUESTED BY

COR PRIOR TO RE-OPENING OF THESE AREAS FOR PUBLIC ACCESS.

C. COMPLETE DEMOLITION AND CONSTRUCTION FOR EACH PHASE. CONTRACTOR SHALL OBTAIN

ACCEPTANCE FROM GOVERNMENT PRIOR TO BEGINNING WORK IN THE NEXT CONSTRUCTION

PHASE.

4. WORK IN EXISTING TOILET ROOMS

A. ALL WORK IN EXISTING TOILET ROOMS SHALL BE EXECUTED IN A MINIMUM TOTAL OF SIXTEEN

(16) CONSTRUCTION PHASES. CONSTRUCTION PHASES AREAS ARE NOT SHOWN ON DRAWINGS,

CONTRACTOR SHALL COORDINATE EXACT NUMBER OF PHASES, AREAS AND BOUNDARIES FOR

EACH PHASE, AND SEQUENCES OF PHASES IN FIELD WITH CONTRACTING OFFICER'S

REPRESENTATIVE (COR). ADDITIONAL CONSTRUCTION PHASES AS REQUIRED BY COR OR AS

RESULT OF FIELD CONDITION SHALL NOT INCREASE CONTRACT COST. AT EACH CONSTRUCTION

PHASE, NO MORE THAN TWO TOILET ROOMS SHALL BE SHUT DOWN.

B. TOILET ROOMS CONSTRUCTION PHASES ARE INDEPENDENT OF CORRIDORS / LOBBIES WORK

CONSTRUCTION PHASES, TOILET ROOMS CONSTRUCTION PHASE CAN EXECUTE

CONCURRENTLY WITH CORRIDORS / LOBBIES CONSTRUCTION PHASES.

C. ALL WORK IN EXISTING TOILET ROOMS SHALL BE PERFORMED DURING BUSINESS HOURS.

D. COMPLETE DEMOLITION AND CONSTRUCTION FOR EACH PHASE, CONTRACTOR SHALL OBTAIN

CERTIFICATE FOR GOVERNMENT MOVE-IN PRIOR TO BEGINNING WORK IN THE NEXT

CONSTRUCTION PHASE.

B100

B101

N

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

FOURTH FLOOR AREA OF WORK AND

CONSTRUCTION PHASING PLAN

G0-3.4

100 / 101

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMChecker

4 FOURTH FLOOR AREA OF WORK AND CONSTRUCTION PHASING PLAN

DN

UP

DN

DN

8910111213

141516

E

F

G

H

I

J

7 6

J.2

7.8

K

I.3

I.5

8.59.9

(E) CORRIDOR

B1-C22

(E) CORRIDOR

B1-C24

(E) CORRIDOR

B1-C21

(E) CORRIDOR

B1-C23

(E) CORRIDOR

F1-C02

(E) CORRIDOR

F1-C05

(E) CORRIDOR

F1-C06

(E) CORRIDOR

A1-C14

(E) ELEVATOR

LOBBY

A1-C15

(E) CORRIDOR

C1-016

(E) ELEVATOR

LOBBY

C1-C17

(E) CORRIDOR

D1-C04

(E) CORRIDOR

D1-C03(E) CORRIDOR

D1-C14

(E) INFOMATION

B1-100

(E) LOBBY/WAIT

B1-C10

(E) FEMALE

TOILET

C1-373

(E) CORRIDOR

F1-C03

(E) MALE TOILET

F1-123

(E) FEMALE

TOILET

F1-121

ALL GENDER

TOILET

F1-236

ALL GENDER

TOILET

F1-238

(E) MALE TOILET

C1-371

(E) ELEVATOR

LOBBY

B1-C20

ALL GENDER

TOILET

F1-122

AS4-1A

AS4-1A

AS4-1A

AS4-1A

REMOVE (E) PORCELAIN

TILE FLOORING AND

BASE, TYP.

D1-C02

(E) CORRIDOR

D1-100

(E) TRAVEL

D1-201

(E) PATIENT

LOCKER

D1-C10

(E) CORRIDOR

D1-200

(E) NS

D1-236

(E) LAB

D1-238

(E) PROC 01

D1-C12

(E) CORRIDOR

D1-231

(E) CH RES

E1-120

(E) OPEN IP &

OP PHARMACY

E1-???

(E) IV PREP

E1-EC4

(E) ELEC

E1-TC4

(E) TEL / DATA

E1-140

(E) VAULT / SEC

/ DISP / FLAM

E1-105

(E) INVEST

DRUGS

E1-103

(E) IV WKRM

E1-C01

(E) CORRIDOR

E1-101

(E) DP

E1-100

(E) OUTPATIENT

PHARMACY

E1-110

(E) CONS

E1-210

(E) OUTPATIENT

PHARMACY

SERVICE ADMIN

OFFICE

E1-200

(E) EDUC

OFFICE

F1-C01

(E) CORRIDOR

F1-100

(E) PATIENT

COFFEE ROOM

F1-110

(E) VOL

SERVICE

F1-120

(E) BLOOD

DRAW ROOM

F1- 115

(E) RELEASE OF

INFO

C1-115

(E) CONSULT

ROOM

C1-11

(E) CONSULT

ROOM

C1-109

(E) PROCESS 1

C1-105

(E) MED/TMT C1-103

(E) FEMALE

TOILET

C1-100

(E) WAIT

C1-117

(E) EXAM 29

C1-119

(E) EXAM 28

C1-C14

(E) CORRIDOR

C1-129

(E) EXAM 27

C1-363

(E) BMS

STORAGE

D1-110

(E) CO-PAY

D1-120

(E) AGENT

CASHIER

D1-C01

(E) VESTIBULE

D1-207

(E)

PHOTOGRAPHY

C1-C07

(E) STAFF

TOILET

D1-205

(E) TUB 1

(E) TERRAZZO

FLOORING AND

BASE TO

REMAIN, TYP.

REMOVE (E)

PORCELAIN TILE

BASE AT

COLUMN

FURRING, TYP.

(E) HANDRAILS

TO REMAIN, TYP.

(E) WOOD

PANELING TO

REMAIN, TYP.

REMOVE (E) CERAMIC TILE

WAINSCOT, CUT AND

REMOVE (E) GYP. BD. AS

REQUIRED FOR NEW

CONSTRUCTION, TYP.

REMOVE (E)

PORCELAIN TILE BASE

AT ALL (E) COLUMNS

IN LOBBY, TYP.

REMOVE (E

) C

ERAMIC

W

ALL

TILE

FIN

ISH, C

UT A

ND R

EMOVE (E

GYP. B

D. A

S R

EQUIR

ED FOR N

EW

CONSTRUCTIO

N

REMOVE (E)

PORCELAIN TILE

BASE AT WINDOW

SILL, TYP.

(E) CRASH RAILS TO

REMAIN, TYP.

(E) CRASH RAILS

TO REMAIN, TYP.

REMOVE (E)

PORCELAIN TILE

BASE AT COLUMN

FURRING, TYP.

(E) HANDRAILS TO

REMAIN, TYP.

REMOVE (E) CERAMIC WALL TILE,

STAINLESS STEEL CORNER, AND

SIGNAGE PANEL, TYP.

REMOVE (E)

WALL

MOUNTED

SIGNAGE

REMOVE (E)

WALL

MOUNTED

SIGNAGE

REMOVE (E)

CERAMIC WALL

TILE, STAINLESS

STEEL CORNER,

AND SIGNAGE

PANEL, TYP.

REMOVE (E

CERAMIC

FLO

OR TILE

S, TYP.

REMOVE (E)

CORNER GUARD

COVER, (E)

CORNER GUARD

RETAINER TO

REMAIN, TYP.

REMOVE (E)

RESILIENT FLOORING

(E) HANDRAILS TO

REMAIN, TYP.

REMOVE (E) CORNER

GUARD COVER, (E)

CORNER GUARD RETAINER

TO REMAIN, TYP.

REMOVE (E) PORCELAIN

TILE FLOORING AND

BASE, TYP.

REMOVE (E) CORNER GUARD

COVERS, (E) CORNER GUARD

RETAINER TO REMAIN, TYP.

REMOVE (E) CERAMIC

WALL TILE,

STAINLESS STEEL

CORNER, AND

SIGNAGE PANEL, TYP.

REMOVE (E) PORCELAIN

TILE FLOORING AND

BASE, TYP.

REMOVE (E)

PORCELAIN

TILE FLOORING

AND BASE, TYP.

REMOVE (E)

PORCELAIN

TILE FLOORING

AND BASE, TYP.

REMOVE (E)

WALK-OFF

MAT SYSTEM

DEMOLITION NOTES1

1. DO NOT PROCEED WITH DEMOLITION WORK PRIOR TO THE INSTALLATION OF TEMPORARY CONSTRUCTION PARTITION.

PROVIDE ACCESS DOORS AT TEMPORARY CONSTRUCTION PARTITION AS REQUIRED FOR ACCESS INTO THE CONSTRUCTION AREA. ACCESS DOORS ARE NOT SHOWN ON PLAN. RELOCATE TEMPORARY CONSTRUCTION PARTITION AS NECESSARY FOR CONSTRUCTION WORK AND AS DIRECTED BY COR AT NO ADDITIONAL COST TO THE GOVERNMENT.

2. PROVIDE TEMPORARY CONSTRUCTION PARTITION IN EXISTING OCCUPIED AREAS AS REQUIRED AND AS DIRECTED BY COR.

TEMPORARY CONSTRUCTION IN EXISTING OCCUPIED AREAS ARE NOT SHOWN. COORDINATE EXACT LOCATION WITH COR.

3. VERYIFY EXTENT OF DEMOLITION PRIOR TO BEGINNING DEMOLITION WORK.

4. CONTRACTOR SHALL PROTECT ALL EXISTING COMPONENTS OF EXTERIOR GLAZING SYSTEM. OTHER EXISTING CONSTRUCTION AND EXISTING LIFE/SAFETY CONSTRUCTION NOT INCLUDED IN THIS CONTRACT. IF THERE IS ANY DAMAGE TO EXISTING GLAZING SYSTEM, OTHER EXISTING CONSTRUCTION AND EXISTING LIFE/SAFETY CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND RESTORATION OF SUCH CONSTRUCTION TO THE ORIGINAL

CONSTRUCTION AT NO ADDITIONAL COST TO THE GOVERNMENT.

5. COMPLETE DEMOLITION OF EXISTING FLOORING IN ALL TOILET ROOMS, CORRIDORS, ELEVATOR LOBBIES, AND AREAS AS SHOWN, UNLESS OTHERWISE NOTED. ALL FLOORING MATERIALS ARE TO BE REMOVED TO TOP OF EXISTING SLAB. TOP OF EXISTING SLAB SHALL BE LEFT SMOOTH, CLEAN AND FREE OF ALL ADHESIVE AND READY FOR INSTALLATION OF NEW

FLOORING.

6. COMPLETE DEMOLITION OF EXISTING CEILING AND SOFFIT IN ALL TOILET ROOMS AND AREAS AS SHOWN, UNLESS OTHERWISE NOTED. ALL CEILING MATERIALS, SUPPORTS AND BRACINGS, ACCESSORIES, AND FIXTURES ARE TO BE

DEMOLISHED.

7. REMOVE EXISITNG FINISHES, FURRINGS, PARTITIONS, CASEWORK, EQUIPMENT, AND ETC. WHERE SHOWN DASHED.

EXISTING FURRING AROUND COLUMNS SHALL REMAIN UNLESS OTHERWISE NOTED OR SHOWN.

8. AT EXISTING WALL OR COLUMN FINISHES TO REMAIN, CUT AND REMOVE EXISTING FINISH AS REQUIRED FOR NEW CONSTRUCTION, PATCH FINISH TO MATCH EXISTING IN CONSTRUCTION, MATERIAL, AND FINISH, UNLESS OTHERWISE

NOTED OR SHOWN.

9. ALL WORK IN (E) CORRIDORS, WORK IN OCCUPIED SPACE, REMOVAL OF DEMOLITION AND CONSTRUCTION DEBRIS, AND WORK THAT INDUCES LOUD NOISE, INCLUDING BUT NOT LIMITED TO CORING, DRILLING, FRAMING FASTENING, ETC. TO BE

PERFORMED DURING BUSINESS OFF-HOURS. COORDINATE EXACT TIMING WITH COR.

10. PATCH TO MATCH EXISTING FLOORS, CEILINGS, WALL, PARTITIONS, AND OTHER ITEMS THAT ARE DAMAGED RESULTING FROM DEMOLITION WORK AND NEW CONSTRUCTION WORK. PATCHWORK SHALL MATCH EXISTING ADJACENT IN TYPE, CONSTRUCTION, MATERIAL, FIRE-RESISTIVE RATING, AND FINISH.

11. PROVIDE SUPPORTS AND BRACES AS REQUIRED, FOR EXISTING STRUCTURE, UTILITIES, PIPES, DUCTS, CONDUITS, AND ETC., DURING DEMOLITION AND NEW CONSTRUCTION WORK WHERE EXISTING SUPPORTS ARE REMOVED DUE TO WORK

UNDER THIS CONTRACT. NEW SUPPORTS SHALL MEET CURRENT CODE REQUIREMENTS.

12. VA TO REMOVE ALL SIGNAGES, ARTWORK, PAINTINGS, AND ETC. ON SURFACE TO BE DEMOLISHED OR MODIFIED.

CONTRACTOR TO COORDINATE WITH VA PRIOR TO THE BEGINNING OF WORK.

13. CONTRACTOR SHALL PROTECT ALL EXISTING ARTWORK, PAINTING, ETC. ON EXISTING PARTITIONS, SOFFIT, AND CEILING TO REMAIN. IF THERE IS ANY DAMAGE TO EXISTING ARTWORK, PAINTING, ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR, RESTORATION, AND REPLACEMENT OF SUCH ARTWORK OR PAINTING AT NO ADDITIONAL COST TO THE

GOVERNMENT.

14. FOR DEMOLITION OF UTILITY SYSTEMS AND FIXTURES, REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION AND

ELECTRICAL DRAWINGS.

15. WHERE EXISTING CONSTRUCTION, IMPROVEMENTS, FINISHES, AND / OR BUILDING SYSTEMS ARE DAMAGED OR REMOVED AS A RESULT OF THE NEW WORK, PATCH EXISTING TO MATCH EXISTING ADJACENT IN TYPE, CONSTRUCTION, MATERIAL, FIRE-RESISTIVE RATING, AND FINISH.

16. REMOVE (E) DOOR STOP AS REQUIRED FOR NEW CONSTRUCTION, SALVAGE, AND RE-INSTALL AT THE SAME LOCATION.

17. AT TOILET ROOMS WITH (E) DOOR OPERATOR, CONTRACTOR TO DE-ACTIVATE AND REMOVE DOOR OPERATOR BUTTON AS

REQUIRED FOR NEW CONSTRUCTION, SALVAGE, AND RE-INSTALL AT THE SAME LOCATION.

18. REMOVE (E) CORNER GUARD COVERS, (E) CORNER GUARD RETAINERS TO REMAIN, TYPICAL, UNLESS OTHERWISE NOTED.

NOT ALL (E) CORNER GUARDS ARE SHOWN ON DRAWINGS, CONTRACTOR SHALL VERIFY EXACT NUMBERS IN FIELD.

19. REMOVE AND RELOCATE EXISTING FLOOR OR WALL MOUNTED EQUIPMENT AS REQUIRED FOR NEW CONSTRUCTION. NOT ALL EQUIPMENT ARE SHOWN, CONTRACTOR SHALL VERIFY ALL EXISTING EQUIPMENT IN FIELD. COORIDINATE WITH COR FOR LOCATION OF TEMPORARY RELOCATED EXISTING EQUIPMENT. AT COMPLETION OF CONSTRUCTION, RE-INSTALL

EXISTING EQUIPMENT AT THE SAME LOCATION.

LEGEND

AREAS WHERE NO

WORK TO BE DONE

(E) PORCELAIN FLOOR

TILE AND BASE TILE TO

BE REMOVED

B100

B101

N

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

BUILDING 100 FIRST FLOOR PLAN -

DEMOLITION

AS1-1A

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMMMC

100% SUBMITTAL 1/8" = 1'-0"

4 BUILDING 100 FIRST FLOOR DEMOLITION PLAN

171.2.3.4.5.6.7.8.9.10.

0.30.7

J.1

B.

C.

C.5

K.

L.

M.

N.

(E) CORRIDOR

B1-C01

(E) MALE TOILET

B1-120

(E) FEMALE

TOILET

B1-122

(E) VESTIBULE

B1-C11

(E) ELEVATOR

LOBBY

B1-C02

(E) CORRIDOR

B1-C03

(E) CORRIDOR

A1-C01

(E) CORRIDOR

A1-C30

(E) BRIDGE

A1-C10

(E) FOOD

SERVICE

C1-204

(E) VESTIBULE

C1-202

(E) ENTRY

C1-200

(E) CORRIDOR

B1-C10

REMOVE (E) CERAMIC TILE

FINISH, CUT AND REMOVE

(E) GYP. BD. AS REQUIRED

FOR NEW CONSTRUCTION,

TYP.

C1-206

(E) FOOD

SERVICE

C1-220

(E) FOOD PREP

A1-EC1

(E) ELEC

A1-TC1

(E) TEL / DATA

C1-201

(E) VESTIBULE

A1-210

(E) CREDIT

UNION

A1-110

(E) RETAIL

STORE

A1-100

(E) STORAGE

A1-121

(E) EUCH

A1-120

(E) CHAPLAIN

SERVICE

A1-122

(E) CHAPL 7

A1-130

(E) SACRISTY

A1-132

CHAPEL

B1-100

(E) AUDITORIUM

C1-234

(E) KITCHEN

C1-203

(E) COFFEE

SHOP

C1-C01

(E) CORRIDOR

(E) WOOD WALL PANELING

TO REMAIN, TYP.

REMOVE (E

) C

ERAMIC

W

IS

H, C

UT A

ND

REMOVE (E

) G

YP. B

D. A

S

REQUIR

ED FOR N

(E) TERRAZZI

FLOORING

AND BASE TO

REMAIN, TYP.

(E)

HANDRAILS

TO REMAIN,

TYP.

REMOVE (E) PORCELAIN

TILE FLOORING AND

BASE TYP.

(E) HANDRAILS

TO REMAIN, TYP.

REMOVE (E)

PORCELAIN

TILE FLOORING

AND BASE TYP.

REMOVE (E)

PORCELAIN

TILE FLOORING

AND BASE TYP.

(E) HANDRAILS TO

REMAIN, TYP.

REMOVE (E)

PORCELAIN

TILE BASE AT

COLUMN

FURRING, TYP.

REMOVE (E)

PORCELAIN

FLOORING AND

BASE, TYP.

REMOVE (E) FLOOR

EXPANSION JOINT

COVER

REMOVE (E)

FLOOR MOUNTED

WAYFINDNG

MONUMENTAL

SIGN

REMOVE (E) CORNER GUARD

COVERS, (E) CORNER GUARD

RETAINER TO REMAIN, TYP.

(E) CRASH

RAILS TO

REMAIN, TYP.

REMOVE (E) WALK-OFF

MAT SYSTEM

NOTES19

1. REFER TO SHEET AS1-1A FOR NOTES UNLESS OTHERWISE NOTED.

LEGEND

AREAS WHERE NO

WORK TO BE DONE

(E) PORCELAIN FLOOR

TILE AND BASE TILE TO

BE REMOVED

B100

B101

N

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

BUILDING 101 FIRST FLOOR PLAN -

DEMOLITION

AS1-1B

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMMMC

100% SUBMITTAL 1/8" = 1'-0"

4 BUILDING 101 FIRST FLOOR DEMOLITION PLAN

8910111213

E

F

G

7 67.88.58.79.9

(E) CORRIDOR

B2-C24

(E) ELEVATOR

LOBBY

B2-C20

(E) CORRIDOR

B2-C21

(E) CORRIDOR

B2-C22

(E) CORRIDOR

B2-C23

ALL GENDER

TOILET

C2-104

ALL GENDER

TOILET

C2-106

ALL GENDER

TOILET

F2-203

ALL GENDER

TOILET

F2-201

AS4-2A

AS4-2A

(E) CORRIDOR

F2-C01

(E) CORRIDOR

C2-C01

D2-100

(E) AUD

STORAGE 1

D2-C01

(E) CORRIDOR

E2-110

(E) OFFICE

E2-100

(E)

NEPHROLOGY

E2-100C

(E) CHIEF

E2-200

(E) WAIT

E2-301

(E) HYG 2

E2-C20

(E) CORRIDOR

F2-100

(E) PULMONARY

F2-130

(E) STF PHYS

F2-132

(E) STF PHYS

F2-134

(E) STF PHYS

F2-136

(E) CHIEF

F2-202

(E) HS

A2-C10

(E) ELEVATOR

LOBBY

A2-C09

(E) CORRIDOR

A1-178

(E) FAMILY

WAIT

A2-100

(E) SOCIAL WK

A2-C01

(E) CORRIDOR

B2-TC2

(E) TEL / DATA

B2-EC2

(E) ELEC

B2-C01

(E) CORRIDOR

C2-174

(E) PHYS / CONS

C2-176

(E) N SUPV C2-100

(E) VIS LOUNGE

B2-150

(E) BIOCHEM

LAB

B2-136

(E) CHEM

B2-C05

(E) CORRIDOR

C2-C10

(E) ELEVATOR

LOBBY

C2-C09

(E) CORRIDOR

E2-C30

(E) CORRIDOR

REMOVE (E

) C

ERAMIC

W

IS

H, C

UT A

ND R

EMOVE (E

) G

YP.

BD. A

S R

EQUIR

E FOR N

REMOVE (E) PORCELAIN

TILE FLOORING AND

BASE, TYP.

REMOVE (E) CARPET

(E) CRASH RAILS TO

REMAIN, TYP.

REMOVE (E)

PORCELAIN TILE

BASE AT

COLUMN

FURRING, TYP.

(E) CRASH RAILS

TO REMAIN, TYP.

REMOVE (E)

PORCELAIN TILE

BASE AT COLUMN

FURRING, TYP.

REMOVE (E)

PORCELAIN TILE BASE

AT WINDOW SILL, TYP.

(E) HANDRAILS

TO REMAIN, TYP.

(E) HANDRAILS TO

REMAIN, TYP.

REMOVE (E) CERAMIC WALL TILE,

STAINLESS STEEL CORNER, AND

SIGNAGE PANEL, TYP.

REMOVE (E)

WALL

MOUNTED

SIGNAGE

REMOVE (E)

WALL

MOUNTED

SIGNAGE

REMOVE (E)

CERAMIC WALL

TILE, STAINLESS

STEEL CORNER,

AND SIGNAGE

PANEL, TYP.

(E) HANDRAILS TO

REMAIN, TYP.

REMOVE (E) CORNER

GUARD COVERS, (E)

CORNER GUARD

RETAINERS TO REMAIN,

TYP.

REMOVE (E) CERAMIC

WALL TILE, STAINLESS

STEEL CORNER , AND

SIGNAGE PANEL, TYP.

CORE DRILL (E) CONC. SLAB

FOR FLOOR MOUNTED ELEC.

OUTLET, COORDINATE WITH

THE FURNITURE LAYOUT AND

EXACT LOCATION WITH VA

REMOVE (E)

PORCELAIN TILE

FLOORING AND

BASE, TYP.

REMOVE (E)

PORCELAIN TILE

FLOORING AND

BASE, TYP.

NOTES19

1. REFER TO SHEET FOR NOTES UNLESS OTHERWISE NOTED.

LEGEND

AREAS WHERE NO

WORK TO BE DONE

(E) PORCELAIN FLOOR

TILE AND BASE TILE TO

BE REMOVED

B100

B101

N

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

NOTES: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

KEY PLAN

A R C H I T E C T S

239 9TH STREET SAN FRANCISCO, CA 94103

T 415.703.0328 F 415.707.6328 www.meiarchitects.com

1001 Connecticut Avenue, N.W. Suite 704, Washington, DC 20036 T 202.817.9371 www.concoursecompanies.com

BUILDING 100 SECOND FLOOR PLAN -

DEMOLITION

AS1-2A

REPLACE BUILDING 100/101

FLOORING REPAIR

640-16-114

November 2, 2018

VAPAHCS - PALO ALTO

MEI TEAMMMC

100% SUBMITTAL 1/8" = 1'-0"

4 BUILDING 100 SECOND FLOOR DEMOLITION PLAN

AS1-1A

UPDN UPDN

8910111213

E

F

G

H

I

J

7 6

J.2

7.8

K

I.3

I.5

8.58.79.9

ALL GENDER

TOILET

F3-243

ALL GENDER

TOILET

F3-241

(E) CORRIDOR

B3-C21

(E) ELEVATOR

LOBBY

B3-C20

(E) CORRIDOR

B3-C24

(E) CORRIDOR

B3-C23

(E) CORRIDOR

B3-C22

ALL GENDER

TOILET

C3-104

ALL GENDER

TOILET

C3-106

AS4-2A

AS4-2A

(E) CORRIDOR

C3-C01

(E) CORRIDOR

F3-C01

REMOVE (E

) C

ERAMIC

W

H, C

UT A

ND R

EMOVE (E

) G

YP.

BD. A

S R

EQUIR

REMOVE (E

) C

ERAMIC

W

H, C

UT A

ND R

EMOVE (E

) G

YP.

BD. A

S R

EQUIR

REMOVE (E) PORCELAIN

TILE FLOORING AND

BASE, TYP.

REMOVE (E) CARPET

(E) CRASH RAILS TO

REMAIN, TYP.

REMOVE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .