About this file

36C26118R0050 00006 36C18R0050 010000 Outage Hours Attach 1.pdf

View the file

Other files

File Type Posted
36C26118R0050-00007002.pdf PDF
36C26118R0050-00007000.docx DOCX document
36C26118R0050-00007003.pdf PDF
36C26118R0050-00007004.pdf PDF
36C26118R0050-00007001.pdf PDF
36C26118R0050-00006000.docx DOCX document
36C26118R0050-00006002.pdf PDF
36C26118R0050-00005001.pdf PDF
36C26118R0050-00005000.docx DOCX document
36C26118R0050-00005002.pdf PDF
36C26118R0050-00005003.pdf PDF
36C26118R0050-00004001.docx DOCX document
36C26118R0050-00004003.docx DOCX document
36C26118R0050-00004004.docx DOCX document
36C26118R0050-00004000.docx DOCX document
36C26118R0050-00004002.docx DOCX document
36C26118R0050-00003001.pdf PDF
36C26118R0050-00003000.docx DOCX document
36C26118R0050-00003002.pdf PDF
36C26118R0050-00002000.docx DOCX document
36C26118R0050-00002001.pdf PDF
36C26118R0050-00001000.docx DOCX document
36C26118R0050-006.pdf PDF
36C26118R0050-063.pdf PDF
36C26118R0050-045.docx DOCX document
36C26118R0050-033.docx DOCX document
36C26118R0050-052.docx DOCX document
36C26118R0050-061.pdf PDF
36C26118R0050-023.docx DOCX document
36C26118R0050-029.docx DOCX document
36C26118R0050-024.docx DOCX document
36C26118R0050-054.docx DOCX document
36C26118R0050-037.docx DOCX document
36C26118R0050-015.docx DOCX document
36C26118R0050-058.docx DOCX document
36C26118R0050-065.pdf PDF
36C26118R0050-036.docx DOCX document
36C26118R0050-019.docx DOCX document
36C26118R0050-021.docx DOCX document
36C26118R0050-040.docx DOCX document
36C26118R0050-017.doc DOC document
36C26118R0050-025.docx DOCX document
36C26118R0050-042.docx DOCX document
36C26118R0050-032.doc DOC document
36C26118R0050-056.docx DOCX document
36C26118R0050-009.docx DOCX document
36C26118R0050-050.docx DOCX document
36C26118R0050-035.docx DOCX document
36C26118R0050-010.docx DOCX document
36C26118R0050-041.docx DOCX document
Show 40 more

Latest 50 of 92 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Relocate Boiler Plant Electrical Room Project 654-16-632

GENERAL REQUIREMENTS

01 00 00 -6 arranged, contractor work hours are limited to 7:30 a.m. to

4:00 p.m.

10.Utility shutdown. No utility shutdowns will be allowed without proper prior coordination with the medical center. Minor utility shutdowns (those which in no way impact patient care activities) are to be scheduled no less than Seven (7) days in advance of the planned shutdown. Major utility shutdowns

(those which do impact patient care activities or must occur after hours) are to be formally requested no less than 21 days in advance of the requested shutdown.

a) The duration of a minor utility shutdown shall be no longer than Four (4) hours.

b) The duration of a major utility shutdown shall be no longer then Eight (8) hours.

11.Contractor’s staging area. There is limited space available for the contractor to use as a staging location. Unless otherwise noted in the contract drawings or specifications, all staging of equipment and materials is to occur within the boundaries of the limits of construction as shown on the contract documents. Dumpster/Storage Area on VA property is not permitted except within the boundaries of the construction project. Coordination for street use for dumpsters and storage is between the contractor and the City of Reno.

12.Crane Operations. Crane Operations are not permitted over occupied areas. Crane operations should be scheduled when occupants are not routinely under the crane ops area. All crane operations require submission of a crane lift permit utilizing the template provided by the VA and attached to this specification. Areas of more impact will require greater advanced scheduling. The crane lift permit is an Attachment at the end of this Section.

13.Fire alarm or fire sprinkler work and/or tie-ins. No removal, relocation, disconnection, disabling or connection to the existing facility fire alarm or fire sprinkler systems are to occur until the contractor has obtained the approval of the

VHARENHARRIC

Text Box 36C26118R0050 Amend 0006

File details come from the government source that posted it.