Attachment 2 - Drawings 653-26-110 Building 17 HR Remodel.pdf

PDF 311 KB Posted

Attached to
Y1DZ--653-26-110 Light Remodel Bldg 17
Solicitation number
36C26027R0033
Issued by

About this file

This document is an architectural floor plan for Building 17 Human Resources Project Overview. The plan depicts a true north view of the facility with labeled rooms and spaces, including net square footage (NSF) measurements for each area. Key administrative spaces include an Executive Office (561.1 NSF), Director Office (231.8 NSF), Chief of Staff Office (203.4 NSF), Conference Room (283.8 NSF), and Recruitment Office (527.2 NSF). The layout also identifies support areas such as bathrooms, break rooms, storage closets, electrical rooms, mechanical chases, and IT closets distributed throughout the building footprint.

The floor plan indicates several renovation and maintenance activities required for the project, including raising flooring approximately 21 inches in specified areas, repairing doors, removing and replacing sinks, replacing blinds, furring out walls in multiple locations, and updating bathrooms per the Statement of Work (SOW). A color-coded legend and detailed room numbering system are provided, with a highlighted red boundary delineating the primary project scope area. The document serves as a visual reference for spatial organization and scope of work definition for the Human Resources facility renovation project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T R

U E

N O

R T

H

P

LA

N V

IE

W

D N

B

16.5 N

SF

STO

R

AG

E

B

163.4 N

SF

ASSO

C

IATE D

IR

EC

TO

R

B

203.4 N

SF

ASSO

C

IATE D

IR

EC

TO

R

PATIEN

T C

AR

E SVC

B

187.0 N

SF

C H

IEF O

F STAFF

B

231.8 N

SF

D

IR

EC

TO

R O

FFIC

E

B

117.2 N

SF

EXEC

U

TIVE

ASSISTAN

T D

IR

EC

TO

R

B

108.5 N

SF

EXEC

U

TIVE

ASSISTAN

T

AD

/PTC

AC

E

SVC

O

FFIC

E

B

115.8 N

SF

EXEC

U

TIVE

ASSISTAN

T C

H

IEF O

F STAFF

B

561.1 N

SF

EXEC

U

TIVE O

FFIC

E

E108

318.5 N

SF

H

ALL

B 103B

8.3 N

SF

STO

R

AG

E

B

145.7 N

SF

BR

EAK R

M

B

245.8 N

SF

C O

N

FER

EN

C

E

8.0 N

SF

C

H

ASE

9.1 N

SF

C

H

ASE

B

55.8 N

SF

TO

ILET

B

63.5 N

SF

TO

ILET

B 104A

3.1 N

SF

FIR

E C

LO

SET

O U

T O

F SER

VIC

E

B

.8 N S

F H

A C

E109

119.6 N

SF

ELEC

TR

IC

AL R

M

B 109B

33.1 N

SF

VESTU

BU

LE

B 109A

43.8 N

SF

STO

R

AG

E

B

315.2 N

SF

STO

R

AG

E

A 106C

255.8 N

SF

O

FFIC

E

ID

C

AR

D

2760.5 N

SF

C

O U

R

TYAR

D

E102

36.3 N

SF

STAIR

A

57.8 N

SF

IT C

LO

SET

A 118A

100.9 N

SF

IN

FO

R M

ATIO

N

SYSTEM

O

FFIC

E

A

141.2 N

SF

O

FFIC

E

A

134.4 N

SF

O

FFIC

E

A

134.4 N

SF

O

FFIC

E

A

112.4 N

SF

O

FFIC

E

A

146.2 N

SF

O

FFIC

E

A

527.2 N

SF

R

EC

R U

ITM

EN

T O

FFIC

E

E122

77.8 N

SF

C

O

PY R

M

A

165.7 N

SF

C H

IEF O

F STAFF

O

FFIC

E

A

43.3 N

SF

BATH

R

O O

M "B"

E103A

M

EC

H

9.9 N

SF

C H

ASE

A

81.5 N

SF

BATH

R

O O

M "A"

A

84.5 N

SF

O

FFIC

E

A

122.9 N

SF

R

EC

R U

ITM

EN

T

AN

D

PLAC

EM

EN

T

SU

PER

VISO

R 'S

O

FFIC

E

B

100.0 N

SF

O

FFIC

E

B

110.5 N

SF

O

FFIC

E

B 105A

151.7 N

SF

ASSISTAN

T

ASSO

C

IATIVE

D

IR

EC

TO

R

A

206.7 N

SF

R

EC

EPTIO

N

E107

203.9 N

SF

W

AITIN

G

/LO

BBY

A

283.8 N

SF

C O

N

FER

EN

C

E R M

A

107.2 N

SF

BR

EAK R

M A

156.9 N

SF

EM

PLO

YEE/LABO

U

R R

ELATIO

N

S

A

90.2 N

SF

VISN

R

ETIR

EM

EN

T U N

IT

A

147.6 N

SF

VALVE R

M

A 105A

5.2 N

SF

FIR

E SPR

IN

KLER

VALVE

A

156.5 N

SF

EM

PLO

Y/LABO

U

R R

ELATIO

N

S

E106

419.2 N

SF

H

ALL-

2.7 N

SF

C

H

ASE

SID

EW

ALK

SIDEWALK

R A

IS

E

F L

O O

R

IN

G

12 "

R A

IS

E

F L

O O

R

IN

G

12 "

R E

P A

IR

D

O O

R

D E

M O

S

IN

K

R

EPLAC

E BLIN

D

S

FU

R

O U

T W

ALLS

FU

R

O U

T W

ALLS

FU

R

O U

T W

ALLS

FU

R

O U

T W

ALLS

FU

R

O U

T W

ALLS

U

PD

ATE BATH

R

O O

M

S PER

SO

W

BU

ILD

IN

G

17 H U

M

AN

R

ESO

U R

C

ES PR

O

JEC

T O

VER

VIEW

File details come from the government source that posted it. Updated .