36C26026Q0530.docx
DOCX document 18 KB Posted
- Attached to
- 6540--PHACOEMULSIFICATION UNITS
- Solicitation number
- 36C26026Q0530
About this file
This is a Sources Sought Notice issued by the Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, conducting market research for phacoemulsification units and related surgical equipment for the Portland VA Medical Center in Portland, Oregon. The VA is seeking information from qualified sources regarding the availability and capability to provide Phacoemulsification Units that are brand name or equal to those manufactured by Alcon Vision LLC. The required equipment includes 30 Unity 4D Phaco Handpieces, 3 OZIL Frag Handpieces, 3 UNITY VCS VLTP systems, and various surgical supplies and fluids. Responses must be submitted via email to Contract Specialist Gregory Watson at Gregory.Watson2@va.gov no later than April 20, 2026, at 6:00 PM Pacific Time.
Interested contractors must provide company name, address, business size, point of contact information including name, phone number, and email address, as well as the country of origin for any items not manufactured in the USA. The salient characteristics specify minimum requirements for vitreoretinal surgical capabilities, including a vitrectomy cutter capable of at least 30,000 cuts per minute, real-time intraocular pressure sensing, advanced aspiration modes, RGB multi-channel LED illumination, 27-gauge instrument compatibility, an internal 532 nm laser for retinal photocoagulation with multi-spot capability, and compatible infusion systems. Cataract surgery capabilities must include intelligent dynamic fluidics, surge mitigation functionality, a torsional or advanced phaco handpiece, and real-time thermal sensing at the phaco tip with automatic power modulation. This is a Request for Information only and will assist the Government in determining the appropriate acquisition method. NAICS Code 339112 applies for determining business size standards. The contracting office is located in Vancouver, Washington (zip code 98661).
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| PHACOEMULSIFICATION UNITS |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 98661 |
| SOLICITATION NUMBER* |
| 36C26026Q0530 |
| RESPONSE DATE/TIME/ZONE |
| 04-20-2026 6:00 PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6540 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Network Contracting Office 20 |
ATTN: V4CONT
1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661
POINT OF CONTACT*
Contract Specialist Gregory Watson Gregory.Watson2@va.gov 360-553-7602
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Portland VA Medical Center
3710 SW US Veterans Hospital Rd.
Portland OR
| POSTAL CODE |
| 97239 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/portland-health-care/ |
| URL DESCRIPTION |
| https://www.va.gov/portland-health-care/ |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Gregory.Watson2@va.gov |
| EMAIL DESCRIPTION |
| Contract Specialist |
DESCRIPTION
THIS IS A REQUEST FOR INFORMATION ONLY. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to fulfil a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method.
The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources for:
Phacoemulsification Units for the Portland VAMC. The Phacoemulsification Units are brand name or equal to Phacoemulsification Units manufactured by Alcon Vision LLC.
| Quantity |
| Product Code |
| Description |
| 30 |
| 8065000315 |
| Unity 4D Phaco Handpiece |
| 3 |
| 8065000215 |
| OZIL FRAG HANDPIECE |
| 3 |
| 900484665 |
| UNITY VCS VLTP |
| 1 |
| 8065753167 |
| ASSY,SHIP,VIT 23GA ANT |
| 1 |
| 8065000339 |
| ANTERIOR PAK UCS .9ULTRA 30BAL |
| 1 |
| 8065000393 |
| NG VISCOUS FLUID CONTROL |
| 1 |
| 8065000329 |
| POSTERIOR PAK UVRC 23G BEV 10K S |
| 1 |
| 8065797102 |
| ISPAN C3F8 PERFLUOROPROPANE |
| 1 |
| 8065797002 |
| ISPAN SF6 SULFUR HEXAFLUORIDE 125GM |
Salient Characteristics Phacoemulsification and Vitreoretinal Surgical System:
Vitreoretinal Capabilities (Minimum Requirements)
• Provides a vitrectomy cutter capable of at least 30,000 cuts per minute for efficient vitreous removal.
• Supports compatibility with dual-blade or equivalent high efficiency cutters for close proximity retinal work.
• Maintains stable intraocular pressure (IOP) through real time pressure sensing with independent control of infusion and aspiration, accommodating the range of viscosities encountered in vitreoretinal surgery.
• Provides aspiration modes that allow transition between flow-based and vacuum-based aspiration to support both shave vitrectomy and posterior vitreous detachment techniques.
• Includes technology that detects aspiration occlusion or changes in viscosity and adjusts aspiration rate accordingly to enhance safety and efficiency, including during training scenarios.
• Offers RGB or equivalent multi channel LED illumination with tunable intensity and color profiles, along with independent control for multiple instruments.
• Provides illumination with customizable spectral output to reduce high wavelength exposure (blue/green) and align with aphakic hazard safety profiles.
• Supports compatibility with 27 gauge vitreoretinal instruments.
• Includes an internal 532 nm laser for retinal photocoagulation.
• Supports multi spot laser capability to reduce treatment time, offering selectable spot patterns such as 4 spot, 2 spot, and 1 spot.
• Provides an entry and infusion system designed to reduce trocar insertion force and allow efficient infusion, with compatibility for 3 mm, 4 mm, and 6 mm cannulas.
• Enables rapid setup and teardown, including single step priming and testing or equivalent, with minimal required VR connections.
Cataract Surgery Capabilities (Minimum Requirements)
• Provides intelligent or dynamic fluidics that maintain chamber stability at physiologic IOP levels.
• Includes surge mitigation functionality using pressure sensing and automatic venting to reduce post occlusion surge.
• Includes a torsional or equivalent advanced phaco handpiece intended for efficient lens removal.
• Provides real time thermal sensing at or near the phaco tip with automatic power modulation to prevent corneal wound burns.
Potential candidates having the capabilities necessary to provide the above stated requirement are invited to respond to this Request for Information via e-mail to Gregory Watson at Gregory,Watson2@va.gov no later than 20 April 2026, 06:00 PST. No telephone inquiries will be accepted.
RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: company name, address, and business size; point of contact name, phone number, e-mail address. NAICS Code 339112 is applicable to determine business size standard. In addition please enclose the country of origin for any items not manufactured in the USA. Any questions or concerns may also be directed to Gregory Watson via e-mail.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .