36C26025R0031.docx
DOCX document 34 KB Posted
- Solicitation number
- 36C26025R0031
About this file
This is a Sources Sought notice from the VA Network Contracting Office 20 for renovation work at the Mann-Grandstaff VA Medical Center in Spokane, WA. The project (36C26025R0031) involves control room and imaging room renovations including pipe removal, wall demolition, lead shielding installation, HVAC upgrades, structural analysis, floor replacement, and asbestos abatement.
The estimated project value is $1-2 million with a 214-day period of performance. Responses are due by December 11, 2024, at 10:00 AM PST. The opportunity uses NAICS code 236220 with a $45 million size standard. Contractors must comply with Buy American requirements and provide manufacturer representatives for installation verification and testing. Response packages are limited to 2 pages and must include contact information, business classification, capabilities statement, timeline estimates, product details, and up to three past performance examples from the last 5 years. The VA will use responses to shape the eventual acquisition strategy, though responding to this notice is not required for participation in any future solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1 668-CSI-009 SOW.docx | DOCX document | |
| Attachment 2 668-CSI-009 Specifications.pdf | ||
| Attachment 3 668-CSI-009 Drawings.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought - Solicitation Number: 36C26025R0031, Project 668-CSI-009 Renovate C208G/F for IR/RF
| SUBJECT* |
| 36C26025R0031 668-CSI-009 Renovate C208G/F for IR/RF |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 98661 |
| SOLICITATION NUMBER* |
| 36C26025R0031 |
| RESPONSE DATE/TIME/ZONE |
| 12-11-2024 10am PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| Z2DA |
| NAICS CODE* |
| 236220 |
| CONTRACTING OFFICE ADDRESS |
| Network Contracting Office 20 |
ATTN: V4CONT
1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661
POINT OF CONTACT*
Contracting Officer Dennis Einarson Dennis.Einarson@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Mann-Grandstaff Department of |
Veterans Affairs Medical Center
4815 N Assembly St
Spokane WA
| POSTAL CODE |
| 99205 |
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
Sources Sought Notice Sources Sought Notice
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
This is a Sources Sought announcement only. This is not a request for proposals, quotations, or bids; nor a synopsis of a proposed contract action under FAR Subpart 5.2 and no contract shall be awarded from this notice. No reimbursement will be made for any costs associated with providing information in response to this Sources Sought or any follow up information requests. No solicitation is currently available. Draft documents (SOW, Drawings, Specifications, etc.) are subject to change. This notice is for market research purposes to gain knowledge of interest, capabilities, and qualifications of interested Small Business firms. Responses to this Sources Sought may shape the acquisition strategy in developing a competitive requirement. Not responding to this notice does not preclude participation in any future or potential solicitation. It is the intent of the VA to use the information gathered for market research purposes only.
Veterans Health Administration, Regional Procurement Office West, Network Contracting Office 20, in support of the Mann-Grandstaff VA Medical Center located in Spokane, WA, is conducting market research for a construction that includes but is not limited to the following renovation:
Control room and imaging room renovations including removing all piping, drains, wall demolition, lead shielded wall and window, and relocating door; removal of half of control room which will require lead shielded wall, and a door to be installed; HVAC to include a new unit for additional airflows, ducting, crane, and electrical; structural analysis; unistruts; floor replacement; asbestos abatement; nights and weekends, and ICRA precautions.
The contractor shall provide a qualified manufacturer’s representative to check complete installation for conformance to manufacturer’s recommendation, to place the system into service, to make all adjustments required for full conformance to design and specified requirements and to perform all demonstrations and testing.
An operating test shall be run in the presence of the Contracting Officer’s Representative (COR), in accordance with the commissioning specifications.
The contractor shall provide Commissioning documentation.
The contractor shall provide demonstration and training to VA personnel.
The contractor shall verify locations for space requirements.
Period of performance is estimated to be 214 days for completion of work.
Documents are currently in draft state and industry comment / suggestions are greatly encouraged and welcomed.
The estimated magnitude for this project is between $1,000,000 and $2,000,000.
Sources are being sought for firms with a North American Industry Classification System (NAICS) code of 236220 - Commercial and Institutional Building Construction, PSC Z2DZ and a with a Small Business Size Standard of $45 million. Sources are highly encouraged to respond to this notice.
After review of the responses to this notice, and if the Government still plans to proceed with this project, a separate pre-solicitation announcement will be published on www.SAM.gov. Responses to this announcement are not an adequate response to any future solicitation announcement.
Responses are requested with the following information and shall not exceed a total of 2 (two) pages. Email subject line needs to contain the solicitation number 36C26025R0031.
Please provide the following information:
1. Contact information: Name, address, SAM.gov UEI number, and points of contact with telephone numbers and e-mail addresses.
2. Business Size/Classification (based on NAICS 236220):
Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program.
[ ] yes [ ] no Small Business (SB) [ ] yes [ ] no HUBZone [ ] yes [ ] no Small Business 8(a) [ ] yes [ ] no Small Disadvantaged Business (SDB) [ ] yes [ ] no Women-Owned (WO) Small Business [ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Other (please specify)
3. Capabilities Statement: Description of capabilities to perform construction services as described above and project experience demonstrating relevant experience similar to those described. Include bonding capability information that is consistent with estimated magnitude.
· Govt. does not have a waiver to Buy American.
· SDVOSB or VOSB businesses please include statement on maintaining compliance with VAAR 852.219-75 VA Notice of Limitations on Subcontracting—Certificate of Compliance for Services and Construction,
· All other socio-economic businesses please include statement on maintaining compliance with FAR 52.219-14 Limitations on Subcontracting.
4. Time: Based on the information provided, please estimate the total project time in days.
5. Products: 52.225-9 Buy American-Construction Materials. Identify any supplies/products that may conflict with the Buy American requirements. Also, identify and any potential supplies/materials with long lead time estimates.
6. Past Performance/experience: Provide information on contracts of similar scopes of work or construction contracts, briefly describe no more than three (3) contracts (or specific task orders) completed within the past five years of the issue date of this Sources Sought notice. The past performance information should include:
· Project Title/Contract Number
· Location: City, State
· General description of the construction to demonstrate relevance to the proposed project
· Offerors’ role
· Dollar value of contract
· Name of the company, agency, or government entity for which the work was performed
· What types of information is required to submit accurate offers?
If submitting past performance/experience on a project in the role of a subcontractor, include the Prime Contractor’s name and a quantifiable amount (percentage) of the project your company contributed to the overall scope of work.
Note: Do not include Proprietary, classified, confidential, or sensitive information in responses.
NO RESPONSES WILL BE ACCEPTED BY FAX.
Responses will not be returned. Telephonic responses will not be honored. Please respond by email only. Send responses to the Contracting Officer, Dennis Einarson, at Dennis.Einarson@va.gov.
Responses will be accepted until December 11, 2024, 10:00 AM PST.
See attached document: Attachment 1 668-CSI-009 SOW.
See attached document: Attachment 2 668-CSI-009 Specifications.
See attached document: Attachment 3 668-CSI-009 Drawings.
Page 1 of Page 1 of
Page 1 of Page 1 of
File details come from the government source that posted it. Updated .