This Sources Sought Notice from the Department of Veterans Affairs seeks market research for installing a sprinkler and water main connection system at Building 16 of the American Lake Campus in Tacoma, WA. The project (663A4-22-202) requires installation of wet fire suppression systems for occupied floors (Covered Patio, 1st and 2nd floors) and dry systems for unoccupied areas, covering approximately 6,000 GSF. The scope includes demolition, new construction, backflow prevention devices, position indicator valve, a two-inch isolation valve for potable water, and Fire Department Connection point.
The project falls under NAICS code 237110 with a size standard of $45.0M, with an estimated value between $500,000-$1,000,000. Work must be completed within 249 calendar days from Notice to Proceed. Responses are due March 10, 2025 at 1300 PST to robert.capers2@va.gov and ty.draszt@va.gov. Interested contractors must provide company information, socio-economic program eligibility, capability statement (max 2 pages), and current bonding capacity. The contract will be managed by NCO 20 Network Contracting Office in Vancouver, WA.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| CON-663A4-22-202 AMLK Install Sprinkler and Water Main Connection to Building 16 |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 98661 |
| SOLICITATION NUMBER* |
| 36C26025Q0304 |
| RESPONSE DATE/TIME/ZONE |
| 03-10-2025 13:00 PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| N042 |
| NAICS CODE* |
| 237110 |
| CONTRACTING OFFICE ADDRESS |
| NCO 20 Network Contracting Office |
ATTN: V4CONT
1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661
POINT OF CONTACT*
Contract Specialist Robert Capers robert.capers2@va.gov
Ty.draszt@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| American Lake Campus |
9600 Veterans Drive Southwest
Tacoma, WA
| POSTAL CODE |
| 98493 |
| COUNTRY |
| US |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/puget-sound-health-care/locations/america |
| URL DESCRIPTION |
| https://www.va.gov/puget-sound-health-care/locations/america |
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
This is a SOURCES SOUGHT NOTICE in support of the Veterans Affairs American Lake Campus, Tacoma, WA for market research purposes only to determine the availability of potential businesses with capabilities to provide the requirement described below.
| Project Name: | Install Sprinkler and Water Main Connection to Building 16 AMLK |
| Project Number: | 663A4-22-202 |
Place of Performance:
American Lake Campus 9600 Veterans Drive Southwest Tacoma, WA 98493 Responses Due: March 10, 2025 @1300 PST Send Response To:
Robert.Capers2@va.gov and Ty.draszt@va.gov Subject “663A4-22-202 Install Sprinkler and Water Main”
Description:
The Contractor shall provide all labor, material, and equipment for demolition, removal, and new construction in the vicinity of Building 16 to provide a wet fire suppression system for the occupied floors of the structure (Covered Patio, 1st and 2nd) and a dry fire suppression system for the unoccupied areas of the facility excluding crawl space. The new system shall provide an adequate back-flow prevention devices, position indicator valve, associated fittings, the addition of a two-inch isolation valve to the buildings main potable water service line, Fire Department Connection (FDC) point, and associated support as details will be provided in the Drawings and Specs.
The new fire suppression system will be servicing approximately 6,000GSF spaces in Building 16.
The materials to be installed shall be new and installed per Manufacturer’s Installation instructions. Complete all work within 249 calendar days from Notice to Proceed (NTP) including final cleaning, inspections, corrections, and demobilization from the project site.
Anticipated North American Industry Classification System (NAICS) code is 237110 Water and Sewer Line and Related Structures Construction. The largest a firm can be and still qualify as a small business for Federal Government programs is a size standard of $45.0M.
Potential contractors shall provide, at a minimum, the following information (1-4):
1) Company name, address, and point of contact, phone number, e-mail address, and DUNS/EUID.
2) Is your firm eligible for participation in one of the following small business socio-economic programs? If so, please indicate the program.
[ ] yes [ ] no Small Business (SB) [ ] yes [ ] no HUBZone [ ] yes [ ] no Small Business 8(a) [ ] yes [ ] no Small Disadvantaged Business (SDB) [ ] yes [ ] no Women-Owned (WO) Small Business [ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Other (please specify)
3) Provide a brief capability statement (Max 2 pages) with enough information to determine if your company can meet the requirement.
4) What your current bonding (performance & payment) capacity? The Magnitude of this Construction Project is anticipated between $500,000 and $1,000,000.
This is not a request for quotes, proposals, or a solicitation.