663-CSI-021 Requests for Information - Responses 001-004.pdf

PDF 100 KB Posted

Attached to
CON 663-CSI-021 Renovation of Bldg. 100 for IR Lab, VAPSHCS, Seattle, WA
Solicitation number
36C26024R0085
Issued by

About this file

This document contains Requests for Information (RFIs) and Government responses related to Solicitation 36C26024R0085 for the renovation of approximately 762 square feet of existing space in the Radiology Department to renovate for the Interventional Radiology (IR) Lab at the VA Puget Sound Health Care System in Seattle, Washington.

The key details are:

  • The Government clarified that all new walls are to be constructed per the provided specifications, and that the cabinetry depicted in the drawings is already installed and not subject to demolition requirements.
  • The Government confirmed that there is no Physical Access Control System work required for this project, as that specification was included in error.
  • This is a general construction project that requires the contractor to furnish all supervision, labor, and materials to prepare the site, perform demolition, and complete the renovation work.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST for PROPOSAL 36C26024R0085 CON 663-CSI-021RENOVATE BLDG 100, 2ND

FLOOR FOR IR LAB REPLACEMENT, VA PUGET SOUND HEALTH CARE SYSTEM

SEATTLE, WASHINGTON

REQUESTS FOR INFORMATION

Government clarification for the following questions 001 thru 004:

1. Drawing A-601, Wall Schedule only depicts one wall type #2. This wall is drawn without acoustical insulation. Will the VA confirm that all new walls are to be constructed without insulation?

VA can confirm that all new walls are to be constructed to provided specifications.

2. Drawing AE421, Elevation #4 depicts new upper and lower cabinets with a countertop. There are no keynotes nor floorplan references, or finish Specifications in Section 09 06 00. Will the VA provide clear directions if these cabinets / countertops are to be fabricated and installed for this project? If so, will the VA provide material / fabrication instructions and specifications for these cabinets?

Drawing AE421, Elevation #4 depicts cabinetry which is already installed at the location. It is not subject to demolition requirements.

3. Drawing AE421, Elevation #4 depicts new upper and lower cabinets with a countertop. At the lower left of the base cabinets there appears either a tall cabinet door or possibly and under the counter refrigerator. If this is a refrigerator, this does not appear on the equipment schedule, and there is no responsibility matrix for who may be supplying and installing this equipment. Will the VA clarify what this cabinet / unit is supposed to be and if a refrigerator, specifications, and who supplies and installs it?

Drawing AE421, Elevation #4 depicts cabinetry which is already installed at the location. It is not subject to demolition requirements.

4. The Specifications contain Section 28 13 00 – Physical Access Control System. Drawing A-601 does not depict any access control in the Door Schedule or details. Will the VA confirm no Physical Access Control work is required for this project?

Specification Section 28 13 00 – Physical Access Control System included in error. There is no such work required for this project.

File details come from the government source that posted it. Updated .