Backflow Survey Oct2025.xlsx
XLSX spreadsheet 14 KB Posted
- Solicitation number
- 36C25926Q0177
About this file
This file is a domestic water backflow prevention device survey conducted at the Sheridan Veterans Affairs Medical Center (VAMC), documenting the inventory and testing status of backflow preventers across multiple buildings and rooms.
The survey identifies approximately 30+ backflow prevention devices distributed across buildings numbered 1 through 90, including specialized facilities such as water plants and mechanical rooms. The devices are predominantly Double Check and Reduced Pressure assembly types, manufactured by Watts, Wilkins, and Febco. Critical findings include multiple devices with unverified status due to access issues (rooms in buildings 7, 9, and 71), several devices lacking identification tags or dated tags (such as a 2003-dated tag in Building 7), and at least one device documented as having failed testing (Building 8, Room 008). Approximately 10-12 devices show "FALSE" values in the "Tested Tag Present" column or carry notes indicating testing could not be verified. The survey provides specific room locations, manufacturer models, and maintenance notes that will inform the scope of backflow preventer testing and repair services required under solicitation 36C25926Q0177 issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25926Q0177 A0001.docx | DOCX document | |
| Attachment 2 - Wage Determination 2015-5411 Rev 27 dated 12-03-2025.pdf | ||
| Attachment 1 - Statment of Work - Backflow Testing.docx | DOCX document | |
| 36C25926Q0177.docx | DOCX document | |
| Attachment 3 - 852.219-75 VA Notice of Limitations on Subcontracting.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1 Sheridan VAMC Domestic Water Backflow Survey
| Building | Room | Assembly Type | Manufacturer | Model | Tested Tag Present | Notes |
| 1 | 005 | Double Check | Watts | 009M2 | FALSE | |
| 1 | 005 | Double Check | Watts | 009M2 | FALSE | |
| 1 | 005 | Double Check | Watts | 009M3 | FALSE | below steam trap 001-B1 |
| 3 | 010 | Reduced Pressure | Wilkins | 375XL | TRUE | |
| 4 | 003C | Double Check | Watts | 007 M2 | TRUE | |
| 4 | 008A | Double Check | Watts | 007M2 | TRUE | |
| 4 | 006 | Double Check | Wilkins | 950XLT | TRUE | Not noted pass or fail |
| 5 | 001 | Double Check | Watts | 009M2 | TRUE | |
| 5 | 001 | Double Check | Watts | 009M2 | TRUE | |
| 6 | 004 | Reduced Pressure | Wilkins | 975XL | TRUE | |
| 7 | 006 | Reduced Pressure | Febco | 860 small | FALSE | Above chiller pump. Tag dated 2003 |
| 7 | 006 | Reduced Pressure | Febco | 860 small | TRUE | In middle of room |
| 7 | 003 | Reduced Pressure | FALSE | Not verified. Couldn’t get access to room | ||
| 7 | 012 | Double Check | Watts | 007DC | TRUE | |
| 8 | 018 | Double Check | Watts | 007m1 | TRUE | |
| 8 | 025 | Reduced Pressure | Wilkins | 950XLT2 | FALSE | |
| 8 | 008 | Double Check | Watts | 007m1 | TRUE | FAIL |
| 9 | 106 | Reduced Pressure | FALSE | not verified. Couldn’t find | ||
| 9 | 109 | Double Check | FALSE | not verified couldn’t access room. | ||
| 64 | 001B | Double Check | Wilkins | 350 Size 4 | TRUE | |
| 71 | 108A | Reduced Pressure | FALSE | Could Not Verify Could not find. 71N 108 Maybe? | ||
| 71 | 108A | Reduced Pressure | FALSE | Could Not Verify Could not find. 71N 108 Maybe? | ||
| 86 | Double Check | Wilkins | 350 | TRUE | ||
| 86 | Reduced Pressure | wilkins | 375 | TRUE | ||
| 87 | 103 | Double Check | Watts | 007DCDA | TRUE | |
| 87 | 103 | Double Check | Watts | 007M3 | TRUE | |
| 87 | 103 | Double Check | Watts | 009m2 | FALSE | no tag |
| 71N | 113 | Reduced Pressure | Febco | 825y | TRUE | |
| 71N | 113 | Double Check | Febco | 825ID | TRUE | 4inch |
| 31 | 010 | Reduced Pressure | Watts | 009M2 | TRUE | Behind tempered water tank |
| 31 | 010 | Reduced Pressure | Watts | 009m | TRUE | West wall |
| 90 | Base | Reduced Pressure | Watts | 009m | TRUE | |
| 90 | Base | Reduced Pressure | Watts | 009M | TRUE | |
| 90 | Base | Reduced Pressure | Watts | 009M | TRUE | |
| Water Pant | Reduced Pressure | FALSE | Not Verified | |||
| Gillette | Mech | Reduced Pressure | FALSE | Not Verified | ||
| Gillete | Mech | Double Check | FALSE | Not Verified | ||
| FALSE | ||||||
| FALSE | ||||||
| FALSE | ||||||
| FALSE | ||||||
| FALSE | ||||||
| FALSE | ||||||
| FALSE | ||||||
| FALSE | ||||||
| FALSE | ||||||
| FALSE | ||||||
| FALSE |