36C25926Q0011 0001.docx

DOCX document 18 KB Posted

Attached to
J045--ANNUAL BOILER Maintenance Base Plus 4 Option Years for ECHCS
Solicitation number
36C25926Q0011
Issued by

About this file

This document is an Amendment (0001) to a Request for Quote (RFQ) for Annual Boiler Maintenance at the Eastern Colorado Healthcare System (ECHCS). The solicitation is a 100% small business set-aside for NAICS code 238220, seeking a firm-fixed price contract for boiler maintenance with a base year and four option years. The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 19 is seeking a contractor to perform maintenance on boilers located at the Rocky Mountain Regional VA Medical Center in Aurora, Colorado.

Key details include a site visit scheduled for November 6, 2025, at 10:00 AM MT, with the quote response deadline extended to November 13, 2025, at 14:00 MT. The scope of work involves comprehensive boiler maintenance, including testing and potential replacement of eight relief valves with specific pressure requirements (135 and 140 PSI), and adherence to National Board Inspection Code standards. Vendors must submit questions by November 7, 2025, at 08:00 MT via email to the contract specialists, and must follow strict communication guidelines to remain eligible for award.

View the file

Other files

File Type Posted
P09_SOW_Annual Boiler Maint_with contracting 11.13.2025.doc DOC document
36C25926Q0011 0002.docx DOCX document
36C25926Q0011 0003.docx DOCX document
P09_SOW_Annual Boiler Maint_with contracting 10.24.doc DOC document
VHA Directive 1810.pdf PDF
Past Performance Questionnaire.docx DOCX document
P09_SOW_Annual Boiler Maint_with contracting 10.06.doc DOC document
36C25926Q0011.docx DOCX document
S02 SAM Wage Determination.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment to a Previous Combined Solicitation

Amendment to a Previous Combined Solicitation

SUBJECT*
ANNUAL BOILER Maintenance Base Plus 4 Option Years for ECHCS

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
80111
SOLICITATION NUMBER*
36C25926Q0011
RESPONSE DATE/TIME/ZONE
11-13-2025 14:00 MOUNTAIN TIME, DENVER, USA
ARCHIVE
15 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
J045
NAICS CODE*
238220
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office

NCO 19

6162 South Willow Drive, Suite 300 Greenwood Village CO 80111

POINT OF CONTACT*

Contract Specialist Natasha Holland natasha.holland@va.gov 303.712.5753

PLACE OF PERFORMANCE

ADDRESS
Department of Veteran Affairs

Eastern Colorado Healthcare System

Rocky Mountain Regional VA Medical Center

1700 N. Wheeling Street

Aurora CO

POSTAL CODE
80045
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

The purpose of this Amendment 0001 to Request for quote (RFQ) 36C25926Q0011 is to provide for a site visit, answer questions, post updated Statement of Work (SOW) and extend the due date.

The deadline for quotes is hereby extended to November 13, 2025, at 14:00 MT.

The date for the Site Visit will be November 06, 2025 at 10:00 AM MT. The site visit meeting will begin outside the Patriot Brew of the main building at 1700 N. Wheeling Street Aurora, CO 80045. If your company is planning to attend please confirm via email to natasha.holland@va.gov and thaddeus.gray@va.gov with the name and phone number before Nov 03, 2025 at 15:00 MT.

The deadline for all questions is extended due to site visit. Questions are due 08:00 AM MT Nov 07, 2025. They must be submitted by email to natasha.holland@va.gov and thaddeus.gray@va.gov. Participants must not ask questions of onsite VA employees. All questions answered outside of this requirement of this solicitation may disqualify a vendor from award. Any questions submitted after this deadline will not be answered.

Vendor Questions and Answers Amendment 0001 Q1. Could you please clarify what is meant by “Service Hours for H Stamp Welding, Testing, and Certification” in the SOW page 1? Our understanding is that this refers to the ASME certification for heating boiler manufacturers, which is typically not a requirement for service companies. Can you confirm if this interpretation is correct?

A1. This interpretation is correct. It is a requirement for working on the boiler if welding needs to be done.

Q2. Could you provide details on the relief valves to be replaced? Specifically:

How many relief valves are required?

A2. Eight (8) total (2 valves are required each boiler per VHA Boiler Safety Device Testing Manual). The valves will be tested and certified if they pass. If they do not pass, they will need to be replaced.

Q3. What are the set pressures for each valve?

A3. 135 pounds per square inch (PSI) and 140 PSI Q4. What are their capacities?

A4. At 135 PSI the capacity is 19,834 pounds (lbs.)/hr.) at approximately 85 percent of total boiler requirement. At 40 psi the Capacity is at 25,848 lbs./hr. at approximately 110 percent of total boiler requirement.

Q5. What would be more for repairs of the unit that would be covered under unscheduled repair. What do we need to specifically supply for that objective?

A5. Repairs due to unexpected failures would constitute unscheduled repairs Q6. The SOW references “Current issue of the National Board Inspection Code, Part RB”. Part RB has not been used in the NBIC for many years. The current NBIC section addressing inspections is Part 2. Please clarify.

A6. Update the RB to Part 2.

Q7. The SOW refers to an unscheduled emergency repairs section, please provide additional clarification since we are not located in the area to attend emergencies calls A7. Maintenance should be scheduled but repairs due to unexpected failures would constitute unscheduled repairs. This will be a not to exceed item to cover any unplanned maintenance that needs to be completed as seen in the unscheduled CLINS. Offerors just need to confirm that they understand that there might be times additional unplanned maintenance is involved and that those repairs will not exceed the contracted limit.

See attached document: P09_SOW_Annual Boiler Maint_with contracting 10.24.

*= Required Field
Amendment to a Previous Combined Solicitation

Page 1 of

Amendment to a Previous Combined Solicitation

File details come from the government source that posted it. Updated .