36C25925Q0681.docx

DOCX document 20 KB Posted

Attached to
6515--436 Fort Harrison VA Medical Center A/B Scanner for Opthalmology
Solicitation number
36C25925Q0681
Issued by

About this file

This document is a Combined Synopsis/Solicitation Notice for a medical equipment procurement by the Department of Veterans Affairs (VA). The VA is seeking to acquire a new A/B Scan ultrasound system for the Billings VA Ophthalmology Clinic, replacing an end-of-life device that can no longer be repaired. The specific requirements include a DICOM-compliant instrument with Forum compatibility, detachable probes, A-scan and B-scan capabilities, a footprint no larger than 15"x15", direct contact scanning, a foot pedal, and standard US outlet compatibility. The system must be manufactured in the USA, with the manufacturer responsible for equipment setup and staff training.

The solicitation is issued under NAICS code 339112 for Surgical and Medical Instrument Manufacturing, with a small business size standard of 1,000 employees. The response deadline is August 13, 2025, at 12:00 Mountain Time, with responses to be submitted via email to barron.long@va.gov. The equipment will be delivered to the Fort Harrison VA Medical Center in Montana, specifically the Billings VA Ophthalmology Clinic, with installation coordinated to minimize patient care disruption. The procurement is for a single line item: a VUPAD B-Scan/A-Scan System with Ultrasound DICOM Module.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice

SUBJECT*
436 Fort Harrison VA Medical Center A/B Scanner for Opthalmology

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
80111
SOLICITATION NUMBER*
36C25925Q0681
RESPONSE DATE/TIME/ZONE
08-13-2025 12:00 MOUNTAIN TIME, DENVER, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office

NCO 19

6162 South Willow Drive, Suite 300 Greenwood Village CO 80111

POINT OF CONTACT*

Contracting Officer Barron Long barron.long@va.gov 303-712-5741

PLACE OF PERFORMANCE

ADDRESS
Dept. of Veterans Affairs

Fort Harrison VA Medical Center

3687 Veterans Drive

Fort Harrison MT

POSTAL CODE
59636
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Sources Sought Notice – A/B SCANNER FOR OPTHALMALOGY

DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Response Instructions:

1. Do not provide more than 8 pages, including cover letter page.

1. Submit your response via email to: barron.long@va.gov

1. Submit your response NLT 12:00 (MST) on Wednesday, August 13th

1. Mark your response as “Proprietary Information” if the information is considered business sensitive.

1. VA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;

Information Requested from Industry:

1) In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.

Vendor Name:

SAM UEI #:

Name of Manufacturer:

Manufacturer Address:

Manufacturing Country of Origin Estimated Delivery Time:

SAC FSS contract number

Vendor Point of Contract (POC) Name

POC Phone Number:

POC Email Address:

STATEMENT OF WORK (SOW)

as of 07/21/2025

2. Contract Title. New A/B Scan for Billings Ophthalmology

3. Background.

The A/B Scan for measuring axial length of the eye and thickness of the retinal layers or lesions, in Billings quit working and is beyond end of life so no parts are available for repairs.

4. Scope.

Procure a new A/B Scan for Billings Ophthalmology that is on the approved list of equipment for FORUM compatibility as the interface is already in place across VA Montana.

5. Specific Tasks.

1. A/B scan instrument MUST be on the approved list of equipment for Forum compatibility – must have an ERA and be Vista Approved

2. Must have DICOM compliance capability.

3. A/B scan probes must be detachable so it can be processed by SPS in accordance with our disinfecting policy.

4. Must have A-scan and B-scan options for measuring eye length and retinal thickness or lesion thickness.

5. Due to space constraints of room equipment will be utilized in, need a single unit with interchangeable probes no larger than 15”x15” footprint.

6. Due to limited space constraints and sensitive electrical equipment, must be direct contact A-scan NOT immersion for obtaining readings.

7. Needs foot pedal to obtain readings so do not have to resituate while taking readings.

8. Must plug into standard US outlet.

9. Must be MADE IN THE USA

10. Manufacturer must set up equipment and provide instructional training to provider and technicians.

5.1 Task 1 - Enterprise Management Controls.

5.1.1 Subtask 1 – A/B Scan equipment and software must be compatible with Forum which is in place across VA Montana. Instrument will be used to take axial length, anterior chamber depth, white to white, and lesion thickness measurements, then transmit those measurements to the VA internal platform Forum where they can be assessed by the doctor. There is a specific list of approved devices that have been validated through the VistA database for compatibility with Forum. Any equipment that is not on the list is not guaranteed to work with Forum which is established and utilized throughout VA Montana, and the rigorous testing process to see if a piece of equipment is compatible take almost 12 months.

6. Security Requirements Interfaces with Forum an internal storage platform that is already in use across VA Montana.

7. Place of Performance.

Will be in the Billings VA Ophthalmology Clinic to be used by the ophthalmologist or ophthalmology technician on staff for measurements unable to be obtained by IOL master or OCT or to get an idea of retinal layers when view into eye is obstructed.

8. Delivery Schedule.

Contracted vendor will deliver to Billings VA (Benjamin Steele) and coordinate with Biomed for installation in the exam room on a date when the doctor is not seeing patients. Once the instrument has been set up Biomed with work with Ophthalmology department to schedule a training with the manufacturer to provide education on functionality and performance.

LINE ITEM:

QTY 1: VUPAD B-SCAN/A-SCAN SYSTEM WITH ULTRASOUND DICOM MODULE

*= Required Field
Combined Synopsis/Solicitation Notice

Combined Synopsis/Solicitation Notice

File details come from the government source that posted it. Updated .