This is a Sources Sought Notice issued by the Department of Veterans Affairs for the VA Western Colorado Health Care System Grand Junction VA Medical Center. The solicitation seeks surgical instruments, specifically a TPX Small Bone Power Tool System from Stryker, with 17 line items including handswitches, drills, saws, attachments, and accessories. The total quantity ranges from 4 to 8 units per line item, with specific requirements including compatibility with existing Stryker systems, ergonomic design, keyless chucks, and specialized surgical capabilities.
The Sources Sought Notice invites potential vendors to submit capability statements by 16:00 PM Mountain Time on 08/08/2025, with the goal of identifying qualified suppliers. Vendors must provide detailed business information, including NAICS code 339112, business size status, and contact details. The solicitation emphasizes the need for products that meet precise technical specifications, such as textured lightweight handles, audible connection points, touchscreen console capabilities, and surgical instrument coatings that facilitate cleaning and sterilization. This is a pre-solicitation request for information and does not guarantee a future contract.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| 575 / Equipment / Surgical Instruments-TPX Small Bone Power Tool System |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 80111 |
| SOLICITATION NUMBER* |
| 36C25925Q0669 |
| RESPONSE DATE/TIME/ZONE |
| 08-08-2025 16:00 MOUNTAIN TIME, DENVER, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office
NCO 19
6162 South Willow Drive, Suite 300 Greenwood Village CO 80111
POINT OF CONTACT*
Contracting Officer Lindsey Zwaagstra Lindsey.Zwaagstra@va.gov 303-712-5733
PLACE OF PERFORMANCE
| ADDRESS |
| VA Western Colorado Health Care System |
Grand Junction VA Medical Center
2121 N Ave.
Grand Junction CO
| POSTAL CODE |
| 81501 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov |
| URL DESCRIPTION |
| Department of Veterans Affairs |
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
STATEMENT OF NEED
VA Western Colorado Health Care System Grand Junction VA Medical Center 2121 N Ave.
Grand Junction, CO, 81501
Grand Junction VA Medical Center requires the following items, brand name or equal to salient characteristics:
| Line Item |
| Product Number |
| Product Description |
| Unit of Measure |
| Quantity |
| 0001 |
| Stryker 7400-009-000, Brand Name or Equal To |
| TPX HANDSWITCH |
| EA |
| 8 |
| 0002 |
| Stryker 4100-110-000, Brand Name or Equal To |
| AO Small Drill |
| EA |
| 4 |
| 0003 |
| Stryker 4505-134-000, Brand Name or Equal To |
| 5/32" LOCKING KEYLESS CHUCK |
| EA |
| 4 |
| 0004 |
| Stryker 4505-133-000, Brand Name or Equal To |
| 1/4" LOCKING KEYLESS CHUCK |
| EA |
| 4 |
| 0005 |
| Stryker 4100-135-000, Brand Name or Equal To |
| Hudson/Modified Trinkle Drill |
| EA |
| 4 |
| 0006 |
| Stryker 7400-031-000, Brand Name or Equal To |
| TPX OSCILLATING SAW |
| EA |
| 4 |
| 0007 |
| Stryker 7400-037-000, Brand Name or Equal To |
| TPX RECIP SAW |
| EA |
| 4 |
| 0008 |
| Stryker 7400-034-000, Brand Name or Equal To |
| TPX SAGITTAL SAW |
| EA |
| 4 |
| 0009 |
| Stryker 7400-015-000, Brand Name or Equal To |
| TPX MICRO DRILL |
| EA |
| 4 |
| 0010 |
| Stryker 5100-015-250, Brand Name or Equal To |
| MICRODRILL STRAIGHT ATTACHMENT |
| EA |
| 4 |
| 0011 |
| Stryker 5100-015-252, Brand Name or Equal To |
| Micro Drill Series Angled Attachment |
| EA |
| 4 |
| 0012 |
| Stryker 7400-099-000, Brand Name or Equal To |
| TPX UNIVERSAL DRIVER |
| EA |
| 4 |
| 0013 |
| Stryker 7400-062-000, Brand Name or Equal To |
| TPX WIRE DRIVER |
| EA |
| 4 |
| 0014 |
| Stryker 7400-004-000, Brand Name or Equal To |
| TPX CABLE |
| EA |
| 4 |
| 0015 |
| Stryker 4500-126-000, Brand Name or Equal To |
| Universal Pin/Wire Collet |
| EA |
| 4 |
| 0016 |
| Stryker 5400-052-000US, Brand Name or Equal To |
| CORE 2 - UNITED STATES |
| EA |
| 4 |
| 0017 |
| Stryker 6400-654-000, Brand Name or Equal To |
| Small Bone Solid Container |
| EA |
| 4 |
Salient Characteristics that must be met:
· Must be compatible with the Stryker system the facility already has in place for ease of use for the surgeons who are already familiar with the product line.
· Must be comprised of both drilling and sawing capabilities in order to cut and shape bone or other bone related tissue.
· Must have all the components listed on the quote to meet all surgical needs.
· Handpieces must consist of four saws, a micro drill, universal driver and wire driver.
· Must have textured light weight handle to improve grip.
· Must have distinct audible connection points to enable confident connection.
· Must provide correct ergonomics to keep the surgeon’s wrist in a neutral position.
· Must have a keyless chuck for quick and efficient changing of components during surgery.
· Must have a secondary locking mechanism to prevent loosening of chuck during use.
· The material and coating on the pin collets must be such to prevent slipping or sticking during use.
· Handpiece can be actively washed during surgery.
· Handpieces must be coated so they can be temporarily submerged during cleaning and prior to sterilization.
· Cables must be coated to offer a low friction design to reduce catching on surgical fabric and drapes while minimizing the collection of dust and debris.
· Consoles must have touch screen capabilities for ease of switching between handpieces.
· The run/safe hand switch must be made of stainless steel and click in to place to ensure activation or deactivation.
In response to this announcement, please provide the information below. If this information is not provided, then it will be assumed the entire requirement cannot be met:
NAICS Code: 339112
Company Name:
Address:
UEI (Unique Entity ID) Number:
Contact Name:
Phone No.:
Email:
Business Size Information - Select all that applies:
· Small Business
· Emerging Small Business
· Small Disadvantaged Business
· Certified under Section 8(a) of the Small Business Act
· HUBZone
· Woman Owned
· Certified Service-Disabled Veteran Owned Small
· Veteran Owned Small Business
· Large Business
| FSS/GSA Contract Holder: |
| Yes No |
FSS/GSA Contract Number:
Effective Date/ Expiration Date:
| Proposed solution is listed and available on the above FSS/GSA Contract: |
| Yes No |
Federal Acquisition Regulation (FAR) Market Rearch Questions:
Buy American Act (FAR 52.225) – What percentage of the proposed product (including leases) is a:
1. Domestic end product? _____________ (%)
2. Foreign end product? _______________ (%)
Questions for Small Businesses ONLY:
1. Limitations on Subcontracting (FAR 52.219-14) – What percentage of the work would be subcontracted to another company? ________ If > 0, what is company’s business size: __________
2. If subcontracting, what added value do you offer (FAR 52.215-23): _______________________________
3. Nonmanufacturer Rule (FAR 52.219-33):
a. Does your company manufacturer these proposed items? [ ] yes [ ] no
b. Does your company exceed 500 employees? [ ] yes [ ] no If yes, list # of employees: _________
c. Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [ ] yes [ ] no
d. Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [ ] yes [ ] no
e. Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [ ] yes [ ] no If yes, what is the manufacturer’s name? ________________
The information submitted shall contain the company’s business size status. This is a request for information and sources only, which may or may not lead to a future solicitation. This is not a request for quote (RFQ). No questions will be answered. The VA will not pay for any information received resulting from this sources sought notice. Requests for copies of a solicitation shall not be honored or acknowledged. Information should be forwarded to the Contracting Officer. If your organization can provide all services of this potential requirement and is interested in this opportunity, please respond to Lindsey Zwaagstra, Lindsey.Zwaagstra@va.gov, Contracting Officer, Department of Veterans Affairs, NCO 19, 6162 S. Willow Drive, Suite 300, Greenwood Village, Colorado 80111 and NCO19lab@va.gov with a statement describing your capabilities and completed table above. The capability statement shall include a point of contact, complete mailing address, telephone number, email address and state the company’s business size status. The deadline for this information to be received is 16:00 PM Mountain Time, 08/08/2025.
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .