23.1211-CheyenneVA_FCA-Add 01.pdf

PDF 615 KB Posted

Attached to
Z2DA--442-22-002 Remedy FCA issues in HVAC (VA-23-00078289)
Solicitation number
36C25924R0018
Issued by

About this file

This document package includes construction plans and specifications for remedy issues in the HVAC systems at the Cheyenne VA Medical Center located in Cheyenne, Wyoming. The plans show the first floor layout of Building 45 and include notes outlining the scope of work such as removing and replacing ceiling tiles and gypsum board as needed for mechanical, plumbing, and electrical work. Specifications call for field verifying fire-rated wall partitions, cleaning and repairing existing surfaces, and installing new louvers as indicated on the mechanical drawings.

The related federal contract opportunity is a solicitation issued by the Department of Veterans Affairs for a contractor to perform the remedial HVAC work described in the construction documents. The solicitation number is 36C25924R0018 and it falls under NAICS code 238220 - Plumbing, Heating, and Air-Conditioning Contractors. The location of work is the Cheyenne VA Medical Center and the estimated value is $442,220. Responses from offerors are due by the date specified in the solicitation.

View the file

Other files

File Type Posted
2360 E. Pershing Blvd VAMC. Cheyenne _ Asbestos Report 102422.pdf PDF
36C25924R0018 0002.docx DOCX document
Site Visit Attendance Sheet.pdf PDF
CheyenneVA_FCA_HVAC- Construction Drawings.pdf PDF
Specifications - FCA HVAC.pdf PDF
36C25924R0018_1.docx DOCX document
Wage Determination WY20230023 4 7 2023.pdf PDF
S22 LOS 852.219-75.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CR

C R2

C O N

TR

O

LSD1-76

PHONE

D1-75

VBA SHARED

D1-74

ELEC

D1-73

MECH ROOM

D1-72

VSO

D1-71

UPS

D1-70

VSO

D1-69

IT

D1-68

IRM STORAGE

D1-67

VSO

D1-66A

STORAGE

D1-66

VSO

D1-64

HAC

D1-62

M TOILET

D1-61

WAITING ROOM

D1-60

F TOILET

D1-50L

STORAGE

D1-50K

STORAGE

D1-50J

OPERATORY

D1-50H

OPERATORY

D1-50G

OPERATORY

D1-50F

OPERATORY

D1-50E

X-RAY

D1-50D

X-RAY

D1-50C

DARK ROOM

D1-50B

STORAGE

D1-50A

STORAGE

D1-50

CORRIDOR

D1

LA

B

D1

D

EN

TA

L C H

IE

F

D1

D E N

TA

L

S E C R E

TA

R Y

D1

D E N

TA

L

W

AI

TI

N G

R O O M

D1-43

CONFERENCE ROOM

D1

O

FF

IC

E

D1-41

STORAGE

D1-36A

MECH ROOM

D1-36

DIRECTOR

CONFERENCE ROOM

D1-35A

TOILET

D1-35

ASSOCIATE

DIRECTOR

D1-

M E C H

AN

IC

AL

D1-33

ASSOC DIRECTOR

SECRETARY

D1-32B

CHIEF OF STAFF

D1 -0 7C

CO

RR

IDO

R

D1-06C

CORRIDOR

D1 C

C O R R

ID

O R

D1-04C

CORRIDOR

D1 C

C O R R

ID

O R

D1-02C

CORRIDOR

D1 A

IT

S P

EC

IA

LI

S T

S14F1

STAIRS

D1-79

DATUM

D1-92

INTERVIEW

D1-91

INTERVIEW

D1-90

OFFICE

D1-89

OFFICE

D1-83

OFFICE

D1-88

OFFICE

D1-87

INTAKE

D1-86

ENTRY

D1-85

OFFICE

D1-76A

ELEC VAULT

D1-84

OFFICE

D1-83A

MAIL SORT

D1-82

OPEN AREA

D1-81

HEARING ROOM

D1

B R E

AK

R O O M

D1-77

ENTRY

D1-77A

STORAGE

D1-78

OIT SERVER ROOM

D1-75

D1

C O R R

ID

O R

D1 C

C O R R

ID

O R

410.72 SF

350.53 SF

18.00 SF

34.00 SF

112.93 SF

220.06 SF 4

.2

S F

561.67 SF

26.11 SF

90.42 SF

95.61 SF

27.38 SF

22.90 SF 31.94 SF

94.88 SF87.85 SF130.01 SF

139.77 SF

33.33 SF 29.58 SF

.2

S

F229.83 SF

.9

S F

.2

S F

.8

S F

.4

S F

293.41 SF

35.41 SF

159.14 SF 124.35 SF

88.79 SF

38.76 SF

189.99 SF

151.70 SF

108.91 SF246.01 SF

96.11 SF

143.99 SF

173.76 SF

128.81 SF

127.85 SF

124.00 SF

195.18 SF

376.38 SF

483.19 SF

24.50 SF

31.50 SF85.50 SF

194.52 SF 135.10 SF

436.19 SF

161.29 SF

289.65 SF

141.38 SF

76.02 SF

146.48 SF

134.01 SF

81.73 SF

81.34 SF

81.34 SF

289.83 SF

220.56 SF

50.92 SF

219.94 SF

.1

S F

.0

S F

.0

S F

.0

S F

315.50 SF

289.83 SF

585 SF

S F

641 SF

S F

UP

DN UP

RAMP

UP TO

ROOF

M45

D

A

-B

1C B

EE

1A

-C

1DPEE1

DISCONNECT

MAIN

45E

ATTIC ACCESS HATCH

HOLE IN

WALL

A3-01

AHU #21

MECHANICAL ROOM

S0F3

STAIRS

A3-S01

ROOF

739.394 SF

257.912 SF

DN

1. WITHIN THE CONSTRUCTION AREA THE CONTRACTOR SHALL FIELD VERIFY ALL

EXISTING RATED WALL PARTITIONS AS DENOTED ON THE PLAN.

2. REMOVE, CLEAN, PATCH/REPAIR EXISTING SURFACES/FINISHES AS NECESSARY FOR

THE INSTALLATION OF NEWLY SCHEDULED FINISHES. FIELD VERIFY AND MATCH

EXISTING ACT AND PAINT COLOR

FLOOR PLAN NOTES

REMOVE & REPLACE ACT CEILING TILE AS NEED TO COMPLETE MEP

SCOPE.

REF. TO MECH. PLUMB, & ELEC

REPLACE ALL BROKEN OR STAINED TILES. BUDGET 20%

REPLACEMENT.

REMOVE & REPLACE GYP. BD. CEILING AS NEED TO COMPLETE MEP

SCOPE.

REF. TO MECH. PLUMB, & ELEC

SMOKE BARRIER

1HR WALL

2HR WALL

FLOOR PLAN LEGEND

COORDINATION NOTE:

OWNER COR TO TEMPORARLY

RELOCATE STAFF DURING

CONSTRUCTION.

DEMO PORTION OF WALL TO ALLOW FOR MECH LOUVER

REF MECH

DEMO PORTION OF WALL TO ALLOW FOR MECH LOUVER

REF MECH

SEE DETAIL 3/A2.01 AT NEW LOUVERS

EXISTING EXTERIOR STUCCO WALL,

CONTRACTOR TO VERIFY

CONSTRUCTION & NOTIFY ARCHITECT

OF ANY DEVIATION OF ASSUMPTIONS.

SEALANT

PREFINISHED METAL FLASHING SET IN

EXISITING STUCCO

3/4" TREATED PLYWD.

PATCH EXISTING WALL W/ 5/8" TYPE X GYP.

BD. AS NEED FOR NEW LOUVER INSTALL

NEW LOUVER

REF. MECHANICAL

3/4" TREATED PLYWD.

NEW 600T125-43

JAMB DETAIL

PATCH EXISTING WALL W/ 5/8" TYPE X GYP.

BD. AS NEED FOR NEW LOUVER INSTALL

2" 16 GA STRAPPING

SEALANT

3/4" TREATED PLYWD.

PATCH EXISTING WALL W/ 5/8"

TYPE X GYP. BD. AS NEED FOR

NEW LOUVER INSTALL

NEW LOUVER

REF. MECHANICAL

NEW (3) 6" MTL. STUDS TO MATCH

EXISTING TYP STUD DIMENSIONS.

SET BOTTOM IN (E) TRACK TO

MATCH (E) CONNECTION

2" 16 GA STRAPPING

(2) 6" MTL. STUD HEADER (MATCH VERITCAL STUD

DIMENSIONS) WITH 600T125-43 TOP & BOTTOM. CONNECT

WIHT #8 SCREWS FROM TRACK LEGS TO STUDS @ 12"OC

MAX CONNECT TO JAMB STUDS WITH L2X2X43MIL WITH (3) #8

SCREWS TO STUDS & (3) TO HEADER TOP AND BOTTOM.

CONNECT EXISTING WALL STUDS

ABOVE OPENING TO TRACK WITH

(2) #8 TEK SCREWS.

CONNECT EXISTING WALL STUDS TO

TRACK WITH (2) #8 TEK SCREWS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

7100 East Belleview Ave.

Suite 107 Greenwood Village, CO 80111 Phone: 720.200.5955 www.specializedeng.com

SES Project : 20114.001

100% CONSTRUCTION

DOCUMENTS

12/22/22

B

IM

/2

.0

C h e y e n n e V

A A

E R e m e d y F

C A

I s s u e s i n

H V

A C

S y s te m s /A lt u s -1

-0

-S

E S

C h e y e n n e V

A

F C

A -R

.r v t

/1 /2

:0

:0

P M

A2.01

FLOOR PLAN - LEVEL 1

1/8" = 1'-0"

BUILDING 45, PLAN LEVEL 1

1 1/8" = 1'-0"

SPECIALTY CLINIC PENTHOUSE

1 1/2" = 1'-0"

LOUVER DEATIL

20114.001

BUFFALO

FCA ISSUES IN HVAC

SYSTEMS

CHEYENNE, WY

Revisions: Date:

ADDENDUM 01 12.11.2023

Sheets
A2.01 - FLOOR PLAN - LEVEL 1

File details come from the government source that posted it. Updated .