36C25921Q0064_1.docx

DOCX document 15 KB Posted

Attached to
B599--Air Balancing Sheridan VAMC Base with 4 option years
Solicitation number
36C25921Q0064
Issued by

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Opportunity Presolicitation Notice

PRODUCT SERVICE CODE

SUBJECT

CONTRACTING OFFICE'S

ZIP-CODE

SOLICITATION NUMBER

RESPONSE DATE/TIME/ZONE

ARCHIVE

DAYS AFTER THE RESPONSE DATE

RECOVERY ACT FUNDS

SET-ASIDE

NAICS CODE

CONTRACTING OFFICE

ADDRESS

POINT OF CONTACT

(POC Information Automatically Filled from User Profile Unless Entered)

DESCRIPTION

See Attachment

AGENCY'S URL

URL DESCRIPTION

AGENCY CONTACT'S EMAIL

ADDRESS

EMAIL DESCRIPTION

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

GENERAL INFORMATION

PLACE OF PERFORMANCE

* = Required Field Contract Opportunity Presolicitation Notice B599 Air Balancing Sheridan VAMC Base with 4 option years 74401 36C25921Q0064 12-09-2020 14:00

CENTRAL TIME, CHICAGO, USA

N

SDVOSBC

541380 Department of Veterans Affairs Network Contracting Office

NCO 19

1011 Honor Heights Dr Muskogee, Ok 74401 Mitchael Purdom Sheridan VAMC 1898 Fort Road Sheridan, WY 82801-8322

82801

USA

https://www.sheridan.va.gov/ https://www.sheridan.va.gov/ mitchael.purdom@va.gov Mitchael Purdom Contract Specialist Veterans Affairs Healthcare Systems Sheridan, Wyoming Statement of Work (SOW) Medical Center Air Flow Measurement and Testing

1. SCOPE OF WORK

1.1 Services are required monthly and bi-annually at the VA Medical Center in Sheridan, Wyoming to conduct air flow and balancing tests at various locations in the facility. Contractor is to provide written results required by USP 797 and per NEBB's Testing Adjusting and Balancing (TAB) procedures. Written results shall contain fan design data and test data including CFM, velocity, duct size, total static pressure across fan, external static pressure upstream of fan, and external static pressure downstream of fan. Locations are listed below:

2. MONTHLY DOCUMENTATION

2.1 Documentation is required for air exchanges and room pressure for the following areas:

Sterile Products Service Bld 71N:
1. Sterile Storage area Room 112
2. Locker Room 112A
3. Sterile Preparation Room 112B
4. Equipment Closet Room 112B

5. HAC Room 112C

6. Office Room 112D

7. Storage Room 112E

8. Common Area Room 112F

9. Medivator area Room 112G

10. Decontamination Room 108

11. Storage Room 108B

12. HAC room 108C

13. Restroom Room 107

14. Corridor Room C112

Sterile Product Distribution Bld. 7:
1. Breakout Room 003
2. Clean Storage Room 002
3. Bulk Storage Room 003B

Ambulatory Care Bld 71N

1. Exam Room 126

3. BI-ANNUAL DOCUMENTATION

3.1 Documentation is required for Supply Air flow readings in the following areas:

1. Micro Biology Room 208 (bld 71N Lab)
2. Lab Room 217 (bld 71N Lab) 2 VAV’S

3.2 Documentation is required for Pressure Differential Tests in the following areas:

1. Ambulatory Care (bld 71N) two negative air rooms Room 128 and 131
2. Medical Unit (bld 71) negative air rooms 316, 316A, 317, 318, and 318A