RES_As-Built_JCI_Fire Alarm Pt 2.pdf
PDF 14 MB Posted
- Solicitation number
- 36C25920R0112
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RES SERVICE LEVEL
ELEC 02-SV-G2-E1
NORTH WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
2"
2'-0
6'
2'4"
1'-10"
1" CONDUITS
TYPICAL
FLOOR
BB-100
3/4" CONDUIT
WEST WALL
EAST WALL
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(PANEL/CIRCUIT #TBD)
DITEK TSS4
3"
2" CONDUIT
FOR FA
CABLES
FPS
N
DOORWAY
FIRE
ALARM
TERMINAL
CABINET
7'-6" 8'-2"
RES LEVEL 1
ELEC 02-01-G2-E2
WING WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FLOOR
SOUTH WALL
NORTH WALL
N
2"
2'-0
6'
2'4"
1'-10"
1" CONDUITS
TYPICAL
BB-100
3/4" CONDUIT
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(PANEL/CIRCUIT #TBD)
DITEK TSS4
3"
2" CONDUIT
FOR FA
CABLES
FPS
FIRE
ALARM
TERMINAL
CABINET
1'-6"
7'-6" 8'-2"
WING WALL
02-SV-G2-E1
ELEC
RES SERVICE LEVEL
ELEC 02-SV-G2-E1
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
02-FPS1
02-FTC1
BB100
BELOW
TSS4
RES LEVEL 1
ELEC 02-01-G2-E2
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
02-01-G2-E2
ELEC
FACP
LOCATION
ON
CONTRACT
DRAWINGS
02-FPS2
F
T C
BB100
BELOW
TSS4
RES LEVEL 2
ELEC 02-02-G2-E2
WEST WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FLOOR
SOUTH WALL
NORTH WALL
N
2"
2'-0
6'
2'4"
1'-10"
1" CONDUITS
TYPICAL
BB-100
3/4" CONDUIT
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(PANEL/CIRCUIT #TBD)
DITEK TSS4
3"
2" CONDUIT
FOR FA
CABLES
FPS
FIRE
ALARM
TERMINAL
CABINET
4'-0
7'-6" 8'-2"
RES LEVEL 3
ELEC 02-03-G2-E2
WING WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FLOOR
SOUTH WALL
NORTH WALL
N
2"
2'-0
6'
2'4"
1'-10"
1" CONDUITS
TYPICAL
BB-100
3/4" CONDUIT
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(PANEL/CIRCUIT #TBD)
DITEK TSS4
3"
2" CONDUIT
FOR FA
CABLES
FPS
FIRE
ALARM
TERMINAL
CABINET
1'-6"
7'-6" 8'-2"
WING WALL
RES LEVEL 2
ELEC 02-02-G2-E2
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
02-02-G2-E2
ELEC
02-FPS3
F
T C
BB100
BELOW
TSS4
RES LEVEL 3
ELEC 02-03-G2-E2
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
02-03-G2-E2
ELEC
02-FPS4
F
T C
BB100
BELOW
TSS4
D E
S C
R I P
T I O
N D
A T
E
R E
S
S
E R
V I C
E
L
E V
E L
T
O
L
E V
P
A N
E
V A
T I O
N
D
R A
W I N
G S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
N
F
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
12/16/2016 2:54:38 PM
AS-BUILT
12-06-2017
RES PENTHOUSE LEVEL
ELEC 02-PH-F3-E1
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
02-PH-F3-E1
ELEC
F
C P
F
T C
F
P S
BB100
BELOW
T S
S
B B
ATS-HMI
02-LEQP2
02-LEQP1
30KVA
TRANSFORMER
45KVA
TRANSFORMER
FACP
LOCATION
ON
CONTRACT
DRAWINGS
F
C P
F
T C
F
P S
BB100
BELOW
T S
S
B B
RES PENTHOUSE LEVEL
ELEC 02-PH-F3-E1
WEST WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
NORTH WALL
FLOOR
SOUTH WALL
DOORWAY
N
LAMP TEST
TROUBLE
DVC OFF-LINE
MICROPHONE
TROUBLE
PHONE
TROUBLE
BUSY/WAIT
PAGE
INHIBITED
PRE/POST
ANNOUNCE TONE
POWER
ALL
CALL
PAGE
ACTIVE
EVAC
AREAS
ENABLE
TELEPHONE
PAGE
PAGE
ACTIVE
ALERT
AREAS
PAGE
INACTIVE
AREAS
3/4" CONDUIT
FIRE
ALARM
TERMINAL
CABINET
2'-0
2'-8
4'-6
4"
5'
1'-10
4"
4"
6'
7'-6"
8'-2"
4"
1"
1'-5
3'-2
8"
RES LEVEL 1
CORRIDOR B1-C03 / CORRIDOR 02-01-F2-04
NORTH WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FLOOR
N
STAIR
B1-ST2
DOORWAY
02-FSA
3/4" CONDUIT FOR
FIRE ALARM CABLE
1" CONDUIT
FOR FIBER
GMAP
CUSTOM GRAPHIC MAP
MANUFACTURED BY
KIRKLAND. PRELIMINARY
SIZE OF 48"W X 36"H.
1" CONDUIT
FOR FIBER
5'-5
1"
5'-9
2'-9
4'-6"
SHAFT WALL
ELEC
B1-122
DOORWAY
05-FSA2
GMAP
RES LEVEL 1
CORRIDOR B1-C03 / CORRIDOR 02-01-F2-04
NORTH WALL
FIRE ALARM PANEL ELEVATION
SCALE: 1/2" = 1'0"
N
CORRIDOR
STOR
STAIR
FEMALE TLT
D E
S C
R I P
T I O
N D
A T
E
R E
S
P
E N
T H
O U
S
V
P
N
E
V A
T I O
N
D
R A
W I N
G S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
12/16/2016 2:54:44 PM
3/8" X 1 1/4" Hex Head Bolt, 3/8" x 1" Fender Washer, 3/8" Drop-in Anchor(Below)
3/8" X 1 1/4" Hex Head Bolt, 3/8" x 1" Fender Washer, 3/8" Drop-in Anchor(Below)
3/8" X 1 1/4" Hex Head Bolt, 3/8" x 1" Fender Washer, 3/8" Drop-in Anchor(Below)
3/8" X 1 1/4" Hex Head Bolt, 3/8" x 1" Fender Washer, 3/8" Drop-in Anchor(Below)
1 5/8" Unistrut secured to floor
1 5/8" Unistrut secured to floor
Concrete Floor Concrete Floor
5/8" Drywall
3/8" x 4" Mushroom Head Toggle Bolt
3/8" x 1" Fender Washer
3/8" x 1-1/4" Hex Bolt, 3/8" x 1" Fender Washer
3/8" Drop-in Anchor
1 5/8" Unistrut secured to floor.
Set back 1" to allow door to close.
1 5/8" Unistrut secured to floor
3/8" x 1-1/4" Hex Bolt, 3/8" x 1" Fender Washer
3/8" Drop-in Anchor
3/8" x 4" Mushroom Head Toggle Bolt
3/8" x 1" Fender Washer
3/8" x 4" Mushroom Head Toggle Bolt
3/8" x 1" Fender Washer
3/8" x 4" Mushroom Head Toggle Bolt
3/8" x 1" Fender Washer
3/8" x 4" Mushroom Head Toggle Bolt
3/8" x 1" Fender Washer
3/8" x 4" Mushroom Head Toggle Bolt
3/8" x 1" Fender Washer
BB-200 Battery Box secured to wall. Will sit on top of (not secured
to) unistrut which is secured to floor.
3/8" x 1-1/4" Hex Bolt, 3/8" x 1" Fender Washer
3/8" Drop-in Anchor
3/8" x 1-1/4" Hex Bolt, 3/8" x 1" Fender Washer
3/8" Drop-in Anchor
1 5/8" Unistrut secure to floor
BB-200 Battery Box
Mounting Detail
Front View
BB-200 Battery Box
Mounting Detail
Side View
BB-200 Battery Box
Mounting Detail
Top View
BB-200 Battery Box
1"
1"
BB-200 Battery Box secured to wall. Will sit on top of (not secured
to) unistrut which is secured to floor.
NOTE:
ALL MOUNTING HARDWARE IS AN EXAMPLE OF PARTS ONLY.
EXACT MOUNTING HARDWARE USED SHALL BE DETERMINED BY
CONTRACT DOCUMENTS AND SHALL BE APPROVED FOR USE.
D E
S C
R I P
T I O
N D
A T
E
R E
S
P
E N
T H
O U
V
B
M
U
N T
I N
G
D
E T
A I L
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
12/16/2016 2:54:50 PM
D
S C
R I P
T I O
N D
A T
E
R E
S E
A R
H
D
G
F
I R
E
A
L A
R
Y S
T E
M
P
A N
N
D U
I
L
L
C
A L
C U
L A
T I O
N S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
D
G
F
I R
E
A
L A
S
T E
M
P
A N
T
T E
L
C U
L A
T I O
N S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
D
G
F
I R
E
A
L A
S
T E
M
P
A N
V
L
T A
G
O
P
C
A L
C S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
D
G
F
I R
E
A
L A
S
T E
M
P
A N
V
L
T A
G
O
P
C
A L
C L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
U I L
D I N
G
F
I R
E
A
L A
S
T E
M
D
E V
I C
E
S
C H
E D
U L
O
P
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
I L
D I N
G
F
I R
E
A
L A
S
T E
M
D
E V
I C
E
S
C H
E D
U L
O
P
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
I L
D I N
G
F
I R
E
A
L A
S
T E
M
D
E V
I C
E
S
C H
E D
U L
O
P
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
I L
D I N
G
F
I R
E
A
L A
S
T E
M
D
E V
I C
E
S
C H
E D
U L
O
P
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
I L
D I N
G
F
I R
E
A
L A
S
T E
M
N
V
I C
E
S
C H
E D
U L
O
P
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
I L
L D
I N
G
F
I R
E
A
L A
S
T E
M
N
V
I C
E
S
C H
E D
U L
E S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
S C
R I P
T I O
N D
A T
E
R E
S E
A R
D
G
F
I R
E
A
L A
S
T E
M
D
E V
I C
E
S
C H
E D
U L
T
E G
O R
I Z
E D
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
N002L05D001
N002L05D002N002L05D003
N002L05D004
N002L05D100
N002L05D005
N002L05D006
N002L05D101
N002L05D007
N002L05D008
N002L05D009
N002L05D012
N002L05D011
N002L05D014
N002L05D015
N002L05D016 N002L05D017 N002L05D018
N002L05D019 N002L05D020
N002L05D102
N002L05D021 N002L05D022
N002L05D103
N002L05D023
N002L05D024
N002L05M003
N002L05M026
N002L04D001
N002L04D002
N002L04D003
N002L04D004
N002L04D007
N002L04M001N002L04M005
N002L03D001
N002L03D002
N002L03D003
N002L03D004
N002L03D005
N002L03M001 N002L03M005
N002L02D001
N002L02D002
N002L02D003
N002L02D004
N002L02D005
N002L02D006
N002L02M001
N002L02M004
LEVEL 1 WATERFLOW N002L02M080
LEVEL 1 TAMPER N002L02M081
N002L02M012
N002L02D040
N002L02D041
N002L02D042N002L02D043
N002L02D044
N002L02D045 N002L02D046
N002L02M040
N002L02M042
N002L01D001
N002L01D002
N002L01D004
N002L01D003
N002L01D005
N002L01D006
N002L01D007
N002L01D008
N002L01D009
N002L01M003
N002L01M009
N002L01M013 PRESSURE FLOW
N002L01M014 TAMPER
RESEARCH BLDG ISOLATION
TAMPER N002L01M081
N002L01M018
N002L01M020
LOADING DOCK DRY SPRINKLER SYSTEM
PENTHOUSE
LEVEL 3
LEVEL 2
LEVEL 1
SERVICE LEVEL
INTERSTITIAL
SERVICE LEVEL
N002L02M010
N002L02M009
N002L01M034 LOW AIR
N002L01M008
F C
P
GZM
F P
S
F P
S
F P
S
F P
S
FPS1
FSA
SUPPLY
SUPPLY
SUPPLY
SUPPLY
N002L01D087
A(07)
C(01)
L(06)
K(05)
H(04)
D(03)
B(02)
A(10)
PS(13)
E(09)
G(08)
PN(12)
PE(11)
YOU ARE
HERE
DEPARTMENT OF VETERANS AFFAIRS
DENVER MEDICAL CENTER
BUILDING B (RES) - RESEARCH
AURORA, COLORADO 80011
FREESTANDING
FDC
GRAPHIC ZONE MAP NOTES
THE GRAPHIC MAP(S) SHALL BE FULL COLOR IMAGE
SCREEN PRINTED ON THE REVERSE SIDE OF A 10 MIL
POLYCARBONATE LEXAN SHEET. THE PRINTED IS
IMAGE IS LAMINATED TO A 1/8" RIGID BACKING WITH A
REMOVABLE ADHESIVE FOR FUTURE REPLACEMENT.
THE GRAPHIC MAP SHALL BE SECURED IN A BLACK
(STANDARD) ANODIZED ALUMINUM FRAME AND
MOUNTED WITH A CONCEALED SECURITY HANGING
SYSTEM TO PREVENT UNAUTHORIZED REMOVAL. THE
LOCATION OF THE FACP, MAIN GRAPHIC MAP AND
OTHER GRAPHIC MAPS WITHIN THE SAME BUILDING
SHALL BE SHOWN IN RED WITH "YOU ARE HERE"
PRINTED IN RED. DETECTION DEVICES,
NOMENCLATURE, BUILDING DETAIL SHALL BE COLOR
CODED. THE INTERIOR GRAPHIC MAP SHALL BE
MANUFACTURED BY THE H.R. KIRKLAND CO.
NOTE: THIS DRAWING MAY NOT BE PLOTTED
TO ACTUAL SIZE LISTED ON THE MAP. THE
ACTUAL SIZE OF THE MAP SHALL BE 48"
WIDE X 36" HIGH.
FIRE ALARM DEVICE LEGEND
FCP
GZM
FSA
FIRE ALARM CONTROL PANEL
GRAPHIC ZONE MAP
FIRE SYSTEM NETWORK ANNUNCIATOR
SMOKE DETECTOR
DUCT SMOKE DETECTOR
HEAT DETECTOR
MANUAL PULL STATION
WATER FLOW SWITCH
VALVE TAMPER SWITCH
FIRE DEPARTMENT CONNECTION
FPS
FIRE ALARM POWER SUPPLY
LOW//HIGH AIR SWITCH
F(03)
GRADE LEVEL DOCK
SERVICE LEVEL WATERFLOW N002L01M082
SERVICE LEVEL TAMPER N002L01M083
STAIR 1 STANDPIPE TAMPER N002L01M084
STAIR 2 STANDPIPE TAMPER N002L01M080
LEVEL 2 WATERFLOW N002L03M080
LEVEL 2 TAMPER N002L03M081
LEVEL 3 WATERFLOW N002L04M080
LEVEL 3 TAMPER N002L04M081
PENTHOUSE WATERFLOW N002L05M080
PENTHOUSE TAMPER N002L05M081
N002L02D007
N002L03D006
N002L04D005
N002L05D013
N002L01D010
N002L05D010
PS
PS
N002L01M035 HIGH AIR
4/28/17 - PLOTTED TEMP MAP
2/9/17 - ADDED PULL SYMBOL AT N002L1M020
N002L05D025
N002L01D011
N002L01M039
DRY PIPE VALVE ROOM LOW TEMPERATURE ALERT
TA
TA
N002L01M036 VALVE ROOM
LOW TEMPERATURE ALERT
12/6/17 - ADDED LOW TEMP, PIT HEAT, SMOKE ABOVE PANELS. PLOTTED FOR RECORD DRAWINGS ONLY.
D E
S C
R I P
T I O
N D
A T
E
R E
S E
A R
I L
D I N
G
G
R A
P H
Z
N
E
M
A P
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
X - REFER TO SHEET 02.FA.004
D E
S C
R I P
T I O
N D
A T
E
W I R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
SPECTR
Alert
D V A N C E
SPECTR
A
Alert
D V A N C E
SPECTR
A
Alert
D V A N C E
SPECTR
A
Alert
D V A N C E
2(+)
1(-)
D E
S C
R I P
T I O
N D
A T
E
W I R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
Wht/Blk
120 Vac
Wht/Blu
10-30 Vac/dc
Wht/Yel
Comm
Blu
N/C
Yel
Comm
Org
N/O
R I B
U C
E n c l o s e d
R e l a y
A m p
S
P D
T
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
D E
S C
R I P
T I O
N D
A T
E
W I R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
CAMPUS CAMPUS
BLDG A ALARM
BLDG B ALARM
BLDG C ALARM
BLDG D/F ALARM
BLDG E ALARM
BLDG G ALARM
BLDG H ALARM
BLDG K ALARM
BLDG L ALARM
BLDG PE ALARM
BLDG PN ALARM
BLDG PS ALARM
BLDG A TRBL
BLDG B TRBL
BLDG C TRBL
BLDG D/F TRBL
BLDG E TRBL
BLDG G TRBL
BLDG H TRBL
BLDG K TRBL
BLDG L TRBL
BLDG PE TRBL
BLDG PN TRBL
BLDG PS TRBL
BLDG A SUPV
BLDG B SUPV
BLDG C SUPV
BLDG D/F SUPV
BLDG E SUPV
BLDG G SUPV
BLDG H SUPV
BLDG K SUPV
BLDG L SUPV
BLDG PE SUPV
BLDG PN SUPV
BLDG PS SUPV
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
PUBLIC SAFETY RADIO SYSTEM
NORMAL AC
POWER
LOSS OF NORMAL
AC POWER
SIGNAL FAILURE /
BOOSTER TRBL
BATTERY CHGR
TROUBLE
LOW BATTERY
CAPACITY
SPARE
SPARE
D E
S C
R I P
T I O
N D
A T
E
W I R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
DB
DB
DB
DB
DB
DB
FIRE PUMP
POWER LOSS
FIRE PUMP
PHASE REVERSAL
DB
DB
DB
DB
DB
DB
FIRE PUMP PUMP
RUNNING
FIRE PUMP
NOT IN AUTO
DAUGHTERBOARD
TERMINALS INSIDE
PUMP CONTROLLER
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
D E
S C
R I P
T I O
N D
A T
E
W I R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
W h t B l k
V a c
W h t B l u
V a c d c
W h t Y e l
C o m m
B l u
N C
Y e l
C o m m
O r g
N O
RIBU1C
Enclosed Relay 10 Amp SPDT
D E
S C
R I P
T I O
N D
A T
E
W I R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
File details come from the government source that posted it. Updated .