CBN_As-Builts_JCI_Fire_Alarm Pt 1.pdf
PDF 16 MB Posted
- Solicitation number
- 36C25920R0112
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Johnson
Controls
D E
S C
R I P
T I O
N D
A T
E
D E
P A
R T
M E
N T
O
F
V
E T
E R
A N
S
A
F F
A I R
S
R E
P L
A C
E M
E N
T
M
E D
I C
A L
C
E N
T E
R
F
A C
I L
I T
Y
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
A U
R O
R A
C
O L
O R
A D
O
C L
I N
I
B
U I L
D I N
G
N
O R
H
I R
E
A
L A
R M
S
Y S
T E
M
C
O V
E
E T
AS-BUILT
01-04-2018
INDEX OF DRAWINGS
SHEET NAME & INCLUSIONSSHEET #
FIRE ALARM SYMBOL LEGEND REV JAN 4, 2018
QTY. SYMBOL DESCRIPTION PART NUMBER BACKBOX MOUNTING
1 FIRE ALARM CONTROL PANEL IFC2-3030 SBB-D4R(SURFACE);ADD TR-D4 FOR SEMI-FLUSH WALL - TOP @ 72" AFF
1 GRAPHIC ZONE MAP KIRKLAND CUSTOM INTERIOR
GRAPHIC MAP WALL - CUSTOM
4 FIRE ALARM POWER SUPPLY EQBB-D4R(SURFACE);ADD TR-DR FOR SEMI-FLUSH WALL - TOP @ 72" AFF 1 FIRE SYSTEM NETWORK ANNUNCIATOR JNCA-2 SBB-A4R(SURFACE);ADD TR-A4 FOR SEMI-FLUSH WALL - TOP @ 64" AFF
FIRE SYSTEM NETWORK ANNUNCIATOR
(WEATHERPROOF) JNCA-2
SBB-A4R(SURFACE);ADD TR-A4 FOR SEMI-FLUSH
MOUNTED INSIDE NEMA 4X GLASS DOOR ENCLOSURE
WITH 120VAC ENCLOSURE HEATER
WALL - TOP @ 64" AFF
0 FIRE ALARM LOCAL ANNUNCIATOR LCD2-80 JABF-1B FOR FLUSH MOUNT
JABS-1TB FOR SURFACE MOUNT
WALL- TOP @64"AFF
WALL- TOP @64"AFF
4 FIRE TERMINAL CABINET IF2 SUPPLIED WITH DEVICE WALL - TOP @ 72" AFF
3 DOORHOLDER POWER SUPPLY AL1024ULXPD4R SUPPLIED WITH DEVICE WALL - TOP @ 72" AFF 0 REMOTE MICROPHONE RM-1 SBB-C4R(SURFACE);ADD TR-C4 FOR SEMI-FLUSH WALL -TOP @ 72" AFF 1 FIRE ALARM / PUBLIC ADDRESS INTERFACE XP6-R (QTY 3) BB-25 CABINET W/DOOR WALL -TOP @ 72" AFF
0 IFI WORKSTATION IFI FIELD VERIFY
7 FIRE/SMOKE DAMPER BY OTHERS
0 POST INDICATING VALVE BY OTHERS
15 REMOTE TEST SWITCH RTS151KEY 2-1/8" DEEP 4S BOX W/ 1G P-RING FIELD VERIFY
36 SMOKE DETECTOR 2951J 2-1/8" DEEP 4S BOX W/ 1G P-RING CEILING
1 SMOKE DETECTOR W/ ISOLATOR BASE 2951J W/ B224BI 2-1/8" DEEP 4S BOX W/ 1G P-RING CEILING
14 DUCT SMOKE DETECTOR DNR BY OTHERS
2 ADDRESSABLE HEAT DETECTOR ORDINARY
TEMPERATURE - 135 DEGREES F. 5951J 2-1/8" DEEP 4S BOX W/ 1G P-RING CEILING
12 ADDRESSABLE HEAT DETECTOR INTERMEDIATE
TEMPERATURE - 190 DEGREES F. 5951HJ 2-1/8" DEEP 4S BOX W/ 1G P-RING CEILING
0 NON ADDRESSABLE HEAT DETECTOR
INTERMEDIATE TEMPERATURE - 190 DEGREES F.
12-X27121-020-190
4" OCTAGONAL OUTLET BOX WITH OUTLET BOX COVER
AND (2) 1/2-14NPT RETAINER NUTS CEILING
12 ISOLATOR MODULE M500XJ 2-1/8" DEEP 4S BOX FIELD VERIFY
3 ADDRESSABLE CONTROL MODULE M300CJ 2-1/8" DEEP 4S BOX FIELD VERIFY
11 ADDRESSABLE MONITOR MODULE M300MJ 2-1/8" DEEP 4S BOX FIELD VERIFY
6 ADDRESSABLE DUAL MONITOR MODULE M300DJ 2 1/8" DEEP 4S BOX FIELD VERIFY
1 ADDRESSABLE DUAL RELAY/MONITOR MODULE M300DRMJ 2 1/8" DEEP 4S BOX FIELD VERIFY
9 ADDRESSABLE MANUAL PULL STATION JBG-12LX 2-1/8" DEEP 4S BOX W/ 1G P-RING WALL - CENTER OF 4S BOX @ 46" AFF 0 NON ADDRESSABLE MANUAL PULL STATION JBG-12L 2-1/8" DEEP 4S BOX W/ 1G P-RING WALL - CENTER OF 4S BOX @ 46" AFF
21 CONTROL RELAY (MULTI-VOLTAGE) RIBU1C-RD FITS INTO STANDARD 1/2" KNOCKOUT OF 4S BOX FIELD VERIFY
61 ADRESSABLE RELAY MODULE M300RJ 2 1/8" DEEP 4S BOX FIELD VERIFY
0 LOW AIR SWITCH BY OTHERS
7 MAGNETIC DOOR HOLDER BY OTHERS - LCN SEM 7830 COORDINATE WITH DOOR HARDWARE SUPPLIER FIELD COORDINATE
22 REMOTE ALARM INDICATOR LAMP RA100Z 2-1/8" DEEP 4S BOX W/ 1G P-RING FIELD VERIFY
5 WATER FLOW SWITCH BY OTHERS
8 VALVE TAMPER SWITCH BY OTHERS
0 VERTICAL RISER UP BY OTHERS
0 VERTICAL RISER DOWN
0 CEILING MOUNT STROBE SCW 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING CEILING
2 CEILING MOUNT SPEAKER/STROBE SPSCWV 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING CEILING 0 CEILING MOUNT SPEAKER/STROBE - HIGH CD SPSCWVH 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING CEILING
0 CEILING MOUNT SPEAKER SPCW 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING CEILING
1 EXTERIOR HORN/STROBE P2RK SUPPLIED WITH DEVICE WALL - 10' AFF ABOVE FDC
136 WALL MOUNTSPEAKER/STROBE SPSRV 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING WALL - CENTER OF 4S BOX @ 86" AFF
(SEE NOTES 1 AND 2)
0 WALL MOUNTSPEAKER/STROBE - HIGH CD SPSRH 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING WALL - CENTER OF 4S BOX @ 86" AFF
(SEE NOTES 1 AND 2)
1 WALL MOUNT SPEAKER/STROBE
WEATHERPROOF SPSRK SUPPLIED WITH DEVICE
WALL - CENTER OF 4S BOX @ 86" AFF
(SEE NOTE 2)
0 WALL MOUNTSPEAKER/STROBE - HIGH CD
WEATHERPROOF SPSRHK SUPPLIED WITH DEVICE WALL - CENTER OF 4S BOX @ 86" AFF
(SEE NOTE 2)
74 WALL MOUNT SPEAKER SPR 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING WALL - CENTER OF 4S BOX @ 86" AFF
(SEE NOTES 1 AND 2)
38 WALL MOUNT STROBE SR 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING WALL - CENTER OF 4S BOX @ 86" AFF
(SEE NOTE 1 AND 2)
0 WALL MOUNT STROBE - HIGH CD SRH 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING WALL - CENTER OF 4S BOX @ 86" AFF
(SEE NOTE 1 AND 2)
0 SIGN TO LIGHT UP "FIRE ALARM" IN LIEU OF
STROBE DEVICE IN ANIMAL HOLDING AREAS LEMD-M SUPPLIED WITH DEVICE FIELD VERIFY
0 CEILLING MOUNT SPEAKER - PSYCHIATRIC AREAS
FLUSH MOUNT - WHITE SPCW 2-1/8" DEEP 4S BOX W/ 1-1/2" EXTENSION RING CEILING
KEYED MANUAL PULL STATION - PSYCHIATRIC
AREAS (NON ADDRESSABLE) 1534-1 2-1/2" DEEP SINGLE GANG BOX FOR FLUSH MOUNT WALL - FLUSH MOUNT- CENTER OF
SINGLE GANG BOX @ 46" AFF
0 SURGE SUPRESSOR DTK-2LVLPF 6" X 6" X 4" BOX MINIMUM. SCREWS TO BACK OF BOX. FIELD VERIFY
NOTES:
1. PER KT RFI 3529 - MOUNTING HEIGHTS OF DEVICES IN THE INTERSTITIAL LEVELS WILL BE AS FOLLOWS:
THE CENTER OF THE 4S BOX WILL BE LOCATED 4" BELOW A LINE DERIVED FROM THE HORIZONTAL PLANE OF THE BOTTOM OF THE CONCRETE "T"
BEAMS ON THE INTERSTIAL LEVELS. (SEE DRAWING)
2. FOR NON-INTERSTITIAL CEILING HEIGHTS LESS THAN 90-1/2" - WALL - CENTER OF 4S BOX @ 4" BELOW CEILING MAX SO ENTIRE LENS IS WITHIN 6" OF CEILING.
GRAPHIC ZONE MAP NOTES
THE GRAPHIC MAP(S) SHALL BE FULL COLOR IMAGE
SCREEN PRINTED ON THE REVERSE SIDE OF A 10 MIL
POLYCARBONATE LEXAN SHEET. THE PRINTED IS
IMAGE IS LAMINATED TO A 1/8" RIGID BACKING WITH A
REMOVABLE ADHESIVE FOR FUTURE REPLACEMENT.
THE GRAPHIC MAP SHALL BE SECURED IN A BLACK
(STANDARD) ANODIZED ALUMINUM FRAME AND
MOUNTED WITH A CONCEALED SECURITY HANGING
SYSTEM TO PREVENT UNAUTHORIZED REMOVAL. THE
LOCATION OF THE FACP, MAIN GRAPHIC MAP AND
OTHER GRAPHIC MAPS WITHIN THE SAME BUILDING
SHALL BE SHOWN IN RED WITH "YOU ARE HERE"
PRINTED IN RED. DETECTION DEVICES,
NOMENCLATURE, BUILDING DETAIL SHALL BE COLOR
CODED. THE INTERIOR GRAPHIC MAP SHALL BE
MANUFACTURED BY THE H.R. KIRKLAND CO.
D E
S C
R I P
T I O
N D
A T
E
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
A U
R O
R A
C
O L
O R
A D
O
C B
N
F
I R
E
A
L A
D
A
W I N
G
I N
D E
X
A
S
T E
M
L
E G
E N
D S
FROM SHEET 00.AS.002
E
S C
R I P
T I O
N D
A T
E
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
A U
R O
R A
C
O L
O R
A D
O
C B
N
F
I R
E
A
L A
S
T E
M
G
E N
E R
A L
A
S T
A L
L A
T I O
N
N
O T
E S
PRIMARY RECALL
ALTERNATE RECALL
FIREMAN'S HAT LIGHT
SS
ELEVATOR RECALL RELAY MODULES:
OUT TO CONCOURSE
ELEV MACH RM HEAT DETECTOR RTS LAMP
ELEV MACH RM HEAT DETECTOR RTS STATUS
ELEV MACH RM HEAT DETECTOR REMOTE INDICATOR LIGHT
NOT USED
1" RISER CONDUIT
UP TO 1ST FLOOR V01.4.4
A08.1.6 V08.1.7
LF1
V01.4.4 P
A08.1.6 V08.1.7 L1
L1
L1
A08.1.6 V08.1.7 L1
C L1
P
P
NOTE: CBN ISOLATION TAMPER IS LOCATED ON CONCOURSE SERVICE LEVEL - SEE
SHEET 01.FA.500C
SEE SHEET 01.FA.500-C FOR
FIRE ALARM DEVICES IN THIS
AREA
A08.1.6 V08.1.7
L1
B
A
B
A
A
B
A
B
L1
ELEVATOR
MACH RM
ELEVATOR
STAIR
CORRIDOR
MECH
D E
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
E R
V I C
E
L
E V
R
E
A
L A
O
P
A
N
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
SP
SP
SP
SP
SP
SS
SS SS
SS
SS SS
SS
SS
SS
SS
SS
SS
SP
SP
SS
SS
SS
SS
SS
SS
SS
SS
SP
SP
SP
SS
SP
SP
SS
SS
A08.1.1 A08.1.2 V08.1.1 V08.1.2
A08.1.3 V08.1.3
V08.1.6 P
A08.1.1 V08.1.1 P
A08.1.1 V08.1.1
A08.1.5 (2)L1
A08.1.6 V01.4.4 V08.1.5 V08.1.7
LF1
L1
D(CBN)
DHP
P
A08.1.1 V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1 A08.1.1
V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1
A08.1.1 V08.1.1
V08.1.1
V08.1.1
(2)A08.1.1
A08.1.2 V08.1.2
(2)A08.1.2 (2)V08.1.2 A08.1.2
V08.1.2
A08.1.2 V08.1.2
A08.1.2 V08.1.2
A08.1.2 V08.1.2
A08.1.2 V08.1.2
A08.1.2 V08.1.2
A08.1.2 V08.1.2
A08.1.2 V08.1.2
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3
V08.1.4
A08.1.3 V08.1.4
A08.1.3 V08.1.4
A08.1.3 V08.1.4
A08.1.3 V08.1.4
A08.1.3 V08.1.4
A08.1.3 V08.1.4
V08.1.4
A08.1.5
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5 V08.1.4
A08.1.5
A08.1.5 V08.1.5
A08.1.5 V08.1.5
A08.1.5 V08.1.5
A08.1.5 V08.1.5
A08.1.5 V08.1.5
A08.1.5 V08.1.5
A08.1.5 V08.1.5
1-1/4" RISER CONDUIT UP
TO 2ND FLOOR
1" RISER CONDUIT DOWN TO SVC LEVEL
D(CBN)
1-1/4" RISER CONDUIT UP TO
PENTHOUSE (CBN CIRCUITS)
08-AHU-3
RETURN
STAIR 1 STANDPIPE
LEVEL 1
FLOW AND TAMPER
STAIR 2
STANDPIPE
A08.1.2 V08.1.2
P
L1
L1
C
L1
L1
L1
C (2)L1
L1
DHP
(2)L1
DHP
(2)L1
DHP
P
P
C
C
C
L1
DHP
(2)L1 L1
L1
(2)L1
L1
C
(2)L1 C
(2)L1 T
T
L1
C
L1
L1 DHP
F
F
P
IN FROM
CONCOURSE
V01.4.1
D(CON)
LF6(CON)
1-1/4" RISER CONDUIT UP TO 2ND
FLOOR (CON CIRCUITS)
1" CONDUIT
1" CONDUIT
1" CONDUIT
1" CONDUIT
A08.1.3 V08.1.4
FIBER UP TO FCP ON PENTHOUSE LEVEL
FIBER FROM PSN-TR-0B
FIBER FROM FCP ON PENTHOUSE LEVEL
FIBER TO CON TR-0B
J
J
J
J
J
J
JJ J
J
(2)L1 T
A08.1.1 (2)V08.1.1
A08.1.3 V08.1.4
A08.1.5 V08.1.5
A08.1.1 V08.1.1
V01.4.4
LF1
D
V08.1.5
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
J
(CONCOURSE SYNC CIRCUIT)
(CONCOURSE DAL CIRCUIT)
(CONCOURSE SLC LOOP 6 FEED)
FSA NETWORK
ADDRESS 108
L1
SEE SHEET 01.FA.501-C FOR
FIRE ALARM DEVICES IN THIS
AREA
08-AHU-2
RETURN
A08.1.3 V08.1.3
V08.1.5-3 A08.1.5-11
V08.1.6
V08.1.6(U)
EXTERIOR HORN/STROBE TO BE
MOUNTED ON POLE NEAR WHERE
FDC PENETRATES STAIR WALL.
ELEC
DATA / TELECOMM
ELEC
DATA / TELECOMM
DEMARC ROOM
CHUTE
STAIR
STAIR
ELEV
EXAM/TREATMENT
EXAM/TREATMENT 1
EXAM/TREATMENT
TELEHEALTH 1
PLATFORM
WAIT
GYM
MULTIFUNCT
TREAT/WORK
INST CAL/STOR
AUDIOLOGIST 1
AUDIOLOGIST 4
AUDIOLOGIST 5
AUDIO TECH 1AUDIO TECH 2AUDIO TECH 3
AUDIOMETRIC
EXAM 1
AUDIOMETRIC
EXAM 2
AUDIOMETRIC
EXAM 3
AUDIOMETRIC
EXAM 4
SPEECH 1
SPEECH 2
SPEECH
ANALYSIS
GROUP RM
SPEECH THERAPY
GROUP 1
PAT TLT 1
W.C. REPAIR
AUDIOLOGIST 6
CHIEF OFFICE
OFFICE 1
OFFICE 2
OFFICE 3
OFFICE 4
OFFICE 5
OFFICE 6
OFFICE 7
OFFICE 8
OFFICESECR/WAIT
CLERICAL 1
CLERICAL 2
STAFF LOUNGE
STAFF TLT
RESIDENT OFFICE
RECEPT
EQUIP STOR
WAIT
OFFICE
PAT TLT 1
BRACE REPAIR
LAB
PUR OFFICE
OFFICE
OTBC GYM
EDUCATION/TRAIN
TREAT 1
ELECTROMYOGRAPHY
SOILED UTIL
STAFF TLT 1
PUBLIC TLT 1
PUBLIC TLT 2
OTBC TREAT
STAFF TLT 2
STAFF TLT 4
STAFF TLT 3
OTBC
ORTHO/SPLINTING
WAIT
PAT TLT 2
OT/PT DME 2
STAFF OFFICE 1
AUDIOLOGIST 8
STAFF OFFICE 3
CAT WORK
SPEECH THERAPY
IND
VESTIBULOGRAPHY
SINUSODIAL TEST
PUBLIC TLT 3
RECEPT
AUDIOLOGIST 2
AUDIOLOGIST 3
OFFICE 6
OFFICE 5
TREAT 2
PAT RM
HEARING AID FAB
AUDIOLOGIST 7
INTERN OFFICE
HAC
SECT AND WAIT 1
SOC WORKER 3
SOC WORKER 2
SOC WORKER 1
CONSULT
CHIEF OFFICE
SOC WORKER 4
LINEN ALCOVE
COMM CTR
PROV CONSULT
ELEV LOBBY
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
SHARED OFFICE
O2 STOR
O2 COORD 4
O2 COORD 5
CONSULT
WAIT
CORRIDOR
CLEAN SUPPLY
WORK AREA
CORRIDOR
CORRIDOR
ADL TLT
FITNESS ROOM
RECEPTRECEPT
WAIT
CORRIDOR
CORRIDOR
HAC
(2)L1
(2)DHP
P
L1 P
A08.1.2 V08.1.2
1" CONDUIT
A08.1.2 A08.1.6 V08.1.1 V08.1.4 V08.1.7
D(CBN)
P
1" CONDUIT
A08.1.1 A08.1.5 V01.4.4 V08.1.2 V08.1.5
LF1
L1
DHP
A08.1.2 V08.1.2
A08.1.5 A08.1.6 V01.4.4 V08.1.4 V08.1.5
V08.1.7
LF1
L1
D(CBN)
DHP
P
J
A08.1.5 A08.1.6 V01.4.4 V08.1.4 V08.1.5
V08.1.7
LF1
L1
D(CBN)
DHP
P
J
A08.1.5 A08.1.6 V01.4.4 V08.1.4 V08.1.5
V08.1.7
LF1
L1
D(CBN)
DHP
P
V01.4.4 V08.1.5
LF1
L1
DHP
P
A08.1.5 A08.1.6 V08.1.4 V08.1.7
D(CBN)
J J
A08.1.5 A08.1.6 V01.4.4 V08.1.5 V08.1.7
LF1
L1
D(CBN)
DHP
P
J J J
V01.4.1
D(CON)
LF6(CON)
A08.1.6 V01.4.1 V01.4.4 V08.1.5 V08.1.7
LF1
L1
D(CON)
LF6(CON)
DHP
P
A08.1.6 V01.4.4 V08.1.7
LF1
P
J
(2)A08.1.5 (2)V08.1.5
J
V08.1.4
(2)A08.1.3
(2)L1
DHP
(2)L1
L1
A08.1.6 V01.4.1 V01.4.4 V08.1.7
LF1
L1
D(CON)
LF6(CON)
DHP
P
(2)L1 V08.1.4
(2)L1
(2)L1
(2)L1
A08.1.3 V08.1.3
A08.1.3 V08.1.3
A08.1.3 V08.1.4
CHUTE
TAMPER
C A08.1.5
J
(2)L1
D(CBN)
V01.4.1
D(CON)
LF6(CON)
A08.1.2 V08.1.2
A08.1.2 V08.1.2
A08.1.2 V08.1.2
J
J J
J
JJ
L1
(2)L1 N008L01D012
L1
JJ
(2)V08.1.1 (2)V08.1.1
(2)V08.1.1
JJ
(2)V08.1.1 (2)V08.1.1
(2)V08.1.1
J J
(2)V08.1.1 (2)V08.1.1
(2)V08.1.1
J J
V08.1.1
(2)V08.1.1
(2)V08.1.1
TO PUBLIC SAFETY RADIO DAS UPS
N008L01M008 - LOSS OF NORMAL AC POWER
N008L01M009 - BATTERY CHARGER FAILURE
N008L01M010 - LOW BATTERY CAPACITY
43 RELAY TO CONTROL 24VDC POWER TO REMOTE INDICATOR LIGHTS.
D E
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
E V
R
E
A
L A
O
A
N
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
AS-BUILT
01-04-2018
Exterior horn strobe mounted on pole
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SP
SP
SS
SS
SP
SP
SP
SS SS
A08.2.1 V08.2.1
L2
A08.2.1 V08.2.1
L2
(2) A08.2.1
(2) V08.2.1
L2 A08.2.1 V08.2.1
A08.2.1 V08.2.1
A08.2.1 V08.2.1
A08.2.1 V08.2.1
A08.2.1 V08.2.1
A08.2.1 V08.2.1
A08.2.1
A08.2.1 A08.2.1
A08.2.1
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2 A08.2.2
V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.5 V08.2.3
A08.2.6 V08.2.4
A08.2.6 V08.2.4
A08.2.6 V08.2.4
A08.2.6 V08.2.4
A08.2.6 V08.2.4
A08.2.6 V08.2.4
A08.2.6 V08.2.4
A08.2.2 V08.2.2
A08.2.2 V08.2.2
A08.2.5 V08.2.3
(2) A08.2.1
(2) V08.2.1
A08.2.2 V08.2.2
P
L2
L2
C
(2) L2
L2
L2
L2
L2
L2 (2)L2
DHP
P
P
L2
DHP
DHP
C
C
L2
DHP
L2
DHP
(2) L2
L2
DHP
(2) L2
P
(2) L2
L2
DHP
A08.2.6 V08.2.4
(2)L2 T
A08.2.6 V08.2.4
L2
DHP
(2) L2
(2) L2
C
(2)L2
(2)L2 T
OUT TO
CONCOURSE
A08.2.1 V08.2.1
1" CONDUIT
1" CONDUIT
08-AHU-3
RETURN
A08.2.1 A08.2.2 V08.2.1 V08.2.2
1" CONDUIT
A08.2.1 A08.2.5 A08.2.6 V08.2.1 V08.2.3 V08.2.4
DHP
L2
A08.2.1 A08.2.6 V08.2.1 V08.2.4
DHP
L2
V01.4.4
LF1
D
A08.2.6 V08.2.4
L2
DHP
1-1/4" CONDUIT RISER FROM 1ST
FLOOR TO PENTHOUSE FOR
DAL CIRCUIT (FOR CBN)
1-1/4" RISER CONDUIT DOWN TO 1ST
LEVEL/ UP TO 3RD LEVEL FOR
CONCOURSE CIRCUITS
08-AHU-2
RETURN
JJ J
J
J
J JJJ
J
JJ
FIBER UP TO FCP ON PENTHOUSE LEVEL
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
J
A01.7.1(CON)
A01.7.2(CON)
A01.7.3(CON)
V01.7.1(CON)
V01.7.2(CON)
V01.7.3(CON)
L6(CON)
DHP(CON)
A01.7.1(CON)
A01.7.2(CON)
A01.7.3(CON)
V01.7.1(CON)
V01.7.2(CON)
V01.7.3(CON)
L6(CON)
DHP(CON)
1" CONDUIT
A01.7.1(CON)
A01.7.2(CON)
A01.7.3(CON)
V01.7.1(CON)
V01.7.2(CON)
V01.7.3(CON)
L6(CON)
DHP(CON)
L2 P
SEE SHEET 01.FA.502-C FOR
FIRE ALARM DEVICES IN THIS
AREA
A08.2.5 V08.2.3
L2
A08.2.5 V08.2.3
SS
A08.2.5 V08.2.3
A08.2.6 V08.2.4
L2
DHP
IM MM
V01.4.4
LF1
LF2
D
(2)V01.4.1
(2)D(CON)
(2)LF6(CON)
DATA / TELECOMM
ELEC
DATA / TELECOMM
ELEC
CHUTE
ELEV
STAIR
STAIR
CHIEF OFFICE 1
ADMIN ASST 1
ASST CHIEF 1
CHIEF OFFICE
PHOTO
EDIT/PRINT
CAMERA COPY
PHOTO STUDIO
EQUIP STOR
AMB CARE 1
AMB CARE 3
AMB CARE 4AMB CARE 6
AMB CARE 7
AMB CARE 8
SPEC CARE 1
SPEC CARE 2
SPEC CARE 3
SPEC CARE 4
SPEC CARE 5
ADMIN 1ADMIN 2
ADMIN 4
ADMIN
WORKSTATION 3
SECR/WAIT
CORR CLERK 1
SECR/WAIT
PROG SPEC 1
STOR
HEALTH
MANAG 1
CODING 1 CODING 2
CODING 3 CODING 4
CODING 5
CODING 6CODING 7
CODING 8 LEAD 1FILE SUPER 1
FILE 1
FILE 1 FILE 10
FILE 2 FILE 3
FILE 4
FILE 5
FILE 6
FILE 7 FILE 8 FILE 9
MED REC SPEC 1
RECEPT
ROI 1
ROI 2
ROI 3
SUP PRIV 1
SUP 1
SUP 2
SUP 3
SUPP WORK
TRANS
BLEACHER
CHIEF FEE 1
LEAD 1
EQUIP STOR
SCHEDULER
AMB CARE 2
COMP
CLASSROOM
CHIEF OFFICE CHIEF OFFICESEC/CLER 1
REPAIR SHOP
STOR
ADP STOR
OFFICE
OFFICE
SUPERVISOR
WORKSTATION
ISO OFFICE 2
SC WORKSTATION
SC WORKSTATION
SC WORKSTATION
SC WORKSTATION
TECH 1
TECH 10TECH 11
TECH 12
TECH 2
TECH 3
TECH 4
TECH 5
TECH 6
TECH 7
TECH 8
TECH 9
CHIEF OFFICE
PROJ WORK
PROG
WORKSTATION 1
PROG
WORKSTATION 2
PROG
WORKSTATION 4
PROG
WORKSTATION 5
ISO OFFICE 1
SERVICE WINDOW 1
SERVICE WINDOW 2
SERVICE
WINDOW 3
STOR
VAULT 1
MANAGER OFFICE
LOAN OFFICE
CONF 1
STAFF TLT 1
CONF 2
COPY/FAX 2
CONF 3
STAFF TLT 2
PROG
WORKSTATION 3
SEC OFFICE
STOR
CACS
WORKSTATION 1
CACS
WORKSTATION 2
CACS
WORKSTATION 3
CACS
WORKSTATION 4
CACS
WORKSTATION 5
NURSE COORD 2
NURSE COORD 5
NURSE COORD 4
NURSE COORD 3
SCHEDULE
APN
WORKSTATION
AP NURSE 2
AP NURSE 4
STAFF TLT 5
STAFF LOUNGE
CHIEF OFFICE
SEC OFFICE
STAFF TLT 3
HAC 1
STAFF TLT 4
HAC 2
SUPPLY
SUPPLY
NURSE COORD 6
AP NURSE 3
ASST CHIEF 1
ASST CHIEF 2
STOR
CHIEF OFFICE
ASST CHIEF
OFFICE 2
ASST CHIEF
OFFICE 1
COPY/FAX 1
WAIT
SHARED OFFICE 3
SHARED OFFICE 4
SHARED OFFICE 1
SHARED OFFICE 2
CHIEF OFFICE
CHIEF OFFICE
SHARED OFFICE 3
SHARED OFFICE 4
SHARED OFFICE 1
SHARED OFFICE 2
WORKSTATION 1
CONSULT
FILE STOR/REC
CONTING CONTING
CONTING CONTING
CONTING
WORKSTATION 3
WORKSTATION 1
WORKSTATION 4 WORKSTATION 2
RECEPTIONWORKSTATION 5
WAIT
HELP DESK
ELEV LOBBY
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
SC WORKSTATION
A08.2.5 V08.2.3
J
A08.2.5 V08.2.3
J(2)L2
(2)L2 T
T
J L2
DHP
(2)L2
N008L02D007
J
DHP
L2
J (2)L2
L2
L2
(2)L2
(2)L2 P
P
43 RELAY TO CONTROL 24VDC POWER TO REMOTE INDICATOR LIGHTS.
D E
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
E V
R
E
A
L A
O
A
N
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
SS
SS
SS
SS
SS
SS
SS SS
SS
SS
SS
SS
SSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SP
SP
SS
SS
A08.3.1 V08.3.1
A08.3.2 V08.3.2
(2)A08.3.2 (2)V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
A08.3.2 V08.3.2
V08.3.2
A08.3.1 V08.3.1
A08.3.1 V08.3.1
A08.3.1 V08.3.1
(2)V08.3.1
A08.3.1 V08.3.1
A08.3.1 V08.3.1
A08.3.1 V08.3.1
A08.3.1 V08.3.1
A08.3.1 V08.3.1
A08.3.1
A08.3.1
A08.3.1 A08.3.1
A08.3.3 V08.3.3
A08.3.3 V08.3.3
A08.3.3 V08.3.3
A08.3.3 V08.3.3
A08.3.3 V08.3.3
A08.3.3 V08.3.3
A08.3.3 V08.3.3
V08.3.3
V08.3.3
A08.3.4 A08.3.5 V01.4.4 V08.3.4 V08.3.5 V08.3.6
V08.3.7 LF1
(2)LF3 LF2
L3 D DHP
A08.3.4 V08.3.4
A08.3.4 V08.3.4
A08.3.4 V08.3.4
A08.3.4 V08.3.4
A08.3.4 V08.3.4
A08.3.4 V08.3.4
A08.3.4 V08.3.4
A08.3.4
V08.3.5
D V01.4.4 V08.3.5 V08.3.7
LF3
LF2
LF1
A08.3.4 V08.3.5
A08.3.4 V08.3.5
A08.3.4 V08.3.5
A08.3.4 V08.3.5
A08.3.4 V08.3.5
A08.3.4 V08.3.5
(2) A08.3.5
(2) V08.3.6
A08.3.5 V08.3.6
A08.3.5 V08.3.6
A08.3.5 V08.3.6
A08.3.5 V08.3.6
A08.3.5 V08.3.6
A08.3.5 V08.3.6
A08.3.5 V08.3.6
A08.3.5 V08.3.6
A08.3.5 V08.3.6
A08.3.5
A08.3.5 V08.3.7
A08.3.5 V08.3.7
A08.3.5 V08.3.7
A08.3.5 V08.3.7
A08.3.5 V08.3.7
V08.3.7
D V01.4.4 V08.3.7
LF3
LF2
LF1
V01.4.4
LF3
LF2
LF1
D
V01.4.4
LF2
LF1
D
2" RISER CONDUIT UP
TO PENTHOUSE
1-1/4" CONDUIT UP TO PENTHOUSE
(CBN CIRCUITS)
D(CBN)
1-1/4" RISER CONDUIT
DOWN TO 2ND FLOOR
(2)L3
C
C
P(2)L3
(2)L3
C
(2)L3
C
LF3
L3
DHP
(2)L3
(2)L3
L3
(2)L3
L3
DHP
L3
DHP
L3
DHP
(2)L3
DHP
(2)L3
DHP
P
P L3L3
L3
1-1/4" CONDUIT
DOWN TO 2ND FLOOR
(CON CIRCUITS)
OUT TO
CONCOURSE
1" CONDUIT
1" CONDUIT
2" CONDUIT
1-1/4" CONDUIT DOWN TO 2ND FLOOR (CBN CIRCUITS)
(2)1" CONDUITS
D
DHP
A08.3.4 A08.3.5 V01.4.4 V08.3.4 V08.3.5 V08.3.6 V08.3.7
LF1
LF2
(2)LF3
(2) 1"
CONDUITS
FIBER UP TO FCP ON PENTHOUSE LEVEL
FIBER UP TO FCP ON PENTHOUSE LEVEL
J
JJ
J J
J
J
J
A08.3.5 V08.3.6
1" CONDUIT
EOL A08.3.2
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
J
#1
#2
(2)1" CONDUITS
CONDUIT#1
A01.8.1(CON)
A01.8.2(CON)
A01.8.3(CON)
A01.8.4(CON)
V01.8.1(CON)
V01.8.2(CON)
V01.8.3(CON)
V01.8.4(CON)
CONDUIT#2
V01.4.1(CON)
L6(CON)
D(CON)
SEE SHEET 01.FA.503-C FOR
FIRE ALARM DEVICES IN THIS
AREA
LF3
DHP
N008L03M050L3
D A08.3.5 V01.4.4 V08.3.5 V08.3.6 V08.3.7
LF3
LF2
LF1
A08.3.1 A08.3.2 V08.3.1 V08.3.2 L3
DHP
LF3
L3
(2)1" CONDUITS
V01.4.1
D(CON)
ELEC
DATA / TELECOMM
ELEC
DATA / TELECOMM
CHUTE
ELEV
STAIR
STAIR
RECEPT
DIALYSIS CHAIR 5
DIALYSIS CHAIR 6
ISO BED STATION
ISO PAT TLT
PAT ED KIOSK
WAIT/RECEP
MEDICAL CENTER
DIR
CHIEF OF STAFF 1
CHIEF OF STAFF 4
CHIEF OF STAFF 3
CHIEF OF
STAFF 2
OFFICE 1
HSS ASST 1
HSS ASST 2
HSS ASST 3
HSS ASST 4 HSS ASST 5
HSS ASST 6
OFFICE 2
STRETCHER/W. C.
ALCOVE
SOC WORK 1
NEURO VOCA
REHAB PSYCH OFFICE 7
INTERN 2
INTERN 4
WORKSTATION 1
WORKSTATION 2
CONF
CONF
CONSULT 1
CONSULT 2
WORKSTATION 1
WORKSTATION 3
WORKSTATION 4
WORKSTATION 2
SCHED
WORKSTATION 1
EXAM 1
MULTIPURPOSE/CONTROL
HEALTH PSYCH
PSYCH OFFICE 1
PSYCH OFFICE 4
PSYCH OFFICE 3
PSYCH OFFICE 2
PSYCH OFFICE 10
PSYCH OFFICE 6
PSYCH OFFICE 5
COMM CTR
PSYCH OFFICE 9
PSYCH OFFICE 8
CLASSROOM 2
CLASSROOM 1
NOURISH
NURSE STATION
MED PREP
CRASH CART
ALCOVE
EQUIP PROC
EQUIP REPAIR
DIALYSATE PREP
WATER TREAT
HAC 1
CONSULT 1
STAFF TLT 1
EQUIP STOR
CONSULT 2
WAIT
SOILED UTIL
CLEAN SUPPLYSTAFF TLT 1
NP PHY 1
NP PHY 2
NP PHY 3
NP PHY 4
RES
WORKSTATION 1
CHIEF OFFICE
CHIEF NURSE 1
ASST DIET 1
SUPP TECH 1
STAFF LOUNGE
STAFF LOCKERS
WAIT
WORKSTATION 1 WORKSTATION 2
SHARED OFFICE
SEC OFFICE
MAN SPEC CBNP 1
MAN SPEC CBN 2
MAN SPEC CBN 3
MAN SPEC CBN 4
MAN SPEC 1
MAN SPEC 2
MAN SPEC 3
MAN SPEC 4
MAN SPEC 5
MAN SPEC 6
MAN SPEC 7
MAN SPEC 8 MAN SPEC 9
CONSULT
PERS ASST 2
PERS ASST 3PERS ASST 5
PERS ASST 6
PERS ASST 7
CONSULT
WORKSTATION 1
WORKSTATION 2
PERS ASST 4
WORKSTATION 3
WORKSTATION 4
WORKSTATION 5
CONF
WORK
CHIEF OFFICE
BIOFEEDBACK
LAB
BIOFEEDBACK
TECH
SEC 1
WAIT
CONF
STAFF ASST 3
STAFF ASST 4
STAFF ASST 5
STAFF ASST 6
WORK ALCOVE
SECURE WORK
STAFF TLT
CHIEF OFFICE
SHARED OFFICE
PUBLIC TLT 2
EXAM
PUBLIC TLT 1
PIV ROOM
GROUP TEST
EXAM 1
DEPUTY
CHIEF OF
STAFF
STAFF ASST 7
PSYCH OFFICE 11
STAFF TLT
VISN OFFICE 1
VISN OFFICE 2
VITAL SIGNS
PUBLIC TLT 1
PUBLIC TLT 2
CONTROL
HAC 3
STAFF TLT
INTERN 3
INTERN 1
PERS ASST 8
ELEV LOBBY
CORRIDORCORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
PSYCH OFFICE 12
COMM CTR
PUBLIC TLT 3
LAB
CORRIDOR
CORRIDOR
WAIT
DIALYSIS CHAIR 3
DIALYSIS CHAIR 4
DIALYSIS CHAIR 2
DIALYSIS CHAIR 1
CLEAN LINEN
WAIT
CORRIDOR
CORRIDOR
SP
SS
A08.3.3 V08.3.3
A08.3.3 V08.3.3
(2)A08.3.4 (2)V08.3.5
A08.3.4 V08.3.5
(2)A08.3.4
A08.3.4 V08.3.4
A08.3.5 V08.3.7
V08.3.2
L3 P
SS
SS
CONDUIT#1
A01.8.1(CON)
A01.8.2(CON)
A01.8.3(CON)
A01.8.4(CON)
V01.8.1(CON)
V01.8.2(CON)
V01.8.3(CON)
V01.8.4(CON)
CONDUIT#2
V01.4.1(CON)
L6(CON)
D(CON)
CONDUIT#1
A01.8.1(CON)
A01.8.2(CON)
A01.8.3(CON)
A01.8.4(CON)
V01.8.1(CON)
V01.8.2(CON)
V01.8.3(CON)
V01.8.4(CON)
CONDUIT#2
V01.4.1(CON)
L6(CON)
D(CON)
J
J
J
(2)A08.3.2
J
R
(2)L3
(2)L3
DHP
(2)L3 (2)L3
(2)L3 N008L03M002
J L3
(2)L3
R (2)L3
43 RELAY TO CONTROL 24VDC POWER TO REMOTE INDICATOR LIGHTS.
D E
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
E V
R
E
A
L A
O
A
N
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
SS
SP
SP
SP
SS
A08.4.1 V08.4.1
FIBER DOWN TO
DATA/TELECOMM
08-01-E2-T2
ON LEVEL 1
08-AHU-2
RETURN
08-AHU2
SUPPLY
08-AHU-4
SUPPLY
08-AHU-4
RETURN
08-AHU-1
SUPPLY
08-AHU-3
RETURN
08-AHU-3
SUPPLY
08-FCU-8
SUPPLY
08-FCU-9 SUPPLY
08-FCU-9 SUPPLY
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
08-FCU-8 SUPPLY
FAN SHUTDOWN (RLY2)
08-WCPU4
SHUTDOWN
1" CONDUIT
1" CONDUIT
ELEV SE5 SHUNT TRIP (08-EQHP1)
J
C
L4 P
L4
L4
L4L4
V08.4.1
L4 C
L4
(2)L4
L4
L4
F
L4
A08.4.1 V08.4.1
L4
V01.4.4
LF3
LF2
LF1
D
A08.4.1 V08.4.1
A08.4.1
A08.4.1A08.4.1A08.4.1
A08.4.1
A08.4.1 V08.4.1
A08.4.1 V08.4.1
A08.4.1
A08.4.1 V08.4.1
A08.4.1 V08.4.1
A08.4.1
C
C (2)L4
(2)A08.4.1 V08.4.1
A08.4.1 V08.4.1
L4
LF4
P
LF4
P
(2)P L4
(2)P
L4
D
D
L4
F
THIS AREA HAS A SEPARATE FIRE ALARM SYSTEM. SEE WESTFIRE SHOP DRAWINGS FOR
ADDITIONAL SUPPRESSION SYSTEM NOTIFICATION DEVICES AND CONTROLS.
F
L4
(2)L4 T
L4 T
T
P
C
(2)L4
(2)L4 T
LF4
L4
LF4
L4
LF4
L4
F
F
H
G
F
E
D
C
B
A
J
H
G
F
E
D
C
B
A
J
L4
FACP NETWORK
ADDRESS 08
DVC NETWORK
ADDRESS 58
(2)L4
(2)L4
L4
A08.4.1 V08.4.1
(2)L4 C
08-AHU-3 SUPPLY
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
STATUS TO BAS (RLY1)
08-AHU-3 RETURN
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
08-AHU-4 RETURN
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
08-FCU12 SUPPLY
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
08-AHU-2 SUPPLY
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
08-AHU-2 RETURN
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
EOL-47K, 1/2W.
EOL-47K, 1/2W.
2.2K, 1/2W.
08-AHU-2 SUPPLY DAMPER
STATUS TO BAS (RLY1)
DAMPER CONTROL (RLY2)
08-AHU-2 RETURN DAMPER
STATUS TO BAS (RLY1)
DAMPER CONTROL (RLY2)
08-AHU-4 RETURN DAMPER
STATUS TO BAS (RLY1)
DAMPER CONTROL (RLY2)
08-AHU-4 SUPPLY DAMPER STATUS
TO BAS (RLY1)
DAMPER CONTROL (RLY2)
08-AHU-1 SUPPLY DAMPER
STATUS TO BAS (RLY1)
DAMPER CONTROL (RLY1)
08-AHU-3 RETURN DAMPER STATUS
TO BAS (RLY1)
DAMPER CONTROL (RLY2)
08-AHU-3 SUPPLY DAMPER STATUS
TO BAS (RLY1)
DAMPER CONTROL (RLY2)
(2)L4
LF4
L4
FIBER DOWN TO
DATA/TELECOMM
08-01-H2-T3
ON LEVEL 1
L4
(2)P
1-1/4" RISER CONDUIT DOWN TO
ELEC 08-01-D2-E1
2" RISER CONDUIT DOWN TO
ELEC 08-03-G2-E2
ELEV SE5 SHUNT TRIP POWER SUPERVISION (08-EQLP1-30)
P
ELEC
ELEC
VEST
ELEV
VEST
STAIR
HEAD AND EQUIP
RM
MAIN ELEC RM
EMERGENCY
ELEC RM
DHCP COMP RM
NON DHCP COMP
RM
WORKROOM 1
PHONE EQUIP
WORKROOM 2
VISTA IMAGING
PACS QC
DATA CENTER
DATA CENTER
MECH GALLERY
MECH
STAIR
(2)L4
J J
(2)L4
(2)L4 T
(2)L4 T
(2)L4
(2)L4
(2)L4 T
(2)L4 T
(2)L4
(2)L4
LF4
L4
J J
08-AHU-4 SUPPLY
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
L4
L4
(2)L4
(2)L4 T
L4 T
(2)L4 (2)L4
(2)L4
(2)L4 T
(2)L4 T
J
08-AHU-4 SUPPLY
FAN SHUTDOWN (RLY2)
STATUS TO BAS (RLY1)
J
(2)L4
(2)L4 T
(2)L4 T
(2)L4
J
T
L4
(2)L4 T
(2)L4
(2)L4
(2)L4 T
L4 T
(2)L4
(2)L4
(2)L4 T
LF4
L4
J
L4 C
J
C
J (2)L4 C
C
EOL-47K, 1/2W.
EOL-47K, 1/2W.
(2)L4
L4
P
J
(2)L4 C
P
J (2)L4
LF4
L4 LF4
L4
J
J
L4
L4
(2)L4
L4
T LF4
(2)L4
(2)L4
(2)L4 T
A08.4.1 V08.4.1
A08.4.1 V08.4.1
J
A08.4.1 V08.4.1
A08.4.1 V08.4.1
A08.4.1 V08.4.1
J
P
L4 P
J
(2)L4
L4
J
J
08-WCPU5
SHUTDOWN
P
L4
FIRE ALARM / PUBLIC ADDRESS
INTERFACE CABINET
TO PA HEAD END
(18)C FIRE ALARM / PUBLIC ADDRESS INTERFACE CABINET
L4
D E
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
E N
T H
O U
V
R
E
A
L A
O
A
N
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
GP-107A
EMERGENCY
ELEC RM
G1-112
WAIT
NETWORK
ADDRESS
G1-337
ELEC
G1-327
DATA / TELECOMM
G1-345
DATA / TELECOMM
G1-ST1
STAIR
IN FROM CONCOURSE
(SYNC GENERATOR - V01.4.4)
G2-339
DATA / TELECOMM
G2-331
ELEC
G2-321
DATA / TELECOMM
G3-323
DATA / TELECOMM
G3-198
ELEC
G3-192
DATA / TELECOMM
NETWORK FIBER
TO CON-TR-0B
NETWORK FIBER
FROM PSN TR-0B
FI
BE
R
NE
TW
OR
K
RI
SE
R
LE
VE
L 1 T
O
PE
NT
HO
US
E
FI
BE
R
NE
TW
OR
K
RI
SE
R
LE
VE
L 1 T
O
PE
NT
HO
US
E
GP-106
HEAD AND EQUIP
RM
GP-109
MECH
CB
N
FI
RE
A
LA
RM
S
YS
TE
M
RI
SE
R
LE
VE
L 1 T
O
LE
VE
L 3
(V01.4.4) CBN SYNC CIRCUIT
(F) FIBER NETWORK CIRCUIT
(F ) F
IB
ER
N
ET
W
OR
K
CI
RC
UI
T
Johnson
Controls
ALL
CALL
08-FPS4
08-FCP
DVC
NETWORK
ADDRESS 58
FCP
NETWORK
ADDRESS 08
08-FPS1
08-FPS2
08-FPS3
(F) FIBER NETWORK CIRCUIT(F) FIBER NETWORK CIRCUIT
08-01-G4-02
08-01-H2-T3 08-01-G2-E2
08-01-E2-T2
08-01-ST1
08-02-E2-T1
08-02-G2-E2 08-02-H2-T2
08-03-H2-T2
08-03-G2-E2
08-03-E2-T1
08-PH-E2-Q1
08-PH-G3-01
08-PH-E4-E1
(F) FIBER NETWORK CIRCUIT
D E
S C
R I P
T I O
N D
A T
E
C B
N
N
E T
W O
K
N
C H
R O
N I Z
A T
I O
N
R
I S
A
G R
A M
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
A08.1.1
A08.1.3
A08.1.2
SYNC CIRCUIT FROM
CONCOURSE BUILDING
(V01.4.4)
V08.1.5
V08.1.4
V08.1.3
.5W .5W.5W .5W.5W .5W
.5W.5W .5W .5W
.5W .5W .5W.5W .5W.5W .5W
.5W .5W .5W .5W .5W.5W
.5W .5W
V08.1.6
G1-345
DATA / TELECOMM
08-01-E2-T2
DATA / TELECOMM
G1-317
ELEC
.5W
V01.4.1 (CONCOURSE SYNC CIRCUIT)
D (CONCOURSE DAL CIRCUIT)
OUT TO
CONCOURSE
CONTINUED LEVEL 2
(D ) C
BN
D
IG
IT
AL
A
UD
IO
LO
OP
(F ) F
IB
ER
U P
TO
F
CP
V01.4.1 (CONCOURSE SYNC CIRCUIT)
D (CONCOURSE DAL CIRCUIT)
SELECTION
SELECTION
PREVIOUS
NEXT
LAMP F1
DISABLE
TEST
SCREEN
ENABLE
BATTERY
LEVELS
F2
NETWORK
ANNUNCIATOR
Johnson
Controls
G1-112
WAIT
FSA
NETWORK
ADDRESS 108
G1-337
ELEC
(F ) F
IB
ER
N
ET
W
OR
K
CI
RC
UI
T
CONTINUED LEVEL 2
(F) FIBER NETWORK CIRCUIT
120VAC
POWER
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
08-FPS1
BATTERY CABINET
FIRE
ALARM
TERMINAL
CABINET
08-FTC1
08-DPS1
(LF1) SLC-LOOP 1 FEED
(D ) C
BN
D
IG
IT
AL
A
UD
IO
LO
OP
(V
.4.
4)
C
BN
S
YN
C
CI
RC
UI
T (L
F1 ) S
LC
-L
OO
P
1 F
EE
D
(D) CBN DIGITAL AUDIO LOOP
(LF1) SLC-LOOP 1 FEED
(LF1) SLC-LOOP 1 FEED
(P) 24VDC POWER
A08.1.6
V08.1.7
(P) 24VDC POWER
V01.4.4 (CBN SYNC CIRCUIT)
(P) 24VDC POWER
DHP
NETWORK FIBER
FROM PSN-TR-0B VIA CBN-TR-1A
NETWORK FIBER
IN FROM 08-FSA VIA CBN-TR-1A
.5W
A08.1.6
V08.1.7
V08.1.2
V08.1.1
A08.1.5
(V
.4.
4)
C
BN
S
YN
C
CI
RC
UI
T (P
) 2 4V
DC
P
OW
ER
(L F1
) S
LC
-L
OO
P 1 F
EE
D
A0 8.1
.6 V0
8.1 .7
WP
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
15 15 15 15 15
15 15 15 15 15
151515151515
V08.1.6(U)
08-01-D2-E1
08-01-H2-T3
08-01-G4-02
08-01-G2-E2
(L1) SLC-LOOP 1
(L1) SLC-LOOP 1
(LF1) SLC-LOOP 1 FEED
DOES THIS GO BACK TO
THE PANEL? LONG WAYS
TO GO!!
(L1) SLC LOOP 1
.5W
(P) 24V PWR
15 15 15 15
D E
S C
R I P
T I O
N D
A T
E
C B
N
S
E R
V I C
E
A
V
R
E
A
L A
S
A
G R
A M
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
.5W.5W .5W .5W
.5W.5W .5W .5W.5W
.5W .5W .5W .5W .5W .5W .5W
.5W .5W .5W
(F ) N
ET
W
OR
K
CI
RC
UI
T
OUT TO
CONCOURSE
CONTINUED LEVEL 3
G2-311
ELEC
A01.7.1 A01.7.2 A01.7.3 V01.7.1 V01.7.2 V01.7.3
L6(CON)
DHP(CON)
V01.4.1 (CONCOURSE SYNC CIRCUIT)
D (CONCOURSE DAL CIRCUIT)
V01.4.1 (CONCOURSE SYNC CIRCUIT)
D (CONCOURSE DAL CIRCUIT)
CONTINUED LEVEL 1
CONTINUED LEVEL 3
(D -C
IC
) C
BN
D
IG
IT
AL
A
UD
IO
LO
OP
CONTINUED LEVEL 1
(F ) F
IB
ER
N
ET
W
OR
K
CI
RC
UI
T (F
) F
IB
ER
N
ET
W
OR
K
CI
RC
UI
T
120VAC
POWER
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
(D) CBN DIGITAL AUDIO LOOP
(V01.4.4) CBN SYNC CIRCUIT
(LF1) SLC-LOOP 1 FEED
08-FPS2
BATTERY CABINET
FIRE
ALARM
TERMINAL
CABINET
08-FTC2
08-DPS2
(D ) C
BN
D
IG
IT
AL
A
UD
IO
LO
OP
(V
.4.
4)
C
BN
S
YN
C
CI
RC
UI
T
(L F1
) S
LC
-L
OO
P 1 F
EE
D
(L F2
) S
LC
-L
OO
P 2 F
EE
D
V08.2.1
V08.2.2
V08.2.4
A08.2.2
A08.2.1
V08.2.3
A08.2.6
A08.2.5
(P) 24V PWR
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
15 15 15 15
08-02-D2-E1
G2-331
ELEC
08-02-G2-E2
(L2) SLC-LOOP 2
(L2) SLC-LOOP 2
(LF2) SLC-LOOP 2 FEED
(LF2) SLC-LOOP 2 FEED
(L2) SLC LOOP 2
(L2) SLC LOOP 2
DHP
D E
S C
R I P
T I O
N D
A T
E
C B
N
L
E V
R
E
A
L A
S
A
G R
A M
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
A08.3.1 .5W.5W .5W .5W.5W .5W .5W
.5W.5W .5W
.5W .5W
.5W.5W
.5W .5W .5W
.5W .5W
A08.3.2
A08.3.3
A08.3.4
V08.3.1
V08.3.2
V08.3.3
V08.3.4
G3-198
ELEC
CONTINUED PENTHOUSE LEVEL
(D ) C
BN
D
IG
IT
AL
A
UD
IO
LO
OP
CB
N
FI
BE
R
NE
TW
OR
K
CI
RC
UI
T
CONTINUED LEVEL 2
OUT TO
CONCOURSE
G3-313
ELEC
V01.4.1 (CONCOURSE SYNC CIRCUIT)
D (CONCOURSE DAL CIRCUIT)
(2)1" CONDUITS
CONDUIT #1
A01.8.1 A01.8.2 A01.8.3 A01.8.4 V01.8.1 V01.8.2 V01.8.3 V01.8.4
CONDUIT #2
V01.4.1
L6(CON)
D(CON)
CONTINUED LEVEL 2
CONTINUED PENTHOUSE LEVEL
(F ) F
IB
ER
N
ET
W
OR
K
CI
RC
UI
T
120VAC
POWER
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
(D ) C
BN
D
IG
IT
AL
A
UD
IO
LO
OP
(V
.4.
4)
C
BN
S
YN
C
CI
RC
UI
T (L
F3 ) S
LC
-L
OO
P
3 F
EE
D
(L F1
) S
LC
-L
OO
P 1 F
EE
D
(D) CBN DIGITAL AUDIO LOOP
(V01.4.4) CBN SYNC CIRCUIT
(LF1) SLC-LOOP 1 FEED
(LF2) SLC-LOOP 2 FEED
08-FPS3
BATTERY CABINET
FIRE
ALARM
TERMINAL
CABINET
08-FTC3
08-DPS3
V08.3.5
V08.3.6
V08.3.7
A08.3.5
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
15151515
.5W
.5W
.5W
.5W
15151515
08-03-D2-E1
08-03-G2-E2
(L F2
) S
LC
-L
OO
P 2 F
EE
D
(LF3) SLC-LOOP 3 FEED
(L3) SLC-LOOP 3
(L3) SLC-LOOP 3
(P) 24V PWR
(L3) SLC LOOP 3
SS
(L3) SLC LOOP 3
(LF3) SLC-LOOP 3 FEED
DHP
D E
S C
R I P
T I O
N D
A T
E
C B
N
L
E V
R
E
A
L A
S
A
G R
A M
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
(L4) SLC-LOOP 4
GP-107A
EMERGENCY
ELECTRICAL
ROOM
.5W.5W.5W .5W .5W .5W .5W .5W .5W .5W
ALARM SUPERVISORY TROUBLE
- CLEAN AGENT FIRE EXTINGUISHING PANEL -
V08.4.1
A08.4.1
(D ) C
BN
D
IG
IT
AL
A
UD
IO
LO
OP
(F ) C
BN
F
IB
ER
N
ET
W
OR
K
CI
RC
UI
T
CONTINUED LEVEL 3
CONTINUED LEVEL 3
JDVC
NETWORK
ADDRESS 58
FACP
NETWORK
ADDRESS 08
LAMP TEST
TROUBLE
DVC OFF-LINE
MICROPHONE
TROUBLE
PHONE
TROUBLE
BUSY/WAIT
PAGE
INHIBITED
PRE/POST
ANNOUNCE TONE
POWER
ALL
CALL
PAGE
ACTIVE
EVAC
AREAS
ENABLE
TELEPHONE
PAGE
PAGE
ACTIVE
ALERT
AREAS
PAGE
INACTIVE
AREAS
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
Johnson
Controls
120VAC
POWER
120VAC
POWER
FIRE
ALARM
TERMINAL
CABINET
08-FTC4
08-FCP
08-FPS4
BATTERY CABINET
08-FCP
BATTERY CABINET
SYNC CKT.
EOL
(D ) C
BN
D
IG
IT
AL
A
UD
IO
LO
OP
(V
.4.
4)
C
BC
S
YN
C
CI
RC
UI
T (L
F3 ) S
LC
-L
OO
P
3 F
EE
D
(L F1
) S
LC
-L
OO
P 1 F
EE
D
(F ) C
BN
F
IB
ER
N
ET
W
OR
K
CI
RC
UI
T
(L F2
) S
LC
-L
OO
P 2 F
EE
D
(D) CBN DIGITAL AUDIO LOOP
(F) CBN FIBER NETWORK CIRCUIT
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
.5W
(P) 24VDC POWER (P) 24VDC POWER
(P) 24VDC POWER
08-PH-E4-E1
WP
(LF4) SLC-LOOP 4 FEED
(L4) SLC-LOOP 4
(LF4) SLC-LOOP 4 FEED
(LF4) SLC-LOOP 4 FEED
(L4) SLC-LOOP 4
(L4) SLC-LOOP 4
(L4) SLC-LOOP 4
.5W
(LF4) SLC-LOOP 4 FEED
FIRE ALARM TO PUBLIC ADDRESS
SYSTEM INTERFACE
QTY 3 - XP6-R RELAY BOARDS
N008L04M031 - N008L04M047
CBN-HER-P
D E
S C
R I P
T I O
N D
A T
E
C B
N
P
E N
T H
O U
V
R
E
A
L A
S
A
G R
A M
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
LAMP TEST
TROUBLE
DVC OFF-LINE
MICROPHONE
TROUBLE
PHONE
TROUBLE
BUSY/WAIT
PAGE
INHIBITED
PRE/POST
ANNOUNCE TONE
POWER
ALL
CALL
PAGE
ACTIVE
EVAC
AREAS
ENABLE
TELEPHONE
PAGE
PAGE
ACTIVE
ALERT
AREAS
PAGE
INACTIVE
AREAS
CAMPUS
WIDE
CON ALL CALL
RES ALL CALL
DAT ALL CALL
IBS ALL CALL
IBN ALL CALL
ENC ALL CALL
CLC ALL CALL
CBN ALL CALL
CBC ALL CALL
CBS ALL CALL
PVN ALL CALL
PVS ALL CALL
(FUTURE)
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
LAMP TEST
TROUBLE
DVC OFF-LINE
MICROPHONE
TROUBLE
PHONE
TROUBLE
BUSY/WAIT
PAGE
INHIBITED
PRE/POST
ANNOUNCE TONE
POWER
ALL
CALL
PAGE
ACTIVE
EVAC
AREAS
ENABLE
TELEPHONE
PAGE
PAGE
ACTIVE
ALERT
AREAS
PAGE
INACTIVE
AREAS
Johnson
Controls
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
NOTIFICATION
DOOR HOLDER
ELEV RECALL
HVAC / FSD
BYPASS
BYPASS
BYPASS
BYPASS
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
CBN SRV LEVEL
PAGE
CBN LEVEL 1
PAGE
CBN LEVEL 2
PAGE
CBN LEVEL 3
PAGE
CBN PENTHSE
PAGE
CON ALL CALL
RES ALL CALL
DAT ALL CALL
IBS ALL CALL
IBN ALL CALL
ENC ALL CALL
CLC ALL CALL
CBN ALL CALL
CBC ALL CALL
CBS ALL CALL
PVN ALL CALL
PVS ALL CALL
(FUTURE)
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
NOTIFICATION
DOOR HOLDER
ELEV RECALL
HVAC / FSD
BYPASS
BYPASS
BYPASS
BYPASS
SPARE
SPARE
CBN SERVICE
LEVEL PAGE
CBN LEVEL
3 PAGE
CBN LEVEL
1 PAGE
CBN LEVEL
2 PAGE
SPARE
SPARE
SPARE
SPARE
CAMPUS CAMPUS
BLDG A ALARM
BLDG B ALARM
BLDG C ALARM
BLDG D/F ALARM
BLDG E ALARM
BLDG G ALARM
BLDG H ALARM
BLDG K ALARM
BLDG L ALARM
BLDG PE ALARM
BLDG PN ALARM
BLDG PS ALARM
BLDG A TRBL
BLDG B TRBL
BLDG C TRBL
BLDG D/F TRBL
BLDG E TRBL
BLDG G TRBL
BLDG H TRBL
BLDG K TRBL
BLDG L TRBL
BLDG PE TRBL
BLDG PN TRBL
BLDG PS TRBL
BLDG A SUPV
BLDG B SUPV
BLDG C SUPV
BLDG D/F SUPV
BLDG E SUPV
BLDG G SUPV
BLDG H SUPV
BLDG K SUPV
BLDG L SUPV
BLDG PE SUPV
BLDG PN SUPV
BLDG PS SUPV
CBN PENT
LEVEL PAGE
PUBLIC SAFETY
NORMAL AC
POWER
LOSS OF NORMAL
AC POWER
SIGNAL FAILURE /
BOOSTER TRBL
BATTERY CHGR
TROUBLE
LOW BATTERY
CAPACITY
RADIO SYSTEM
CAMPUS CAMPUS
BLDG A ALARM
BLDG B ALARM
BLDG C ALARM
BLDG D/F ALARM
BLDG E ALARM
BLDG G ALARM
BLDG H ALARM
BLDG K ALARM
BLDG L ALARM
BLDG PE ALARM
BLDG PN ALARM
BLDG PS ALARM
BLDG A TRBL
BLDG B TRBL
BLDG C TRBL
BLDG D/F TRBL
BLDG E TRBL
BLDG G TRBL
BLDG H TRBL
BLDG K TRBL
BLDG L TRBL
BLDG PE TRBL
BLDG PN TRBL
BLDG PS TRBL
BLDG A SUPV
BLDG B SUPV
BLDG C SUPV
BLDG D/F SUPV
BLDG E SUPV
BLDG G SUPV
BLDG H SUPV
BLDG K SUPV
BLDG L SUPV
BLDG PE SUPV
BLDG PN SUPV
BLDG PS SUPV
D E
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
F
Q U
I P
M E
B
I N
W
R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
F
P S
E
Q U
I P
M E
B
I N
R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
F
P S
E
Q U
I P
M E
B
I N
R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
F
P S
E
Q U
I P
M E
B
I N
R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
F
P S
E
Q U
I P
M E
B
I N
R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
A
P
A
I N
T E
R F
A C
E
C
A B
I N
R
I N
G
D
E T
A I L
S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
CBN LEVEL 1
ELEC 08-01-G2-E2 (G1-337)
NORTH WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FIRE
ALARM
TERMINAL
CABINET
2"
2'-0
6'
2"
7"
7"
4'-6
1"
3/4" CONDUIT
FOR 120VAC
POWER
FLOOR
FPS
BB-100
3/4" CONDUIT
3/4"
CONDUIT
FOR 120VAC
POWER
DPS
FTC
PARTITION WALL
4'-11
WEST WALL
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
DITEK TSS4
3/4" LL
CONDULET
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(08-LSL12-1)
2"
N
2" GRC COUPLING W/
2" CHASE NIPPLES
EAST WALL
DOORWAY
4'
4"
2'
(4) 1"
CONDUITS
FOR FIRE
ALARM
CABLES
3/4" CONDUIT OUT
TO DOORHOLDERS
2" RISER CONDUIT
UP TO 2ND LEVEL
08-DPS1
08-FPS1
CBN LEVEL 2
ELEC 08-02-G2-E2 (G2-331)
NORTH WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FIRE
ALARM
TERMINAL
CABINET
2"
2'-0
6'
2"
7"
7"
4'-6
1"
3/4" CONDUIT
FOR 120VAC
POWER
FLOOR
FPS
BB-100
3/4" CONDUIT
3/4"
CONDUIT
FOR 120VAC
POWER
DPS
FTC
PARTITION WALL
4'-11
WEST WALL
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
DITEK TSS4
3/4" LL
CONDULET
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(08-LSL32-7)
2"
N
2" GRC COUPLING W/
2" CHASE NIPPLES
EAST WALL
DOORWAY
2" RISER CONDUIT
DOWN TO 1ST LEVEL
4'
4"
2'
(4) 1"
CONDUITS
FOR FIRE
ALARM
CABLES
3/4" CONDUIT OUT
TO DOORHOLDERS
2" RISER CONDUIT
UP TO 3RD LEVEL
08-DPS2
08-FPS2
08-01-G2-E2
ELEC
08-FPS1
08-FTC1
BB100
UNDERNEATH
TSS4
CBN LEVEL 1
ELEC 08-01-G2-E2 (G1-337)
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
08-DPS1
DPS
MONITOR
MODULE
08-02-G2-E2
ELEC
CBN LEVEL 2
ELEC 08-02-G2-E2 (G2-331)
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
08-FPS2
08-FTC2
BB100
UNDERNEATH
TSS4
08-DPS2
DPS
MONITOR
MODULE
CBN LEVEL 2
ELEC 08-02-D2-E1 (G2-311)
NORTH WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FIRE
ALARM
TERMINAL
CABINET
2"
2'-0
6'
2"
7"
7"
4'-6
1'-4
3/4" CONDUIT
FOR 120VAC
POWER
FLOOR
FPS
BB-100
3/4" CONDUIT
3/4"
CONDUIT
FOR 120VAC
POWER
DPS
FTC
PARTITION WALL
6'-3
WEST WALL
DTK-TSS4
INPUT
OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
DITEK TSS4
3/4" LL
CONDULET
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(PANEL/CIRCUIT# TBD)
2"
N
2" GRC COUPLING W/
2" CHASE NIPPLES
1"
EAST WALL
DOORWAY
2" RISER CONDUIT
DOWN TO 1ST LEVEL
4'
4"
2'
(4) 1"
CONDUITS
FOR FIRE
ALARM
CABLES
3/4" CONDUIT OUT
TO DOORHOLDERS
2" RISER CONDUIT
UP TO 3RD LEVEL
01-DPS2
01-FPS7
CBN LEVEL 3
ELEC 08-03-G2-E2 (G3-198)
NORTH WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FIRE
ALARM
TERMINAL
CABINET
2"
2'-0
6'
2"
7"
7"
4'-6
1"
3/4" CONDUIT
FOR 120VAC
POWER
FLOOR
FPS
BB-100
3/4" CONDUIT
3/4"
CONDUIT
FOR 120VAC
POWER
DPS
FTC
PARTITION WALL
4'-11
WEST WALL
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
DITEK TSS4
3/4" LL
CONDULET
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(08-LSL32-5)
2"
N
2" GRC COUPLING W/
2" CHASE NIPPLES
EAST WALL
DOORWAY
2" RISER CONDUIT
DOWN TO 2ND LEVEL
4'
4"
2'
(4) 1"
CONDUITS
FOR FIRE
ALARM
CABLES
3/4" CONDUIT OUT
TO DOORHOLDERS
2" RISER CONDUIT
UP TO PENTHOUSE LEVEL
08-DPS3
08-FPS3
08-02-D2-E1
ELEC
CBN LEVEL 2
ELEC 08-02-D2-E1 (G2-311)
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
01-FPS7
01-FTC3
BB100
UNDERNEATH
TSS4
01-DPS2
DPS
MONITOR
MODULE
08-03-G2-E2
ELEC
CBN LEVEL 3
ELEC 08-03-G2-E2 (G3-198)
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
08-FPS3
08-FTC3
BB100
UNDERNEATH
TSS4
08-DPS3
DPS
MONITOR
MODULE
08-03-D2-E1
ELEC
CBN LEVEL 3
ELEC 08-03-D2-E1 (G2-311)
FLOOR PLAN VIEW
SCALE: 1/2" = 1'0"
N
F
P S
F
T C
BB100
BELOW
T S
S
CBN LEVEL 3
ELEC 08-03-D2-E1 (G2-311)
PARTITION WALL
FIRE ALARM PANEL ELEVATION
SCALE: 3/4" = 1'0"
FLOOR
NORTH WALL
N
PARTITION WALL
SOUTH WALL
5'-7
2"
2'-0
" 7
6'
4'
4"
2'
4'-4"
(4) 1"
CONDUITS
FOR FIRE
ALARM
CABLES
FPS
BB-100
3/4" CONDUIT
3/4" CONDUIT
FOR 120VAC
POWER
DTK-TSS4
INPUT OUTPUT
LINE
NEUTRAL
LINE
NEUTRAL
GROUND
ELECTRICIANS TO
PROVIDE 120VAC
POWER TO SURGE
SUPPRESSOR FOR
NAC POWER SUPPLY
(PANEL/CIRCUIT #TBD)
DITEK TSS4
3"
ALARM
TERMINAL
CABINET
7"
7"
FTC
1" RISER CONDUIT OUT
TO 01-FPS9 ON LEVEL 3
CBc ELEC 09-03-D2-E1
2" GRC COUPLING W/
2" CHASE NIPPLES
2" RISER CONDUIT
DOWN TO LEVEL 2
FIRE
01-FPS8
D E
S C
R I P
T I O
N D
A T
E
C L
I N
I L
D I N
G
N
O R
E V
E L
S
Q U
I P
M E
N
E
V A
T I O
N S
A U
R O
R A
C
O L
O R
A D
O
E A
S T
E R
N
C
O L
O R
A D
O
H
E A
L T
H
C
A R
E
S
Y S
T E
M
R E
P L
A C
E M
E N
T
M
E D
I C
N
T E
R
F
A C
I L
I T
Y
D E
P A
R T
M E
V
E T
E R
A N
S
A
F F
A I R
S
AS-BUILT
01-04-2018
File details come from the government source that posted it. Updated .