8. Functional Statement
a. Equipment Request: Complete Self-Contained battery operated mobile radiographic digital X-ray imaging system designed for performing radiographic exams at the point of care.
b. Functional Statement: New equipment must be a complete self-contained mobile radiographic system. Equipment must include but not limited to:
· Flash pad HD digital wireless detector
· Rapid Readout
· Low Noise Electronics
· Ability to image bariatric patients (surface area and weight limits)
· 14 x 17 detector area that is not excessive in weight
· Image Display Workstation
· Touch screen monitor
· Image annotation and measurement tools
· Electronic Left/Right Markers
· Multi-resolution post processing
· Customizable image processing to match user preferences
· Operational and Diagnostic Software based on secure operating system
· Image optimization
· Key features
· Compatible with digital wireless detectors
· Digital wireless detectors batteries charge automatically while the detector(s) are in the bin regardless if the system is on or in standby mode.
· Digital wireless detectors may be shared across compatible systems within the healthcare facility by all users.
· Automatic safety brake
· Integration of front bumper stop which activates brakes
· Dose Area Product Meter (DAP)
· 30KW generator
· Capable of 100 – 240V nominal, 50/60Hz operation
· System may be driven within 4 seconds of activation
· Stand-by mode eliminates boot up cycles and allows the start of the imaging exam within 20 seconds.
· Exposures may be taken and processed while the unit is charging
· Single integrated user interface for techniques, image acquisition and display tools.
· Drive inhibit keypad access
· Password protected access to patient
· Compliance with confidentiality regulations
· Patient Management
· Detector Exposure Indicator – tool for detector dose feedback to ensure exposure is within normal limits per default protocol.
· Dose management package
· Emergency Patient Exam Capability
· Allows complete imaging functionality without patient data, assigns a unique patient identifier, and allows merging of the patient information with the exam images.
· Image Display
· Preview image within 30 seconds.
· Fully processed image within 45 seconds.
· Image Processing:
· Tissue Equalization to enhance contrast in under-penetrated or over-penetrated areas.
· Able to determine optimal brightness and contrast for image display
· Image based cropping/shuttering tool that relies on image information to locate the collimator edges present in the image.
· Standard Network Capability
· Ethernet Network Link – DICOM 3.0
· HIS/RIS work list system
· Quality Assurance Program with phantom
· Serviceability
· Provide Telephone support, at minimum, Monday – Friday, 8:00am – 5:00pm.
· On-site service capabilities, at minimum, Monday – Friday, 8:00am – 5:00pm.
· Onsite training for all staff followed by onsite follow-up training within 6 months of system start-up, if needed based on the SVAHCS needs.
10. Delivery Information
a. Equipment must be available and delivered to the Sheridan VA Medical Center within 90 days of award/purchase.