36C25919Q0204
Combined Synopsis/Solicitation for Urinalysis Cost per Reportable Result
ATTACHMENT B – VISN 19 Floor Plans
Floor Plans are in alphabetical Order of VISN 19 Facilities:
1. Billings Community Based Outpatient Clinic (CBOC): 1766 Majestic Lane, Billings, MT 59102
2. Cheyenne VAMC: 2360 East Pershing Blvd, Cheyenne, WY 82001
3. Eastern Oklahoma VA (Jack C. Montgomery VAMC): 1011 Honor Heights Drive, Muskogee, OK 74401
4. Ernest Childers CBOC: 9322 E.41st Street, Tulsa, OK 74146
5. Fort Collins CBOC: 2509 Research Blvd., Fort Collins, CO 80526
6. Fort Harrison VAMC: 3687 Veterans Drive, P.O. Box 1500, Fort Harrison, MT
59636
7. Grand Junction VAMC: 2121 North Ave. Grand Junction, CO 81501
8. Lawton CBOC: Bldg. 4303, Pitman Street, Fort Sill, OK 73507
9. Loveland CBOC: 5200 Hahn’s Peak Drive, Loveland, CO 80538
10. Oklahoma City VA Health Care System: 921 NE 13th Street, Oklahoma City, OK
73104
11. Rocky Mountain Regional VA Medical Center (VAMC): 1700 Wheeling Street, Aurora, CO 80045
12. Salt Lake City Health Care System: 500 South Foothill Drive, Salt Lake City, UT
84148
13. Sheridan VA Healthcare System: 1898 Fort Road, Sheridan, WY 82801
Room Requirements for Billings, MT. HCC Laboratory
Requirement: Urinalysis 03/06/19
• All outlets are 110 volts.
• Countertops do not come with a weight limit maximum.
• Sink is available on the same counter for analyzer waste stream.
• Countertop space available is 30” deep X 65” wide.
• Temperature is between 17 and 30 degrees Celcius.
• Humidity is between 20 % and 80%
Fort Collins CBOC 2509 research blvd., Fort Collins CO 80526
Fort Collins has one long counter top with 2 possible locations for a Urinalysis strip reader that has 30inches wide by 22.5 inches deep by 36 inches high to work with. Power is 110-120 volts and within 3 feet of either location in the wall behind. The counter will support a instrument up to 200 lbs and no drain is required.
Fort Harrison VA Medical Center
3717 Veterans Drive Lab 113
Fort Harrison, MT 59636
Urinalysis analyzer space requirements
The temporary and permanent location for the Urinalysis machine will be located between C and D on the X axis of the construction document and between 2 and 3 on the Y axis. Please look for “unit location on this attachment.
The temporary counter space is 72 inches in length and 28 inches wide/deep. The analyzer must be under 29 inches in height. The counter cannot support more than 250 lbs. There is no drain in the temporary location, so the analyzer must have the ability to drain into a plastic container. Four 120Volt outlets are in this location.
The Permanent location will be the final location of the analyzer. The counter space is 72 inches in length and 28 inches wide/deep. The analyzer must be under 29 inches in height. The counter cannot support more than 250 lbs. There is no drain in the permanent location, so the analyzer must have the ability to drain into a plastic container. Four 120Volt outlets are in this location.
Grand Junction VA Medical Center 2121 North Avenue
Grand Junction, CO 81501
URINALYSIS ANALYZER SPACE REQUIREMENTS
The temporary location (“Temp” above) will be used during analyzer validation. The counter space is 84 inches wide, 30 inches deep, and 36 inches high. The counter cannot support more than 250 pounds. The drain tube must reach seven feet from the analyzer to the drain. Four 120V outlets are indicted with a star above.
The permanent location (“Perm” above) will be the final location of the analyzer. The counter space is 84 inches wide, 30 inches deep, and 36 inches high. The counter cannot support more than 250 pounds. The drain tube must reach three feet from the analyzer to the drain. Four 120V outlets are indicted with a star above
There is a possible computer location for the analyzer (“COM” above) for ease of use by the staff.
Temporary Location Permanent Location Possible Computer Location
VHAOKLGONZAS
Typewritten Text Bldg 4303 Pitman Street Fort Sill, Oklahoma 73503 Phone: 1-(580) 585-5668 Contact: Salvador G. Gonzalez, MT(ASCP)
VHAOKLGONZAS
Typewritten Text Data Connection>
VHAOKLGONZAS
Typewritten Text
VHAOKLGONZAS
Typewritten Text
VHAOKLGONZAS
Typewritten Text
VHAOKLGONZAS
Typewritten Text
VHAOKLGONZAS
Typewritten Text
* Electrical Outlets (4)
VHAOKLGONZAS
Typewritten Text
VHAOKLGONZAS
Typewritten Text
VHAOKLGONZAS
Line
VHAOKLGONZAS
Typewritten Text Counter Top Weight Capacity 300 Lbs Dimension: Length: 8.5 ft x Height: 32 Inch x Width: 30 Inch
VHAOKLGONZAS
Typewritten Text Urinalysis Location and Dimesions
VHAOKLGONZAS
Typewritten Text Sink
Oklahoma City VAHCS 921 N.E. 13 st Oklahoma City, OK, 73104
Overall View
System 1
System 2
Rocky Mountain Regional VA Medical Center
1700 North Wheeling Street
Aurora, CO, 80045
Urinalysis Floorplan Requirements
• Current Utilization:
o Two Iris and Ichem analyzers o Two sinks for drainage
▪ This could just be routed to a drain if necessary o Six 120-volt outlets
▪ Two uninterruptable power sources (UPS)
▪ Other outlets for additional computers and printers o Four data ports
▪ Two for analyzers
▪ Two for VA computers o Four rolling tables- Two at each Station
▪ 375 lb. weight capacity
▪ Dimensions
• Length: 60 inches
• Width: 30 inches
• Height: 36 inches (floor to table top)
• Height: 72 inches (table top to ceiling)
Blueprint Sketch- Urinalysis workspace marked in Yellow- picture taken at bottom station
Sinks are at the end of each station- 3-120 volt outlets, 2- data ports, and one table at each location
Pathology & Laboratory Medicine VA Salt Lake City Health Care System, MC 113 Authorized by Chief of Pathology 500 Foothill Dr., Salt Lake City, UT 84148
Here are the location plans for SLC VA for the IRIS validation and permanent location when completed.
We have a table that will support the IRIS that will take the place of the table with the microscope seen in the photo. Then it will be permanently be moved to the table where the Clinitek Atlas currently is.
Drain is located on floor behind instrument and power pole (120V) is to left in picture with another drop pole to be installed to the right of the instruments in the picture, also.
The measurements are:
1. Counter top measurements: 7’x3’
2. Floor to counter measurements: 2’11”
3. Counter to ceiling measurements: 5’6”
4. Electrical outlets directly behind analyzer and are compatible with analyzer.
5. Counter top is a stand-alone table adequate to hold weight of analyzer.
6. Floor drain directly behind analyzer.
Pathology & Laboratory Medicine VA Salt Lake City Health Care System, MC 113 Authorized by Chief of Pathology 500 Foothill Dr., Salt Lake City, UT 84148