36C25918R0369-00003000.docx
DOCX document 20 KB Posted
- Solicitation number
- 36C25918R0369
About this file
36C25918R0369 00003 36C25918R0369 00003.docx
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25918R0369-00007000.docx | DOCX document | |
| 36C25918R0369-00006000.docx | DOCX document | |
| 36C25918R0369-00004000.docx | DOCX document | |
| 36C25918R0369-00002003.pdf | ||
| 36C25918R0369-00002002.pdf | ||
| 36C25918R0369-00002000.docx | DOCX document | |
| 36C25918R0369-00002001.pdf | ||
| 36C25918R0369-00001000.docx | DOCX document | |
| 36C25918R0369-001.docx | DOCX document | |
| 36C25918R0369-002.zip | ZIP file | |
| 36C25918R0369-003.docx | DOCX document | |
| 36C25918R0369-004.pdf | ||
| 36C25918R0369-000.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE
OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
BY
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer) 00003 04-17-2018 666-18-109 36C259 Department of Veterans Affairs Network Contracting Office
NCO 19
6162 South Willow Drive, Suite 300 Greenwood Village
CO
80111 36C259 Department of Veterans Affairs Network Contracting Office
NCO 19
6162 South Willow Drive, Suite 300 Greenwood Village
CO
80111 To all Offerors/Bidders
36C25918R0369 04-17-2018
X x x The purpose of this amendment is to include additional answers to questions received.
All other terms and conditions remain the same.
Because of the magnitude of the requested work to be done on tanks #13/14 at the fueling station, and their age from initial installation, I strongly recommend replacement of the two structures and combine into one single structure with two compartments. Otherwise, you may be paying for additional corrective measures soon.
Answer: This was addressed in the amendment verbiage for the SOW. We are asking for the Deductive alternate to replace the tanks in question. Two compartments are acceptable if they are each 1500 gallons.
As a temporary standby storage as requested, and I see only one generator tank at building #86 needing it, would it be practical, and approved to keep onsite, an in pickup 100-gallon auxiliary tank full of diesel that can be transferred to the day tank if needed in an emergency. Answer: Yes, this was spelled out in the amendment and can be used in conjunction with the onsite fuel requirements for the other replacement tanks (13 & 14). If required in an emergency, the standby tank can be brought to the building 86 tank to run for an extended period or to refill the day tank while being replaced. All the other generator tanks would NOT need to be shut down during any activities, only day tanks need to be full while work is being done on each. The fueling facility at building 42, tanks # 13/14, will however need to have some standby storage for its construction. I would furnish and set up two 500-gallon tanks with 110 Volt pumps in them for each of the two products, unleaded and diesel. These would be adjacent to the construction site. We, would put fresh fuel in each of the tanks. Would this be approved? Security measures would apply.
Answer: this is acceptable per amendment requirements, VA will supply 110 plug connections at buildings in close proximity.
Will 4000 PSI redi mix, locally produced, be sufficient for the tank top replacements?
Answer:
Given that the tanks need to be traffic-rated. We need 6” deep, 4600 PSI (6.5 sack mix), steel (# 4 rebar min.) reinforced with cold bends (around manhole ring) at 1 foot on center.
VA specs can be found at:
2.12 CONCRETE FOUNDATIONS (SECTION 23 10 00 – 30)
0. Concrete ballast foundations for underground tanks and concrete pads for aboveground tanks are specified under Section 03 30 00, CAST-IN-PLACE CONCRETE. Ballast foundations shall be sized for buoyancy of entire tank when empty. Credit for overburden is allowed.
0. RELATED REQUIREMENTS (section 02 65 00 – 1)
1. Excavation Surface Restoration: // Section 32 05 23, CEMENT AND CONCRETE FOR EXTERIOR IMPROVEMENTS // Section 32 12 16, ASPHALT PAVING // Section 32 90 00, PLANTING //.