36C25819B0034-008.pdf

PDF Posted

Attached to
664-19-3-5244-0026 - FY19 NRM PROJECT
Solicitation number
36C25819B0034
Issued by

About this file

36C25819B0034 Attach 06 Fire Alarm.pdf

View the file

Other files

File Type Posted
36C25819C0139-000.docx DOCX document
36C25819B0034-0005000.docx DOCX document
36C25819B0034-0005001.docx DOCX document
36C25819B0034-0005001.docx DOCX document
36C25819B0034-0005000.docx DOCX document
36C25819B0034-0004001.docx DOCX document
36C25819B0034-0004000.docx DOCX document
36C25819B0034-0004001.docx DOCX document
36C25819B0034-0004000.docx DOCX document
36C25819B0034-0003007.pdf PDF
36C25819B0034-0003006.pdf PDF
36C25819B0034-0003004.pdf PDF
36C25819B0034-0003000.docx DOCX document
36C25819B0034-0003010.pdf PDF
36C25819B0034-0003005.pdf PDF
36C25819B0034-0003001.pdf PDF
36C25819B0034-0003003.pdf PDF
36C25819B0034-0003002.pdf PDF
36C25819B0034-0003008.pdf PDF
36C25819B0034-0003009.pdf PDF
36C25819B0034-0003008.pdf PDF
36C25819B0034-0003006.pdf PDF
36C25819B0034-0003000.docx DOCX document
36C25819B0034-0003010.pdf PDF
36C25819B0034-0003001.pdf PDF
36C25819B0034-0003009.pdf PDF
36C25819B0034-0003003.pdf PDF
36C25819B0034-0003004.pdf PDF
36C25819B0034-0003007.pdf PDF
36C25819B0034-0003002.pdf PDF
36C25819B0034-0003005.pdf PDF
36C25819B0034-0002000.docx DOCX document
36C25819B0034-0002001.pdf PDF
36C25819B0034-0002001.pdf PDF
36C25819B0034-0002000.docx DOCX document
36C25819B0034-0001000.docx DOCX document
36C25819B0034-0001000.docx DOCX document
36C25819B0034-005.pdf PDF
36C25819B0034-003.pdf PDF
36C25819B0034-018.docx DOCX document
36C25819B0034-001.docx DOCX document
36C25819B0034-006.pdf PDF
36C25819B0034-015.pdf PDF
36C25819B0034-002.pdf PDF
36C25819B0034-010.pdf PDF
36C25819B0034-011.pdf PDF
36C25819B0034-016.pdf PDF
36C25819B0034-013.pdf PDF
36C25819B0034-007.pdf PDF
36C25819B0034-012.pdf PDF
Show 40 more

Latest 50 of 74 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABBREVIATIONS

AFF = ABOVE FINISH FLOOR

AUX = AUXILIARY

AWG = AMERICAN WIRE GAUGE

CD = CANDELA

CI = CIRCUIT INTEGRITY

DB = DECIBELS

EOL = END OF LINE

ER = EXISTING DEVICE RELOCATED

EX = EXISTING DEVICE TO REMAIN

FACP = FIRE ALARM CONTROL PANEL

FATC = FIRE ALARM TERMINAL CAN

FSD = FIRE SMOKE DAMPER

NAC = NOTIFICATION APPLIANCE

CIRCUIT

NEC = NATIONAL ELECTRICAL CODE

NFPA = NATIONAL FIRE PROTECTION

ASSOCIATION

SLC = SIGNALING LINE CIRCUIT

WP = WEATHER PROOF

GENERAL NOTES

1. THE INSTALLATION OF THE FIRE ALARM SYSTEM SHALL COMPLY WITH NFPA 72, 2016

EDITION, AND NFPA 70 2016EDITION.

2. THE AUDIBILITY OF FIRE ALARM WARNING DEVICES SHALL BE AUDIBLE THROUGH THE

OCCUPANCY WITH A MINIMAL SOUND LEVEL OF 15 dB'S OVER THE AVERAGE AMBIENT

NOISE LEVEL AND 5dB OVER THE MAXIMUM NOISE LEVEL EXCEEDING 60 SECONDS.

3. ALL CONDUIT SIZES SHALL BE IN ACCORDANCE WITH NEC 2016 EDITION.

4. UPON COMPLETION OF THE INSTALLATION OF THE FIRE ALARM SYSTEM, A

SATISFACTORY TEST OF THE ENTIRE SYSTEM SHALL BE PERFORMED IN THE

PRESENCE OF THE ENFORCING AGENCY.

5. ALL CONDUIT PENETRATIONS THROUGH FIRE RATED PARTITIONS SHALL PREVENT THE

PASSAGE OF HEAT, SMOKE AND FIRE GASES. ALL PENETRATIONS SHALL COMPLY

WITH U.L. ASSEMBLY LISTINGS AS REQUIRED.

INSTALLATION NOTES

1. ALL TERMINATIONS MUST BE AT A TERMINAL STRIP.

2. ALL CONDUCTOR TERMINATIONS SHALL BE LABELED.

3. ALL DEVICES MUST HAVE SCREW TERMINALS.

4. PULL ALL CONDUCTORS SPLICE FREE. WHERE SPLICES ARE UNAVOIDABLE PROVIDE

INSULATED BARRIER TYPE TERMINAL STRIPS AT JUNCTION POINTS. THE USE OF WIRE

NUTS, CRIMPED CONNECTORS OR TWISTING OF CONDUCTORS IS PROHIBITED.

5. RUN ALL WIRING TO CONTROL PANELS IN THE VERTICAL OR HORIZONTAL PLANE, MAKE

ALL TURNS AT 90 DEGREE ANGLES, AND TIGHTLY BUNDLE AND WRAP ALL WIRE.

6. IDENTIFY ALL CONDUCTORS INDIVIDUALLY WITH PERMANENT MARKINGS.

7. INSTALL ALL WIRING IN METALLIC CONDUIT.

8. ALL WIRING MUST BE SOLID COPPER, EXCEPT FOR SPEAKER CIRCUITS OR CIRCUITS

REQUIRING SHIELDING.

9. ALL SIGNALING LINE AND INITIATING DEVICE CIRCUITS MUST BE A MINIMUM 16 GAUGE

WIRE.

10.PAINT ALL FIRE ALARM JUNCTION BOXES AND COVERS RED IN UNFINISHED AREAS (i.e., ABOVE CEILINGS, MECHANICAL ROOMS, ETC). IN FINISHED AREAS, CONDUIT AND

JUNCTION BOXES CAN BE PAINTED TO MATCH ROOM FINISH, THE INSIDE COVER OF

THE JUNCTION BOX MUST BE IDENTIFIED AS "FIRE ALARM" AND THE CONDUIT MUST

HAVE PAINTED RED BANDS 3/4 INCH (20 MM) WIDE AT 10 FOOT (3.0M) CENTERS AND AT

EACH SIDE OF A FLOOR, WALL OR CEILING PENETRATION.

11.REMOTE TEST FOR DUCT SMOKE DETECTOR SHALL BE INSTALLED ON CEILING BELOW

DUCT SMOKE DETECTOR.

12. ALL SMOKE DETECTORS SHALL MAINTAIN A 3' SEPARATION FROM ANY AIR REGISTER

OR THE TIP OF ANY CEILING FAN BLADE.

1. INTENT, PURPOSE & REASON:

FIRE ALARM INITIATING AND NOTIFICATION DEVICES TO BE INSTALLED ON EXISTING

FIRE ALARM SYSTEM AS REQUIRED BY CODE. FIRE ALARM NOTIFICATION DEVICES

PROVIDED TO ALERT OCCUPANTS OF FIRE DANGER THROUGHOUT TENANT

IMPROVEMENT.

2. SCOPE:

SYSTEM SHALL PROVIDE FULL OCCUPANT NOTIFICATION THROUGHOUT REMODELED

AREA. REMOVE AND REPLACE EXISTING SMOKE DETECTOR, AND NEW DUCT

DETECTORS FOR NEW AIR HANDLING UNITS

3. TYPE OF FIRE ALARM SYSTEM:

THE EXISTING SYSTEM IS A MANUAL AND AUTOMATIC SYSTEM.

SCOPE OF WORK

CABLE LEGEND

SYMBOL

B AUDIO APPLIANCE CIRCUIT

DESCRIPTION TYPE COLOR

BLK/RED IN RED JACKET

V VISUAL APPLIANCE CIRCUIT ORG/BRN(2) #12 AWG THHN

16/2 FPLR

MANUAL PULL

STATION*

AREA SMOKE

DETECTOR*

FIRE

PROTECTION

SUPERVISORY

SWITCH

FACP POWER

FAIL & LOW

BATTERY

SYSTEM

TROUBLES

EXISTING SEQUENCE OF OPERATIONS

ELEVATOR

MACHINE

ROOM SMOKE

DETECTOR*

* NOTE: THE ACTIVATION OF ANY FIRE ALARM SIGNAL SHALL INITIATE THE FOLLOWING: 1. SHUTDOWN AIR HANDLER ON RESPECTIVE FLOOR

** NOTE: AUDIBLE AND VISUAL SIGNALING DEVICES WILL AUTOMATICALLY ACTIVATE ON THE FLOOR OF ALARM.

FIRE

PROTECTION

WATER FLOW

SWITCH

DUCT SMOKE

DETECTOR

ELEVATOR

SHUNT TRIP

120v POWER

LOSS

LOW WATER

LEVEL IN

WATER TANK

ANNUNCIATE ALARM AT FIRE

CONTROL PANEL

ANNUNCIATE TROUBLE AT

FIRE CONTROL PANEL

ANNUNCIATE SUPERVISORY

AT FIRE CONTROL PANEL

ACTIVATE AUDIBLE/VISUAL

ALARM SIGNAL ON

ASSOCIATED FLOOR**

TO CENTRAL MONITORING

STATION

TRANSMIT TROUBLE SIGNALS

TO CENTRAL MONITORING

STATION

TRANSMIT SUPERVISORY

SIGNALS TO CENTRAL

MONITORING STATION

PRIMARY ELEVATOR RECALL

ALTERNATE ELEVATOR

RECALL

FIREFIGHTER'S SERVICE

VISUAL INDICATOR

SHUNT ELEVATOR POWER

SHUT DOWN ASSOCIATED

AIR HANDLER UNIT

TRANSMIT ALARM SIGNALS

RELEASE DOOR HOLDERS

1st FLOOR

ELEVATOR

LOBBY SMOKE

DETECTOR*

2nd-6TH

FLOOR

ELEVATOR

LOBBY SMOKE

DETECTOR*

DEVICE:

ACTION:

FIRE PUMP

RUNNING

FIRE PUMP

TROUBLE

D SIGNALING LINE CIRCUIT BLK/RED IN RED JACKET16/2 FPLR

NPS

QTY SYMBOL DEVICE DESCRIPTION MODEL NUMBER MANUFACTURER

FIRE ALARM LIST OF MATERIALS

BACKBOXES

NOTIFICATION APPLIANCE CIRCUIT

POWER SUPPLY

N/ABPS6A

GENESIS MULTI-CANDELA CEILING SPEAKER STROBE

(# = CANDELA) GCHFWF-S2VMC

EDWARDS

EDWARDS

4 SQUARE W/

EXTENSION RING

ER

4 SQUARE W/

3o EXTENSION RING

EXISTING SMOKE DETECTOR

WITH STANDARD BASE

SIGA-PS

SIGA-SB EDWARDS1

FACP

CEILING

CONDUIT

AUDIO/VISUAL DEVICE

@48" O.C. OF

OPERATING

HANDLE A.F.F.

BOTTOM OF LENS

@+80"-93" A.F.F.

72"

FLOOR/ ROOF ABOVE

INTERIOR

INTERSTITIAL SPACE

PULL STATION

FLUSH MOUNTING AUDIO/VISUAL DEVICE TO

CEILING USING A STANDARD 4"

DEEP SQUARE BOX W/EXTENSION RING

12" MAXTOP OF DETECTOR

ACCEPTABLE HERE

FINISHED

FLOOR

SCALE: NONE

FIRE ALARM MOUNTING HEIGHT

STUB CONDUIT INTO ATTIC SPACE

FOR OPEN WIRE APPLICATIONS

FIRE

F I R E

CONDUIT

CEILING

TOP OF AUDIBLE ONLY DEVICE TO BE

GREATER THAN 90" A.F.F. AND NO CLOSER

THAN 6" FROM CEILING

INTERSTITIAL SPACE

F I R E

NPS

72"

DETECTOR SHALL BE MOUNTED A DISTANCE

OF AT LEAST 3' FROM ANY MECHANICAL

DIFFUSER AND 12" FROM ANY SPRINKLER HEAD

NOTE: ALL CABLE IS IN 3/4" EMT UNLESS OTHERWISE NOTED.

GENESIS MULTI-CANDELA CEILING STROBE

(# = CANDELA) GCF-VM EDWARDS

4 SQUARE W/

EXTENSION RING

ADDRESSABLE DUCT SMOKE DETECTOR HOUSING

WITH ADDRESSABLE SMOKE DETECTOR

N/ASIGA-DH

SIGA-PS

EDWARDS

2 HIGH POWERED CONTROL RELAY SIGA-CRH EDWARDS

CR

4 SQUARE W/

EXTENSION RING

EXISTING DEVICE TO BE REMOVED AND RELOCATEDER

EXISTING DEVICE TO BE REMAINEX

M

N

N.25

N.5

CR

CR

J

2D

2D

2D

EX

AC

EXISTING

AC-58

SLC POINT OF

CONNECTION

AC

SUPPLY

RETURN

1/4W 15cd

N1-02 ER

1/4W 95cd

N1-03

1/4W 30cd

N1-04

15cd

N1-05ER

NIC

2B,2V

2B,2V

2V

N

M

N.25

N.5

1/4W 15cd

N1-06

EOL-N1

ER

1/4W 75cd

N1-01

ER

J

B,V

B,V B,V

EXISTING POINT OF

CONNECTION

ER

1/4W 15cd

N1-02

ER

1/4W 95cd

N1-03

1/4W 30cd

N1-04

15cd

N1-05

FROM NEAREST

INITIATING DEVICE

FROM NEAREST

INITIATING DEVICE

CRCR

EX

AC

AC

2D

DD

1/4W 15cd

N1-06

EOL-N1

ER

1/4W 75cd

N1-01

ER

NPS

EX

3.0 Amps available at

Amps available overall.

each output NAC. 6.5

Battery

IN

Trouble COM

NC

Sense 2

OUT

COM

NO

IN

Sense 1 COM

OUT

NOTE: CUT JUMPER

JP4 IF USING LESS

THAN 10AH BATTERIES

JP4

AUX

NAC #1 (OUT)

NAC #3 (OUT)

NAC #2 (OUT)

NAC #4 (OUT)

SPEAKER

STROBE SPEAKER

NAC CIRCUIT 1

EOL 15K

BATTERIES

WIRED IN SERIES

12V 7AH

SEALED

LEAD-ACID

BATTERY

12V 7AH

SEALED

LEAD-ACID

BATTERY

EXISTING120vac 20 AMP

DEDICATED CIRCUIT BREAKER.

IDENTIFIED "FIRE ALARM"

BREAKER SHALL BE LOCK ON

TYPE AND WIRING TO BE

PROVIDED BY ELECTRICAL

CONTRACTOR.

FROM EXISTING

AUDIO DEVICE

NPS# 1

FROM PREVIOUS

EXISTING DEVICE

STROBE

SENSE TRIGGER FROM

EXISTING NPS

SPARE

SPARE

TO DDC

STATUS

(BY OTHERS)

SD-TRK

REMOTE TEST

STATION

N C

N C

C

N O

C

N O

SIGA-CRH

HIGH POWER

RELAY

MODULE-+ - +

SIGA-SB

STANDARD BASE

TO SHUTDOWN

AIR HANDLING

UNIT

TO NEXT

EXISTING DEVICE

AUDIO CIRCUIT

EOL 15K

FA-001
FA-001
Layout1
FA-101
FA-101
Layout1
FA-501
FA-501
Layout1