Attachment A Device Inventory.xlsx
XLSX spreadsheet 14 KB Posted
- Solicitation number
- 36C25722Q0693
About this file
This document includes an attachment with inventory details for fire alarm and sprinkler systems across multiple campuses, along with a related federal contract opportunity solicitation. The solicitation is a request for quote from the Department of Veterans Affairs to provide comprehensive life safety fire alarm system and sprinkler suppression system repair, maintenance, inspection, testing, and modification/installation services for buildings on the Dallas, Bonham, Garland, and Grand Prairie campuses as well as the Veteran Resource Center and TR houses in the North Texas Veterans Health Care System. Interested Service-Disabled Veteran Owned Small Businesses must be verified on the Vendor Information Pages database and registered in the System for Award Management to be eligible for award. Questions are due by July 28, 2022 and offers must be submitted directly to the identified contracting specialist by the time specified in the solicitation. The period of performance and pricing terms are not stated.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF30 36C25722Q0693 0002.pdf | ||
| 36C25722Q0693 0002_1.docx | DOCX document | |
| Bonham Inspection Bldg 1.pdf | ||
| Garland Inspection.pdf | ||
| Grand Prairie Inspection.pdf | ||
| Dallas Inspection Bldg 1.pdf | ||
| SF30 36C25722Q0693 0001.pdf | ||
| 36C25722Q0693 0001_1.docx | DOCX document | |
| RFQ 36C25722Q0693.docx | DOCX document | |
| Bonham WD 2015-5273.pdf | ||
| Dallas _ Garland WD 2015-5227.pdf | ||
| Grand Prairie WD 2015-5231.pdf | ||
| 36C25722Q0693_1.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| North Dallas Campus | Pump Runs | Tamper Switches / Control Valve | Manual Pull Station | Smoke Detectors | Heat Detectors | Duct Detectors | Audio / Visual | Strobes | Mass Strobes | Speakers | Speaker Strobe | HVAC Shutdowns | Beam Detectors | Water Motor Gong | Floors | Risers |
| Bldg. 1 | 1 | 28 | 23 | 78 | 20 | 8 | 2 | 32 | 153 | 19 | 119 | 6 | 6 | 2 | ||
| Bldg. 2 | 2 | 100 | 112 | 394 | 86 | 64 | 100 | 219 | 780 | 168 | 587 | 30 | 9 & 1 Basement & 1 sub-basement | 5 | ||
| Bldg. 2J | 1 | 71 | 139 | 406 | 65 | 56 | 95 | 1194 | 400 | 136 | 625 | 51 | 6 | 5 & 1 Basement & 1 Sub-basement | 7 | |
| Bldg. 3, 43 | 1 | 30 | 60 | 65 | 20 | 18 | 56 | 102 | 250 | 74 | 185 | 3 | 3 | 1 | ||
| Outer Bldgs. 5,6,8,9, TT46, 47, 48, 49, 51, 52, 75 | 25 | 100 | 147 | 100 | 99 | 195 | 245 | 50 | 72 | 55 | 1 floor per Building | 1 | ||||
| Bldg. 44 | 1 | 4 | 4 | 10 | 3 | 4 | 10 | 15 | 2 | 2 | 15 | 1 | 1 | 1 | ||
| Bldg 45 | 1 | 12 | 5 | 20 | 3 | 4 | 2 | 15 | 2 | 5 | 10 | 2 | 1 | 1 | ||
| Bldg 60 | 1 | 13 | 26 | 171 | 6 | 10 | 2 | 91 | 91 | 49 | 2 | 3 | 1 & 2 Pen House | 1 | ||
| Bldg 70 | 1 | 8 | 10 | 3 | 1 | 6 | 23 | 8 | 30 | 5 | 5 | 6 | 1 | 1 | ||
| Bldg 74 | 1 | 12 | 27 | 65 | 5 | 9 | 1 | 26 | 115 | 13 | 96 | 6 | 1 & 1 Basement | 1 | ||
| Bldg 79 | 2 | 10 | 52 | 3 | 2 | 39 | 11 | 24 | 5 | 6 | 2 | 2 | 1 | |||
| Bldg 87 | 9 | 9 | 1 | 2 | 3 | 12 | 4 | 7 | 1 | 2 | 3 | 1 | 1 | |||
| TR Houses(4) | 4 | 16 | 8 | 16 | 4 | 4 | 16 | 16 | 4 | 4 | 4 | 4 | 1 floor per house | 1 per house | ||
| Herzog Complex | 4 | 150 | 75 | 120 | 60 | 20 | 58 | 105 | 202 | 60 | 195 | 10 | Main building has 2 floors and the other 2 buildings has 1 floor | 3 | ||
| Total | 18 | 480 | 608 | 1548 | 378 | 307 | 416 | 2033 | 2305 | 591 | 1923 | 182 | 6 | 54 | 30 | |
| Dallas Campus Hydrants | ||||||||||||||||
| 45 | ||||||||||||||||
| PIV | ||||||||||||||||
| 13 | ||||||||||||||||
| Bonham Capmus | Pump Runs | Tamper Switches / Control Valve | Manual Pull Station | Smoke Detectors | Heat Detectors | Duct Detectors | Audio / Visual | Strobes | Mass Strobes | Speakers | Speaker Strobe | HVAC Shutdowns | Beam Detectors | Water Motor Gong | Floors | Risers |
| Bldg 1 | 1 | 21 | 34 | 116 | 10 | 5 | 10 | 35 | 95 | 16 | 65 | 3 | 5 | 4 | ||
| Bldg 2 | 19 | 24 | 94 | 15 | 7 | 12 | 45 | 85 | 18 | 70 | 2 | 4 | 3 | |||
| Bldg 3 | 10 | 18 | 27 | 6 | 9 | 15 | 10 | 35 | 10 | 16 | 9 | 2 | 1 | |||
| Bldg 4 | 5 | 4 | 8 | 4 | 3 | 12 | 10 | 25 | 12 | 15 | 3 | 2 | 1 | |||
| Bldg 8 | 4 | 4 | 10 | 3 | 2 | 10 | 10 | 15 | 8 | 12 | 2 | 1 | 1 | |||
| Bldg 9 | 7 | 4 | 5 | 5 | 2 | 6 | 10 | 15 | 12 | 15 | 4 | 1 | 1 | |||
| Bldg 10 | 10 | 4 | 10 | 3 | 5 | 15 | 10 | 10 | 10 | 16 | 2 | 1 | 1 | |||
| Bldg 11 | 12 | 33 | 18 | 6 | 10 | 14 | 10 | 15 | 8 | 20 | 5 | 1 | 1 | |||
| Bldg 12 | 5 | 6 | 10 | 4 | 3 | 10 | 10 | 12 | 6 | 17 | 2 | 2 | 1 | |||
| Bldg 24 | 12 | 40 | 268 | 10 | 15 | 20 | 15 | 75 | 18 | 55 | 4 | 2 | 1 | |||
| Bldg 29 | 10 | 27 | 56 | 2 | 6 | 20 | 15 | 65 | 16 | 49 | 4 | 1 | 1 | |||
| Total | 22, Basements is not included in the count, need field vefication | 16 | ||||||||||||||
| Bonham Hydrants | ||||||||||||||||
| 14 | ||||||||||||||||
| PIV | ||||||||||||||||
| 6 | ||||||||||||||||
| Garland Campus | 1 | 42 | 91 | 720 | 51 | 148 | 22 | 778 | 42 | 105 | 393 | 3 | 1 | Floors (5) | Risers (4) | |
| Garland Hydrants | ||||||||||||||||
| 10 | ||||||||||||||||
| PIV | ||||||||||||||||
| 0 | ||||||||||||||||
| Grand Prairie Campus | 1 | 7 | 10 | 15 | 3 | 5 | 25 | 15 | 4 | 6 | 4 | 1 | Floors (1) | Risers (2) | ||
| Grand Prairie Hydrants | ||||||||||||||||
| 4 | ||||||||||||||||
| PIV | ||||||||||||||||
| 0 |