36C25625Q1429 0001.docx
DOCX document 19 KB Posted
- Solicitation number
- 36C25625Q1429
About this file
This document is a combined synopsis/solicitation for a commercial services contract issued by the Department of Veterans Affairs Veterans Health Administration. The solicitation (36C25625Q1429) seeks a service-disabled veteran-owned small business to performGenerator Preventive Maintenance, Repair, and Load Bank Testing at the Overton Brooks VA Hospital in Shreveport, Louisiana. The procurement is a Lowest Priced Technically Acceptable (LPTA) brand-name solicitation for a firm-fixed price contract with a base year and four option years.
Key details include a requirement for the contractor to restore equipment within one week, provide portable emergency generators if multiple units fail, and maintain emergency power capacity. The solicitation is set aside for service-disabled veteran-owned small businesses with a North American Industry Classification System (NAICS) code of 811310 and a $14M size standard. Important dates include a question submission deadline of August 29, 2025, and quote submission deadline of September 2, 2025 (extended to September 8, 2025), with quotes to be submitted electronically to Contract Specialist Le Kisha Douglas.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| WD 2015-5191.pdf | ||
| 36C25625Q1429_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment to a Previous Combined Solicitation
Amendment to a Previous Combined Solicitation
| SUBJECT* |
| Generator PM/Repair and load bank testing Questions and Extension |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 77056-5643 |
| SOLICITATION NUMBER* |
| 36C25625Q1429 |
| RESPONSE DATE/TIME/ZONE |
| 09-08-2025 10:00 CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| J061 |
| NAICS CODE* |
| 811310 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 16 5075 Westheimer Road, Suite 750
Houston TX 77056-5643
POINT OF CONTACT*
Contracting Officer Le Kisha Douglas LeKisha.Douglas@va.gov
PLACE OF PERFORMANCE
| ADDRESS |
| Overton Brooks VA Hospital |
510 E. Stoner Avenue
Shreveport, LA
71101
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
The purpose of this amendment is to:
1) Extend the closing date of solicitation 36C25625Q1429 from to 09/08/2025 at 10:00 am CST.
2) Post all questions and government responses received for this requirement:
a. Will there be a site visit?
i. No, there will not be a site visit
b. What cable length is needed to connect the load bank to the generator?
i. In the past the longest distance for load bank test was 100 ft
c. Are grounding provisions in place for the load bank?
i. There are lugs for the ground wires
d. Is there enough space for the load bank and ventilation clearance?
i. There is ample space for the load bank and ventilation
e. On page 25 of the Synopsis/Solicitation:
The Contractor shall restore the equipment to full performance within one week of the originating call and/or have the capability to provide a portable emergency generator of equal capacity if the facility has one or two inoperable generators. Charges to the VA for generator rental and tie ins shall originate only upon prior approval being granted by the Contracting Officer as an additional cost to the VA. Use of overtime emergency hours as listed in this PWS may be used toward this item should the VA have not yet exhausted the aggregate for the year. Should the facility experience a failure of three or more generators at one time, the Contractor shall provide portable emergency generators (rental, tie ins and fuel) of equal, total capacity of the units, minus two, at no cost to the VA to maintain an emergency power capacity of 11MW (equivalent of five 2.2 MW units). This shall occur if the inoperability of the units is due to poor maintenance, lead time of replacement parts as part of maintenance program, system failures due to normal wear and tear.
i. Without knowing the current state of repair, or ongoing maintenance schedule, is it the VA’s intent for the contractor to take the full risk and responsibility for providing free-of-charge emergency power if the existing generators are already in a state of disrepair?
1. It is our intent for the contractor to be held accountable if the generators are down due to contractors’ negligence of inadequately performing the preventative maintenance. All generators listed in the SOW are tested monthly according to Joint Commission Standards and have been properly maintained up to this point. All
ii. Will the VA allow the contractor to include a rental fee schedule as part of this proposal, broken out on a per-generator basis?
1. The contract is for maintenance and annual testing. Any emergency rental (unassociated with #2 per the PWS, below, that we would need to cover would likely need to be a new emergency contract for equipment rental
2. This shall occur if the inoperability of the (3 or more) units is due to poor maintenance, lead time of replacement parts as part of maintenance program, system failures due to normal wear and tear
iii. Does the phrase cited above, “if the inoperability of the units is due to poor maintenance” include existing units, if poorly maintained currently?
1. All generators listed in the SOW are tested monthly, in accordance with Joint Commission Standards and have been properly maintained up to this point