P09 FD issues LS Drawing Bldg 9 6-10-2024.pdf
PDF 1 MB Posted
- Solicitation number
- 36C25624R0115
About this file
This document contains a pre-solicitation notice for a federal contract opportunity issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The opportunity is for a project to Replace Fire Doors in Buildings 7 and 9 at the Alexandria VA Health Care System in Pineville, Louisiana. The applicable NAICS code is 238290 Other Building Equipment Contractors, and the estimated construction cost range is between $25,000 and $100,000. The contract will be awarded using the Lowest Price Technically Acceptable source selection process, and a bid bond will be required. Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) certified through the SBA are eligible to submit proposals. The official solicitation will be issued on or around 07/26/2024 on SAM.gov, and a site visit is planned with details to be provided with the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| P09 SOW Fire Doors for Building 7 and 9 Joint commission requirement.docx | DOCX document | |
| 36C25624R0115.docx | DOCX document | |
| P09 FD issues LS Drawing Bldg 7 6-10-2024.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E
E
1B.1
SP
FH R
SP
FH R
CHK. BY:
DATE:
SCALE:
DWG. BY:
DWG. No.:
LOCATION:
8/31/2023
BH JC
PINEVILLE LA
TITLE:
No. REVISIONS DATE
US DEPT of VETERANS AFFAIRS
ALEXANDRIA VA MEDICAL
Building 9 2495 Shreveport Highway
FLOOR 1
LIFE SAFETY
DRAWINGS
FIRST FLOOR PLAN
LIFE SAFETY LEGEND
Hazardous Area (Note 2)
Exterior Exit
2 Hour Fire Barrier
1 Hour Fire/Smoke Barrier
Smoke Barrier
Exit Stairwell
Area Under Construction
Exit Passageway
Suite (Color May Vary)
Trash/Linen Chute
Exit Access Corridor
2 Hour Fire/Smoke Barrier
1 Hour Fire Barrier
Exit Travel Distance
Smoke Barrier Travel Distance
Suite Travel Distance
All Hazard Area
Note 2: All hazardous areas in existing occupancies are protected by smoke tight partitions and self closing doors unless otherwise labeled.
General Note:
Corridor walls in fully sprinklered smoke compartments shall be permitted to terminate at the ceiling where the ceiling is constructed to limit the transfer of smoke
Smoke Tight Partition
Area Not Surveyed
SP
FH R
Fire Door was modified needs to be replaced
E
SP
FH R
SP
FH R
SP
FH R
SP
FH R
SP
FH R
SP
FH R
2.1
2.2
CHK. BY:
DATE:
SCALE:
DWG. BY:
DWG. No.:
LOCATION:
8/31/2023
BH JC
PINEVILLE LA
TITLE:
No. REVISIONS DATE
US DEPT of VETERANS AFFAIRS
ALEXANDRIA VA MEDICAL
Building 9 2495 Shreveport Highway
FLOOR 2
LIFE SAFETY
DRAWINGS
SECOND FLOOR PLAN
LIFE SAFETY LEGEND
Hazardous Area (Note 2)
Exterior Exit
2 Hour Fire Barrier
1 Hour Fire/Smoke Barrier
Smoke Barrier
Exit Stairwell
Area Under Construction
Exit Passageway
Suite (Color May Vary)
Trash/Linen Chute
Exit Access Corridor
2 Hour Fire/Smoke Barrier
1 Hour Fire Barrier
Exit Travel Distance
Smoke Barrier Travel Distance
Suite Travel Distance
All Hazard Area
Note 2: All hazardous areas in existing occupancies are protected by smoke tight partitions and self closing doors unless otherwise labeled.
General Note:
Corridor walls in fully sprinklered smoke compartments shall be permitted to terminate at the ceiling where the ceiling is constructed to limit the transfer of smoke
Smoke Tight Partition
Area Not Surveyed
SP
E
SP
FH R
SP
FH R
SP
FH R
SP
FH R
3.1
3.2
SP
FH R
CHK. BY:
DATE:
SCALE:
DWG. BY:
DWG. No.:
LOCATION:
8/31/2023
BH JC
PINEVILLE LA
TITLE:
No. REVISIONS DATE
US DEPT of VETERANS AFFAIRS
ALEXANDRIA VA MEDICAL
Building 9 2495 Shreveport Highway
FLOOR 3
LIFE SAFETY
DRAWINGS
THIRD FLOOR PLAN
LIFE SAFETY LEGEND
Hazardous Area (Note 2)
Exterior Exit
2 Hour Fire Barrier
1 Hour Fire/Smoke Barrier
Smoke Barrier
Exit Stairwell
Area Under Construction
Exit Passageway
Suite (Color May Vary)
Trash/Linen Chute
Exit Access Corridor
2 Hour Fire/Smoke Barrier
1 Hour Fire Barrier
Exit Travel Distance
Smoke Barrier Travel Distance
Suite Travel Distance
All Hazard Area
Note 2: All hazardous areas in existing occupancies are protected by smoke tight partitions and self closing doors unless otherwise labeled.
General Note:
Corridor walls in fully sprinklered smoke compartments shall be permitted to terminate at the ceiling where the ceiling is constructed to limit the transfer of smoke
Smoke Tight Partition
Area Not Surveyed
Fire Door has hole and been modified need to be replaced.
PB.1
CHK. BY:
DATE:
SCALE:
DWG. BY:
DWG. No.:
LOCATION:
8/31/2023
BH JC
PINEVILLE LA
TITLE:
No. REVISIONS DATE
US DEPT of VETERANS AFFAIRS
ALEXANDRIA VA MEDICAL
Building 9 2495 Shreveport Highway
PENTHOUSE
LIFE SAFETY
DRAWINGS
PENTHOUSE FLOOR PLAN
LIFE SAFETY LEGEND
Hazardous Area (Note 2)
Exterior Exit
2 Hour Fire Barrier
1 Hour Fire/Smoke Barrier
Smoke Barrier
Exit Stairwell
Area Under Construction
Exit Passageway
Suite (Color May Vary)
Trash/Linen Chute
Exit Access Corridor
2 Hour Fire/Smoke Barrier
1 Hour Fire Barrier
Exit Travel Distance
Smoke Barrier Travel Distance
Suite Travel Distance
All Hazard Area
Note 2: All hazardous areas in existing occupancies are protected by smoke tight partitions and self closing doors unless otherwise labeled.
General Note:
Corridor walls in fully sprinklered smoke compartments shall be permitted to terminate at the ceiling where the ceiling is constructed to limit the transfer of smoke
Smoke Tight Partition
Area Not Surveyed