36C25619R0111-0001006.pdf
PDF 678 KB Posted
- Solicitation number
- 36C25619R0111
About this file
36C25619R0111 0001 JLM 5D Fire Protection.pdf
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLOOR PLAN - 5D
PLUMBING
PL101
1/8" = 1'-0"
FLOOR PLAN 5D - PLUMBING
NTS1 KEY PLAN - 5th FLOOR
PL401
FD
FD
E
F
H
J
L
K
131298765
MM
UTIL, SOILED
5D-168
UTIL, SUPPLY,
STERILE
5D-169
EXAM/TREAT
5D-134
EXAM/TREAT
5D-132
UTIL, SUPPLY,
STERILE
5D-133
PRIVATE TLT
5D-167
PRIVATE ROOM
5D-166 HEMO-DIALYSIS
5D-163
ADA TLT
5D-164
ADA TLT
5D-161
PATIENT
LOCKERS
5D-162
MED PREP
5D-144A
EQUIP STG
5D-153
CLEAN LINEN
5D-171
NURSE
5D-165
WC/STR STG
5D-170
EXAM/TREAT
5D-135
EXAM/TREAT
5D-131
ELEC
5D-137
ST
AI
R
NURSE
5D-136
HOME DIALYSIS
RN's 5D-127
UTIL, SUPPLY,
STERILE
5D-128
ADA TLT
5D-130
UTIL, SOILED
5D-129
CHIEF NURSE
5D-145
NOURISHMENT
5D-150
HAC
5D-149
DI
AL
YS
AT
E
PR
EP
5D
-1
ADA TLT
5D-157
STORAGE
5D-126
BIOMEDICAL
ENGINEERING
5D-138
CHASE
PORTABLE
DIALYSIS EQUIP
PROCESSING
5D-143
EQUIP SOIL
5D-140
EQUIP CLEAN
5D-139
TEL EQ
5D-147
SIG EQ
5D-146
SHAFT
WATER
TREATMENT
ROOM
5D-141
EXISTING
PNEUMATIC
TUBE DELIVERY
SYSTEM
CORR.
5D-122
CRASH CART
5D-152
HEMO PREP
5D-151
WC/STR STG
5D-158
CORRIDOR
5D-142
CLASSROOM
5D-125
STAFF TLT
5D-120
STAFF TLT
5D-119
STAFF LOCKERS
5D-118
STAFF LOUNGE
5D-117
FELLOWS
5D-115
ADMIN
5D-114
UTIL, SUPPLY,
STERILE
5D-116 PHYSICIAN
5D-110
PHYSICIAN
5D-109
ASST. CHIEF
5D-108
CLERK
5D-123
HOME PREP
5D-121
NURSE
5D-160
NURSE
5D-159
HEMO-DIALYSIS
5D-155
CORRIDOR
5D-144
STORAGE
5D-111
MEN
5A-115
WOMEN
5A-114
PHYSICIAN
5D-112
PHYSICIAN
SHARED OFFICE
5D-106
SCHEDULING
CLERK
5A-113
CORRIDOR
5D-113
CORRIDOR
5D-107
CORRIDOR
C56-JLM
CORRIDOR
C58-JLM
MEDICINE PREPARATION
5A116-JLM
DUMB
WAITERCHASE
ELECTRIC
5A110-JLM
SI
G
NA
L
5A
1-
JL
M
TE
LE
E Q
UI
P
5A
2-
JL
M
SERVICE ELEV
C57-JLM
NTRNTN & FOOD
SERVICE
5A109-JLM
CHASECHASE
STAIR
ELEV
S-3
CHIEF OFFICE
5D-105
WAITING
5A-117
UTIL, SUPPLY,
STERILE
5D-156
STORAGE
5A-113A
CLERK
5D-154
G
TYP.
AE105
6E
AE103
6E
AE104
5E
NEW UNRATED PARTITION
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
SMOKE BARRIER
EXISTING PARTITION TO BE REMOVED
EXISTING UNRATED PARTITION
CONTRACT LIMITS
AREA NOT IN CONTRACT
1 HOUR TEMPORARY PARTITION
(COORD w/ ASB. ABATEMENT)
DESIGN NO. U419, ANSI/UL 263
DEDUCTIVE ALTERNATE #2: ELIMINATE
THE RENOVATION OF APPROXIMATELY
3,506 SQ. FT. OF OFFICES AND
ADMINISTRATION AREA.
DEDUCTIVE ALTERNATE #3: ELIMINATE
THE RENOVATION OF APPROXIMATELY
568 SQ. FT. OF EXAM ROOMS,
TREATMENT ROOMS AND CORRIDOR.
DEDUCTIVE ALTERNATE #1: ELIMINATE
THE RENOVATION OF APPROXIMATELY
717 SQ. FT. OF WAITING ROOM AND
TOILET ROOMS.
DEDUCTIVE ALTERNATE #4: ELIMINATE
THE RENOVATION OF APPROXIMATELY
315 SQ. FT. OF SIX HEADWALLS AND
TREATMENT STATIONS.
BASE BID: WORK INCLUDES RENOVATION OF APPROXIMATELY
14,700 SQ. FT. AND ALL WORK INCLUDED IN DRAWINGS AND
SPECIFICATIONS.
DESIGN/BUILD
FULLY SPRINKLERED
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot 6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot
VA FORM 08-6231
E
D
C
B
A
BES DESIGN/BUILD, LLC
766 Middle St, Fairhope, AL 36532
Phone: 251.990.5778 Fax: 251.990.3716 of
23456
123456
F
E
D
C
B
A
CENTRAL ARKANSAS
VETERANS AFFAIRS
HEALTHCARE
SYSTEM
10/30/2014 10:11:29 PM
IMPROVE 5D DIALYSIS
FUNCTIONAL DEFICIENCIES
FLOOR PLAN - NEW CONSTRUCTION
4300 WEST 7TH STREET
LITTLE ROCK, AR 72205
598-13-109
JLM
AE101
2014.10.31 NB ROWApprover
CONSTRUCTION DOCUMENTS
1/8" = 1'-0"6E FLOOR PLAN - NEW CONSTRUCTION
PLAN
NORTH
A E
BC
D
KEY PLAN
PROJECT AREA
5D F.F.E.: 464'-1 3/4"
PROJECT AREA: 14,700 S.F.
SCALE: 1/8" = 1'-0"
0 4' 8' 16'
GENERAL FLOOR PLAN NOTES
1 DEPICTION OF EXISTING CONDITIONS BASED ON
OWNER-FURNISHED DOCUMENTS AND LIMITED FIELD
OBSERVATIONS. EXISTING ELEMENTS AND CONDITIONS
CONCEALED BY IN-PLACE EQUIPMENT AND FINISHES WERE NOT
OBSERVED OR INVESTIGATED. ONCE CUTTING AND SELECTIVE
DEMOLITION WORK IS COMPLETE, REPORT ANY CONFLICTS TO
DESIGNER. THE CONTRACTOR SHALL MAKE ADJUSTMENTS
AND/OR ALTERATIONS AS NECESSARY TO INSTALL COMPLETE
AND OPERABLE SYSTEMS IN ACCORDANCE WITH THE CODES
HAVING JURISDICTION AT NO ADDITIONAL COST TO THE
GOVERNMENT.
2 REFER TO SHEET GI003 STANDARD ABBREVIATIONS FOR
EQUIPMENT PROCUREMENT AND INSTALLATION RESPONSIBILITY
DESIGNATIONS.
3 UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO FINISHED
FACE OF PARTITIONS (EXCLUDING APPLIED FINISHES SUCH AS
TILE) AND TO COLUMN CENTER LINES.
4 CONTRACTOR SHALL PROVIDE ALL BLOCKING REQUIRED TO
ANCHOR ALL WALL AND CLG MOUNTED ITEMS, INCLUDING BUT
NOT LIMITED TO TOILET ROOM ACCESSORIES, MILLWORK,
CASEWORK, HANDRAILS, DOOR STOPS ETC.
5 IN NEW GYPSUM WALL BOARD PARTITIONS, PROVIDE CONTROL
JOINTS AT 30'-0" O.C. MAX.
6 REFER TO SHEET GI004 FOR PARTITION SCHEDULE AND
GENERAL PARTITION TYPE NOTES.
7 REFER TO AE400 SERIES FOR ENLARGED FLOOR PLAN VIEWS
INCLUDING MEDICAL EQUIPMENT.
8 REFER TO FIRE PROTECTION LIFE SAFETY DRAWINGS (GI100
SERIES) FOR SCOPE OF RATED WALL CONSTRUCTION, SMOKE
PARTITIONS, EGRESS AND EXIT DISCHARGE INFORMATION.
9 PARTITION TYPES AS NOTED BY THE SYMBOL CONTINUE
BETWEEN ROOM/SPACE CORNERS OR ANY INTERSECTING
PARTITION.
10 DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL
PLANES CONTINUE UNBROKEN WITHIN/ACROSS ROOMS AND/OR
SPACES.
11 REFER TO AE600 SERIES DRAWINGS FOR DOOR & RELITE
SCHEDULES.
12 DISTANCE FROM HINGE SIDE OF DOOR TO INTERSECTING STUD
WALL SHALL BE 4” UNLESS NOTED OR DETAILED OTHERWISE
(MEASURED FROM OUTSIDE OF FRAME)
13 CONTRACTOR SHALL VERIFY ALL DIMENSIONS NOTED AS
“CLEAR” OR “MIN". DIMENSIONS NOTED AS “HOLD” ARE CRITICAL
TO COORDINATE OTHER WORK (E.G. CEILING GRIDS, LIGHTING,
FINISHES).
14 CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO
INITIATING CONSTRUCTION AND REPORT DISCREPANCIES TO
ARCHITECT PRIOR TO COMMENCING WORK.
15 ALL PENETRATIONS THROUGH RATED FLOOR/CEILING
ASSEMBLIES AND THROUGH FIRE RATED WALL AND SMOKE
BARRIER ASSEMBLIES - THOSE CREATED BY REMOVAL OF
DEMOLISHED ITEMS UNDER THIS CONTRACT AND THOSE
DISCOVERED DURING CONSTRUCTION UNDER THIS CONTRACT
AS A RESULT OF PREVIOUS WORK AND THOSE CREATED BY NEW
WORK UNDER THIS CONTRACT - MUST BE SEALED AS PART OF
THIS CONTRACT. ALL RATED SEPARATIONS MUST MEET
CURRENT CODE REQUIREMENTS WITH APPROVED UL
ASSEMBLIES. SEE PENETRATION DETAILS ON SHEET AE101 FOR
WORK BY GENERAL CONTRACTOR. SEE MEPFP SHEETS FOR
PENETRATION FIRE STOPPING REQUIREMENTS FOR MEPFP
CONTRACTORS.
PARTITION LEGEND
PLAN
NORTH
A E
BC
D
KEY PLAN
PROJECT AREA
5D F.F.E.: 464'-1 3/4"
PROJECT AREA: 14,700 S.F.
DEDUCTIVE ALTERNATES LEGEND
DETAIL UL-1497
rwhiteside row ark 10-31-14
File details come from the government source that posted it.