36C25618U0323-0002004.pdf
PDF 5 MB Posted
- Attached to
- Services Commissioning for HVAC Digital Controls Federal contract opportunity
- Solicitation number
- 36C25618U0323
About this file
36C25618U0323 0002 Drawings - Building 7 Part 3 (M7-3XX Series).pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| -15380.docx | DOCX document | |
| 36C25618U0323-0002003.pdf | ||
| 36C25618U0323-0002008.pdf | ||
| 36C25618U0323-0002007.pdf | ||
| 36C25618U0323-0002005.pdf | ||
| 36C25618U0323-0002006.pdf | ||
| 36C25618U0323-0002012.pdf | ||
| 36C25618U0323-0002000.docx | DOCX document | |
| 36C25618U0323-0002013.pdf | ||
| 36C25618U0323-0002010.pdf | ||
| 36C25618U0323-0002002.pdf | ||
| 36C25618U0323-0002011.pdf | ||
| 36C25618U0323-0002009.pdf | ||
| 36C25618U0323-0002014.pdf | ||
| 36C25618U0323-0002001.docx | DOCX document | |
| 36C25618U0323-0001000.docx | DOCX document | |
| 36C25618U0323-002.pdf | ||
| 36C25618U0323-001.docx | DOCX document | |
| 36C25618U0323-000.docx | DOCX document |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F E
D C
B G
Alexandria, Louisiana
A&E Design - Upgrade Energy Management Control Systems
October 30, 2013
VA256-12-C-0253
VETERANS HEALTH CARE
SYSTEM
Alexandria, LA
A
U.S. Department of Veterans Affairs
ENLARGED PIPE BASEMENT
FLOOR PLAN - MECHANICAL
7 EXPANSION WLP NMT
M7-300
NOTES;
1. THESE DRAWINGS ARE THE DESIGN DRAWINGS FOR THE BUILDING 7 EXPANSION CURRENTLY
ON GOING AND ARE FOR REFERENCE ONLY.
2. ALL EQUIPMENT IN THIS PROJECT WILL BE CONTROLLED BY THE CAMPUS SIEMENS SYSTEM.
MIGRATE ALL CONTROLS TO NEW SERVER.
3. BID ADDITIVE ITEMS A, D, & E WERE NOT SELECTED.
10-30-13
D C
B G
Alexandria, Louisiana
A&E Design - Upgrade Energy Management Control Systems
October 30, 2013
VA256-12-C-0253
VETERANS HEALTH CARE
SYSTEM
Alexandria, LA
A
U.S. Department of Veterans Affairs
1ST FLOOR PLAN - SOUTH WING -
MECHANICAL
7 EXPANSION WLP NMT
M7-301a
M A
T C
H L
IN
E
S E
E S
H E
E T
M -3 b
F O
R C
O N
T
IN
U T
A T
IO
N
M A
T C
H L
IN
E
S E
E S
H E
E T
M -3 b
F O
R C
O N
T
IN
U T
A T
IO
N
NOTES;
1. THESE DRAWINGS ARE THE DESIGN DRAWINGS FOR THE BUILDING 7 EXPANSION CURRENTLY
ON GOING AND ARE FOR REFERENCE ONLY.
2. ALL EQUIPMENT IN THIS PROJECT WILL BE CONTROLLED BY THE CAMPUS SIEMENS SYSTEM.
MIGRATE ALL CONTROLS TO NEW SERVER.
D C
B G
Alexandria, Louisiana
A&E Design - Upgrade Energy Management Control Systems
October 30, 2013
VA256-12-C-0253
VETERANS HEALTH CARE
SYSTEM
Alexandria, LA
A
U.S. Department of Veterans Affairs
1ST FLOOR PLAN - NORTH WING -
MECHANICAL
7 EXPANSION WLP NMT
M7-301b
M A
T C
H L
IN
E
- S
E E
S H
E E
T M
-3 a
F O
R C
O N
T
IN
U T
A T
IO
N
M A
T C
H L
IN
E
- S
E E
S H
E E
T M
-3 a
F O
R C
O N
T
IN
U T
A T
IO
N
NOTES;
1. THESE DRAWINGS ARE THE DESIGN
DRAWINGS FOR THE BUILDING 7
EXPANSION CURRENTLY ON GOING AND
ARE FOR REFERENCE ONLY.
2. ALL EQUIPMENT IN THIS PROJECT WILL
BE CONTROLLED BY THE CAMPUS
SIEMENS SYSTEM. MIGRATE ALL
CONTROLS TO NEW SERVER.
3. BID ADDITIVE ITEMS A, D, & E WERE NOT
SELECTED.
D C
B G
Alexandria, Louisiana
A&E Design - Upgrade Energy Management Control Systems
October 30, 2013
VA256-12-C-0253
VETERANS HEALTH CARE
SYSTEM
Alexandria, LA
A
U.S. Department of Veterans Affairs
ENLARGED FLOOR PLANS -
MECHANICAL ROOMS
7 EXPANSION WLP NMT
M7-301c
NOTES;
1. THESE DRAWINGS ARE THE DESIGN DRAWINGS FOR THE BUILDING 7 EXPANSION CURRENTLY
ON GOING AND ARE FOR REFERENCE ONLY.
2. ALL EQUIPMENT IN THIS PROJECT WILL BE CONTROLLED BY THE CAMPUS SIEMENS SYSTEM.
MIGRATE ALL CONTROLS TO NEW SERVER.
D C
B G
Alexandria, Louisiana
A&E Design - Upgrade Energy Management Control Systems
October 30, 2013
VA256-12-C-0253
VETERANS HEALTH CARE
SYSTEM
Alexandria, LA
A
U.S. Department of Veterans Affairs
ENLARGED FLOOR PLANS -
MECHANICAL ROOMS
7 EXPANSION WLP NMT
M7-301d
NOTES;
1. THESE DRAWINGS ARE THE DESIGN DRAWINGS FOR THE BUILDING 7 EXPANSION CURRENTLY
ON GOING AND ARE FOR REFERENCE ONLY.
2. ALL EQUIPMENT IN THIS PROJECT WILL BE CONTROLLED BY THE CAMPUS SIEMENS SYSTEM.
MIGRATE ALL CONTROLS TO NEW SERVER.
D C
B G
Alexandria, Louisiana
A&E Design - Upgrade Energy Management Control Systems
October 30, 2013
VA256-12-C-0253
VETERANS HEALTH CARE
SYSTEM
Alexandria, LA
A
U.S. Department of Veterans Affairs
HVAC PENTHOUSE 2C-100 -
MECHANICAL
7 EXPANSION WLP NMT
M7-302
NOTES;
1. THESE DRAWINGS ARE THE DESIGN DRAWINGS FOR THE BUILDING 7 EXPANSION CURRENTLY
ON GOING AND ARE FOR REFERENCE ONLY.
2. ALL EQUIPMENT IN THIS PROJECT WILL BE CONTROLLED BY THE CAMPUS SIEMENS SYSTEM.
MIGRATE ALL CONTROLS TO NEW SERVER.
D C
B G
Alexandria, Louisiana
A&E Design - Upgrade Energy Management Control Systems
October 30, 2013
VA256-12-C-0253
VETERANS HEALTH CARE
SYSTEM
Alexandria, LA
A
U.S. Department of Veterans Affairs
ROOF PLANS - MECHANICAL
7 EXPANSION WLP NMT
M7-303
NOTES;
1. THESE DRAWINGS ARE THE DESIGN DRAWINGS FOR THE BUILDING 7
EXPANSION CURRENTLY ON GOING AND ARE FOR REFERENCE ONLY.
2. ALL EQUIPMENT IN THIS PROJECT WILL BE CONTROLLED BY THE CAMPUS
SIEMENS SYSTEM. MIGRATE ALL CONTROLS TO NEW SERVER.
File details come from the government source that posted it.