This Sources Sought Notice, issued by the Department of Veterans Affairs Network Contracting Office (VISN 15), solicits information from qualified contractors capable of providing annual inspection, testing, reporting, and repair services for backflow prevention devices at the Marion VA Medical Center in Marion, Illinois. The Marion VA Healthcare Center requires comprehensive services covering all backflow prevention devices located on its campus, with work to comply with VHA Directive 1061, NFPA 25, The Joint Commission standards, Illinois Plumbing Code, Illinois EPA Public Water Supplies Regulations, and City of Marion local plumbing codes. The device inventory identified in Appendix A contains approximately 50 backflow prevention devices ranging in size from 1/2 inch to 8 inches, manufactured by companies including Watts, Ames, Febco, Asco, Apollo, and Zurn Wilkins, located across multiple buildings on the Marion campus. All inspections, testing, repairs, and replacements must be performed by technicians holding current Illinois EPA Cross-Connection Control Device Inspector (CCCDI) certification or equivalent ASSE 5110/5130 certification. The contractor shall conduct field verification of all devices during the initial inspection cycle, establish a controlling inventory for subsequent invoicing, and document actual PSI/differential pressure readings against manufacturer-specified thresholds. All test equipment must be calibrated annually or per manufacturer requirements by an accredited calibration source. Responses to this Request for Information are due by September 18, 2026, at 3:00 PM Central Time and should be submitted via email to Contract Specialist Lisa Fischer at Lisa.Fischer1@va.gov.
This Sources Sought Notice identifies the requirement as a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors). Interested contractors must provide their UEI number, business size status and representations, confirmation of small business status under the applicable NAICS code, and documentation of how they intend to meet the 51% self-performance requirement for work outlined in the contract. Responses must demonstrate clear, compelling, and convincing evidence of capability to meet all requirements, including required licensing credentials. Contractors are encouraged to submit pricing and capabilities for planning purposes in accordance with FAR Part 15.201(e). This RFI is issued for information and planning purposes only and does not constitute a formal solicitation; responses are not offers and cannot be accepted to form a binding contract. Following review of responses to this sources sought, a formal solicitation announcement may be published at a later date, and all interested parties must respond separately to that solicitation announcement to be considered for award.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice
SUBJECT* 36C25527Q0005 | BACKFLOW ANNUAL INSPECTION, TESTING & MAINTENANCE | MARION, IL
VA MEDICAL CENTER
GENERAL INFORMATION
CONTRACTING OFFICE’S ZIP CODE* 66048
SOLICITATION NUMBER* 36C25527Q0005
RESPONSE DATE/TIME/ZONE 09-18-2026 15:00 CENTRAL TIME, CHICAGO, USA
ARCHIVE 14 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS N
SET-ASIDE
PRODUCT SERVICE CODE* J045
NAICS CODE* 238220
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway Leavenworth KS 66048
POINT OF CONTACT*
CONTRACT SPECIALIST
LISA FISCHER
LISA.FISCHER1@VA.GOV
PLACE OF PERFORMANCE
ADDRESS MARION VA MEDICAL CENTER
2401 WEST MAIN STREET
MARION IL
POSTAL CODE 62959-1188
COUNTRY USA
DESCRIPTION
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT
DISCLAIMER
1. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this
RFI.
2. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI In Accordance With (IAW) FAR Part 15.201(e).
SOURCES SOUGHT DESCRIPTION: ANNUAL INSPECTIONS, TESTING, REPORTING AND REPAIRS FOR
BACKFLOW DEVICES FOR MARION, IL VA MEDICAL CENTER
3. This is NOT a solicitation announcement. This is a RFI/sources sought only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 238220. Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After reviewing the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement.
4. The Department of Veterans Affairs (VA), VISN 15 Network Contracting Office, is seeking sources that can provide the following:
The Marion VA Healthcare Center requires a qualified firm to provide annual inspection, testing, and repair services for all backflow prevention devices on the Marion campus. All work must comply with VHA Directive 1061, NFPA 25, The Joint Commission standards, Illinois Plumbing Code (77 Ill. Adm. Code 890), Illinois EPA Public Water Supplies Regulations (35 Ill. Adm. Code 604.1505 / 653.801–805), and City of Marion IL Local Plumbing Codes. All inspections, testing, repairs, and replacements shall be performed only by technicians holding a current Illinois EPA Cross-Connection Control Device Inspector (CCCDI) certification or equivalent ASSE 5110/5130 certification.
This contract covers annual inspection, testing, reporting, and repair/replacement services for all backflow prevention devices located at the Marion VAMC campus, as identified in Appendix A: Device List. Appendix A identifies the devices on record as of May 28, 2026, for reference only. The contractor shall field-verify all device counts, locations, and identify information during the initial inspection cycle and report any discrepancies to the COR in writing. The field-verified count established during the initial inspection cycle shall serve as the controlling inventory for all subsequent invoicing and performance periods.
Each device shall be tested in accordance with the manufacturer's specifications and an accepted cross-connection control testing standard (e.g., USC-FCCCHR manual), using test equipment calibrated in accordance with Section 10.3. Test results shall record actual PSI/differential pressure readings against the manufacturer-specified pass threshold for that device — a simple pass/fail notation without supporting readings is not acceptable.
All test gauges/equipment used under this contract shall be calibrated at least annually (or per manufacturer requirement) by an accredited calibration source. Calibration certificates shall be made available to the COR upon request.
For each backflow device, the contractor shall confirm and record:
• Tag/ID number and precise location (sufficient for any party to quickly locate the device without ambiguity)
• Make, model, serial number, and size
Appendix A: Device List:
Device Location Serial Number Size Manufacturer
Bldg 1 Rm 30 F060810417 6" Hebco
Bldg 1 Rm 30 102813 1" Watts
Bldg 1 Rm 30 653770 3/4" Watts
Bldg 1 West Penthouse 461757 3/4" Watts
Bldg 1 Rm 501 654186 3/4" Watts
Bldg 1 Rm 417 630246 3/4" Watts
Bldg 1 Rm 401 168464 3/4" Watts
Bldg 1 Rm 401 225450 3/4" Watts
Bldg 2 Sub Basement MF - 0348 6" Ames
Bldg 2 Sub Basement 044284 3 /4" Watts
Bldg 2 Rm 223 253758 2" Watts
Bldg 2 East Penthouse 349428 3/4" Watts
Bldg 2 Central Penthouse 084792 3/4" Watts
Bldg 7 Rm 124 64397B 2" Apollo
Bldg 7 Rm 124 31817 6" Zurri Wilkins
Bldg 8 Mech Rm 375XLRP 2" Zurri Wilkins
Bldg 8 Mech Rm G53781 4" Back Flow, Direct
Bldg 13 Basement KK-1005 4" Watts
Bldg 14 Boiler Rm 207262 2" Watts
Bldg 14 Basement 463681 2" Watts
Bldg 16 Rm 105b 164200 4" Watts
Bldg 37 Rm UPS 628759 3/4" Watts
Bldg 37 Rm 111 RJ 1986 4" Ames
Bldg 37 Hallway A 10515 1/2" Watts
Bldg 37 Hallway 626317 3/4" Watts
Bldg 42 Basement 117655 3/4" Watts
Bldg 42 Basement 919609 1/2" Apollo
Bldg 42 Rm C115 127324 3/4" Watts
Bldg 42 Lab B33 134220 3/4" Watts
Bldg 42 Basement 251293 6" Watts
Bldg 42 Basement 251294 6" Watts
Bldg 43 Rm 163 160440 4" Watts
Bldg 43 Rm 163 055227 3/4" Watts
Bldg 43 Rm 163 490372 3/4" Watts
Bldg 49 Chiller Plant 118516 3/4" Watts
Bldg 49 Chiller Plant 2 EM 1249 2 1/2" Ames
Bldg 49 Chemical 104257 3/4" Watts
Bldg 81 Rm B-05 LA-0398 4" Ames
Bldg 81 Rm B-05 213326 3/4" Ames
Bldg 81 Rm B-01 319213 3 /4 " Watts
Bldg 82 AmVet 641785 3/4 " Watts
Bldg 82 AmVet 254869 2" Watts
Bldg 82 AmVet 1003680810 4" Ames
Bldg 82 AmVet 11346 3/4" Ames
Bldg 83 Rm 301 527523 2" Apollo
Bldg 83 Mech Rm 174368 6" Ames
Bldg 83 Rm 143A Q08425 3" Wilkins
Bldg 84 Mech Rm 11216D 4" Zurn Wilkins
Bldg 84 Mech Rm ZF-4358 3" Watts
Bldg 84 Mech Rm ZG-0272 3" Watts
Bldg 84 Mech Rm 357405 1" Watts
Mod-1 Rm 125 EJ 0059 6" Ames
Copeland Dr 12981 8" Febco
Rock 9509081508 8" Febco
5. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the requirement. If you are interested and are capable of providing the sought-out services, please provide the requested information as well as the information indicated below. Failure to respond to all questions in this sources sought will determine the interested party as non-responsive which may affect a set-aside decision for a resulting solicitation.
Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:
a. Please provide your UEI number.
b. Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)?
c. Is your company considered small under the NAICS code identified under this RFI?
d. If you are identified as a SDVOSB/VOSB or SB, identify how you intend to meet the requirements found in the limitations on subcontracting FAR or VAAR clauses. (providing 51% of the work outlined in section 4 above)
e. Does your company have an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed above? If so, please provide the contract number(s).
f. Please submit your capabilities that show clear, compelling, and convincing evidence that you can meet the requirement described above to include required licensing.
6. Responses to this notice shall be submitted via email to Lisa Fischer at Lisa.Fischer1@va.gov.
Telephone responses shall not be accepted. Responses must be received no later than Friday September 18th, 2026, at 1500 CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.