231997 Womens Clinic_Amendment 01 - Combined Drawings_2025-11-04.pdf
PDF 3 MB Posted
- Attached to
- Z2DA--Construct Women's Clinic PN:589A4-24-103
- Solicitation number
- 36C25525R0129
About this file
These are architectural and engineering drawings for a Women's Clinic construction project for the U.S. Department of Veterans Affairs, located at 800 Hospital Drive in Columbia, Missouri. The documents include detailed plumbing plans for a fully sprinklered first floor, with specific specifications for fixtures like water closets (American Standard Madera), lavatories (American Standard Lucerne), and sinks (Elkay Lustertone). The project is designed by Stone Group Architects, with mechanical engineering by Farris Engineering and structural engineering by ERA Structural Engineering, and is currently in the Bid Set phase with an issue date of 06/24/2025. The drawings provide comprehensive technical details for plumbing infrastructure, including domestic water and sanitary/vent systems, with precise connection sizes, fixture types, and installation requirements compliant with ADA standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 00 01 10 Table of Contents_REV1_2025-11-04.pdf | ||
| Pre-Bid Sign in Sheet.pdf | ||
| 11 40 11 Custom Fabricated Foodservice Equipment.pdf | ||
| 36C25525R0129 0001.docx | DOCX document | |
| P09-Final Specifications Vol 1 686 pages.pdf | ||
| 2025-06-25 DRAWING 55 pages.pdf | ||
| 36C25525R0129.docx | DOCX document | |
| P09-Final Specifications Vol 2 - 602 pages.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL FINISH NOTES
H. BASIS OF DESIGN FOR SELECTED FINISHES IS IDENTIFIED ON COLOR & MATERIAL SCHEDULE.
ARCHITECT APPROVAL IS REQUIRED FOR ALL FINISHES.
I. SOME SPECIFIED PRODUCTS AND FINISHES MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY
RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.
J. ALL FINISH WORK SHALL BE PERFORMED IN COMPLIANCE WITH DRAWINGS & SPECIFICATIONS. SHOP DRAWINGS, SAMPLES & PRODUCT DATA SHALL BE SUBMITTED TO THE ARCHITECT FOR THEIR REVIEW
PRIOR TO BEGINNING WORK.
REFER TO ROOM FINISH SCHEDULE AND COLOR AND MATERIAL SCHEDULE FOR THE FINISH
SELECTIONS OF EACH INDIVIDUAL ROOM NOT OTHERWISE DESIGNATED ON INTERIOR DRAWINGS.
L. FLOOR FINISH LEGEND HATCHES/PATTERNS INDICATE FLOORING TYPES, NOT ACTUAL FLOORING PATTERN & LAYOUT UNO. FOR FLOOR PATTERN INSTALL DIRECTION REFER TO THE INSTALLATION
SYMBOL.
M. EXTEND ALL FLOORING UNDER FURNITURE, DESKS, COUNTERTOPS, ETC. UNO FINISH PLAN MAY NOT
INDICATE FLOORING UNDER OPEN COUNTERTOPS, CASEWORK, EQUIPMENT, ETC.
N. PROVIDE TRANSITION STRIPS AT ALL LOCATIONS THAT HAVE A CHANGE IN FLOORING MATERIALS.
REFER TO TYPICAL TRANSITION STRIP DETAILS FOR APPROVED TRANSITION STRIPS.
O. ALL FLOORING TRANSITIONS TO BE CENTERED UNDER DOORS IN A CLOSED POSITION UNO.
P. CONTRACTOR IS RESPONSIBLE FOR VERIFYING APPROPRIATE SIZES OF TRANSITION STRIPS BASED
ON MATERIAL TYPES.
Q. ALL VINYL TRANSITION STRIP COLORS TO MATCH ADJACENT FLOORING UNO.
R. ALL SOLID SURFACE SINK FINISHES AND MATERIALS TO MATCH THE INFORMATION PROVIDED IN THE
COLOR AND MATERIAL SCHEDULE.
S. ALL INTERIOR GWB WALLS AND CEILINGS SHALL RECEIVE A LEVEL 4 FINISH WITH LIGHT ORANGE PEEL
TEXTURE UNO AND PAINTED ACCORDING TO THE INFORMATION PROVIDED IN THE COLOR AND
MATERIAL SCHEDULE AND ROOM FINISH SCHEDULE.
T. ALL SCHLUTER TRANSITION STRIPS TO BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
U. VERIFY GROUT & MORTAR THICKNESS PER MANUFACTURER'S RECOMMENDATIONS.
V. JOINTS IN FLOORING SHOULD ALIGN WITH JOINTS IN CONCRETE SLABS. ADDITIONAL JOINTS SHOULD
BE CUT IF NECESSARY AS PER THE LATEST EDITION OF THE TCNA HANDBOOK. VERIFY LOCATIONS
WITH ARCHITECT & INTERIOR DESIGNER.
W. WOOD DOORS AND FRAME BASE MOLDINGS TO BE FILLED, STAINED, SEALED & SHOP FINISHED TO
MATCH ARCHITECTS SAMPLE. WORK SHOULD BE PERFORMED IN A DUST FREE ENVIRONMENT.
X. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED OR PREFINISHED ACCORDING TO THE
INFORMATION PROVIDED IN THE COLOR AND MATERIAL SCHEDULE AND ROOM FINISH SCHEDULE.
Y. SOFFIT OR BULKHEAD PAINT COLOR TO BE APPLIED TO BOTH VERTICAL AND HORIZONTAL SURFACES UNO. ALL SOFFITS TO BE PAINTED THE COLOR OF ADJACENT WALLS UNO. SPECIAL ACCENT COLORS
ARE INDICATED ON THE REFLECTED CEILING PLAN AND ROOM FINISH SCHEDULE.
Z. REFER TO REFLECTED CEILING PLANS AND ROOM FINISH SCHEDULE FOR INFORMATION REGARDING
CEILING FINISHES AND SYSTEMS.
AA. REFER TO INTERIOR ELEVATIONS FOR WALL TILE PATTERNS.
AB. PROVIDE ADA COMPLIANT SIGNAGE FOR ALL REQUIRED AREAS, ROOMS, & ACCESSIBLE PATHS.
AC. ALL METAL COMPONENTS TO BE PAINTED OR PREFINISHED ACCORDING TO THE INFORMATION
PROVIDED IN THE COLOR AND MATERIAL SCHEDULE AND ROOM FINISH SCHEDULE.
AD. CORNER GUARDS ARE TO BE INSTALLED AT ALL OUTSIDE CORNERS IN PUBLIC SPACES AND
CORRIDORS.
AE. ALL WINDOW SILLS TO BE SOLID SURFACE UNO.
AF. REFERENCE SPECIFICATIONS, ELEVATIONS, AND DETAIL DRAWINGS FOR SPECIAL MATERIALS.
AG. WOOD GRAIN LAMINATES TO BE INSTALLED WITH WOOD GRAIN RUNNING VERTICALLY UNO.
AH. WHERE TRIM IS NOT SPECIFIED, CAULK ALL EXPOSED EDGES OR SEAMS OF RVS WITH CLEAR
CAULKING.
AI. CAULK BETWEEN BASE OF DOOR FRAMES TO ALL FINISHED HARD SURFACE FLOORING.
AJ. INSTALL GROUT COLOR MATCHING FLEXIBLE SEALANT MAPEI "MAPESIL T" AT ALL CHANGE OF PLANE
LOCATIONS PER TCNA.
A.
B.
C.
D.
E.
F.
G.
ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER BEFORE
PROCEEDING WITH THE WORK.
WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
DETAILS SHOWN ARE TYPICAL UNO. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
SEE STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR GRID UNO. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UNO.
CONSTRUCTION LEGEND
SHADED AREA NOT IN SCOPE OF WORK
NEW COMPONENTS
TRUE
NORTH
PLAN
NORTH
A128
SWAMP
A125
ENTRY/WAITING
A124
RESTROOM
A119
CLEAN
A123
RESTROOM
A126
PROCEDURE1
A121
EXAM/TELEHEALTH/CONSULT
A127
MSA
CHECK-IN
A122
PROCEDURE2
A120
SOILED
A124B
INTAKE
A128A
NURSE
STATION
A124A
NURSE
STATION
C1A3
CORRIDOR
C1E33
CORRIDOR
WSF-2WSF-2
WSF-2
WSF-2
PT-1
PT-1
PT-2
TS-1
TS-1
TS-1
TS-2C1E34
CORRIDOR WSF-1
WSF-2
WSF-2
WSF-2
MT-3
TS-2
TS-2
WSF-2
8"
8" 8"
8"
8"
8"
4 1 /2"
8"
P-2
P-2 P-2
P-2
P-2
P-2 P-2
P-2
P-2P-2
7.14
4'- 8"
4'- 7"4'-
7 2 9/2
8"1'- 2 7
/8"
8"
NOTE
A. THIS PLAN DEPICTS FLOOR FINISH
MATERIALS & ACCENT PAINT LOCATIONS.
B. REFER TO COLOR & MATERIAL SCHEDULE
AND ROOM FINISH SCHEDULE FOR
MATERIAL SELECTIONS OF EACH
INDIVIDUAL ROOM.
FLOOR FINISH LEGEND
TAG
PT-1
WSF-1
PATTERN DESCRIPTION
PORCELAIN TILE
WELDED SEAM SHEET
XXX-# FINISH TYPE INDICATOR
EFR EXISTING FINISHES TO REMAIN
MEF MATCH EXISTING FINISHES
FLOORING DIRECTION
DESCRIPTIONSYMBOL
FINISH EXTENT LINE
FINISH SEAM OR TRANSITION
FINISH TYPES INDICATED THUS:
FINISH DESCRIPTION
FINISH TYPE #
XXX-#FINISH TAG
WSF-2 WELDED SEAM SHEET
PT-2 PORCELAIN TILE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
A
B
C
D
2 4 5
PhaseDESIGNER OF RECORD A/E:
STAMPCONSULTANTS
MEP:
FARRIS ENGINEERING
12700 WEST DODGE ROAD
OMAHA, NE 68154
402.330.5900
STRUCTURAL:
ERA STRUCTURAL ENGINEERING
110N. ANKENY BLVD. SUITE 200
ANKENY, IA 50023
515.384.1001
6"
6"
6"
6"
ON
E
EI
GH
TH
IN
CH
O
NE
F
OO
T (1
/8"
1' -0
ON
E
QU
AR
TE
R
IN
CH
O
NE
F
OO
T (1
/4"
1' -0
TH
RE
E
EI
GH
TH
S
IN
CH
O
NE
F
OO
T
(3 /8"
1'
-0
ON
E
HA
LF
IN
CH
O
NE
F
OO
T
(1 /2"
1'
-0
TH
RE
E
QU
AR
TE
RS
IN
CH
O
NE
F
OO
T (3
/4"
1' -0
ON
E
IN
CH
O
NE
F
OO
T (1
1'
-0
ON
E
AN
D
ON
E
HA
LF
IN
CH
ES
O
NE
F
OO
T (1
1/ 2"
1'
-0
TH
RE
E
IN
CH
ES
O
NE
F
OO
T
(3
1' -0
32 4 5 61
C:
\U se rs\
A.
Sc hlo me r\D oc um en ts\
W
OM
EN
S
CL
IN
IC
_a utu mn sR
AF
.rv t
/4/
4:
:34
P M
AI101
FINISH PLAN & SCHEDULE - 1ST FLOOR
STONE GROUP ARCHITECTS
117 PIERCE STREET, SUITE 110
SIOUX CITY, IA 51101
(712)252-4014
CONSTRUCT WOMEN'S CLINIC
800 HOSPITAL DRIVE COLUMBIA, MO 65201
06/25/2025 BF/TM AS
SGA #231997
VA #589A4-24-103BID SET
KEYNOTES
KEY VALUE KEYNOTE TEXT
7.14 RECESS MOUNT EXPANSION JOINT.
1/4" = 1'-0"D2 FINISH PLAN - 1ST LEVEL
COLOR & MATERIAL SCHEDULE
FINISH DESCRIPTION MANUFACTURER
STYLE COLOR
SIZE & TYPE SPECIAL INFO / NOTESNAME & DESCRIPTION NAME & DESCRIPTION
CEILINGS
ACT-1 ACOUSTIC CEILING TILE ARMSTRONG ULTIMA SQUARE LAY-IN #1910 / WHITE 24"X24"X3/4" SQ. EDGE GRID 15/16" IN WHITE
FLOORING
PT-1 PORCELAIN TILE (FLOORS) PORTOBELLO AMERICA NORIAN MATTE NORIAN ASH 12"X24"X0.3" PT-2 PORCELAIN TILE (EXISTING LAYOUT) DALTILE PORTFOLIO ICE 12"X24"X0.3" MATCH TILE ORIENTATION TO EXISTING TILE IN CORRIDOR
WSF-1 WELDED SEAM SHEET TEKNOFLOR NATURESCAPES HPD JASPER OAK, BEACH 6.594'W X 65.617'L ROLLS; 0.098" THICK HEAT WELD EDGES OF SHEET NINYL; WELDING STRIP TO MATCH WSF-2 WELDED SEAM SHEET TEKNOFLOR NATURESCAPES HPD JASPER OAK, NATURAL CHERRY 6.594'W X 65.617'L ROLLS; 0.098" THICK HEAT WELD EDGES OF SHEET NINYL; WELDING STRIP TO MATCH
MISCELLANEOUS
CG-1 CORNER GUARD INPRO CORPORATION 150 SLATE 3" WING
CG-2 CORNER GUARD INPRO CORPORATION FLEXIBLE VINYL CLEAR 1-1/8" WINGS X 4' HIGH CORNERS AT ENTRY - REFERENCE WALL PROTECTION PLAN
CR-1 CRASH RAIL INPRO CORPORATION 1400 SLATE 4" H MOUNT DIRECTLY ABOVE WALL BASE
EG-1 END GUARD INPRO CORPORATION G2-150RD SLATE 3" WING
HR-1 HANDRAIL & SUPPORT INPRO CORPORATION 910 ESPRESSO 5-1/2" H MOUNT 36" A.F.F. TO TOP MT-1 METAL TRIM SCHLUTER SYSTEMS DILEX ANODIZED ALUMINUM INSTALLER TO VERIFY SIZE REQUIRED MT-2 METAL TRIM SCHLUTER SYSTEMS RONDEC ANODIZED ALUMINUM INSTALLER TO VERIFY SIZE REQUIRED MT-3 METAL TRIM SCHLUTER SYSTEMS JOLLY STAINLESS STEEL INSTALLER TO VERIFY SIZE REQUIRED FLOOR TRANSITION FROM TILE TO WSF PL-1 PLASTIC LAMINATE (CABINETRY) FORMICA LAMINATE SILVER RIFTWOOD - ANTIMICROBIAL REFERENCE INTERIOR ELEVATIONS PL-5 RIGID VINYL SHEET INPRO CORPORATION S600-060 DESIGNER WHITE VARIES FROM 8" - 11" X 0.06" THICK "WOMEN'S CLINIC" SIGN AT ENTRY
RB-1 RESILIENT BASE JOHNSONITE TG6 - COVED MINK 6"
RB-2 RESILIENT BASE JOHNSONITE COVED BLACK 6"
TR-1 RIGID SEAM TRIM & TOP CAP INPRO CORPORATION PALLADIUM SLATE (AS NECESSARY FOR WALL COVERING
PANELS)
INSTALL AT JOINTS WHERE REQUIRED
TR-2 RIGID WALL COVERING SEAM TRIM &
TOP CAP
FORMICA 8681 COTTON CLOTH 4' H (AS NECESSARY FOR WALL COVERING
PANELS)
INSTALL AT JOINTS WHERE REQUIRED
TR-3 METAL BASE TRIM (ENTRY) SCHLUTER ALUMINUM MATCH EXISTING ATRIUM - REFERENCE INTERIOR ELEVATIONS TR-4 RESILIENT BASE COVE CAP JOHNSONITE SCC 48 B GREY 3/4 H X 1/4" W CAP AT COVE BASE OF WSF-1 AND WSF-2 WHERE "COVE BASE" IS DESIGNATED ON INTERIOR
ELEVATIONS
TS-1 TRANSITION STRIP (PT TO WSF) SCHLUTER SYSTEMS JOLLY A100G GREY INSTALLER TO VERIFY SIZE REQUIRED FLOOR TRANSITION FROM PT TO WSF TS-2 TRANSITION STRIP (EXISTING TO WSF) SCHLUTER SYSTEMS JOLLY A100G GREY INSTALLER TO VERIFY SIZE REQUIRED FLOOR TRANSITION FROM EXISTING TO WSF
SURFACES
SS-1 SOLID SURFACE (COUNTERTOPS) CORIAN SOLID SURFACE LIMESTONE PRIMA 1/2" THICK
WALL COVERING
ADH-1 WINDOW ADHESIVE DECORATIVE FILMS SXJ-0561 FINE DOTS GRADIENT - WHITE 60" x 95' ROLL APPLY TO BOTH WINDOWS AT MSA CHECK-IN
P-1 PAINT (WALLS-TYPICAL) SHERWIN-WILLIAMS HARMONY ZERO VOC; MPI 52 INCREDIBLE WHITE EGGSHELL P-1S PAINT (WALLS-SEMI-GLOSS) SHERWIN-WILLIAMS HARMONY ZERO VOC; MPI 54 INCREDIBLE WHITE SEMI-GLOSS P-2 PAINT (ACCENT WALLS) SHERWIN-WILLIAMS HARMONY ZERO VOC; MPI 52 JUBILEE EGGSHELL
PL-2 PHENOLIC WALL PANELING PLASTIC
LAMINATE (ENTRY SLATS)
FORMICA LAMINATE WILD CHERRY 1/2" THICK REFERENCE ENLARGED FLOOR PLANS/ELEVATION
PL-3 PHENOLIC WALL PANELING PLASTIC
LAMINATE (ENTRY SLATS)
FORMICA LAMINATE BLACK 1/4" THICK REFERENCE ENLARGED FLOOR PLANS/ELEVATION
PL-4 PLASTIC LAMINATE (ENTRY BORDER) FORMICA LAMINATE CHERRY WALNUT 1/16" THICK REFERENCE ENLARGED FLOOR PLANS/ELEVATION PT-2A PORCELAIN TILE (WALLS) PORTOBELLO AMERICA KREA SMOOTH NAVY 3X12 70% OF WALL TILE ON DESIGNATED WALL - REFERENCE INTERIOR ELEVATIONS PT-2B PORCELAIN TILE (WALLS) PORTOBELLO AMERICA KREA RIPPLE NAVY 3X12 30% OF WALL TILE ON DESIGNATED WALL - REFERENCE INTERIOR ELEVATIONS RWC-1 RIGID VINYL WALL COVERING INPRO CORPORATION PALLADIUM SLATE 4'H; EMBOSSED TEXTURE, 0.06" THICK
RWC-2 RIGID VINYL WALL COVERING
(HIGH-PRESSURE)
FORMICA 8681 COTTON CLOTH 48" X 96" X 0.035" THICK SHEETS
ROOM FINISH SCHEDULE
ROOM # ROOM NAME FLOOR BASE
WALLS (ORIENTATION BASED ON PLAN NORTH NOT TRUE NORTH)
CEILING ID FINISH REMARKSNORTH EAST SOUTH WEST
A119 CLEAN WSF-2 WSF-2 P-1/RWC P-1/RWC P-1/RWC P-1/RWC AT-1 6" INTEGRAL COVE BASE A120 SOILED WSF-2 WSF-2 P-1S/RWC P-1S/RWC P-1S/RWC P-1S/RWC AT-1 6" INTEGRAL COVE BASE A121 EXAM/TELEHEALTH/CONSULT WSF-2 WSF-2 P-1 P-1 P-2 P-1 AT-1 REFER TO FINISH PLAN FOR PAINT DESIGNATION A122 PROCEDURE2 WSF-2 WSF-2 P-2 P-1 P-1 P-1 AT-1/SP REFER TO FINISH PLAN FOR PAINT DESIGNATION / 6" COVE BASE A123 RESTROOM PT-1 PT-2A/PT-2B P-2/PT-2A/PT-2B P-1/PT-2A/PT-2B P-1/PT-2A/PT-2B P-1/PT-2A/PT-2B GWB REFER TO FINISH PLAN FOR PAINT DESIGNATION A124 RESTROOM PT-1 PT-2A/PT-2B P-1/PT-2A/PT-2B P-1/PT-2A/PT-2B P-2/PT-2A/PT-2B P-1/PT-2A/PT-2B GWB REFER TO FINISH PLAN FOR PAIN DESIGNATION A124A NURSE STATION WSF-1/WSF-2 RB-1 - P-1 P-2 P-1 AT-1 REFER TO FINISH PLAN FOR PAINT/FLOORING DESIGNATION A124B INTAKE WSF-2 RB-1 - P-1 P-2 P-1 AT-1 REFER TO FINISH PLAN FOR PAINT DESIGNATION A125 ENTRY/WAITING WSF-1 RB-1 P-2 P-1 P-1 P-1 AT-1 REFER TO FINISH PLAN FOR PAINT DESIGNATION A126 PROCEDURE1 WSF-2 WSF-2 P-1/P-2 P-1 P-1 P-1 AT-1 REFER TO FINISH PLAN FOR PAINT DESIGNATION / 6" COVE BASE A127 MSA CHECK-IN WSF-1/WSF-2 RB-1 P-1 P-1 - P-1 AT-1 REFER TO FINISH PLAN FOR FLOORING DESIGNATION A128 SWAMP WSF-2 RB-1 P-1 P-1 P-2 P-1 AT-1 REFER TO FINISH PLAN FOR PAINT DESIGNATION A128A NURSE STATION WSF-1/WSF-2 RB-1 - P-1 P-2 P-1 AT-1 REFER TO FINISH PLAN FOR PAINT DESIGNATION C1A3 CORRIDOR WSF-1/WSF-2 RB-1/CR-1* P-1 P-1 P-1 P-1 AT-1 REFER TO FINISH PLAN FOR PAINT DESIGNATION/*CR-1 DESIGNATION ON
WALL PROTECTION PLAN AND INTERIOR ELEVATIONS
C1E33 CORRIDOR PT-2 RB-2 - P P/WD P GWB/P
C1E34 CORRIDOR WSF-1/WSF-2 RB-1 P-1 P-1 P-1 P-1 AT-1
REVISION # DESCRIPTION DATE
01 AMENDMENT 01 11/4/2025
01 01
A.Schlomer Image
GENERAL WALL PROTECTION NOTES
H. BASIS OF DESIGN FOR SELECTED FINISHES IS IDENTIFIED ON MATERIAL & COLOR SCHEDULE.
ARCHITECT APPROVAL IS REQUIRED FOR ALL FINISHES.
I. SOME SPECIFIED PRODUCTS AND FINISHES MAY HAVE SUBSTANTIAL LEAD TIMES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PLACING ORDERS IN A MANNER TO ENSURE THEIR TIMELY ARRIVAL. THE CONTRACTOR SHALL BE RESPONSIBLE FOR EXPENSES, INCLUDING DESIGN FEES, RELATED TO ANY
RESELECTIONS REQUIRED DUE TO FAILURE TO ORDER PRODUCTS IN A TIMELY MANNER.
J. WALL PROTECTION PLAN DEPICTS WALL PROTECTION LOCATIONS AND FINISH LOCATIONS IN AREAS OF SPECIAL SIGNIFICANCE, I.E., MATERIAL CHANGES WITHIN A SINGLE ROOM OR SPACE. REFER TO ROOM FINISH SCHEDULE AND MATERIAL & COLOR SCHEDULE FOR THE FINISH SELECTIONS OF EACH
INDIVIDUAL ROOM NOT OTHERWISE DESIGNATED ON PLAN.
K. REFER TO INTERIOR ELEVATIONS FOR WALL TILE PATTERNS.
L. VERIFY GROUT AND MORTAR THICKNESS PER MANUFACTURER'S RECOMMENDATIONS.
M. INSTALL ALL WALL CONERGUARDS, ANGLE GUARDS, & END GUARDS ABOVE WALL BASE.
N. INSTALL RIGID VINYL SHEET ABOVE WALL BASE.
O. REFER TO COLOR & MATERIAL SCHEDULE & SPECIFICATIONS MANUAL FOR WALL PROTECTION
MANUFACTURER, SIZE, & COLOR.
A.
B.
C.
D.
E.
F.
G.
ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER BEFORE
PROCEEDING WITH THE WORK.
WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
DETAILS SHOWN ARE TYPICAL UNO. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
SEE STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR GRID UNO. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UNO.
NOTE
A. SEE WALL PROTECTION PLANS & INTERIOR ELEVATIONS FOR WALL PROTECTION LOCATIONS.
B. SEE COLOR & MATERIAL SCHEDULE FOR MORE INFORMATION REGARDING WALL PROTECTION TYPES.
WALL PROTECTION LEGEND
INDICATED THUS ON PLANS:
FINISH TYPE #
WALL GUARDS
CG-#.#FINISH TAG
DESCRIPTION
OTHER WALL PROTECTION
CORNER GUARD (TYPICAL)
CORNER GUARD (END GUARD)
CORNER GUARD (ANGLE GUARD)
CORNER GUARD (ANGLE GUARD) HEIGHT IN FEET
TAGGING / LABELING:PLAN GRAPHICS & DESCRIPTION:
CORNER GUARD (CG-XX)
WALL GUARD (WG-1)
RIGID WALL COVERING (RWC-X.X)
HANDRAIL WITH CRASH RAIL (HR-1, CR-X)
TYPE IDENTIFICATION:
INDICATED THUS ON PLANS:LINE TYPE DESCRIPTION
CG-#.#
CONSTRUCTION LEGEND
SHADED AREA NOT IN SCOPE OF WORK
NEW COMPONENTS
TRUE
NORTH
PLAN
NORTH
A128
SWAMP
A125
ENTRY/WAITING
A124
RESTROOM
A119
CLEAN
A123
RESTROOM
A126
PROCEDURE1
A121
EXAM/TELEHEALTH/CONSULT
A127
MSA
CHECK-IN
A122
PROCEDURE2
A120
SOILED
A124B
INTAKE
A128A
NURSE
STATION
A124A
NURSE
STATION
C1A3
CORRIDOR
C1E33
CORR.
HR-1, CR-1
HR-1, CR-1
HR-1, CR-1
HR-1, CR-1
RWC-1.4
RWC-1.4
RWC-1.4
RW
C-
1.4
RWC-1.4RWC-1.4
RW
C-
1.4
RWC-1.4
CG-1.F
CG-1.F
CG-1.F
CG-1.F CG-1.F EG-1.F CG-1.F
CG-1.F
CG-1.F
CG-1.F
CG-1.F CG-1.F
CG-1.F
CG-1.F
CG-1.F
CG-1.F
CG-1.F
CG-1.F
CG-1.F
RW
C-
1.4
RW
C-
1.4
RWC-1.4
RWC-1.4
RWC-1.4
RWC-2.4RWC-2.4
RWC-2.4
CG-2.4 CG-2.4
RWC-2.28"
6"
GYP. BD.
COVE CAP (RB-2)
COVE STICK AS REQ'D
BY MANUFACTURER
SHEET FLOORING
MATERIAL (WSF-2),
REF. C&M SCHEDULE
CLEAR SILICONE CAULK AT
COVE CAP & BOTTOM OF RWC
RIGID WALL COVERING
(RWC-1) AS SCHEDULED
A.
F.
F
- R
EF
C
&M S
C H
ED
GYP. BD.
FASTENER
CONTINUOUS
ALUMINUM RETAINER
MOUNTING BRACKET
2" 1 1/2"
3 1/2"
CLEAR SILICONE CAULK
AT TOP OF BRACKET &
WALL JOINT
VINYL COVER
1/2" BRACKET SPACER
MACHINE SCREW WITH
SERRATED FLANGE
NUT
5/
N
TS
TOP CAP, REF SPEC & C&M SCHED.
RIGID WALL COVERING (RWC-1) AS
SCHEDULED
CLEAR SILICONE CAULK AT
TOP CAP & WALL JOINT
A.
F.
F
- R
EF
C
&M S
C H
ED
GYP. BD.
GYP. BD.
HIGH-IMPACT
RESILIENT COVER
FASTENER
CONTINUOUS
ALUMINUM
RETAINER
BLOCK'G
AS REQ'D
CONTINUOUS
IMPACT BUMPER
4"
CLEAR SILICONE CAULK
AT TOP OF CRASH RAIL
& WALL JOINT
BASE AS
SCHEDULED
6"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
A
B
C
D
2 4 5
PhaseDESIGNER OF RECORD A/E:
STAMPCONSULTANTS
MEP:
FARRIS ENGINEERING
12700 WEST DODGE ROAD
OMAHA, NE 68154
402.330.5900
STRUCTURAL:
ERA STRUCTURAL ENGINEERING
110N. ANKENY BLVD. SUITE 200
ANKENY, IA 50023
515.384.1001
6"
6"
6"
6"
ON
E
EI
GH
TH
IN
CH
O
NE
F
OO
T (1
/8"
1' -0
ON
E
QU
AR
TE
R
IN
CH
O
NE
F
OO
T (1
/4"
1' -0
TH
RE
E
EI
GH
TH
S
IN
CH
O
NE
F
OO
T
(3 /8"
1'
-0
ON
E
HA
LF
IN
CH
O
NE
F
OO
T
(1 /2"
1'
-0
TH
RE
E
QU
AR
TE
RS
IN
CH
O
NE
F
OO
T (3
/4"
1' -0
ON
E
IN
CH
O
NE
F
OO
T (1
1'
-0
ON
E
AN
D
ON
E
HA
LF
IN
CH
ES
O
NE
F
OO
T (1
1/ 2"
1'
-0
TH
RE
E
IN
CH
ES
O
NE
F
OO
T
(3
1' -0
32 4 5 61
C:
\U se rs\
A.
Sc hlo me r\D oc um en ts\
W
OM
EN
S
CL
IN
IC
_a utu mn sR
AF
.rv t
/4/
4:
:35
P M
AI121
WALL PROTECTION PLAN - 1ST FLOOR
STONE GROUP ARCHITECTS
117 PIERCE STREET, SUITE 110
SIOUX CITY, IA 51101
(712)252-4014
CONSTRUCT WOMEN'S CLINIC
800 HOSPITAL DRIVE COLUMBIA, MO 65201
06/25/2025 BF/TM AS
SGA #231997
VA #589A4-24-103BID SET
KEYNOTES
KEY VALUE KEYNOTE TEXT
1/4" = 1'-0"D2 WALL PROTECTION PLAN - 1ST LEVEL
REVISION # DESCRIPTION DATE
01 AMENDMENT 01 11/4/2025
6" = 1'-0"A4 DETAIL - WALL PROT AT COVE BASE (TR-4)
3" = 1'-0"A5 DETAIL - HANDRAIL (HR-1)
6" = 1'-0"A3 DETAIL - WALL PROT TOP CAP (TR-1/TR-2)
3" = 1'-0"A2 DETAIL - CRASH RAIL (CR-1)
GENERAL INTERIOR ELEVATION NOTES
H. PROVIDE BACKING FOR ALL EQUIPMENT & HANDRAILS ATTACHED TO BUILDING WALLS.
I. WOOD BACKING IN MTL STUD WALLS AND/OR RATED WALLS TO BE FIRE TREATED UNO.
J. GWB USED IN RESTROOMS, JANITOR CLOSETS, AND OTHER AREAS OF EXPOSED MOISTURE TO BE
WATER RESISTANT GWB UNO.
K. HEIGHT OF OPERATIONAL AND/OR DISPENSING PORTION OF EQUIPMENT & FIXTURES NOT TO EXCEED
48" AFF UNO.
L. SEE SCHEDULES & LEGENDS FOR MORE INFORMATION REGARDING WINDOW AND DOOR TYPES.
M. GWB CONTROL JOINTS SHALL BE INSTALLED AS PER THE LATEST EDITIONS OF GA-216 & ASTM C840
UNO. PROVIDE CONTROL JOINTS IN GWB EVERY 30'-0" MIN.
N. SEE COLOR AND MATERIAL SCHEDULE AND ROOM FINISH SCHEDULE FOR MORE INFORMATION
REGARDING FINISHES.
O. SEE FURNITURE AND EQUIPMENT PLANS, WALL PROTECTION PLANS, AND SIGNAGE PLANS FOR MORE
INFORMATION REGARDING WALL MOUNTED COMPONENTS.
P. SEE COLOR & MATERIAL SCHEDULE OR "A5 - 3D VIEW - TYPICAL WALL TILE DETAILING" FOR TILE
PATTERN DESIGNATION
A.
B.
C.
D.
E.
F.
G.
ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER BEFORE
PROCEEDING WITH THE WORK.
WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
DETAILS SHOWN ARE TYPICAL UNO. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
SEE STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR GRID UNO. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UNO.
/D2 AE101
P-1 P-2 P-2P-1 P-1 P-1P-2 M1801
A5077
F0220
F2000
F0750 M4040
M1801 F0220F0750
F2000
9.08B
9.09A 9.09A 9.09A
5.43E
5.43E
9.09A
9'- 0"
AF
F
3'- 0"
A5
AI121
Sim
9.09E 9.09E01 01
/D2 AE101
/D2 AE101
M1801F0275 A1015
P-1 P-1
P-1 P-1 P-1
F3200
5.43E 5.43E
9.09A9.09A
P-1 C0025
10.31 10.3110.31
9.09E 9.09E
9.09A
/D2 AE101
M1801
F0275
2'-6 1/16"10'-4 7/16"2'-6 1/16"
GI
VE
N 8'-
4 3 /4"
1/2
GIVEN 12'-11"
9.08F
26.31A
9.08B
/D2 AE101
26.32
12.02
10.31
1'- 6"
AE401
D2
9.08A
/D2 AE101
P-2
P-1
F0305
F0305
F2000
A5212
M0506
/D2 AE101
F2000
F0305
A5077
P-1
P-1 M0506
/D2 AE101
A5077
P-1M0506
2'-
P-1 P-1 A5212
W1 W1
/D2 AE101
P-1P-1
P-1
P-2 M7420
M9066
M8810 A5106
M4255
C4
AI511
D5
AI511
________D4
AI511
6.40B
6.40A
12.22
6.40D
30" 26" 1"FILLER
7'- 0"
RWC-2
TR-2
4'- 6"
/D2 AE101
M1802
F0340
F0004 F0210
F2000
P-1
9.09A
24"
C0025
/D2 AE101
M1802
F0004
F0340
M7420
F3200
P-1
9.09A
P-1
22"
C0025
/D2 AE101
M4255
A5106
M8810
F2000
P-1 P-1 6.40B
6.40D 12.22
6.40A
P-1
10.31
/D2 AE101
F3055
F3200
M1801
F0220
F0750F2000
F0115
P-1
/D2 AE101
P-1 P-1 F0115
M1801
F0220
F0750
F0115
F3200
F2000
/D2 AE101
F2000
F0750
F0220
M1801
F3055
M1801
F0750
F0220
P-2
9.09A
/D2 AE101
F0750
F3055
M1801
F0115
F0115
F0750
F0220
F0220
P-1 P-1 P-1
P-1
/D2 AE101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
A
B
C
D
2 4 5
PhaseDESIGNER OF RECORD A/E:
STAMPCONSULTANTS
MEP:
FARRIS ENGINEERING
12700 WEST DODGE ROAD
OMAHA, NE 68154
402.330.5900
STRUCTURAL:
ERA STRUCTURAL ENGINEERING
110N. ANKENY BLVD. SUITE 200
ANKENY, IA 50023
515.384.1001
6"
6"
6"
6"
ON
E
EI
GH
TH
IN
CH
O
NE
F
OO
T (1
/8"
1' -0
ON
E
QU
AR
TE
R
IN
CH
O
NE
F
OO
T (1
/4"
1' -0
TH
RE
E
EI
GH
TH
S
IN
CH
O
NE
F
OO
T
(3 /8"
1'
-0
ON
E
HA
LF
IN
CH
O
NE
F
OO
T
(1 /2"
1'
-0
TH
RE
E
QU
AR
TE
RS
IN
CH
O
NE
F
OO
T (3
/4"
1' -0
ON
E
IN
CH
O
NE
F
OO
T (1
1'
-0
ON
E
AN
D
ON
E
HA
LF
IN
CH
ES
O
NE
F
OO
T (1
1/ 2"
1'
-0
TH
RE
E
IN
CH
ES
O
NE
F
OO
T
(3
1' -0
32 4 5 61
C:
\U se rs\
A.
Sc hlo me r\D oc um en ts\
W
OM
EN
S
CL
IN
IC
_a utu mn sR
AF
.rv t
/4/
4:
:37
P M
AI402
INTERIOR ELEVATIONS
STONE GROUP ARCHITECTS
117 PIERCE STREET, SUITE 110
SIOUX CITY, IA 51101
(712)252-4014
CONSTRUCT WOMEN'S CLINIC
800 HOSPITAL DRIVE COLUMBIA, MO 65201
06/25/2025 BF/TM AS
SGA #231997
VA #589A4-24-103BID SET
KEYNOTES
KEY VALUE KEYNOTE TEXT
5.43E ALUMINUM HANDRAIL WITH VINYL COVER
6.40A BASE CABINET
6.40B WALL CABINET
6.40D FINISHED END
9.08A 1/4" FIBER REINFORCED LAMINATE.(PL-3).
9.08B 1/2" PHENOLIC INTERIOR WALL PANELING. (PL-2).
9.08F PLASTIC LAMINATE. (PL-4).
9.09A 6" RESILIENT WALL BASE (RB-1)
9.09E 4" HIGH IMPACT CRASH GUARD (CR-1)
10.31 SIGNAGE. SEE SCHEDULE.
12.02 EXISTING FURNITURE
12.22 SOLID SURFACE COUNTERTOP WITH INTEGRAL LAVATORY
26.31A STRIP LIGHTING FIXTURE
26.32 EXISTING LIGHT FIXTURE
1/4" = 1'-0"A1 INT ELEVATION - C1A3 - S
1/4" = 1'-0"A5 INT ELEVATION - C1A3 - W
1/4" = 1'-0"B1 INT ELEVATION - C1A3 - N
1/4" = 1'-0"A4 INT ELEVATION - C1A3 - E
1/4" = 1'-0"B4 INT ELEVATION - C1E33 - S - ENTRY
1/4" = 1'-0"D6 INT ELEVATION - A125 - N
1/4" = 1'-0"D5 INT ELEVATION - A125 - E
1/4" = 1'-0"C5 INT ELEVATION - A125 - S
1/4" = 1'-0"D4 INT ELEVATION - A126 - N
1/4" = 1'-0"C3 INT ELEVATION - A126 - S
1/4" = 1'-0"D3 INT ELEVATION - A126 - E
1/4" = 1'-0"C4 INT ELEVATION - A126 - W
1/4" = 1'-0"D1 INT ELEVATION - A128 - E
1/4" = 1'-0"D2 INT ELEVATION - A128 - N
1/4" = 1'-0"C1 INT ELEVATION - A128 - S
1/4" = 1'-0"C2 INT ELEVATION - A128 - W
REVISION # DESCRIPTION DATE
01 AMENDMENT 01 11/4/2025
1/4" = 1'-0"C6 INT ELEVATION - A125 - W
GENERAL CASEWORK NOTES
H. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.
I. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. BRACKETS TO BE
PAINTED AS SPECIFIED IN THE COLOR AND MATERIAL SCHEDULE.
J. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM CABINETS TO
HAVE PVC EDGES. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR APPROVAL.
K. PROVIDE RESILIENT BASE, PER COLOR AND MATERIAL SCHEDULE, AT ALL BASE CABINETS UNO.
L. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED FOR
COMPLETE INSTALLATION.
M. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.
N. PROVIDE BACKSPASH AND/OR SIDESPLASH AS INDICATED ON INTERIOR ELEVATIONS AND CASEWORK
SECTIONS / DETAILS.
O. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI.
ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.
P. VERIFY ALL GROMMET LOCATIONS AND COUNT WITH OWNER FOLLOWING INSTALLATION OF
SURFACES.
A.
B.
C.
D.
E.
F.
G.
ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION
DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER BEFORE
PROCEEDING WITH THE WORK.
WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE
DRAWINGS.
CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AT THE PROJECT SITE.
ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
DETAILS SHOWN ARE TYPICAL UNO. SIMILAR DETAILS APPLY IN SIMILAR CONDITIONS.
SEE STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
DIMENSIONS ARE TO FACE OF FRAMING, CENTERLINE OF EQUIPMENT, CENTERLINE OF FIXTURE, OR GRID UNO. DIMENSIONS ARE TO FACE OF FINISH ON INTERIOR ELEVATIONS AND/OR WHERE THE
ABBREVIATION "CLR" IS USED UNO.
1" ADJ. SHELVES
SUPPORTED BY 32MM
SYSTEM
MELAMINE FINISH ON
PART. BD., INTERIOR
2x WD. BLOCK'G
AS REQ'D., TYP.
1x WD. BLOCK'G AS
REQ'D., TYP.
1/4" BACK
BASE AS SCHEDULED
PULL, TYP., REF. SPEC.
PULL, TYP., REF. SPEC.
HPDL FINISH ON 3/4"
PART. BD., EXTERIOR
6"
4"
OTHERWISE NOTED IN ELEV.
24" - UNLESS
3"
LOCK WHERE SHOWN ON
ELEVS, REF SPEC, TYP.
R
EF
. E
LE
VA
TI
O N
S 4"
25"
1/
4"
SOLID SURFACE TOP W/
DRIP EDGE ON 3/4"
MARINE GRADE PLYWD
OR MDF & 4"
THERMOFORMED COVED
BACK & SIDE SPLASH W/
TOP EASED EDGE 1
1/ 2"
/D3 AI401
1x WD. BLOCK'G AS REQ'D., TYP.
25"
DASHED LINES REPRESENT
OUTLINE OF ADA CLEARANCE
AND OPEN BOTTOM OF
ENCLOSURE
" M
IN
A
D A
AD
A
9" M
IN
ADA
�11" MIN
1/
2"
1/ 2"
1"
HPDL FRONT APRON ON 3/4"
PART. BD. W/ 3MM EDGE
BANDING
REMOVABLE APRON, HPDL ON 3/4"
PART. BD. W/ 3MM EDGE BANDING;
CLEAT TO ADJ. SURFACES.
FAUCET AND SINK, REF.
PLUMB'G
SOLID SURFACE TOP W/
SQUARE EASED EDGE ON 3/4"
MARINE GRADE PLYWD OR MDF
& 4" THERMOFORMED COVED
BACK & SIDE SPLASH W/ EASED
TOP EDGE
/2
1/
4" 4"
ADA
8" MIN
NO BOTTOM PANEL
NOTE: PROVIDE FINISHED END
PANELS WHEN SIDES ARE EXPOSED
/D3 AI401
PULL, TYP.
MELAMINE FINISH ON
PART. BD., INTERIOR
1" ADJ. SHELVES
SUPPORTED BY
32MM SYSTEM
HPDL FINISH ON 3/4"
PART. BD, EXTERIOR
1x BLOCK'G AS REQ'D
15"
8" R
EF
. E
LE
VA
TI
O
N S
VERTICAL BRACING
HPDL ON 3/4" PART
BD SLOPED TOP
NOTE: SIDE PANELS TO BE ONE FULL
HT PIECE ON EXPOSED ENDS
LOCK, REF. SPEC.,
ONLY WHERE
SPECIFIED IN ELEV.
/C2 AI401
BASE AS SCHEDULED
STAINLESS STEEL
TUBULAR LEGS
STAINLESS STEEL
TABLE WITH INTEGRAL
SINK BACK & SIDE
SPLASH & NO DRIP
EDGE FROM STAINLESS
STEEL MANUFACTURER
INTEGRAL SINK (28" X
16" X 12"D)
1"
3'
1/
2" 1'
0"
1/
4"
FAUCET, BACKSPLASH
MOUNTED, REF PLUMB'G
/B5 AI401
STAINLES STEEL SIDE SPLASH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
A
B
C
D
2 4 5
PhaseDESIGNER OF RECORD A/E:
STAMPCONSULTANTS
MEP:
FARRIS ENGINEERING
12700 WEST DODGE ROAD
OMAHA, NE 68154
402.330.5900
STRUCTURAL:
ERA STRUCTURAL ENGINEERING
110N. ANKENY BLVD. SUITE 200
ANKENY, IA 50023
515.384.1001
6"
6"
6"
6"
ON
E
EI
GH
TH
IN
CH
O
NE
F
OO
T (1
/8"
1' -0
ON
E
QU
AR
TE
R
IN
CH
O
NE
F
OO
T (1
/4"
1' -0
TH
RE
E
EI
GH
TH
S
IN
CH
O
NE
F
OO
T
(3 /8"
1'
-0
ON
E
HA
LF
IN
CH
O
NE
F
OO
T
(1 /2"
1'
-0
TH
RE
E
QU
AR
TE
RS
IN
CH
O
NE
F
OO
T (3
/4"
1' -0
ON
E
IN
CH
O
NE
F
OO
T (1
1'
-0
ON
E
AN
D
ON
E
HA
LF
IN
CH
ES
O
NE
F
OO
T (1
1/ 2"
1'
-0
TH
RE
E
IN
CH
ES
O
NE
F
OO
T
(3
1' -0
32 4 5 61
C:
\U se rs\
A.
Sc hlo me r\D oc um en ts\
W
OM
EN
S
CL
IN
IC
_a utu mn sR
AF
.rv t
/4/
4:
:37
P M
AI511
CASEWORK DETAILS
STONE GROUP ARCHITECTS
117 PIERCE STREET, SUITE 110
SIOUX CITY, IA 51101
(712)252-4014
CONSTRUCT WOMEN'S CLINIC
800 HOSPITAL DRIVE COLUMBIA, MO 65201
06/25/2025 Checker Author
SGA #231997
VA #589A4-24-103BID SET
1 1/2" = 1'-0"D4 SECTION - TYPICAL BASE CABINET W/ DRIP EDGE
1 1/2" = 1'-0"D5 SECTION - TYPICAL SINK ENCLOSURE
REVISION # DESCRIPTION DATE
01 AMENDMENT 01 11/4/2025
1 1/2" = 1'-0"C4 SECTION - WALL CABINET, NO UCL
1 1/2" = 1'-0"C3
SECTION - STAINLESS STEEL TABLE @ SOILED
ROOM
A121
EXAM/TELEHEALTH/CONSULT
A123
RESTROOM
A125
ENTRY/WAITING
A127
MSA CHECK-IN
C1A3
CORRIDOR
A124A
NURSE STATION A124B
INTAKE
A128A
NURSE STATION
A124
RESTROOM
A119
CLEAN
A128
SWAMP
A126
PROCEDURE1
A122
PROCEDURE2
A120
SOILED
TRUE
NORTH
PLAN
NORTH
1/2" DCW
P-528
P-408
1/2" DCW
1/2" DHW
1 1/2" DCW
1" DCW
1" DHW (E)
2" V (E)
2" V (E)
2" V (E)
2" V (E)
2" V (E)
1 1/2" DCW (E)
1" DHW (E)
1" RHW (E)
2" V (E)
2" V (E)
1 1/2" DCW (E)
1" DHW (E)
1" RHW (E)
P-528
P-408
1/2" DHW
1 1/2" DCW
2" V
1 1/2" V
2" V
P-528
2" V
1 1/2" V
2" V (E)
(E)
(E)
P-101
P-101
A128A
TLT.
3/4" DHW
1 1/2" DCW
2" V (E)
3/4" DHW
3/4" DCW
3/4" RHW
2" V (E)
3/4" DCW3/4" DHW
1" DHW
1/2" RHW
1 1/2" V
EC
5" ST (E)
5" ST (E)
DN
UP
WHA - 1
WHA - 1
2" V (E)
2" V (E)
S
S
2" V
1 1/2" V
1/2" DCW
DS
P-529
1 1/2" V
1 1/2" V
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
A
B
C
D
2 4 5
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANTS
MEP:
FARRIS ENGINEERING
12700 WEST DODGE ROAD
OMAHA, NE 68154
402.330.5900
STRUCTURAL:
ERA STRUCTURAL ENGINEERING
110N. ANKENY BLVD. SUITE 200
ANKENY, IA 50023
515.384.1001
6"
6"
6"
6"
O N
E E
IG
H
T H
I N
C H
O
N E
F O
O T
1/
8"
'-0
O
N E
Q U
A R
T E
R I
N C
H
O N
E F
O O
T
1/ 4"
'-0
T H
R E
E E
IG
H
T H
S
IN
C H
O
N E
F O
O T
(3 /8
1' -0
O
N E
H A
LF
I
N C
H
O N
E F
O O
T
1/ 2"
'-0
T H
R E
E Q
U A
R T
E R
S
IN
C H
O
N E
F O
O T
3/
4"
'-0
O
N E
I N
C H
O
N E
F O
O T
1"
'-0
O N
E A
N D
O N
E H
A
LF
I N
C H
E S
O
N E
F O
O T
1/ 2"
'-0
T H
R E
E
IN
C H
E S
O
N E
F O
O T
3"
'-0
32 4 5 61
06/24/2025
C :\U se rs
\d ll\
R ev it Lo ca l F ile s\
M E
P F
C en tr al
-2 3_ dl et ch er
G C
4C K
.r vt
/4
/2
4:
:4
P
M
PL101
FIRST FLOOR PLUMBING PLAN
STONE GROUP ARCHITECTS
117 PIERCE STREET, SUITE 110
SIOUX CITY, IA 51101
(712)252-4014
CONSTRUCT WOMEN'S CLINIC
800 HOSPITAL DRIVE COLUMBIA, MO 65201
06/24/2025 DOV DLL
SGA #231997
VA #589A4-24-103
BID SET
FIRST LEVEL KEY PLAN
N
KEYNOTES
1 CUT EXISTING PIPE AS CLOSE TO THE EXISTING MAIN AS POSSIBLE AND INSTALL NEW PIPE CAPS AT
CONNECTION POINT WHERE PIPING IS TO BE REMOVED.
2 CUT OUT A SECTION OF EXISTING PIPING TO INSTALL NEW TEE FITTINGS.
3 EXTEND NEW PIPE OF LIKE MATERIAL TO EXISTING PIPE AT CONNECTION POINTS.
4 PROVIDE UL LISTED ASSEMBLY FOR ALL PIPING PASSING THROUGH NEW WALL.
5 CUT EXISTING PIPE AND INSTALL NEW PIPE CAPS AT CONNECTION POINT WHERE PIPING IS TO BE
REMOVED.
7 EXTEND 1/2" DCW DOWN AND CONNECT TO NEW LAVATORY.
8 1/2" DCW AND 1/2" DHW DOWN TO NEW SINKS.
9 AUTOFLOW VALVE. SET TO 0.5 GPM. REFER TO DETAIL #1/P-701, TYPICAL.
10 WHA-1 IN CEILING WITH ACCESS PANEL. IF NOT ABLE TO LOCATE IN THE CEILING, INSTALL IN THE
WALL WITH ACCESS PANEL.
11 REFER TO DETAIL #2/P-701. TYPICAL OF ALL NEW PIPE INSTALLATION IN WORK AREA OUTLINED.
1/4" = 1'-0"
FIRST FLOOR PLUMBING PLAN
REVISION # DESCRIPTION DATE
1 Amendment 01 11/04/2025
PLUMBING FIXTURE GENERAL NOTES
A. PLUMBING FIXTURES SHALL BE OF ONE OF THE MANUFACTURER'S INDICATED AND IN
ACCORDANCE WITH THE INFORMATION AND MANUFACTURER'S CATALOG NUMBERS
INDICATED. WHERE MANUFACTURER'S CATALOG NUMBERS HAVE BEEN UPDATED OR
DELETED, FIXTURES SHALL BE OF SIMILAR CONFIGURATION AND OF SIMILAR OR BETTER
QUALITY THAN THAT INDICATED.
B. VERIFY ALL MOUNTING HEIGHTS OF PLUMBING FIXTURES PRIOR TO ORDERING EQUIPMENT.
MOUNTING HEIGHTS SHALL BE AS INDICATED ON ARCHITECTURAL DRAWINGS AND COMPLY
WITH ADA REQUIREMENTS.
C. VERIFY FIXTURE COLORS WITH ARCHITECT PRIOR TO ORDERING EQUIPMENT.
D. FOR ALL COUNTERTOP SINKS, CONTRACTOR SHALL COORDINATE WITH CABINET WORK TO
INSURE THAT THE SINK WILL FIT IN CABINET PRIOR TO ORDERING FIXTURE.
E. FIXTURE DRAWINGS DEPICTED MAY NOT NECESSARILY BE AN ACCURATE DEPICTION OF
ACTUAL MODELS DUE TO RECENT PRODUCT UPDATES.
F. ALL FIXTURE STOPS SHALL BE LOOSE KEY.
1 1/2" DCW (E)
1 1/2" DCW (E)
1 1/2" DCW (E)
1" DHW (E)
1" RHW (E)
1 1/2" DCW (E)
1" DHW (E)
1" RHW (E)
1" RHW (E)
1" DHW (E)
3/4" DCW
3/4" DHW
3/4" RHW
1/2" DCW
1/2" DHW
1/2" DCW
1/2" DHW
P-528
WHA - 1
WHA - 1
1" DCW
1/2" DHW
1/2" DCW
P-101 P-408
P-528
P-101
P-528
1/2" DCW
1/2" DHW
1/2" RHW
1/2" RHW
1 1/2" DCW
1" DHW
1" DCW
1/2" DHW
1/2" DCW
1/2" RHW
1/2" DCW
1/2" DHW
P-408TO P-529
8" SAN (E)
6" SAN (E)
LOCATED IN CRAWLSPACE
4" SAN (E)
4" SAN (E)
2" SAN (E)
1 1/2" V (E)
2" V (E)
2" V (E)
4" SAN (E)
4" SAN (E)
2" V (E)
2" SAN (E)
2" V (E)
2" SAN (E)
TO EXISTING SINK
TO P-529 SINK
P-528
P-528
P-408
P-101
P-528P-408
P-101
WC(E)
2" V (E)
4" V (E)
2" V (E)
2" V (E)
2" V (E)
2" V (E)
4" SAN (E)
4" SAN (E)
2" V (E)
2" V (E)
4"VTR(E)
4"VTR(E)
2" V (E)
EC(NEW)
2" V (E)
2" V (E)
CO
SANITARY LOCATED
IN CEILING OF THE
BASEMENT
SANITARY LOCATED
IN CEILING OF THE
BASEMENT
2" V (E)
2" V (E)
2" V (E)
2" V
2" V
1 1/2" V
1 1/2" V
1 1/2" SAN
1 1/2" SAN
2" V
1 1/2" V1 1/2" V
1 1/2" SAN
4" SAN
4" SAN
2" SAN
2" V
2" V (E)
2" SAN (E)
6" SAN (E)
6" SAN (E)
2" SAN (E)
TO EXISTING SINK
TO EWC(E)
S
S
S
S
VENTS LOCATED
IN CEILING OF THE
FIRST FLOOR
VENTS LOCATED
IN CEILING OF THE
FIRST FLOOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
A
B
C
D
2 4 5
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANTS
MEP:
FARRIS ENGINEERING
12700 WEST DODGE ROAD
OMAHA, NE 68154
402.330.5900
STRUCTURAL:
ERA STRUCTURAL ENGINEERING
110N. ANKENY BLVD. SUITE 200
ANKENY, IA 50023
515.384.1001
6"
6"
6"
6"
O N
E E
IG
H
T H
I N
C H
O
N E
F O
O T
1/
8"
'-0
O
N E
Q U
A R
T E
R I
N C
H
O N
E F
O O
T
1/ 4"
'-0
T H
R E
E E
IG
H
T H
S
IN
C H
O
N E
F O
O T
(3 /8
1' -0
O
N E
H A
LF
I
N C
H
O N
E F
O O
T
1/ 2"
'-0
T H
R E
E Q
U A
R T
E R
S
IN
C H
O
N E
F O
O T
3/
4"
'-0
O
N E
I N
C H
O
N E
F O
O T
1"
'-0
O N
E A
N D
O N
E H
A
LF
I N
C H
E S
O
N E
F O
O T
1/ 2"
'-0
T H
R E
E
IN
C H
E S
O
N E
F O
O T
3"
'-0
32 4 5 61
06/24/2025
C :\U se rs
\d ll\
R ev it Lo ca l F ile s\
M E
P F
C en tr al
-2 3_ dl et ch er
G C
4C K
.r vt
/4
/2
4:
:4
P
M
P-601
PLUMBING DIAGRAMS
STONE GROUP ARCHITECTS
117 PIERCE STREET, SUITE 110
SIOUX CITY, IA 51101
(712)252-4014
CONSTRUCT WOMEN'S CLINIC
800 HOSPITAL DRIVE COLUMBIA, MO 65201
06/24/2025 DOV DLL
SGA #231997
VA #589A4-24-103
BID SET
CONTRACTOR SHALL BE RESPONSIBLE TO REVIEW ALL
DRAWINGS TO IDENTIFY WORK THAT MAY BE REQUIRED
DUE TO EQUIPMENT OR OMITTED WORK. CONTRACTOR
IS RESPONSIBLE FOR ANYTHING IN EQUIPMENT
SCHEDULE AND ON DRAWINGS THAT ARE IDENTIFIED AS
REQUIRED PLUMBING. DRAWINGS ARE BASED ON A
BASIS OF DESIGN (BOD), ANY CHANGES REQUIRED AS A
RESULT OF AN ITEM BEING INSTALLED THAT WAS NOT
BOD SHALL NOT BE AT ANY COST TO THE GOVERNMENT.
CHANGES SHALL BE DOCUMENTED AND "RED LINES"
PROVIDED TO AE/COR AS SOON AS POSSIBLE TO
ENSURE ALL OTHER WORKS ARE/CAN BE COORDINATED
ACCORDINGLY.
PLUMBING ISOMETRIC DOMESTIC WATER
PLUMBING ISOMETRIC SAN & VENT
EC(N)
REVISION # DESCRIPTION DATE
1 Amendment 01 11/04/2025
PLUMBING FIXTURE/EQUIPMENT CONNECTION SCHEDULE
MARK FIXTURE TYPE
MINIMUM CONNECTION SIZE
REMARKS
WASTE (IN) VENT (IN) HOT WATER (IN) COLD WATER (IN)
P-101 WATER CLOSET FLOOR MOUNTED 4" 2" - 1" 1
P-408 LAVATORY UNDERMOUNT 1 1/2" 1 1/2" 1/2" 1/2" 1
P-528 SINK SINGLE COMPARTMENT 1 1/2" 1 1/2" 1/2" 1/2" 1
P-529 SINK INTEGRAL 1-1/2" 1-1/2" 1/2" 1/2" 1
WHA
WATER HAMMER
ARRESTOR
SEE PLANS - - - - 1
REMARKS:
1. SIZE LISTED ON SCHEDULES APPLY TO ALL FIXTURES ON PROJECT UNLESS OTHERWISE NOTED.
PLUMBING FIXTURE GENERAL NOTES
A. PLUMBING FIXTURES SHALL BE OF ONE OF THE MANUFACTURER'S INDICATED AND IN
ACCORDANCE WITH THE INFORMATION AND MANUFACTURER'S CATALOG NUMBERS
INDICATED. WHERE MANUFACTURER'S CATALOG NUMBERS HAVE BEEN UPDATED OR
DELETED, FIXTURES SHALL BE OF SIMILAR CONFIGURATION AND OF SIMILAR OR BETTER
QUALITY THAN THAT INDICATED.
B. VERIFY ALL MOUNTING HEIGHTS OF PLUMBING FIXTURES PRIOR TO ORDERING EQUIPMENT.
MOUNTING HEIGHTS SHALL BE AS INDICATED ON ARCHITECTURAL DRAWINGS AND COMPLY
WITH ADA REQUIREMENTS.
C. VERIFY FIXTURE COLORS WITH ARCHITECT PRIOR TO ORDERING EQUIPMENT.
D. FOR ALL COUNTERTOP SINKS, CONTRACTOR SHALL COORDINATE WITH CABINET WORK TO
INSURE THAT THE SINK WILL FIT IN CABINET PRIOR TO ORDERING FIXTURE.
E. FIXTURE DRAWINGS DEPICTED MAY NOT NECESSARILY BE AN ACCURATE DEPICTION OF
ACTUAL MODELS DUE TO RECENT PRODUCT UPDATES.
F. ALL FIXTURE STOPS SHALL BE LOOSE KEY.
(INSTALL PER A.D.A. REQUIREMENTS)
FIXTURE
20" x 18", VITREOUS CHINA, WALL HUNG LAVATORY (COMPLIES WITH ADA) WITH BACK, PUNCHED FOR
CONCEALED ARM CARRIER, ANTI-SPLASH RIM AND FRONT OVERFLOW.
AMERICAN STANDARD "LUCERNE" 0355.012.
TRIM
CHROME PLATED BRASS, HARDWIRED, SENSOR OPERATED, 4" CENTER-SET ELECTRONIC HAND
WASHING FAUCET, 0.5 GPM (1.9 LPM) VANDAL RESISTANT LAMINAR FLOW SPRAY, 8" TRIM PLATE, ADA
COMPLIANT, CAST BRASS, 24 VAC, TROUBLESHOOTING LED INDICATOR LIGHTS, BELOW DECK
THERMOSTATIC MIXING VALVE, METAL JACKETED WIRE PROTECTION FOR SENSOR LEAD AND 120 VAC/24
VAC TRANSFORMER (BOX MOUNT). COORDINATE ELECTRICAL CONNECTIONS WITH ELECTRICAL
CONTRACTOR.
THERMOSTATIC MIXING VALVE: SOLID BRASS CONSTRUCTION, CORROSION RESISTANT INTERNAL COMPONENTS, INTEGRAL CHECKS WITH SCREENS AND ADJUSTABLE TEMPERATURE SELECTION WITH
LOCK NUT TO PREVENT TAMPERING.
SLOAN OPTIMA ETF-600-8-BOX-BDT-CP-0.50GPM-MLM-IR-BT-FCT (ETF-1024-A), POWERS E480 MIXING
VALVE.
COMPLETE WITH SOLID BRASS STOPS WITH ALL BRASS STEMS AND CHLORAMINE-CHLORINE RESISTANT WASHERS. CHLORAMINE-CHLORINE RESISTANT BRAIDED STAINLESS STEEL OR POLYMER FLEXIBLE CONNECTORS. CAST BRASS SOLID TOP OPEN GRID OFFSET P.O. PLUG WITH 6" 17 GAUGE TAILPIECE WITH CAST BRASS LOCKNUT. HEAVY CAST BRASS ADJUSTABLE P-TRAP WITH 17 GA TUBULAR WALL
BEND AND BRASS SLIP NUTS. (ALL BRASS MATERIALS SHALL BE CHROME PLATED)
PROVIDE TRUEBRO "LAV GUARD2" MODEL #103 E-Z.
CARRIER
FOR BLOCK WALL CONSTRUCTION:
WALL-MOUNT, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING SCREWS
AND ADJUSTABLE WALL PLATE.
SEE SPECIFICATIONS FOR APPROVED MANUFACTURERS.
VERIFY WALL THICKNESS PRIOR TO ORDERING CARRIER(S).
FOR STUD WALL CONSTRUCTION:
FLOOR-MOUNT, SINGLE LAVATORY CARRIER WITH CONCEALED ARMS, LEVELING AND SECURING
SCREWS, STRUCTURAL UPRIGHTS AND BLOCK BASES.
SEE SPECIFICATIONS FOR APPROVED MANUFACTURERS.
VERIFY WALL THICKNESS PRIOR TO ORDERING CARRIER(S).
LAVATORY: P-408
FIXTURE
SINGLE COMPARTMENT, 18 GAUGE 304 STAINLESS STEEL, DROP IN SINK, SINGLE CENTER HOLE.
OVERALL DIMENSIONS: 15" LONG X 17-1/2" WIDE
BOWL DIMENSIONS: 12" LONG X 12" WIDE X 4-7/8" DEEP
ELKAY LUSTERTONE M#LRAD151750.
TRIM
CHROME PLATED BRASS, HARDWIRED, SENSOR OPERATED, ELECTRONIC HAND WASHING 5-7/8" RIGID GOOSENECK FAUCET, 5-11/32" OUTLET HEIGHT, 1.5 GPM (6.0 LPM) VANDAL RESISTANT LAMINAR FLOW SPRAY, 4" TRIM PLATE, ADA COMPLIANT, CAST BRASS, 24 VAC, TROUBLESHOOTING LED INDICATOR LIGHTS, METAL JACKETED WIRE PROTECTION FOR SENSOR LEAD AND 120 VAC/24 VAC TRANSFORMER (BOX
MOUNT). COORDINATE ELECTRICAL CONNECTIONS WITH ELECTRICAL CONTRACTOR. PROVIDE WITH
THERMOSTATIC MIXING VALVE.
SLOAN OPTIMA EAF-700-BOX-CP-1.5GPM-LAM-IR-IQ-FCT.
COMPLETE WITH SOLID BRASS STOPS WITH ALL BRASS STEMS AND CHLORAMINE-CHLORINE RESISTANT WASHERS, CHLORAMINE-CHLORINE RESISTANT BRAIDED STAINLESS STEEL FLEXIBLE CONNECTORS (SUPPLY TUBES), STAINLESS STEEL BASKET STRAINER WITH STAINLESS STEEL BASKET, CAST BRASS LOCK AND COUPLING NUTS, BRASS 4" 17 GAUGE TAILPIECE, HEAVY CAST BRASS ADJUSTABLE P-TRAP WITH 17 GAUGE TUBULAR WALL BEND AND BRASS ESCUTCHEONS. (ALL BRASS MATERIALS SHALL BE CHROME
PLATED)
SINK: P-528
FIXTURE
SHOCK ABSORBER WITH STAINLESS STEEL SHELL, HYDRO-PNEUMATIC CUSHION OF ARGON GAS AND PURE GLYCERINE, ELASTOMER, BELLOWS, STAINLESS STEEL ADAPTER AND MALE THREADED PLUG.
J.R. SMITH SERIES 5000.
WATER HAMMER ARRESTER: WHA-1
FLOW
PIPE FROM SYSTEM
SEE PLANS FOR
CONTINUATION
AUTOMATIC FLOW BALANCING
VALVE SIZED FOR GPM SHOWN
ON PLANS (TYP.)
PIPE TO SYSTEM
SEE PLANS FOR
CONTINUATION
NIPPLE (TYP.) BALL VALVE (TYP.)
FLOW
NOTE: PROVIDE AND INSTALL B-LINE OR ACCEPTABLE INSULATED
GALVANIZED STEEL JACKET AND HANGER, STRUT MOUNTED CLAMP AND
PIPE SUPPORT LOCATIONS.
CLEVIS HANGER
PIPE
PIPE INSULATION
PIPE
PIPE INSULATION
PIPE SHIELD
PIPE CLAMP
PIPE SHIELD
STRUT HANGER
CONNECTION SIZE
WASTE: 4" | VENT: 2" | DCW: 1" | DHW: -
FIXTURE
ELONGATED FLOOR MOUNT VITREOUS CHINA SIPHON JET WATER CLOSET, LOW CONSUMPTION (6.0 LPF/1.6 GPF) FULLY GLAZED 2" BALLPASS TRAPWAY, 11" x 13" WATER SURFACE, 1-1/2" TOP SPUD, AND
BOLT CAPS.
AMERICAN-STANDARD "MADERA" 16-1/2" RIGHT HEIGHT MODEL NO. 3641.001 OR APPROVED EQUAL.
(SHALL COMPLY WITH A.D.A. REQUIREMENTS)
KOHLER "HIGHCLIFF ULTRA" MODEL NO. K-96057 16-5/8" UNIVERSAL HEIGHT OR APPROVED EQUAL.
(SHALL COMPLY WITH A.D.A. REQUIREMENTS)
TRIM
EXPOSED, 1.6 GPF, QUIET, DIAPHRAGM TYPE, CHROME PLATED CLOSET FLUSHOMETER. DUAL FILTERED
BY-PASS DIAPHRAGM, STOP SEAT, AND VACUUM BREAKER, SHALL BE CHLORAMINE RESISTANT
MATERIALS. ADA COMPLIANT METAL NON-HOLD-OPEN HANDLE, 1" I.P.S. SCREWDRIVER BAK-CHEK ANGLE STOP, FREE SPINNING VANDAL RESISTANT STOP CAP, ADJUSTABLE TAILPIECE, SPUD COUPLING AND
FLANGE, SWEAT SOLDER ADAPTER WITH COVER TUBE AND CAST SET SCREW WALL FLANGE.
SLOAN ROYAL MODEL NO. 111-1.6-DFB OR APPROVED EQUAL.
COMMERCIAL WEIGHT SOLID PLASTIC OPEN FRONT LESS COVER FOR ELONGATED BOWL. LARGE
INTEGRAL BUMPER SHALL BE COLOR-MATCHED MOLDED PLASTIC. HINGES TO FEATURE EXTERNAL CHECK
AND INTERNAL SELF-SUSTAINING MECHANISMS IN BOTH HINGES. COLOR TO BE WHITE.
CHURCH MODEL NO. 295SSCT OR APPROVED EQUAL.
COMPLETE WITH BRASS CLOSET BOLTS, AND BOWL WAX.
WATER CLOSET: P-101
CONNECTION SIZE
DCW: 1/2" | DHW: 1/2" | W: 1-1/2" | V: 1-1/2"
FAUCET TRIM
WORKBOARD SINK FAUCET FOR HOT AND COLD WATER, BACKSPLASH
MOUNTED WITH 4" FIXED CENTERS, CHROME PLATED. L-TYPE
SWING SPOUT, 9-1/2" CENTER-TO-CENTER. 1.5 GPM (5.7 L/MIN)
PRESSURER COMPENSATING SOFTFLO AERATOR. 4" METAL,
VANDAL-PROOF, WRIST BLADE HANDLES WITH SIXTEEN POINT,
TAPERED BROACH AND SECURE BLUE AND RED INDEX BUTTONS.
CERAMIC QUARTER-TURN CARTRIDGE, FEATURES SQUARE,
TAPERED STEM. 1/2" NPSM SUPPLY INLETS. ECAST CONSTRUCTION
WITH LESS THAN 0.25% LEAD CONTENT BY WEIGHTED AVERAGE.
CALGREEN COMPLIANT. THIS PRODUCT MEETS ADA ANSI1CC A117.1
REQUIREMENTS AND IS TESTED AND CERTIFIED TO INDUSTRY
STANDARDS: ASME A122.18.1/CSA B125.1. CERTIFIED TO NSF/ANSI 61,
SECTION 9, CALIFORNIA HEALTH AND SAFETY CODE 116875 (AB1953-
2006), VERMOUNT BILL S.152, NFS/ANSI 372 LOW LEAD CONTENT,
AND CALIFORNIA GREEN BUILDING STANDARD CODE (CALGREEN).
PROVIDE WITH THERMOSTATIC MIXING VALVE.
RATED OPERATING PRESSURE: 20-125 PSI
RATED OPERATING TEMPERATURE: 40-140°F
SINK
STAINLESS STEEL COUNTERTOP WITH INTEGRAL SINK. 14 GAUGE, TYPE 304 STAINLESS STEEL, BOX MARINE FRONT EDGE, 12" BACKSPLASH AND 12" SIDESPLASH, STAINLESS STEEL BULLET FEET.
OVERALL DIMENSIONS" 72"W X 25"D.
INTEGRAL SINGLE COMPARTMENT SINK
OVERAL DIMENSTIONS 28"W X 12"D X 16"H ID.
COMPLETE WITH SOLID BRASS STOPS WITH ALL BRASS STEMS AND CHLORAMINE-CHLORINE
RESISTANT WASHERS, CHLORAMINE-CHLORINE RESISTANT BRAIDED STAINLESS STEEL FLEXIBLE CONNECTORS (SUPPLY TUBES), STAINLESS STEEL BASKET STRAINER WITH STAINLESS STEEL BASKET, CAST BRASS LOCK AND COUPLING NUTS, BRASS 4" 17 GAUGE TAILPIECE, HEAVY CAST BRASS
ADJUSTABLE P-TRAP WITH 17 GAUGE TUBULAR WALL BEND AND BRASS ESCUTCHEONS. (ALL BRASS
MATERIALS SHALL BE CHROME PLATED)
SINK: P-529
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
A
B
C
D
2 4 5
Phase
DESIGNER OF RECORD
A/E:
STAMPCONSULTANTS
MEP:
FARRIS ENGINEERING
12700 WEST DODGE ROAD
OMAHA, NE 68154
402.330.5900
STRUCTURAL:
ERA STRUCTURAL ENGINEERING
110N. ANKENY BLVD. SUITE 200
ANKENY, IA 50023
515.384.1001
6"
6"
6"
6"
O N
E E
IG
H
T H
I N
C H
O
N E
F O
O T
1/
8"
'-0
O
N E
Q U
A R
T E
R I
N C
H
O N
E F
O O
T
1/ 4"
'-0
T H
R E
E E
IG
H
T H
S
IN
C H
O
N E
F O
O T
(3 /8
1' -0
O
N E
H A
LF
I
N C
H
O N
E F
O O
T
1/ 2"
'-0
T H
R E
E Q
U A
R T
E R
S
IN
C H
O
N E
F O
O T
3/
4"
'-0
O
N E
I N
C H
O
N E
F O
O T
1"
'-0
O N
E A
N D
O N
E H
A
LF
I N
C H
E S
O
N E
F O
O T
1/ 2"
'-0
T H
R E
E
IN
C H
E S
O
N E
F O
O T
3"
'-0
32 4 5 61
06/24/2025
C :\U se rs
\d ll\
R ev it Lo ca l F ile s\
M E
P F
C en tr al
-2 3_ dl et ch er
G C
4C K
.r vt
/4
/2
4:
:4
P
M
P-701
PLUMBING SCHEDULES - FIXTURES - DETAILS
STONE GROUP ARCHITECTS
117 PIERCE STREET, SUITE 110
SIOUX CITY, IA 51101
(712)252-4014
CONSTRUCT WOMEN'S CLINIC
800 HOSPITAL DRIVE COLUMBIA, MO 65201
06/24/2025 DOV DLL
SGA #231997
VA #589A4-24-103
BID SET
NOT TO SCALE
1 BALANCE VALVE DETAIL
NOT TO SCALE
2 PIPE SUPPORT INSULATION DETAIL
CONTRACTOR SHALL BE RESPONSIBLE TO REVIEW ALL
DRAWINGS TO IDENTIFY WORK THAT MAY BE REQUIRED
DUE TO EQUIPMENT OR OMITTED WORK. CONTRACTOR
IS RESPONSIBLE FOR ANYTHING IN EQUIPMENT
SCHEDULE AND ON DRAWINGS THAT ARE IDENTIFIED AS
REQUIRED PLUMBING. DRAWINGS ARE BASED ON A
BASIS OF DESIGN (BOD), ANY CHANGES REQUIRED AS A
RESULT OF AN ITEM BEING INSTALLED THAT WAS NOT
BOD SHALL NOT BE AT ANY COST TO THE GOVERNMENT.
CHANGES SHALL BE DOCUMENTED AND "RED LINES"
PROVIDED TO AE/COR AS SOON AS POSSIBLE TO
ENSURE ALL OTHER WORKS ARE/CAN BE COORDINATED
ACCORDINGLY.
REVISION # DESCRIPTION DATE
1 Amendment 01 11/04/2025