36C25523R0123.docx
DOCX document 16 KB Posted
- Attached to
- Z1DA--657-21-117JB (A) Correct Deficiencies Identified During Triennial Testing (VA-23-00098255)
- Solicitation number
- 36C25523R0123
About this file
This presolicitation notice provides details for project Z1DA-657-21-117JB(A) to correct deficiencies identified during triennial testing at the St. Louis VAMC. The scope of work includes replacing electrical panels and other components in multiple buildings to address issues found in the FY2019 testing as delineated in the plans and specifications. Protective covers or cages also must be installed on sprinkler heads and water lines near electrical equipment to prevent water damage per NEC guidelines. The solicitation number is 36C25523R0123 and responses are due by August 15, 2023 at 10:00 AM Central Time. The contracting office is the VA Network Contracting Office in Leavenworth, KS and the estimated value makes it a SDVOSBC set-aside.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Phase 1 Vol 2.pdf | ||
| Phase 1 Vol 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Presolicitation Notice Presolicitation Notice
| SUBJECT* |
| 657-21-117JB (A) Correct Deficiencies Identified During Triennial Testing (VA-23-00098255) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 66048 |
| SOLICITATION NUMBER* |
| 36C25523R0123 |
| RESPONSE DATE/TIME/ZONE |
| 08-15-2023 10:00 CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| Z1DA |
| NAICS CODE* |
| 238210 |
| PLACE OF PERFORMANCE |
| St. Louis VAMC |
1 Jefferson Barracks Rd
St. Louis MO
| POSTAL CODE |
| 63125 |
| COUNTRY |
| USA |
CONTACT INFORMATION
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office (NCO) 15 3450 S 4th Street Trafficway
Leavenworth KS 66048
POINT OF CONTACT*
Contracting officer Jennifer Sotomayor Jennifer.Sotomayor@va.gov
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
657-21-117JB – Correct Deficiencies Identified During Triennial Testing 8-3-2023 Scope of Work (See Plans and Specifications for the full Scope of Work)
1. The Construction firm must provide construction services as delineated in the Plans and Specifications. The following deficiencies below were identified during the FY2019 Triennial Electrical Testing required under VHA Directive 1028. This project will correct deficiencies remaining after testing. New equipment shall have all the required working clearances.
A. Building 1 – Replacement of panels per plans and specifications.
B. Building 3 –Replace Panel P3 in Basement Mechanical Room 001. Provide NEMA 3R, and misc per plans and specifications.
C. Building 18 – Replace panel(s) per plans and specifications.
D. Building 24 – Replace panels in Ground Floor Kitchen Room G06 per plans and specifications.
E. Building 25 – replace panels per plans and specifications.
F. Building 51A – Replace other issues per plans and specifications.
G. Building 53 - Replace other issues per plans and specifications.
H. The majority of electrical equipment in this facility has sprinkler heads, related water pipes and drainpipes directly over or within the spray pattern of the electrical equipment as represented by the picture to the right. Install protective covers to prevent water from getting into the electrical equipment nor are physical protective devices installed to protect the actual sprinkler heads from physical damage. Both are required by National Electric Code section 110.26(F)(1)(a) through (F)(1)(d). Shields need to be installed in all areas where electrical components are within the spray pattern or have overhead water lines to prevent damage to prevent overhead water sources (sprinklers and water lines) from penetrating the enclosures. Such penetration could lead to a potentially catastrophic failure. Protective covers or cages need to be installed on unprotected sprinkler heads to prevent accidental activation with the same potential for catastrophic failure as mentioned above per plans and specifications.
See attached document: Phase 1 Vol 1.
See attached document: Phase 1 Vol 2.