36C25520R0007-006.pdf
PDF Posted
- Attached to
- 589-CA3-369, Renovate Emergency Room Phase 2 B
- Solicitation number
- 36C25520R0007
About this file
This solicitation package describes requirements for renovating an emergency department phase at the Kansas City VA Medical Center. Work includes general construction and renovations to existing space totaling approximately 1,250 square feet. The renovated space will include three new treatment rooms, a nourishment room, bio-med closet, shower/toilet facility, and electrical room. Headwalls and medical equipment will be provided. Electrical, mechanical, plumbing, and fire protection work is also included. The project completion period is estimated at 180 calendar days. The estimated cost range is $500,000 to $1,000,000. The solicitation will be issued on or about December 3, 2019 as a total small business set-aside for SDVOSBs under NAICS 236220. Proposals are due on or about January 17, 2020.
36C25520R0007 589-369 ER PH2 Drawings_Part3_Part1 (8 Sheets).pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25520R0007-0003000.docx | DOCX document | |
| 36C25520R0007-0002000.docx | DOCX document | |
| 36C25520R0007-0002001.pdf | ||
| 36C25520R0007-0001001.pdf | ||
| 36C25520R0007-0001000.docx | DOCX document | |
| 36C25520R0007-004.pdf | ||
| 36C25520R0007-007.pdf | ||
| 36C25520R0007-003.pdf | ||
| 36C25520R0007-002.pdf | ||
| 36C25520R0007-005.pdf | ||
| 36C25520R0007-001.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
C1-63A
VESTIBULE
C1-63A
CORRIDOR
C1-62C
CORRIDOR
V1-673
OFFICE
SUPERVISOR
V1-671
STAFF LOCKER/
LOUNGE
V1-671A
BIOMED
NETWORK
CLOSET
V1-675
OFFICE
V1-675B
ARMORY &
EVIDENCE
ROOM
OFFICE
V1-675A
VA POLICE
V1-683
ADMISSIONS
V1-654
TRIAGE
STATION 2
V1-650
ED 11
V1-652
ED 12
V1-687
ADMISSIONS
V1-642B
TOILET
V1-642C
TOILET
C1-62A
CORRIDOR
EXISTING
SHAFT
TO
REMAIN
G'
G1'
H'
J'
F'
E'
E F
E C
PARTIAL FIRST FLOOR PLAN-MED GAS DEMOLITION
SCALE: 1/4"= 1' 0"
1. REMOVE ALL EXISTING ABANDONED MEDICAL AIR, VACUUM, AND OXYGEN PIPING BACK
TO POINT OF CONNECTION. CAP REMAINING PIPING AS REQUIRED.
2. EXISTING ZONE VALVE CONTROL BOX TO BE REMOVED AND RETAINED FOR
RE-INSTALLATION. PREPARE REMAINING PIPING FOR RECONNECTION, RE: NEW WORK.
FLOOR PLAN NOTES
##P
N
M
A
M
V
O
MA
MV
O
MA
MV
O
MA
MV
O
01P
(TYP)
01P
(TYP)
02P
ZVC
AAP-1C
1" M
V
1/2" O
ZVC
AAP-1A
AAP-1B
1/ 2"
O 1/
2" M
A
M
V 1/
2" O
1/ 2"
M A
3/4" MV
1/2" O
1/2" MA
3/4" MV
1/2" O
1/2" MA
1" M
V 1/
2" O
3/ 4"
M A
3/ 4"
M V
1/ 2"
O 1/
2" M
A
1" M
V 1/
2" O
3/ 4"
M A
1" M
V 1/
2" O
1/ 2"
M A
3/4" MV
1/2" O
1/2" MA
3/4" MV
1/2" O
1/2" MA
1" MV
1/2" O
3/4" MA
1" M
V 1/
2" O
1/ 2"
M A
1" MV
1/2" O
1/2" MA
1 1/4" MV
1/2" O
3/4" MA
1" MV
1/2" MA
1" MV
1/2" O
3/4" MA
6A 72' 3' 4'3.9' 4.2'
E'
F'
G'
G1'
H'
J'
Lankford Fendler a s s o c i a t e s
BLDG 26
BLDG 1
BLDG
PHASE II
N
Revisions
Drawing Name: P:\18.5800\18.5833.00_KCVAMC-Emergency Dept-Remodel Phase II\Drawings\PHASE 2 DRAWINGS\18.5833.00PD201.dwg Jul 25,2019 - 5:01pm
Date
Drawing Title:
Scale:
Approved:
Sheet of
Building Number:
Location:
Project Title:
Checked By:
DRAWING NO.
Project No.
Drawn By:
Date:
D e p a r t m e n t o f
V e t e r a n s
A f f a i r s
589-396
CONSULTANTS:ARCHITECT:
8/10/2018
EMERGENCY ROOM EXPANSION, PHASE IIB
KANSAS CITY VA MEDICAL CENTER
4801 Linwood Blvd
Kansas City , MO 64128
Kansas City VA Medical Center
4801 Linwood Blvd, Kansas City, MO 64128
95% DESIGN REVIEW 05/31/2018
STRUCTURAL ENGINEER
BOB D. CAMPBELL AND COMPANY
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
INDUSTRIAL HYGIENIST
TITAN ENVIRONMENTAL SERVICES
2418 MERRIAM LANE
KANSAS CITY, KS. 66106
(913) 432-5500
MEP & FP ENGINEER
LANKFORD | FENDER & ASSOCIATES
1730 WALNUT
KANSAS CITY, MO. 64108
(816) 221-1429
100% CONSTRUCTION DOCS REVIEW SUBMITTAL 8/10/2018
100% CONSTRUCTION DOCUMENTS
Phone: 816.221.1411 | Fax: 816.221.1429
1730 Walnut Street Kansas City, Missouri 64108 1915 Frederick Avenue, St. Joseph, Missouri 64501
COA No.
Lankford Fendler a s s o c i a t e s
COPYRIGHT C 2018
LANKFORD | FENDLER + ASSOCIATES, CONSULTING ENGINEERS, INC.
Project No.
2006001168
18.5833.00
100% CONSTRUCTION DOCS REVISIONS TO BUDGET 7/19/2019
PD201JMSLDR
FIRST FLOOR PLAN-MED GAS DEMO
PHASE IIB - PART 1
33 48
C1-63A
VESTIBULE
C1-63A
CORRIDOR
C1-62C
CORRIDOR
V1-673
OFFICE
SUPERVISOR
V1-671
STAFF LOCKER/
LOUNGE
V1-671A
BIOMED
NETWORK
CLOSET
V1-675
OFFICE
V1-675B
ARMORY &
EVIDENCE
ROOM
OFFICE
V1-675A
VA POLICE
V1-683
ADMISSIONS
V1-654
TRIAGE
STATION 2
V1-650
ED 11
V1-652
ED 12
V1-687
ADMISSIONS
V1-642B
TOILET
V1-642C
TOILET
C1-62A
CORRIDOR
EXISTING
SHAFT
TO
REMAIN
G'
G1'
H'
J'
F'
E'
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
E F
E C
PARTIAL FIRST FLOOR PLAN-PLUMBING NEW WORK
SCALE: 1/8"= 1' 0"
1. CONNECT TO EXISTING WATER PIPING AS INDICATED.
2. 1/2" HOT AND COLD WATER DOWN TO SINK. 2" WASTE DOWN, 1 1/2" VENT UP.
3. 1/2' HOT AND COLD WATER DOWN TO LAVATORY, AND 1/2" COLD WATER TO TRAP
PRIMER. 1 1/2" WASTE DOWN, 1 1/2" VENT UP. CONNECT OUTLET OF TRAP PRIMER TO
INLET ON FLOOR DRAIN PER MANUFACTURER'S RECOMMENDATIONS.
4. 1" COLD WATER DOWN TO WATER CLOSET.
5. 1/2" HOT AND COLD WATER DOWN TO SHOWER VALVE.
6. 3/4" HOT AND COLD WATER DOWN IN WALL. ROUTE 1/2" HOT AND COLD WATER TO EACH
SINK. 2" WASTE DOWN, 1 1/2" VENT UP.
7. VALVE AND CAP PIPING FOR FUTURE CONNECTION IN PHASE III. PROVIDE TEMPORARY
VALVED, BRAIDED, STAINLESS STEEL HOSE CONNECTION BETWEEN HOT WATER AND
RECIRCULATION PIPING. MINIMIZE LENGTH OF DEAD LEGS IN CAPPED PIPING.
8. CONNECT TO EXISTING VENT PIPING AS INDICATED.
9. CONNECT TO EXISTING WASTE PIPING BELOW FLOOR AS INDICATED.
10. PROVIDE 1/2" TEE, SHUTOFF VALVE, AND HOSE CONNECTION.
11. ROUTE 1/2" COLD WATER TO TRAP PRIMER VALVE. CONNECT OUTLET OF TRAP PRIMER
TO INLET ON FLOOR DRAIN(S) PER MANUFACTURER'S RECOMMENDATIONS.
12. 3/4" COLD WATER DOWN TO ICE MACHINE WITH DOUBLE CHECK BFP AND FILTER (BY
OTHERS) IN ACCESSIBLE LOCATION. ROUTE DRAIN FROM ICE MACHINE TO DRAIN BOX IN
WALL AND INDIRECT WASTE. 2" WASTE DOWN, 1 1/2" VENT UP.
13. 1/2" HOT AND COLD WATER DOWN TO RECESSED MIXING VALVE. ROUTE 1/2" TEMPERED
WATER TO INLET OF EYE/FACE WASH PER MANUFACTURER'S RECOMMENDATIONS.
FLOOR PLAN NOTES
##P
P102
P528
P528
P418
1 1/2" HW
2" CW
3/4" HWR
(TYP 2)
01P
N
6A 72' 3' 4'3.9' 4.2'
E'
F'
G'
G1'
H'
J'
NOT IN SCOPE
W
2" V
3/4" HWR
3/4" HW
3'
FD-C
02P
WCO
1/2" CW
1/2" HW
1 1/2" CW
3/4" HW
1/2" HWR
3/4" HW
1 1/2" CW
3/4" HWR
1 1/4" HW
2" CW
3/4" HW
3/4" CW
WCO
03P
2" W
04P
05P
06P
07P
W
V
2" W
1 1/2" V 2" V
07P
07P
1 1/2" CW
1" HW
1/2" HWR
C
W
H
W
H
W R
1 1/4" HW
2" CW
1 1/4" HW
2" CW
3/4" HWR
1/2" CW
1/2" HW
3/4" HW
3/4" CW
08P
09P
WCO
10P
P701
TP-1
02P
P528
P701
FD-C
TP-1
WCO
13P
09P
3/4" CW
3/4" HW
11P
3/4" CW
12P
V
P808
2" V
2" V
V1-844
TREATMENT
ROOM-3
V1-840
SHOWER
TOILET
TREATMENT
ROOM-2
TREATMENT
ROOM-1
V1-837
BIOMED
CLOSET
V1-842
V1-838
C1-62C
CORRIDOR
V1-668
NOURISHMENT
V1-834
ELECT
ROOM
Lankford Fendler a s s o c i a t e s
BLDG 26
BLDG 1
BLDG
PHASE II
N
Revisions
Drawing Name: P:\18.5800\18.5833.00_KCVAMC-Emergency Dept-Remodel Phase II\Drawings\PHASE 2 DRAWINGS\18.5833.00PL101.dwg Jul 25,2019 - 5:01pm
Date
Drawing Title:
Scale:
Approved:
Sheet of
Building Number:
Location:
Project Title:
Checked By:
DRAWING NO.
Project No.
Drawn By:
Date:
D e p a r t m e n t o f
V e t e r a n s
A f f a i r s
589-396
CONSULTANTS:ARCHITECT:
8/10/2018
EMERGENCY ROOM EXPANSION, PHASE IIB
KANSAS CITY VA MEDICAL CENTER
4801 Linwood Blvd
Kansas City , MO 64128
Kansas City VA Medical Center
4801 Linwood Blvd, Kansas City, MO 64128
95% DESIGN REVIEW 05/31/2018
STRUCTURAL ENGINEER
BOB D. CAMPBELL AND COMPANY
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
INDUSTRIAL HYGIENIST
TITAN ENVIRONMENTAL SERVICES
2418 MERRIAM LANE
KANSAS CITY, KS. 66106
(913) 432-5500
MEP & FP ENGINEER
LANKFORD | FENDER & ASSOCIATES
1730 WALNUT
KANSAS CITY, MO. 64108
(816) 221-1429
100% CONSTRUCTION DOCS REVIEW SUBMITTAL 8/10/2018
100% CONSTRUCTION DOCUMENTS
Phone: 816.221.1411 | Fax: 816.221.1429
1730 Walnut Street Kansas City, Missouri 64108 1915 Frederick Avenue, St. Joseph, Missouri 64501
COA No.
Lankford Fendler a s s o c i a t e s
COPYRIGHT C 2018
LANKFORD | FENDLER + ASSOCIATES, CONSULTING ENGINEERS, INC.
Project No.
2006001168
18.5833.00
100% CONSTRUCTION DOCS REVISIONS TO BUDGET 7/19/2019
PL101JMSLDR
FIRST FLOOR PLAN-PLUMBING NEW WORK
34 48
M
A
M
V
O
ZVC
AAP-1C
1" M
V
1/2" O
ZVC
AAP-1A
AAP-1B
1/ 2"
O 1/
2" M
A
M
V 1/
2" O
1/ 2"
M A
3/4" MV
1/2" O
1/2" MA
3/4" MV
1/2" O
1/2" MA
1" M
V 1/
2" O
3/ 4"
M A
3/ 4"
M V
1/ 2"
O 1/
2" M
A
1" M
V 1/
2" O
3/ 4"
M A
1" M
V 1/
2" O
1/ 2"
M A
3/4" MV
1/2" O
1/2" MA
3/4" MV
1/2" O
1/2" MA
1" MV
1/2" O
3/4" MA
1" M
V 1/
2" O
1/ 2"
M A
1" MV
1/2" O
1/2" MA
1 1/4" MV
1/2" O
3/4" MA
1" MV
1/2" MA
1" MV
1/2" O
3/4" MA
6A 72' 3' 4'3.9' 4.2'
E'
F'
G'
G1'
H'
J'
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
C1-63A
VESTIBULE
C1-63A
CORRIDOR
C1-62C
CORRIDOR
V1-673
OFFICE
SUPERVISOR
V1-671
STAFF LOCKER/
LOUNGE
V1-671A
BIOMED
NETWORK
CLOSET
V1-675
OFFICE
V1-675B
ARMORY &
EVIDENCE
ROOM
OFFICE
V1-675A
VA POLICE
V1-683
ADMISSIONS
V1-654
TRIAGE
STATION 2
V1-650
ED 11
V1-652
ED 12
V1-687
ADMISSIONS
V1-642B
TOILET
V1-642C
TOILET
C1-62A
CORRIDOR
EXISTING
SHAFT
TO
REMAIN
G'
G1'
H'
J'
F'
E'
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
E F
E C
PARTIAL FIRST FLOOR PLAN-MED GAS NEW WORK
SCALE: 1/4"= 1' 0"
1. CONNECT TO EXISTING OXYGEN, VACUUM, AND MEDICAL AIR PIPING.
2. 1/2" O, 3/4" MV, 1/2" MA PIPED DOWN TO 2-O, 3-MV, 2-MA OUTLETS IN TREATMENT ROOM
HEADWALL UNIT.
3. VALVE AND CAP OXYGEN, VACUUM, AND MEDICAL AIR PIPING FOR FUTURE CONNECTION
TO PHASE IIB - PART 2, RE: PL202.
4. PRESSURE AND VACUUM SWITCHES INTERCONNECTED TO EXISTING AAP-1B.
FLOOR PLAN NOTES
##P
N
01P
02P
02P
02P
O
M
V
M
A
04P
1/2" MA
1/2" O
3/4" MV
1/2" MA
1/2" O
1" MV
6A 72' 3' 4'3.9' 4.2'
E'
F'
G'
G1'
H'
J'
3'
V1-844
TREATMENT
ROOM-3
V1-840
SHOWER
TOILET
TREATMENT
ROOM-2
TREATMENT
ROOM-1
V1-837
BIOMED
CLOSET
V1-842
V1-838
C1-62C
CORRIDOR
V1-668
NOURISHMENT
V1-834
ELECT
ROOM
Lankford Fendler a s s o c i a t e s
BLDG 26
BLDG 1
BLDG
PHASE II
N
Revisions
Drawing Name: P:\18.5800\18.5833.00_KCVAMC-Emergency Dept-Remodel Phase II\Drawings\PHASE 2 DRAWINGS\18.5833.00PL201.dwg Jul 25,2019 - 5:01pm
Date
Drawing Title:
Scale:
Approved:
Sheet of
Building Number:
Location:
Project Title:
Checked By:
DRAWING NO.
Project No.
Drawn By:
Date:
D e p a r t m e n t o f
V e t e r a n s
A f f a i r s
589-396
CONSULTANTS:ARCHITECT:
8/10/2018
EMERGENCY ROOM EXPANSION, PHASE IIB
KANSAS CITY VA MEDICAL CENTER
4801 Linwood Blvd
Kansas City , MO 64128
Kansas City VA Medical Center
4801 Linwood Blvd, Kansas City, MO 64128
95% DESIGN REVIEW 05/31/2018
STRUCTURAL ENGINEER
BOB D. CAMPBELL AND COMPANY
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
INDUSTRIAL HYGIENIST
TITAN ENVIRONMENTAL SERVICES
2418 MERRIAM LANE
KANSAS CITY, KS. 66106
(913) 432-5500
MEP & FP ENGINEER
LANKFORD | FENDER & ASSOCIATES
1730 WALNUT
KANSAS CITY, MO. 64108
(816) 221-1429
100% CONSTRUCTION DOCS REVIEW SUBMITTAL 8/10/2018
100% CONSTRUCTION DOCUMENTS
Phone: 816.221.1411 | Fax: 816.221.1429
1730 Walnut Street Kansas City, Missouri 64108 1915 Frederick Avenue, St. Joseph, Missouri 64501
COA No.
Lankford Fendler a s s o c i a t e s
COPYRIGHT C 2018
LANKFORD | FENDLER + ASSOCIATES, CONSULTING ENGINEERS, INC.
Project No.
2006001168
18.5833.00
100% CONSTRUCTION DOCS REVISIONS TO BUDGET 7/19/2019
PL201JMSLDR
FIRST FLOOR PLAN-MED GAS NEW WORK
35 48
WASTE AND VENT RISER DIAGRAM
NO SCALE
SECOND FLOOR
CEILING
FLOOR
W
P-701
W
FD-C
W
P-102
V
W
W
WCOWCO
V
V
2" V
P-418P-528 P-528P-528
2" W4" W4" W
4" W
V
V
V
2" V
4" W
1 1/2" V
2" V
1 1/2" V
V1-840
SHOWER
TOILET
V1-840
SHOWER
TOILET
V1-840
SHOWER
TOILET
V1-840
SHOWER
TOILET
TREATMENT
ROOM-2
V1-842V1-844
TREATMENT
ROOM-3
TREATMENT
ROOM-1
V1-838
FIRE STOPPING DETAIL
GYPSUM/STUD WALL
NO SCALE INSULATED METALLIC PIPES
System No. W-L-5029 C
CL
ASS IF IED
Classified by Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
ANSI/UL1479 (ASTM E814) CAN/ULC S115
F Ratings — 1, 2 and 3 Hr (See Items 1, 3 and 4) F Ratings — 1, 2 and 3 Hr (See Items 1, 3 and 4)
T Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3) FT Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3)
L Rating At Ambient — 4 CFM/Sq Ft FH Ratings — 1, 2 and 3 Hr (See Items 1, 2 and 4)
SECTION A-A
A
A
4 3
L Rating At 400 F — Less Than 1 CFM/Sq Ft FTH Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3)
L Rating At Ambient — 4 CFM/Sq Ft
L Rating At 400 F — Less Than 1 CFM/Sq Ft
1. Wall Assembly — The 1, 2 or 3 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features:
A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide for 1 and 2 hr F and FH rating and 3-1/2 in. (89 mm) wide for 3 hr F and FH rating and spaced max 24 in. (610 mm) OC.
B. Gypsum Board* — Min 5/8 in. (16 mm) thick with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 18-5/8 in. (473 mm).
The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed.
2. Through Penetrants — One metallic pipe or tubing to be installed within the firestop system. Pipe or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or tubing may be used:
A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.
C. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. When the hourly F or FH Rating of the firestop system is 3 hr, the nom diam of copper tube shall not exceed 4 in. (102 mm).
D. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. When the hourly F or FH Rating of the firestop system is 3 hr, the nom diam of copper pipe shall not exceed 4 in. (102 mm).
3.Pipe Covering* — Nom 1, 1-1/2 or 2 in. (25, 38 or 51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m3) glass fiber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory-applied self-sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. For 1 and 2 hr F and FH Ratings, the annular space between insulated penetrant and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). For 3 hr F and FH Ratings, the annular space shall be min 0 in. (point contact) to max 1-1/4 in. (32 mm).
See Pipe and Equipment Covering — Materials (BRGU) category in the Building Material Directory for the names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used.
The hourly T, FT, FTH Ratings of the firestop system are 1/2 hr for 1 hr rated walls and 1 hr for 2 hr rated walls. For 3 hr rated walls, the hourly T, FT and FTH Ratings when steel and iron pipes are used are 1 hr. For 3 hr rated walls, the hourly T, FT and FTH Ratings when copper penetrants are used are 1-1/4 hr for 2 in. (51 mm) thick pipe covering and 0 hr for pipe covering thickness less than 2 in. (51 mm).
3A. Pipe Covering* — (Not Shown) — As an alternate to Item 3, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf) units sized to the outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 18 AWG stainless steel wire spaced max 12 in. (305
mm) OC. When the alternate pipe covering is used, the T and FT Rating shall be as specified in item 3 above.
See Pipe and Equipment Covering — Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used.
4.Fill, Void or Cavity Material* — Sealant — For 1 and 2 hr F and FH Rating, min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. For 3 hr F and FH Rating, min 1 in. (25 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point contact location between pipe covering and gypsum board, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at the pipe covering/gypsum board interface on both surfaces of wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
March 30, 2015
FIRE STOPPING DETAIL
CONCRETE WALL/FLOOR
NO SCALE INSULATED METALLIC PIPES
System No. C-AJ-5091
SECTION A-A
1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m³) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 29 in. (737 mm).
See Concrete Blocks (CAZT) category in the Fire Resistance directory for names of manufacturers.
2. Metallic Sleeve — (Optional) — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall. If the steel sleeve extends beyond the top surface of the floor or both surfaces of the wall, the T Rating of the firestop system is 0 hr.
2A. Sheet Metal Sleeve — (Optional) - Max 6 in. (152 mm) diam, min 26 ga galv steel provided with a 26 ga galv steel square flange spot welded to the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam. The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the floor.
2B. Sheet Metal Sleeve — (Optional) - Max 12 in. (305 mm) diam, min 24 ga galv steel provided with a 24 ga galv steel square flange spot welded to the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam. The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the floor.
3.Through Penetrants — One metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or tubing may be used:
A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B.Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.
C. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe.
D. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing.
4.Pipe Covering — Min 1/2 in. (13 mm) to max 2 in. (51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m³) glass fiber units jacketed on the outside with an all-service jacket. Longitudinal joints sealed with metal fasteners or factory-applied, self-sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. The annular space between the insulated pipe and the edge of the periphery of the opening shall be min 1/2 in. (13 mm) to max 12 in. (305 mm). When thickness of pipe covering is less than 2 in. (51 mm), the T Rating for the firestop system is 0 hr.
See Pipe Equipment Covering — Materials — (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used.
4A. Pipe Covering — (Not Shown) — As an alternate to Item 4, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf or 224 kg/m³) units sized to the outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 18 AWG stainless steel wire spaced max 12 in. (305
mm) OC. The annular space shall be min 1/2 in. (13 mm) to max 12 in. (305 mm).
5.Firestop System — The firestop system shall consist of the following:
A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m³) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material.
B.Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
A
A
5B
5A
C
CL
ASS IF IED
Classified by Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
ANSI/UL1479 (ASTM E814) CAN/ULC S115
F Rating — 2 Hr F Rating — 2 Hr
T Ratings — 0 and 1 Hr (See Items 2 and 4) FT Ratings — 0 and 1 Hr (See Items 2 and 4)
L Rating At Ambient — 4 CFM/sq ft FH Rating — 2 Hr
L Rating At 400 F — Less Than 1 CFM/sq ft FTH Ratings — 0 and 1 Hr (See Items 2 and 4)
L Rating At Ambient —4 CFM/sq ft
L Rating At 400 F —Less Than 1 CFM/sq ft
January 13, 2015
Lankford Fendler a s s o c i a t e s
Revisions
Drawing Name: P:\18.5800\18.5833.00_KCVAMC-Emergency Dept-Remodel Phase II\Drawings\PHASE 2 DRAWINGS\18.5833.00PG701.dwg Jul 25,2019 - 5:45pm
Date
Drawing Title:
Scale:
Approved:
Sheet of
Building Number:
Location:
Project Title:
Checked By:
DRAWING NO.
Project No.
Drawn By:
Date:
D e p a r t m e n t o f
V e t e r a n s
A f f a i r s
589-396
CONSULTANTS:ARCHITECT:
8/10/2018
EMERGENCY ROOM EXPANSION, PHASE IIB
KANSAS CITY VA MEDICAL CENTER
4801 Linwood Blvd
Kansas City , MO 64128
Kansas City VA Medical Center
4801 Linwood Blvd, Kansas City, MO 64128
95% DESIGN REVIEW 05/31/2018
STRUCTURAL ENGINEER
BOB D. CAMPBELL AND COMPANY
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
INDUSTRIAL HYGIENIST
TITAN ENVIRONMENTAL SERVICES
2418 MERRIAM LANE
KANSAS CITY, KS. 66106
(913) 432-5500
MEP & FP ENGINEER
LANKFORD | FENDER & ASSOCIATES
1730 WALNUT
KANSAS CITY, MO. 64108
(816) 221-1429
100% CONSTRUCTION DOCS REVIEW SUBMITTAL 8/10/2018
100% CONSTRUCTION DOCUMENTS
Phone: 816.221.1411 | Fax: 816.221.1429
1730 Walnut Street Kansas City, Missouri 64108 1915 Frederick Avenue, St. Joseph, Missouri 64501
COA No.
Lankford Fendler a s s o c i a t e s
COPYRIGHT C 2018
LANKFORD | FENDLER + ASSOCIATES, CONSULTING ENGINEERS, INC.
Project No.
2006001168
18.5833.00
100% CONSTRUCTION DOCS REVISIONS TO BUDGET 7/19/2019
P701JMSLDR
PLUMBING RISERS
36 48
PARTIAL FIRST FLOOR PLAN-FIRE PROTECTION
SCALE: 1/8"= 1' 0"
FLOOR PLAN NOTES
##F
N
1. PROTECT AREA PER NFPA 13 FOR LIGHT HAZARD OCCUPANCY (0.10/1500 + 100 GPM
HOSE).
2. PROTECT AREA PER NFPA 13 FOR ORDINARY HAZARD GROUP 2 OCCUPANCY (0.20/1500 +
250 HOSE).
3. PROVIDE SPRINKLER PROTECTION AT LOCATION OF TEMPORARY WALLS SEPARATING
DIFFERENT PHASES OF CONSTRUCTION AS REQUIRED TO PROVIDE COMPLETE
CONTINUOUS SPRINKLER COVERAGE DURING CONSTRUCTION IN ACCORDANCE WITH
NFPA 13.
01F
02F
01F 01F 01F
01F
K-4450-C STRATTON C_TOILETS VITREOUS CHINA
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
6A 72' 3' 4'3.9' 4.2'
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
EXISTING
SHAFT
TO
REMAIN
G'
G1'
H'
J'
F'
E'
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
E F
E C
A. EXISTING WET PIPE SPRINKLER SYSTEM SHALL BE EXTENDED / MODIFIED FOR NEW
WORK. (PROVIDE NEW CONTROL VAVLE TO ISOLATE THE NEW CONSTRUCTION.) ENTIRE
SYSTEM SHALL BE DESIGNED FOR STRICT COMPLIANCE WITH THE RULES AND
REGULATIONS OF APPLICABLE FEDERAL, STATE AND LOCAL LAWS, CODES AND
ORDINANCES, THE OWNER'S INSURANCE COMPANY AND NFPA-13, AND THE VA FIRE
PROTECTION DESIGN MANUAL. SYSTEM SHALL BE COMPLETE AND FULLY CODE
COMPLIANT.
B. CONTRACTOR SHALL COORDINATE WITH NEW REFLECTED CEILING PLAN, NEW
DUCTWORK LAYOUT AND LIGHTING LAYOUTS. FURNISH ALL MATERIALS, LABOR, TOOLS,
TRANSPORTATION, INCIDENTALS AND APPURTENANCES TO COMPLETE IN EVERY DETAIL
AND LEAVE IN WORKING ORDER ALL ITEMS OF WORK REQUIRED FOR SYSTEM OPERATION.
a. NPS 2 (DN 50) AND SMALLER: THREADED-END, BLACK STANDARD-WEIGHT STEEL PIPE; CAST-
OR MALLEABLE-IRON THREADED FITTINGS; AND THREADED JOINTS.
b. NPS 1-1/2 (DN 40) AND LARGER: GROOVED-END, SCHEDULE 10 STEEL PIPE; STEEL-WELDING
FITTINGS, GROOVED-END FITTINGS; GROOVED-END-PIPE COUPLINGS; AND GROOVED JOINTS.
C. FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED AND COORDINATED SHOP
DRAWINGS SO AS TO AVOID CONFLICTS IN THE FIELD. ALL SPRINKLER LINES SHALL BE
CONCEALED, AVOIDING INTERFERENCES WITH LIGHTS, DUCTS, PIPES, ETC. ALL
COORDINATION SHALL TAKE PLACE PRIOR TO INSTALLATION.
D. CONTRACTOR SHALL FILE ALL DRAWINGS, PAY ALL FEES AND OBTAIN PERMITS AND
CERTIFICATES OF INSPECTIONS RELATIVE TO THIS WORK. CONTRACTOR SHALL BE
RESPONSIBLE FOR FIELD VERIFICATION OF EXISTING SPRINKLERS, PIPING, ETC.
E. FIRE PROTECTION CONTRACTOR TO REPLACE EXISTING SPRINKLERS TO ACCOMMODATE
AREAS WHERE CEILING WORK IS TO TAKE PLACE PER NFPA 13 SPRINKLERS CANNOT BE
RELOCATED AND REUSED. RE: ARCHITECTURAL REFLECTED CEILING PLANS.
F. SYSTEM SHALL BE INSTALLED IN CONFORMANCE WITH NFPA 25 SECTION 5.2.2.2 AND
PIPING SHALL NOT BE SUBJECTED TO EXTERNAL LOADS BY MATERIALS EITHER RESTING
ON THE PIPE OR HUNG FROM THE PIPE.
G. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
GENERAL NOTES
TREATMENT
ROOM-1
V1-838
V1-837
BIOMED
CLOSET
V1-840
SHOWER
TOILET
TREATMENT
ROOM-2
V1-842
V1-844
TREATMENT
ROOM-3
C1-62C
CORRIDOR
03F
03F
FP101
Lankford Fendler a s s o c i a t e s
BLDG 26
BLDG 1
BLDG
PHASE II
N
Revisions
Drawing Name: P:\18.5800\18.5833.00_KCVAMC-Emergency Dept-Remodel Phase II\Drawings\PHASE 2 DRAWINGS\18.5833.00FP101.dwg Jul 25,2019 - 5:19pm
Date
Drawing Title:
Scale:
Approved:
Sheet of
Building Number:
Location:
Project Title:
Checked By:
DRAWING NO.
Project No.
Drawn By:
Date:
D e p a r t m e n t o f
V e t e r a n s
A f f a i r s
589-396
CONSULTANTS:ARCHITECT:
8/10/2018
EMERGENCY ROOM EXPANSION, PHASE IIB
KANSAS CITY VA MEDICAL CENTER
4801 Linwood Blvd
Kansas City , MO 64128
Kansas City VA Medical Center
4801 Linwood Blvd, Kansas City, MO 64128
95% DESIGN REVIEW 05/31/2018
STRUCTURAL ENGINEER
BOB D. CAMPBELL AND COMPANY
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
INDUSTRIAL HYGIENIST
TITAN ENVIRONMENTAL SERVICES
2418 MERRIAM LANE
KANSAS CITY, KS. 66106
(913) 432-5500
MEP & FP ENGINEER
LANKFORD | FENDER & ASSOCIATES
1730 WALNUT
KANSAS CITY, MO. 64108
(816) 221-1429
100% CONSTRUCTION DOCS REVIEW SUBMITTAL 8/10/2018
100% CONSTRUCTION DOCUMENTS
Phone: 816.221.1411 | Fax: 816.221.1429
1730 Walnut Street Kansas City, Missouri 64108 1915 Frederick Avenue, St. Joseph, Missouri 64501
COA No.
Lankford Fendler a s s o c i a t e s
COPYRIGHT C 2018
LANKFORD | FENDLER + ASSOCIATES, CONSULTING ENGINEERS, INC.
Project No.
2006001168
18.5833.00
100% CONSTRUCTION DOCS REVISIONS TO BUDGET 7/19/2019
FIRST FLOOR PLAN-FIRE PROTECTION
PHASE IIB - PART 1
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
· REFER TO ARCHITECTS REFLECTED CEILING PLANS FOR EXACT PLACEMENT OF LIGHT
FIXTURES, SPEAKER AND F.A. DEVICES IN THE CEILING SYSTEM.
· REFER TO ARCHITECTURAL DETAILS AND ELEVATIONS FOR COORDINATION OF LOCATION
OF ALL WIRING DEVICES BEFORE ROUGH-IN OF J-BOXES.
· WIRING TO BE REMOVED BACK TO THE NEAREST DEVICE TO REMAIN.
· ANY MATERIAL REMOVED THAT OWNER DOES NOT WISH TO RETAIN SHALL BE REMOVED
FROM PROJECT SITE AND DISPOSED OF BY THE CONTRACTOR DAILY.
· PROVIDE UPDATED, TYPEWRITTEN PANELBOARD DIRECTORY FOR EACH PANELBOARD
WHICH CIRCUITS HAVE BEEN ADDED TO OR MODIFIED.
· CONTRACTOR TO REFERENCE BRANCH CIRCUIT COPPER CONDUCTOR AND CONDUIT
SIZING CHART FOR SIZING OF BRANCH CIRCUITS AND OR FEEDERS AT OR BELOW
100AMPS.
· SUPPORT ALL LIGHT FIXTURES WITH A MINIMUM OF (4) 12 GA. HANGER WIRES TO
STRUCTURE ABOVE.
· CONNECT EXIT AND EMERGENCY LIGHTS TO HOT LEG, NOT SWITCH LEG.
· REPAIR AND/OR REPLACE ANY DAMAGED CEILING TILE OR GRID DUE TO INSTALLATION OF
CONDUITS, ETC. ABOVE EXISTING CEILING. WALK BUILDING WITH ARCHITECT PRIOR TO
COMMENCING WORK TO NOTE ANY EXISTING DAMAGED CEILING TILE OR GRID.
· LOCATE ALL IN SLAB REBAR PRIOR TO CORE DRILLING AND SHALL ADJUST CORE
LOCATIONS AS TO AVOID REBAR. PROVIDE MINIMUM SPACING BETWEEN CORE DRILL
LOCATIONS AS REQUIRED BY POKE THROUGH DEVICE UL LISTING. ALL CORE DRILLING
AND WORK DONE BELOW FLOOR SHALL BE DONE AFTER HOURS.
· DISCONNECTS FOR MECHANICAL EQUIPMENT ARE PROVIDED BY OTHERS. UNLESS
NOTED OTHERWISE.
· CONTRACTOR SHALL FOLLOW THE FOLLOWING GUIDE LINES;
a. MAXIMUM OF 6 RECEPTACLE PER 120V CIRCUIT.
b. MAXIMUM OF 16A PER 20A/1P CIRCUIT BREAKER.
c. WHERE ACCEPTABLE INSTALL SWITCHES UNDER COMMON FACE PLATE.
d. PROVIDE DEDICATED CIRCUIT FOR EVERY COPY MACHINE AND ABOVE COUNTER
GFI'S.
e. CONTRACTOR SHALL INSTALL FIRE ALARM DEVICES THAT COMPLIES WITH
APPLICABLE CODES. INCLUDING BUT NOT LIMITED TO THE NFPA, UL, ADA.
f. CONTRACTOR SHALL COMPLY WITH THE NEC OR ANY OTHER CODES HAVING
JURISDICTION.
· THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN BID ALL COSTS ASSOCIATED WITH FIRE
ALARM MODIFICATIONS. THIS WORK SHALL INCLUDE POWER EXTENDER PANEL, SMOKE
DETECTORS, HORN/STROBES, PULL STATIONS, REMOTE INDICATING LIGHTS AND ANY
OTHER FIRE ALARM WORK SHOWN ON PLANS. ALL WIRING, PLENUM RATED CABLING,
BETWEEN DEVICES SHALL BE INCLUDED IN WORK TO PROVIDE AN OPERATIONAL
EXTENSION OF THE EXISTING FIRE ALARM SYSTEM.
· ALIGN ALL WIRING DEVICES IN VERTICAL ALIGNMENT. IF ANY DEVICE(S) ARE FOUND NOT
TO BE INSTALLED PER DETAIL CONTRACTOR SHALL RELOCATE AND PAY ALL ASSOCIATED
COSTS ASSOCIATED WITH THE RELOCATION(S).
· LIGHTING INDICATED ABOVE EXIT DISCHARGE DOOR IS FOR MEANS OF EGRESS
ILLUMINATION PER IBC 1006.1.
· MEANS OF EGRESS TO BE ILLUMINATED AT NOT LESS THAN 1 FOOTCANDLE AT THE
FLOOR. CONTRACTOR SHALL PROVIDE AND INSTALL IF NECESSARY ADDITIONAL
EMERGENCY FIXTURES IF NECESSARY TO MEET THE REQUIRED READINGS.
· PROVIDE FIRE STOP ON ALL PIPING AT FLOOR PENETRATIONS PER LOCAL CODE
REQUIREMENTS. METHOD OF FIRE STOP SHALL MEET WALL RATING. RE:
ARCHITECTURAL DRAWINGS FOR LOCATION OF FIRE RATED WALLS. PROVIDE FIRE CAP
HOUSING FOR ALL FIXTURES THAT PENETRATE FIRE RATED CEILINGS.
· INSTALL FIRE ALARM DEVICES THAT COMPLY WITH APPLICABLE CODES. INCLUDING BUT
NOT LIMITED TO THE FAIR HOUSING ACT, NFPA, UL, ADA, IBC OR ANY OTHER AUTHORITIES
HAVING JURISDICTION.
· WHERE MORE THAN ONE SWITCH IS INDICATED ON DRAWINGS SIDE BY SIDE,
CONTRACTOR SHALL INSTALL SWITCHES UNDER ONE COMMON FACE PLATE.
· FIRE ALARM CONTRACTOR IS RESPONSIBLE OF TESTING AND VERIFYING THAT THE
AUDIBILITY OF THE FIRE ALARM SYSTEM MEETS A MINIMUM OF 15 DBA ABOVE AMBIENT
NOISE LEVELS. AFTER INSTALLATION AND BEFORE CERTIFICATE OF OCCUPANCY. ADD
HORNS WHERE REQUIRED TO MAINTAIN MINIMUM LEVELS.
· UPON REQUEST FOR ELECTRONIC FILES, CONTRACTOR SHALL FILL OUT, SIGN AND
RETURN ELECTRONIC MEDIA RELEASE FORM FROM ENGINEER AND PROVIDE PAYMENT
FOR FEES STIPULATED ON ELECTRONIC MEDIA RELEASE FORM. UPON RECEIPT OF
COMPLETED RELEASE FORM AND PAYMENT, ELECTRONIC FILES WILL BE RELEASED.
· CONTRACTOR SHALL BE RESPONSIBLE FOR THE RECONNECTION OF ALL EXISTING
ELECTRICAL LOADS, WHICH ARE TO REMAIN, TO NEW ELECTRICAL DISTRIBUTION SYSTEM.
· WHERE THE DRAWINGS INDICATE DEDICATED CIRCUITRY WITH NO SHARED NEUTRALS,
THE CONTRACTOR SHALL NOT INSTALL MULTI-WIRE BRANCH CIRCUITS WITH A COMMON
NEUTRAL.
· ALL PATIENT CARE AREAS SHALL MEET GROUNDING REQUIREMENTS OF NEC ARTICLE
517.13. WHERE TYPE MC CABLE IS USED, THE METAL SHEATHING SHALL BE LISTED AS AN
ACCEPTABLE GROUNDING PATH - TYPE 'HCFMC'.
· CONTRACTOR SHALL PROVIDE DEVICE BOX EXTENSION RINGS AS REQUIRED WHERE
ADDITIONAL DRYWALL IS BEING ADDED TO WALLS TO COMPENSATE FOR ADDITIONAL
WALL THICKNESS.
· ALL THROUGH WALL PENETRATIONS FOR LOW-VOLTAGE CABLING RACEWAYS SHALL BE
FIRE-STOPPED USING HILTI 'CP 653 BA' (OR PRE-BID APPROVED EQUAL) MANUFACTURED
FIRE-STOPPING DEVICES.
· SECURITY CABLING AND DEVICES ARE BY OTHERS - COORDINATE WITH VA COR.
SECURITY SCOPE OF PLANS COVERS RACEWAY AND INFRASTRUCTURE ONLY.
· NURSE CALL CABLING AND DEVICES ARE BY OTHERS - COORDINATE WITH VA COR.
NURSE CALL SCOPE OF PLANS COVERS RACEWAY AND INFRASTRUCTURE ONLY.
· LOW-VOLTAGE COMMUNICATIONS CABLING AND DEVICES ARE BY OTHERS - COORDINATE
WITH VA COR. LOW-VOLTAGE COMMUNICATIONS SCOPE OF PLANS COVERS RACEWAY
AND INFRASTRUCTURE ONLY.
GENERAL NOTES
(TYPICAL ALL SHEETS)
AFF ABOVE FINISH FLOOR
EXISTING TO REMAINETR
EMERGENCY POWER DOUBLE DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE. +1'-6" AFF OR AS NOTED
DOUBLE DUPLEX RECEPTACLE INSTALLED ABOVE COUNTERTOP.
DUPLEX RECEPTACLE W/GROUND FAULT PROTECTION.
+1'-6" AFF OR AS NOTED
EMERGENCY POWERED DUPLEX RECEPTACLE
PUSH BUTTON +4'-0" AFF.
DUPLEX RECEPTACLE. +1'-6" AFF OR AS NOTED
DUPLEX RECEPTACLE INSTALLED ABOVE COUNTERTOP
INDICATES WIRING DEVICE ABOVE RE: DRAWING
MECHANICAL EQUIPMENT CALL OUT BUBBLE
THERMOSTAT OUTLET BOX WITH 3/4"C, STUBBED UP OUT OF BOX TO ABOVE
ACCESSIBLE CEILING. THERMOSTAT AND WIRING BY OTHERS. +4'-0" AFF OR
AS NOTED.
CARD READER. PROVIDE DOUBLE GANG J-BOX WITH SINGLE GANG PLASTER
RING WITH 3/4"C STUBBED UP INSIDE WALL AND OUT TO ACCESSIBLE CEILING
WITH BUSHING ON THE END. +3'-10" AFF OR AS NOTED.
WALL MOUNTED OR CEILING MOUNTED JUNCTION BOX.
WALL MOUNTED JUNCTION BOX WITH BLANK COVERPLATE.
FIRE ALARM MANUAL PULL STATION. +4'-0" AFF
FIRE AND SMOKE DAMPER 120V, 1Ø
CEILING MOUNTED REMOTE INDICATED LIGHT FOR DUCT MOUNTED
SMOKE DETECTOR.
CEILING MOUNTED PHOTO-ELECTRIC SMOKE DETECTOR
LOW VOLTAGE COMMUNICATIONS OUTLET, DOUBLE GANG BOX WITH SINGLE
GANG PLASTER RING. INSTALL 1" CONDUIT STUBBED UP OUT OF TOP OF BOX
TO ABOVE AN ACCESSIBLE CEILING. INSTALL ABOVE COUNTER.
LOW VOLTAGE COMMUNICATIONS OUTLET, DOUBLE GANG BOX WITH SINGLE
GANG PLASTER RING. INSTALL 1" CONDUIT STUBBED UP OUT OF TOP OF BOX
TO ABOVE AN ACCESSIBLE CEILING. +1'-6" AFF OR AS NOTED.
DOOR HOLDER 120V, 1Ø, CONNECT TO FIRE ALARM CONTROL PANEL
OR
FSD
OR
W
GFI
INDICATES X/X= 2-POLE C.B., X/X/X = 3-POLE C.B.
ELECTRICAL SYMBOLS
GROUND CONDUCTOR
NEUTRAL CONDUCTOR
PHASE CONDUCTORS
HOMERUN INDICATED LIKE THIS INDICATED THREE SEPARATE CIRCUITS
BRANCH CIRCUIT CONCEALED IN CEILING OR WALL. ARROWS INDICATE
HOMERUNS TO PANEL. ALL CONDUCTORS ARE MINIMUM NO.12 UNLESS
NOTED OTHERWISE.
GROUNDING CONDUCTOR NO.12 WIRE EXCEPT AS NOTED
CONDUIT RUN UNDERGROUND OR CONCEALED IN FLOOR SLAB.
CONDUIT CONCEALED IN CEILING OR WALL WITH THREE CONDUCTORS:
1-PHASE; 1-NEUTRAL; 1-GROUND WIRE, MINIMUM NO.12 WIRE UNLESS
OTHERWISE SPECIFIED ON DRAWINGS.
EXIT SIGN - SINGLE FACED - ARROWS AS SHOWN ON DRAWING. SHADED
SIDE(S) INDICATES FACE SIDE(S) OF EXIT.
EXIT SIGN - DOUBLE FACED - ARROWS AS SHOWN ON DRAWING. SHADED
SIDE(S) INDICATES FACE SIDE(S) OF EXIT.
2x4 / 2x2 LIGHT FIXTURE ON EMERGENCY POWER - CRITICAL BRANCH -
LETTER DENOTES FIXTURES TYPE, REFER TO FIXTURE SCHEDULE FOR TYPE
SINGLE POLE SWITCH. +4'-0" AFF TO CENTERLINE OF DEVICE BOX
DISCONNECT SWITCH, SIZE AND TYPE AS NOTED
TOP MOUNTED 5'-0" AFF
480/277V PANELBOARD (SURFACE) TOP MOUNTED 6'-0" AFF
CONDUIT STUBBED THRU WALL WITH BUSHINGS ON BOTH ENDS. SIZE
AS NOTED ON PLANS.
EMPTY CONDUIT STUB-UP INSIDE WALL TO ABOVE ACCESSIBLE CEILING WITH
BUSHING ON THE END. SIZE AS NOTED ON DRAWINGS.
208Y/120V PANELBOARD (SURFACE) TOP MOUNTED 6'-0" AFF
POWER CONNECTION POINT
SURFACE MOUNTED EQUIPMENT, TYPE AS INDICATED ON DRAWINGS
FLUSH MOUNTED EQUIPMENT, TYPE AS INDICATED ON DRAWINGS
WALL WASH OR RECESSED CEILING LIGHT FIXTURE
STRIP FIXTURE, LETTER DENOTES FIXTURE TYPE, REFER TO SCHEDULE
GROUND
CONDUIT DOWN
CONDUIT UP
OR
AA
OR
OR
OR
1/3, 1/3/5
CATV JUNCTION BOX WITH 3/4" CONDUIT STUBBED UP OUT OF BOX TO ABOVE
ACCESSIBLE CEILING. +1'-6" AFF OR AS NOTED.
VOICE OUTLET WITH 3/4" CONDUIT STUBBED UP OUT OF BOX TO ABOVE
ACCESSIBLE CEILING. INSTALLED ABOVE COUNTERTOP. (W DENOTES WALL
MOUNTED +48" AFF)
DUCT MOUNTED PHOTO-ELECTRIC SMOKE DETECTOR
FA COMBINATION HORN/STROBE WALL MOUNTED, +6'-8" AFF.
FA COMBINATION HORN/STROBE CEILING MOUNTED (FLUSH)
REQUEST TO EXIT MOTION SENSOR
ELECTRIC STRIKE
MAG-LOCK
FIXED CAMERA
PENDANT MOUNTED LIGHT FIXTURE, SIZE AND TYPE AS NOTED
CEILING MOUNTED HEAT DETECTOR
ML
ES
CR
RX
F
DH
RL
DH
T
X
DUPLEX RECEPTACLE MOUNTED IN CEILING TILE OR CEILING.
WALL MOUNTED MOTION SENSOR, +4'-0" AFF TO CENTERLINE OF DEVICE BOX,
TYPE AS INDICATED
MS
KEYPAD.KP
MS
CEILING MOUNTED MOTION DETECTOR TYPE AS INDICATED
JJ
B
TV
SWITCH-LEG AND OR TRAVELER
2x4 / 2x2 LIGHT FIXTURE, LETTER DENOTES FIXTURE TYPE, REFER TO
SCHEDULE
PREFABRICATED BEDSIDE PATIENT UNITPBPU
OR
2x4 / 2x2 LIGHT FIXTURE ON EMERGENCY POWER - LIFE SAFETY BRANCH -
LETTER DENOTES FIXTURES TYPE, REFER TO FIXTURE SCHEDULE FOR TYPE
480/277V E-POWER PANELBOARD (SURFACE) TOP MOUNTED 6'-0" AFF
208Y/120V E-POWER PANELBOARD (SURFACE) TOP MOUNTED 6'-0" AFF
WALL MOUNTED OR CEILING MOUNTED JUNCTION BOX, E-POWER.OR
JJ
LIGHTING GENERATOR TRANSFER DEVICE. WATTSTOPPER "ELCU-200",
OR EQUALS BY IOTA, BODINE.
GT
MS
CEILING MOUNTED MOTION DETECTOR TYPE AS INDICATED
UNLESS OTHERWISE NOTED ON THE DRAWINGS.=*
100 1 AWG
2 AWG
1-1/4"
8 AWG
8 AWG
1"
1-1/2"
1-1/4"
1-1/2"
1-1/4"
1-1/2"
1-1/4"
CONDUCTOR SIZE
BRANCH CIRCUIT COPPER CONDUCTOR
4 AWG
6 AWG
4 AWG
3 AWG
8 AWG
6 AWG
8 AWG
OVERCURRENT
PROTECTION DEVICE
RATING (AMPS)
12 AWG
12 AWG
10 AWG
10 AWG
SIZE
CONDUCTOR
REQUIRED
3/4"
3/4"
3/4"
3/4"
8 AWG
8 AWG
10 AWG
10 AWG
1"
1"
1"
10 AWG
10 AWG
10 AWG
1-1/4"
1"
3/4"
1"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
WIRE + GND.
SINGLE PHASE 2
CONDUIT SIZE
AND CONDUIT SIZING CHART
10 AWG
10 AWG
12 AWG
12 AWG
EQUIPMENT
GROUNDING
3/4"
3/4"
3/4"
3/4"
CONDUIT SIZE
SINGLE PHASE 3
WIRE + GND.
3/4"
1-1/4"
1"
1"
3/4"
3/4"
3/4"
1-1/4"
1-1/4"
1-1/4"
1"
3/4"
1"
3/4"
THREE PHASE 4
3/4"
3/4"
3/4"
3/4"
THREE PHASE 3
CONDUIT SIZE
WIRE + GND.
3/4"
3/4"
3/4"
3/4"
WIRE + GND.
CONDUIT SIZE
=* ALL CONDUCTORS SIZED ON THE POWER RISER DIAGRAM OR IN BRANCH CIRCUIT CONDUCTOR TABLE ARE BASED ON 3 CURRENT
CARRYING CONDUCTORS IN A RACEWAY OR CABLE. CONDUCTORS SHALL BE DERATED IN ACCORDANCE WITH THE NEC IF 4 OR MORE
CONDUCTORS ARE PLACED IN A RACEWAY OR CABLE.
UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL BRANCH CIRCUITS AND FEEDERS TO BE PROVIDED WITH A NEUTRAL WIRE.=*
S
VOICE SPEAKER, CEILING MOUNTED
WIRELESS ACCESS POINT.
WA
Lankford Fendler a s s o c i a t e s
BLDG 26
BLDG 1
BLDG
PHASE II
N
Revisions
Drawing Name: C:\Lankford CAD\Temp\AcPublish_9968\18.5833.00EG000.dwg Jul 25,2019 - 5:00pm
Date
Drawing Title:
Scale:
Approved:
Sheet of
Building Number:
Location:
Project Title:
Checked By:
DRAWING NO.
Project No.
Drawn By:
Date:
D e p a r t m e n t o f
V e t e r a n s
A f f a i r s
589-396
CONSULTANTS:ARCHITECT:
8/10/2018
EMERGENCY ROOM EXPANSION, PHASE IIB
KANSAS CITY VA MEDICAL CENTER
4801 Linwood Blvd
Kansas City , MO 64128
Kansas City VA Medical Center
4801 Linwood Blvd, Kansas City, MO 64128
95% DESIGN REVIEW 05/31/2018
STRUCTURAL ENGINEER
BOB D. CAMPBELL AND COMPANY
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
INDUSTRIAL HYGIENIST
TITAN ENVIRONMENTAL SERVICES
2418 MERRIAM LANE
KANSAS CITY, KS. 66106
(913) 432-5500
MEP & FP ENGINEER
LANKFORD | FENDER & ASSOCIATES
1730 WALNUT
KANSAS CITY, MO. 64108
(816) 221-1429
100% CONSTRUCTION DOCS REVIEW SUBMITTAL 8/10/2018
100% CONSTRUCTION DOCUMENTS
Phone: 816.221.1411 | Fax: 816.221.1429
1730 Walnut Street Kansas City, Missouri 64108 1915 Frederick Avenue, St. Joseph, Missouri 64501
COA No.
Lankford Fendler a s s o c i a t e s
COPYRIGHT C 2018
LANKFORD | FENDLER + ASSOCIATES, CONSULTING ENGINEERS, INC.
Project No.
2006001168
18.5833.00
100% CONSTRUCTION DOCS REVISIONS TO BUDGET 7/19/2019
EG000SMPJOB
ELECTRICAL GENERAL NOTES & SYMBOLS
38 48
1'0'
0'
0.1'
0.1'
0.9'
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
C1-63A
VESTIBULE
C1-63A
CORRIDOR
C1-62C
CORRIDOR
V1-673
OFFICE
SUPERVISOR
V1-671
STAFF LOCKER/
LOUNGE
V1-671A
BIOMED
NETWORK
CLOSET
V1-675
OFFICE
V1-675B
ARMORY &
EVIDENCE
ROOM
OFFICE
V1-675A
VA POLICE
V1-683
ADMISSIONS
V1-654
TRIAGE
STATION 2
V1-650
ED 11
V1-652
ED 12
V1-687
ADMISSIONS
V1-642B
TOILET
V1-642C
TOILET
C1-62A
CORRIDOR
EXISTING
SHAFT
TO
REMAIN
F'
E F
E C
PA
PARTIAL FIRST FLOOR PLAN-ELECTRICAL DEMOLITION
SCALE: 1/4"= 1' 0"
1. TOILET SHOWER AREA CROSS-HATCHED AREAS, INCLUDING WALLS, FLOORS, CEILING,
ELECTRICAL WIRING DEVICES, LIGHTING, SYSTEMS, NURSE CALL SYSTEMS AND ALL
ASSOCIATED POWER AND COMMUNICATIONS WIRING SHALL REMAIN INTACT AND FOR
USE BY VA PATIENTS UNTIL NEW TOILET/ SHOWER FACILITIES CAN BE PROVIDED BY THE
MEANS OF THIS PART 1 NEW CONSTRUCTION PROCESS. ACCESS TO THIS ROOM MUST
BE MAINTAINED UNOBSTRUCTED DURING PART 1.
2. EXISTING PANELBOARD TO BE DISCONNECTED AND REMOVED. RETAIN EXISTING
PANELBOARD, FEEDER AND ALL EXISTING TO REMAIN CIRCUITS FOR EXTENSION AND
RECONNECTION AT NEW LOCATION. RE: NEW WORK PLANS.
3. EXISTING LIGHTING FIXTURES TO BE TEMPORARILY DISCONNECTED AND RELOCATED TO
NEW LOCATION. RE: NEW WORK PLANS.
4. EXISTING FLOOR CONDUIT STUBS SHALL BE ABATED OF EXISTING CONDUCTORS, CUT
FLUSH WITH FLOOR AND GROUTED SHUT.
5. EXISTING LIGHTING FIXTURE TO BE TEMPORARILY DISCONNECTED AND REMOVED TO
FACILITATE INSTALLATION OF TEMPORARY WALL. RETAIN FIXTURE FOR
REINSTALLATION. RE: NEW WORK PLANS.
6. EXISTING ELECTRICAL ROOM - PANELS SHOWN FOR REFERENCE AND LOCATION.
B
B
J
B
B
B
B
B
B B B JJ
J
J
J
MS
MS
WA
S S
S
S
WA
J
B d
J d
J d
J d
J d
J d
S
RX
S
WA
S
S
B
S S
WA
S
WA
N
N
N
N
S
N
B
TV
TV
N
N
B
B
FLOOR PLAN NOTES
##E
B
TV
S
F
RX
CR
KP
S
MS
CR
KP
WA
S
J
B
N
B
WA
S
WA
N
N N
N
N
S
MS
WA
CR
J
WA
N
BB
MS
N
AP
CR
B
N
S
S
S
S
S
01E
DEMOLITION GENERAL NOTES
A. "DASHED" BOLD, EXISTING CEILING MOUNTED DEVICES WITHIN AREA OF WORK ARE TO
BE DISCONNECTED AND REMOVED - UNLESS SPECIFICALLY NOTED OTHERWISE VIA PLAN
NOTE OR WITH “ETR” INDICATION, INCLUDING BUT NOT LIMITED TO: EXISTING LIGHT
FIXTURES, JUNCTION BOXES, AUDIO/VISUAL DEVICES, SECURITY EQUIPMENT, NURSE
CALL AND FIRE ALARM DEVICES. REMOVE ALL ASSOCIATED CONDUIT AND CONDUCTORS
BACK TO SOURCE OR TO NEAREST DEVICE FOUND TO REMAIN. WHERE CIRCUITS
CONTINUE OUTSIDE OF THE RENOVATION AREA, MAINTAIN CIRCUIT
CONTINUITY. RETAIN & TEMPORARILY LABEL ANY UN-USED BREAKERS AS “SPARE”.
B. "DASHED" BOLD, EXISTING WALL MOUNTED (RECESSED AND/OR SURFACE
MOUNTED) POWER & COMMUNICATIONS DEVICES WITHIN AREA OF WORK ARE TO BE
DISCONNECTED AND REMOVED - UNLESS SPECIFICALLY NOTED OTHERWISE VIA PLAN
NOTE OR WITH “ETR” INDICATION, INCLUDING BUT NOT LIMITED TO: RECEPTACLES, LIGHT
SWITCHES, JUNCTION BOXES, VOICE/DATA OUTLETS, AUDIO VISUAL DEVICES, NURSE
CALL, EMERGENCY LIGHTS AND FIRE ALARM DEVICES. REMOVE ALL ASSOCIATED
CONDUIT AND CONDUCTORS BACK TO SOURCE OR TO NEAREST DEVICE FOUND TO
REMAIN. WHERE CIRCUITS CONTINUE OUTSIDE OF THE RENOVATION AREA, MAINTAIN
CIRCUIT CONTINUITY. RETAIN & TEMPORARILY LABEL ANY UN-USED BREAKERS
AS “SPARE”.
C. COORDINATE WITH THE VA FOR DISCONNECTION AND REMOVAL OF ANY LOW-VOLTAGE
COMMUNICATIONS CABLES PRIOR TO ANY DISCONNECTION.
D. VA SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL DEMOLISHED ITEMS.
04E
(TYP)
04E
(TYP)
02E
05E
(R2)
06E
03E
V1-845B
NURSE
STATION
V1-624
TREATMENT
ROOM-7
V1-626
TREATMENT
ROOM-8
V1-628
DOCTORS
WORK
V1-627
ELECTRICAL
V1-632A
PATIENT
TOILET
V1-632
TREATMENT
ROOM-9
V1-630
PATIENT
TOILET
V1-625
ANTE
ROOM
V1-845A
NURSE
STATION
V1-845
MEDS
C1-76
CORRIDOR
C1-62A
CORRIDOR
C1-62B
CORRIDOR
C1-77
CORRIDOR
V1-800
ED WAITING ROOM
S18
STAIRWELL
NO.18
V1-660
PANTRY
V1-659
STORAGE
N1-655
OPEN BAYS
V1-655
OPEN BAYS
V1-657
SOILED LINEN
V1-656
TOILET
V1-658
BED 10
V1-647
STORAGE
C1-62D
CORRIDOR
V1-609
STORAGE
Lankford Fendler a s s o c i a t e s
BLDG 26
BLDG 1
BLDG
PHASE II
N
Revisions
Drawing Name: P:\18.5800\18.5833.00_KCVAMC-Emergency Dept-Remodel Phase II\Drawings\PHASE 2 DRAWINGS\18.5833.00ED101.dwg Jul 25,2019 - 5:22pm
Date
Drawing Title:
Scale:
Approved:
Sheet of
Building Number:
Location:
Project Title:
Checked By:
DRAWING NO.
Project No.
Drawn By:
Date:
D e p a r t m e n t o f
V e t e r a n s
A f f a i r s
589-396
CONSULTANTS:ARCHITECT:
8/10/2018
EMERGENCY ROOM EXPANSION, PHASE IIB
KANSAS CITY VA MEDICAL CENTER
4801 Linwood Blvd
Kansas City , MO 64128
Kansas City VA Medical Center
4801 Linwood Blvd, Kansas City, MO 64128
95% DESIGN REVIEW 05/31/2018
STRUCTURAL ENGINEER
BOB D. CAMPBELL AND COMPANY
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
INDUSTRIAL HYGIENIST
TITAN ENVIRONMENTAL SERVICES
2418 MERRIAM LANE
KANSAS CITY, KS. 66106
(913) 432-5500
MEP & FP ENGINEER
LANKFORD | FENDER & ASSOCIATES
1730 WALNUT
KANSAS CITY, MO. 64108
(816) 221-1429
100% CONSTRUCTION DOCS REVIEW SUBMITTAL 8/10/2018
100% CONSTRUCTION DOCUMENTS
Phone: 816.221.1411 | Fax: 816.221.1429
1730 Walnut Street Kansas City, Missouri 64108 1915 Frederick Avenue, St. Joseph, Missouri 64501
COA No.
Lankford Fendler a s s o c i a t e s
COPYRIGHT C 2018
LANKFORD | FENDLER + ASSOCIATES, CONSULTING ENGINEERS, INC.
Project No.
2006001168
18.5833.00
100% CONSTRUCTION DOCS REVISIONS TO BUDGET 7/19/2019
ED101SMPJOB
FIRST FLOOR PLAN-ELECTRICAL DEMO
39 48
1'0'
0'
0.1'
0.1'
0.9'
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
EXISTING
SHAFT
TO
REMAIN
F'
REFRG
MICRO
K-4450-CSTRATTONC_TOILETSVITREOUS CHINA
E F
E C
PARTIAL FIRST FLOOR PLAN-POWER
SCALE: 1/8"= 1' 0"
1. PROVIDE 3/4', PRIMED AND PAINTED, FLAME RETARDANT, PLYWOOD BACK BOARD.
COORDINATE WITH COR.
2. TWO (2) 4" CONDUITS, WITH LONG RADIUS ELBOWS, RAN TIGHT TO STRUCTURE ABOVE.
COORDINATE ROUTING WITH ALL OTHER EXISTING UTILITIES. PROVIDE CONDUITS WITH
PULL STRING AND END BUSHINGS. GROUND EACH CONDUIT WITH A #6-AWG (cu)
GROUND WIRE. GROUND PER VA IT STANDARDS. CONDUITS SHALL HAVE LONG
SWEEPING ELBOWS.
3. COMMUNICATIONS GROUND BAR - RE: GROUND BAR DETAIL. GROUND TO NEAREST
BUILDING STEEL.
4. 4" CONDUIT SLEEVE THROUGH BIO-MED WALL. LOCATE ABOVE ACCESSIBLE CEILING
HEIGHT. PROVIDE WITH END BUSHINGS. TEMPORARILY SEAL CONDUIT SLEEVE DURING
ALL CONSTRUCTION UNTIL READY FOR UTILIZATION.
5. TOILET SHOWER AREA AND BIOMED STORAGE CLOSET CROSS-HATCHED AREAS,
INCLUDING WALLS, FLOORS, CEILING, ELECTRICAL WIRING DEVICES, LIGHTING,
SYSTEMS, NURSE CALL SYSTEMS AND ALL ASSOCIATED POWER AND COMMUNICATIONS
WIRING SHALL REMAIN INTACT AND FOR USE BY VA PATIENTS UNTIL NEW TOILET/
SHOWER FACILITIES CAN BE PROVIDED BY THE MEANS OF THIS PART 1 NEW
CONSTRUCTION PROCESS. ACCESS TO THIS ROOM MUST BE MAINTAINED
UNOBSTRUCTED DURING PART 1.
6. NORMAL POWER BRANCH CIRCUIT CONNECTION TO PRE-MANUFACTURED 'PBPU'
HEADWALL. MAKE REQUIRED CONNECTIONS TO THE HEADWALL UNIT AS REQUIRED.
COORDINATE WITH ARCHITECT FOR ROUGH-IN LOCATION AND CONNECTION
REQUIREMENTS. HEADWALL IS FURNISHED BY OTHERS AND CONNECTIONS BY
ELECTRICAL. REFER TO ARCHITECTURAL HEADWALL ELEVATIONS FOR DETAILS OF
HEADWALL CONFIGURATIONS.
7. E-POWER (CRITICAL BRANCH) BRANCH CIRCUIT CONNECTIONS TO PRE-MANUFACTURED
'PBPU' HEADWALL. MAKE REQUIRED CONNECTIONS TO THE HEADWALL UNIT AS
REQUIRED - SPLIT THE RECEPTACLES EVENLY AMONG THE 2 CIRCUITS. COORDINATE
WITH ARCHITECT FOR ROUGH-IN LOCATION AND CONNECTION REQUIREMENTS.
HEADWALL IS FURNISHED BY OTHERS AND CONNECTIONS BY ELECTRICAL. REFER TO
ARCHITECTURAL HEADWALL ELEVATIONS FOR DETAILS OF HEADWALL
CONFIGURATIONS.
8. POWER CONNECTION TO OVER-HEAD LIFT CONVEYANCE SYSTEM. COORDINATE WITH
ARCHITECT FOR ROUGH-IN LOCATION AND CONNECTION REQUIREMENTS.
9. COORDINATE ROUGH-IN HEIGHTS AT CHARTING STATION WITH ARCHITECT.
10. COORDINATE MOUNTING HEIGHT OF MONITOR DUPLEX RECEPTACLE WITH ARCHITECT
PRIOR TO ROUGH-IN.
11. TWELVE (12) 1-1/4" CONDUITS RAN ABOVE ACCESSIBLE CEILING FOR PART 2B CIRCUITS.
COORDINATE ROUTING WITH ALL EXISTING ABOVE CEILING UTILITIES. CONFIRM
ROUTING WITH VA COR. PROVIDE WITH PULL STRINGS.
12. TWO (2) 2" CONDUITS RAN ABOVE ACCESSIBLE CEILING FOR PART 2B CIRCUITS.
COORDINATE ROUTING WITH ALL EXISTING ABOVE CEILING UTILITIES. CONFIRM
ROUTING WITH VA COR. PROVIDE WITH PULL STRINGS.
FLOOR PLAN NOTES
##E
B
B
B
B
B
B
B
B
J
B
B
J
BB
B
V1-845B
NURSE
STATION
V1-624
TREATMENT
ROOM-7
V1-626
TREATMENT
ROOM-8
V1-628
DOCTORS
WORK
V1-627
ELECTRICAL
V1-632A
PATIENT
TOILET
V1-632
TREATMENT
ROOM-9
V1-630
PATIENT
TOILET
V1-625
ANTE
ROOM
V1-845A
NURSE
STATION
V1-845
MEDS
C1-76
CORRIDOR
C1-62A
CORRIDOR
C1-62B
CORRIDOR
C1-77
CORRIDOR
V1-800
ED WAITING ROOM
S18
STAIRWELL
NO.18
RN1B
RC1A
RC1A
01E
03E
02E
04E
J
J
J
J J
J
JJ
J
05E
06E07E
08E
09E
(TYP)
RN1A
(TYP)
(TYP)
(TYP)
RC1B
RN1A
RN1A
RN1A
RN1A
RN1A
RC1B
18 20
RC1B
RC1B
RN1A
RN1A
10E
RE1A
12E
11E
(TYP 12)
03E
RN1A
RN1A
RN1A
RN1A
RN1A
V1-845B
NURSE
STATION
V1-624
TREATMENT
ROOM-7
V1-626
TREATMENT
ROOM-8
V1-628
DOCTORS
WORK
V1-627
ELECTRICAL
V1-632A
PATIENT
TOILET
V1-632
TREATMENT
ROOM-9
V1-630
PATIENT
TOILET
V1-625
ANTE
ROOM
V1-845A
NURSE
STATION
V1-845
MEDS
C1-76
CORRIDOR
C1-62A
CORRIDOR
C1-62B
CORRIDOR
C1-77
CORRIDOR
V1-844
TREATMENT
ROOM-3
V1-840
SHOWER
TOILET
TREATMENT
ROOM-2
TREATMENT
ROOM-1
V1-837
BIOMED
CLOSET
V1-800
ED WAITING ROOM
V1-842 V1-838
S18
STAIRWELL
NO.18
C1-62C
CORRIDOR
V1-668
NOURISHMENT
V1-834
ELECT
ROOM
Lankford Fendler a s s o c i a t e s
BLDG 26
BLDG 1
BLDG
PHASE II
N
Revisions
Drawing Name: P:\18.5800\18.5833.00_KCVAMC-Emergency Dept-Remodel Phase II\Drawings\PHASE 2 DRAWINGS\18.5833.00EP101.dwg Jul 25,2019 - 5:23pm
Date
Drawing Title:
Scale:
Approved:
Sheet of
Building Number:
Location:
Project Title:
Checked By:
DRAWING NO.
Project No.
Drawn By:
Date:
D e p a r t m e n t o f
V e t e r a n s
A f f a i r s
589-396
CONSULTANTS:ARCHITECT:
8/10/2018
EMERGENCY ROOM EXPANSION, PHASE IIB
KANSAS CITY VA MEDICAL CENTER
4801 Linwood Blvd
Kansas City , MO 64128
Kansas City VA Medical Center
4801 Linwood Blvd, Kansas City, MO 64128
95% DESIGN REVIEW 05/31/2018
STRUCTURAL ENGINEER
BOB D. CAMPBELL AND COMPANY
4338 BELLEVIEW AVENUE
KANSAS CITY, MO 64111
(816) 531-4144
INDUSTRIAL HYGIENIST
TITAN ENVIRONMENTAL SERVICES
2418 MERRIAM LANE
KANSAS CITY, KS. 66106
(913) 432-5500
MEP & FP ENGINEER
LANKFORD | FENDER & ASSOCIATES
1730 WALNUT
KANSAS CITY, MO. 64108
(816) 221-1429
100% CONSTRUCTION DOCS REVIEW SUBMITTAL 8/10/2018
100% CONSTRUCTION DOCUMENTS
Phone: 816.221.1411 | Fax: 816.221.1429
1730 Walnut Street Kansas City, Missouri 64108 1915 Frederick Avenue, St. Joseph, Missouri 64501
COA No.
Lankford Fendler a s s o c i a t e s
COPYRIGHT C 2018
LANKFORD | FENDLER + ASSOCIATES, CONSULTING ENGINEERS, INC.
Project No.
2006001168
18.5833.00
100% CONSTRUCTION DOCS REVISIONS TO BUDGET 7/19/2019
EP101SMPJOB
FIRST FLOOR PLAN-POWER
40 48
| 2019.07.25 ED Phase IIB Revisions |
| 33_PD201 |
| 18.5833.00PD201-33_PD201 |
| 34_PL101 |
| 18.5833.00PL101-34_PL101 |
| 35_PL201 |
| 18.5833.00PL201-35_PL201 |
| 37_FP101 |
| 37_FP101 |
| 38_EG000 |
| 18.5833.00EG000-38_EG000 |
| 39_ED101 |
| 39_ED101 |
| 40_EP101 |
| 40_EP101 |