SEISMIC BRACING NOTES

SOME MECHANICAL AND PLUMBING COMPONENTS OF THIS

BUILDING REQUIRE SEISMIC BRACING. IT IS THE

RESPONSIBILITY OF THIS CONTRACTOR AND THE GC TO

ENGAGE A SEISMIC DESIGN ENGINEER TO DETERMINE AND

DESIGN THE REQUIRED BRACING FOR EACH SYSTEM.

SYSTEMS REQUIRING BRACING INCLUDE, BUT ARE NOT

LIMITED TO, THE FOLLOWING:

1. ALL LIFE-SAFETY COMPONENTS INCLUDING FIRE

PROTECTION SYSTEMS.

2. COMPONENTS WEIGHING MORE THAN 400 POUNDS.

3. COMPONENTS WITH A CENTER OF MASS GREATER

THAN 4 FEET ABOVE FLOOR LEVEL AND WEIGHING

MORE THAN 20 POUNDS (E.G. TERMINAL UNITS).

4. DISTRIBUTION SYSTEMS WEIGHING MORE THAN 5

POUNDS PER FOOT. (E.G. 12x12, 22 GAUGE, SHEET

STEEL DUCTWORK AND CHILLED, HEATING,

DOMESTIC HOT, AND DOMESTIC COLD WATER PIPING

LARGER THAN 1 1/2".

FLEXIBLE CONNECTIONS ARE REQUIRED BETWEEN ALL

COMPONENTS AND ASSOCIATED DUCTWORK, PIPING, AND

CONDUITS.

THE FOLLOWING COMPONENTS ARE NOT REQUIRED TO BE

BRACED:

1. PLUMBING FIXTURES

THE CONTRACTOR SHALL PROVIDE ALL COMPONENT

SUBMITTALS WITH COMPONENT WEIGHTS TO SEISMIC

DESIGN ENGINEER FOR USE IN BRACING DESIGN.

BRACING SHALL BE DESIGNED TO MEET ASCE 7 AND NFPA 13

BRACING REQUIREMENTS. REFER TO ASCE 7 CHAPTER 13

FOR MORE INFORMATION ON SYSTEMS REQUIRED TO BE

BRACED.

GENERAL DEMOLITION NOTES

1. VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING

WORK. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND

NOTES TO THE ARCHITECT IMMEDIATELY. MINOR CHANGES IN

THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN

ADDITIONAL COST.

2. REMOVAL OF EXISTING FIXTURES AND EQUIPMENT WILL

REQUIRE ISOLATING THE PIPING RISERS OR MAINS VIA SHUT-

OFF VALVES. INSTALL NEW ISOLATION VALVES WHERE

REQUIRED FOR COMPLETION OF WORK.

3. REMOVAL OF EXISTING PLUMBING FIXTURES AND EQUIPMENT,

ETC. WILL REQUIRE CAPPING AND SEALING EXISTING MAINS

OR BRANCHES AS NECESSARY AND REQUIRED TO ALLOW THE

REMAINING SYSTEMS TO FULLY OPERATE WITHOUT

DEGRADATION. CONTRACTOR SHALL PROVIDE PROTECTIVE

PLASTIC DROP CLOTHS TO PROTECT THE EXISTING OCCUPIED

AREAS AND EQUIPMENT FROM DUST AND DEBRIS DURING THE

CONSTRUCTION WORK, AND SHALL CLEAN THE AREAS OF ALL

CONSTRUCTION DIRT DAILY, AND UPON COMPLETION OF THE

WORK. REFER TO GENERAL CONDITIONS AND DIVISION 1

SECTIONS IN THE SPECIFICATIONS.

4. ALL DRAINED PIPING RISERS AND MAINS SHALL BE REFILLED

WITH PROPER FLUID AND PROPERLY VENTED BY THIS

CONTRACTOR, ONCE NEW WORK HAS BEEN INSTALLED.

5. COORDINATE WITH GENERAL CONTRACTOR THE REMOVAL

AND REPLACEMENT OF ALL EXISTING CEILINGS, WALLS, ETC.

AS REQUIRED FOR MECHANICAL DEMOLITION WORK.

6. EXISTING PIPING AND EQUIPMENT, ETC., NOT TO BE UTILIZED

IN THE COMPLETED BUILDING SHALL BE DISCONTINUED OR

REMOVED AS REQUIRED. ALL ENDS OF DISCONTINUED PIPING

SHALL BE CAPPED IN THE NEAREST WALL, CEILING OR FLOOR

SO THAT THEY ARE COMPLETELY CONCEALED. OPENINGS

LEFT IN WALLS, CEILINGS, ETC., WHERE EQUIPMENT AND PIPE,

ETC., ARE REMOVED AND NOT REPLACED, SHALL BE PATCHED

NEATLY WITH SIMILAR MATERIAL TO ADJACENT

CONSTRUCTION. REFER TO DRAWINGS DELINEATING NEW

WORK FOR ADDITIONAL INFORMATION REGARDING SYSTEMS

OR PORTIONS OF SYSTEMS WHERE USE IS TO BE

DISCONTINUED.

7. EXISTING PIPING, FIXTURES AND EQUIPMENT THAT ARE NOT

TO BE REUSED SHALL BE REMOVED AND SHALL REMAIN THE

PROPERTY OF THE OWNER IF THEY WISH TO RETAIN

OWNERSHIP OF SAME. IF NOT, EQUIPMENT SHALL BECOME

THE PROPERTY OF THIS CONTRACTOR AND SHALL BE

REMOVED FROM THE SITE AS SOON AS PRACTICAL AND

DISPOSED OF IN ACCORDANCE WITH APPLICABLE LAWS AND

REGULATIONS.

8. ALL CUTTING AND CHANNELING OF EXISTING BUILDING SHALL

BE ACCOMPLISHED IN A NEAT AND WORKMANLIKE MANNER

WITHOUT REMOVAL OF EXCESS MATERIALS. THIS

CONTRACTOR SHALL PATCH AND REPLACE WITH MATERIAL

SIMILAR TO ADJACENT CONSTRUCTION.

9. WHERE EXISTING PIPING AND EQUIPMENT, ETC., THAT ARE TO

BE UTILIZED IN THE COMPLETED PROGRAM CONFLICT WITH

NEW CONSTRUCTION AND THE REQUIRED DEMOLITION, THEY

SHALL BE RELOCATED AND RECONNECTED TO MAINTAIN THE

DESIRED SERVICE.

10. PORTIONS OF EXISTING SYSTEMS MAY BE SHOWN FOR

CLARITY EVEN THOUGH IT MAY NOT BE NECESSARY TO

MODIFY OR REVISE THEM. ALL EXISTING SYSTEMS ARE

SHOWN BASED ON ORIGINAL OR REMODEL BUILDING

DRAWINGS. CONTRACTOR TO VERIFY ALL EXISTING

CONDITIONS.

11. ALL WORK MUST BE COORDINATED AND SCHEDULED WITH THE

OWNER AND OCCUPANTS OF THIS BUILDING SO AS TO

PROVIDE THE LEAST AMOUNT OF DISRUPTION OF BUILDING

ACTIVITIES AS POSSIBLE.ALL ACCESSIBLE ABANDONED PIPING

AND DUCTWORK SHALL BE REMOVED AND PROPERLY

DISPOSED OF.

GENERAL NOTES

1. VERIFY JOB SITE CONDITIONS AND DIMENSIONS BEFORE

BEGINNING WORK. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE INFORMATION.

CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. NO PIPING, DUCTWORK, ETC. SHALL PENETRATE STRUCTURAL

MEMBERS.

3. PROVIDE MISCELLANEOUS CUTTING, PATCHING AND

REPAIRING OF FINISHES, ROOF, WALLS, ETC., AS REQUIRED TO

ACCOMMODATE THE NEW WORK.

4. G.C. IS TO PATCH ANY OPENINGS IN CORRIDORS REQUIRED TO

BE CONSTRUCTED TO LIMIT THE TRANSFER OF SMOKE AND IN

SMOKE BARRIERS AS REQUIRED TO MEET CODE

REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR

LOCATIONS.

5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY

EXACT LOCATION, CONFIGURATION AND ROUTING OF

EXISTING SYSTEMS REQUIRED TO REMAIN IN OPERATION

DURING THE PROJECT TO PREVENT DAMAGE DURING

DEMOLITION AND PHASING.

6. REMOVE ALL EXISTING EQUIPMENT, DUCTWORK AND PIPING

THAT IS NOT REQUIRED FOR A WORKING INSTALLATION.

7. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO

INSTALLATION.

8. ALL CUTTING AND PATCHING SHALL BE CLOSELY

COORDINATED WITH THE G.C.

9. COORDINATE ROUTING OF PLUMBING, AND HVAC PIPING WITH

DUCTWORK, LIGHTS, ARCHITECTURAL CEILING AND

STRUCTURAL ELEMENTS. PIPING SHALL RISE AND DROP, JOG

OR OFFSET AS REQUIRED TO AVOID CONFLICTS. DUCTWORK

SHALL TAKE PRECEDENCE OVER ALL PIPING, EXCEPT WHERE

GRADE MUST BE MAINTAINED FOR DRAINAGE. REWORK OF

INSTALLED WORK TO RESOLVE CONFLICTS RISING FROM LACK

OF COORDINATION SHALL NOT JUSTIFY AN INCREASE IN THE

CONTRACT AMOUNT.

10. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL

BE FIRE STOPPED BY THE TRADE MAKING THE PENETRATION.

REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS

FOR REQUIREMENTS.

11. DO NOT ROUTE PIPING OR DUCTWORK OVER ELECTRICAL

PANELS OR EQUIPMENT. PIPING OR DUCTWORK SHALL NOT

BE ROUTED THROUGH ELECTRICAL ROOMS, TELECOM ROOMS,

OR ELEVATOR EQUIPMENT ROOMS UNLESS SPECIFICALLY

SERVING THAT ROOM. COORDINATE WITH E.C. PROVIDE

WATERTIGHT DRIP PAN WITH DRAIN TO NEAREST APPROVED

RECEPTOR WHERE REQUIRED.

12. COORDINATE SIZE AND LOCATION OF ACCESS DOORS IN

CONSTRUCTION REQUIRED FOR ACCESS TO MECHANICAL

EQUIPMENT WITH G.C.

13. ALL WORK IS TO CONFORM WITH APPLICABLE CODES AND

STANDARDS.

14. COORDINATE ACCESS TO EQUIPMENT AND VALVES INSTALLED

ABOVE 'HARD' CEILINGS AND IN MASONRY CHASES WITH

GENERAL CONTRACTOR. PROVIDE LOCKING ACCESS DOORS

FOR INSTALLATION BY CONTRACTOR AS REQUIRED TO

SERVICE CONCEALED DAMPERS, VALVES AND EQUIPMENT.

15. REFER TO ARCH FOR PHASING PLAN AND ALLOWABLE WORK

HOURS.

16. THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS.

REFER TO SPECIFICATIONS FOR FURTHER INFORMATION.

17. COMPLETE COORDINATION OF DRAWINGS SHALL BE

REQUIRED BY PARAGRAPH "SUBMITTAL" IN SPECIFICATION

SECTION 220511. CONSTRUCTION SHALL NOT START ON ANY

SYSTEM UNTIL THE COORDINATION DRAWINGS HAVE BEEN

APPROVED BY VA.

18. THIS IS A LIFE SAFETY BUILDING WHICH MEANS IT SHALL

REMAIN REASONABLY OPERATIONAL IN THE CASE OF A

SEISMIC EVENT. THEREFORE ALL STATIONARY EQUIPMENT ON

THE FLOOR SHALL BE FIXED RIGIDLY TO THE STRUCTURE. ALL

HANGING PIPING SHALL BE BRACED TO THE STRUCTURE.

REFER TO SPECIFICATION SECTION 130541.

19. PIPE LENGTH FROM RECIRCULATED HOT WATER MAIN TO

LAVATORY HOT WATER STOP SHALL BE NO MORE THAN 15'-6".

20. PIPE LENGTH FROM COLD WATER MAIN TO WATER CLOSET

FLUSH VALVE SHALL BE NO MORE THAN 19'-6".

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PP001

PLUMBING NOTES AND SYMBOLS

JAC JGA04/26/2018

SHEET LIST

PP001 PLUMBING NOTES AND SYMBOLS

PD101 PLUMBING DEMOLITION PLAN - FIRST FLOOR

PD102 PLUMBING DEMOLITION PLAN - SECOND FLOOR

PD102.3 PLUMBING DEMOLITION PLAN - SECOND FLOOR - BID ITEM #3

PD102.4 PLUMBING DEMOLITION PLAN - SECOND FLOOR - BID ITEM #4

PD103 PLUMBING DEMOLITION PLAN - THIRD FLOOR

PD103.3 PLUMBING DEMOLITION PLAN - THIRD FLOOR - BID ITEM #3

PD103.4 PLUMBING DEMOLITION PLAN - THIRD FLOOR - BID ITEM #4

PD111 MEDICAL GAS DEMOLITION PLAN - FIRST FLOOR

PD112 MEDICAL GAS DEMOLITION PLAN - SECOND FLOOR

PD113 MEDICAL GAS DEMOLITION PLAN - THIRD FLOOR

PD113.3 MEDICAL GAS DEMOLITION PLAN - THIRD FLOOR - BID ITEM #3

PD113.4 MEDICAL GAS DEMOLITION PLAN - THIRD FLOOR - BID ITEM #4

PL101 PLUMBING PLAN - FIRST FLOOR

PL102 PLUMBING PLAN - SECOND FLOOR

PL102.3 PLUMBING PLAN - SECOND FLOOR - BID ITEM #3

PL102.4 PLUMBING PLAN - SECOND FLOOR - BID ITEM#4

PL103 PLUMBING PLAN - THIRD FLOOR

PL103.3 PLUMBING PLAN - THIRD FLOOR - BID ITEM #3

PL103.4 PLUMBING PLAN - THIRD FLOOR - BID ITEM #4

PL111 MEDICAL GAS PLAN - FIRST FLOOR

PL112 MEDICAL GAS PLAN - SECOND FLOOR

PL113 MEDICAL GAS PLAN - THIRD FLOOR

PL113.3 MEDICAL GAS PLAN - THIRD FLOOR - BID ITEM #3

PL113.4 MEDICAL GAS PLAN - THIRD FLOOR - BID ITEM #4

PL201 WASTE AND VENT RISER

PL202 DOMESTIC WATER RISER

PL401 PLUMBING DETAILS

PL501 PLUMBING SCHEDULES

No. Description Date

1-E

1-51-31-21-1

1-H

1-J

1A-A

1-M

1-N

1-Q

1A-D

1A-C

1A-B

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

A

A

A

A

A A

A

A A

A

A

A

A

A

A

A

A

A

A

A

A

A

(E X

)2

(EX)4"W

(E X

)2

(E X

)4 "W

(E X

)4 "W

(EX)2"W

(E X

)2 "W

(E X

)4 "W

(EX)2"

A

A

CAP ABOVE CEILING

(E X

)2 "W

(EX)3"CW & 2"HW RISERS TO REMAIN

(EX)4"W

(E X

)4 "W

REMOVE (EX) WASTE LINE ABOVE CEILING. CAP AT MAIN

THIS AREA HAS A "HARD" ARCHED CEILING

A

(EX)3"V RISER

REMOVE (EX) 1/2"HWC RISER UP. 1/2"HWC DOWN TO REMAIN

REMOVE (EX) 2"V RISER

(EX)2"V

(E X

)2 "V

REMOVE (EX) 2"V RISER

A. REMOVE (EX) WASTE LINE UP TO

FIXTURE BEING REMOVED OR TO

ROUGH-INS OF FIXTURES PREVIOUSLY

REMOVED.

PLAN NOTES

PHASE 1

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

5. ALL FIRST FLOOR CEILINGS ARE

ACCESSIBLE, LAY-IN TILE WITH THE

EXCEPTION OF AREA DESIGNATED WITH

SHADING.

6. THREE EXISTING VENT RISERS SERVING

FIRST FLOOR FIXTURES ARE SHOWN.

MORE MAY EXIST. FIELD VERIFY VENTING

PRIOR TO DEMOLITION AND REROUTE AS

NECESSARY.

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD101

PLUMBING DEMOLITION PLAN - FIRST

FLOOR

JAC JGA04/26/2018

1/4" = 1'-0"

PLUMBING DEMOLITION PLAN - FIRST FLOOR

2' 4' 8'0'

1/4" = 1'-0"

N

A

A

A

A

A

A

A A

A

1-E

1-51-31-21-1

1-H

1-J

1A-A

1-M

1-N

1-Q

1A-D

1A-C

1A-B

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

B

A

B

B

B

B

C

B

C

B

B

B

B

B

B

B

B

B

B

B

B B

B

B

B

(EX)1/2"

(E X

)1 /2

(E X

)1 /2

(EX)2"

(E X

)2

(EX)1"

(EX)1"

(EX)1 1/2"

(E X

)1

(E X

)2

(E X

)1 /2

(EX)1 1/2"

(E

X )2

(EX)3/4"(EX)3/4"(EX)1/2"

(E X

)1

(E X

)2

(E X

)1 /2

(EX)1/2"

(EX)1 1/2"

(EX)2 1/2"

(E X

)1

/2

(E X

)2

(E X

)1 /2

(EX)2"(EX)2" (EX)1"

(EX)4"

(E X

)3 /4

(E

X )3

/4

(E X

)1 /2

(E X

)2

(EX)2" (EX)3/4"

(EX)3/4" (EX)1/2"

(E X

)1

/2

(EX)2"

(EX)1 1/4"

(EX)1 1/2" (EX)2 1/2" (EX)1 1/4" (EX)1" (EX)2"

(E X

)2

(EX)2"

(EX)2"

(E X

)2

(EX)3"

(E X

)4

B

C C

C C

C

B

B

C

C

C

C

C

(EX)GATE VALVES

(EX)3"CW & 2"HW RISERS

TO REMAIN

A

C

C

A

REMOVE VENT PIPING TO MAIN AND CAP, APPROX. 45 FT.

REMOVE HW & CW PIPING TO

MAIN AND CAP, APPROX. 95 FT.

(EX)3"V RISER

REMOVE (EX)

1/2" HWC RISER

A. REMOVE (EX) PLUMBING FIXTURE AND

ASSOCIATED PIPING - CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

B. REMOVE (EX) WASTE LINE UP TO

FIXTURE BEING REMOVED OR TO

ROUGH-INS OF FIXTURES PREVIOUSLY

REMOVED.

C. REMOVE PIPING FOR FIXTURES

PREVIOUSLY REMOVED. CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

PLAN NOTES

PHASE 1

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD102

PLUMBING DEMOLITION PLAN - SECOND

FLOOR

JAC JGA04/26/2018

1/4" = 1'-0"

PLUMBING DEMOLITION PLAN - SECOND FLOOR

2' 4' 8'0'

1/4" = 1'-0"

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

A

A

A

A

A

A

A A

A

A

B

A

B

B

B

B

C

B

C

B

B

B

B

B

B

B B

B

B

B

(EX)1/2"

(E X

)1 /2

(E X

)1 /2

(EX)1"

(EX)1"

(EX)1 1/2"

(E X

)1

(E X

)2

(E X

)1 /2

(EX)1 1/2"

(EX)3/4"(EX)3/4"(EX)1/2"

(E X

)1

(E X

)2

(E X

)1 /2

(EX)1/2"

(EX)1 1/2"

(EX)2 1/2"

(E X

)1

/2

(E X

)2

(E X

)1 /2

(EX)2"(EX)2" (EX)1"

(E X

)3 /4

(E

X )3

/4

(E X

)1 /2

(E X

)2

(EX)2" (EX)3/4"

(EX)3/4" (EX)1/2"

(E X

)1

/2

(EX)2"

(EX)1 1/4"

(EX)1 1/2" (EX)2 1/2" (EX)1 1/4" (EX)1" (EX)2"

(E X

)2

(EX)2"

(E X

)2

(EX)3"

(E X

)4

B C C

C C

C

B

B

C

C

C

C

C

(EX)GATE VALVES

(EX)3"CW & 2"HW RISERS

TO REMAIN

A

C

C

A

REMOVE VENT PIPING TO MAIN AND CAP, APPROX. 45 FT.

REMOVE HW & CW PIPING TO

MAIN AND CAP, APPROX. 95 FT.

REMOVE (EX)

1/2"HWC RISER

D

D

D

D

D

(EX)4"W TO REMAIN

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

A. REMOVE (EX) PLUMBING FIXTURE AND

ASSOCIATED PIPING - CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

B. REMOVE (EX) WASTE LINE UP TO

FIXTURE BEING REMOVED OR TO

ROUGH-INS OF FIXTURES PREVIOUSLY

REMOVED.

C. REMOVE PIPING FOR FIXTURES

PREVIOUSLY REMOVED. CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

D. EXISTING WASTE LINE UP TO EXISTING

FIXTURE TO REMAIN.

PLAN NOTES

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD102.3

PLUMBING DEMOLITION PLAN - SECOND

FLOOR - BID ITEM #3

JAC JGA04/26/2018

1/4" = 1'-0"

PLUMBING DEMOLITION PLAN - SECOND FLOOR - BID ITEM #3

2' 4' 8'0'

1/4" = 1'-0"

PHASE 1 BID ITEM #4

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

A. REMOVE (EX) PLUMBING FIXTURE AND

ASSOCIATED PIPING - CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

B. REMOVE (EX) WASTE LINE UP TO

FIXTURE BEING REMOVED OR TO

ROUGH-INS OF FIXTURES PREVIOUSLY

REMOVED.

C. REMOVE PIPING FOR FIXTURES

PREVIOUSLY REMOVED. CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

D. EXISTING WASTE LINE UP TO EXISTING

FIXTURE TO REMAIN.

PLAN NOTES

1-E

1-51-31-21-1

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

A

A

A

A

A

A

A A

A

A

B

A

B

B

D

D

C

D

C

D

D

D

D

D

D

D D

B

D

D

(EX)1/2"

(E X

)1 /2

(E X

)1 /2

(EX)1"

(EX)1"

(EX)1 1/2"

(E X

)1

(E X

)2

(E X

)1 /2

(EX)1 1/2"

(EX)3/4"(EX)3/4"(EX)1/2"

(E X

)1

(E X

)2

(E X

)1 /2

(EX)1/2"

(EX)1 1/2"

(EX)2 1/2"

(E X

)1

/2

(E X

)2

(E X

)1 /2

(EX)2"(EX)2" (EX)1"

(E X

)3 /4

(E

X )3

/4

(E X

)1 /2

(E X

)2

(EX)2" (EX)3/4"

(EX)3/4" (EX)1/2"

(E X

)1

/2

(EX)2"

(EX)1 1/4"

(EX)1 1/2" (EX)2 1/2" (EX)1 1/4" (EX)1" (EX)2"

(E X

)2

(EX)2"

(E X

)2

(EX)3"

(E X

)4

D C C

C

C

C

D

D

C

C

C

C

C

(EX)GATE VALVES

(EX)3"CW & 2"HW RISERS

TO REMAIN

A

C

D

A

REMOVE VENT PIPING TO MAIN AND CAP, APPROX. 45 FT.

REMOVE HW & CW PIPING TO

MAIN AND CAP, APPROX. 95 FT.

REMOVE (EX)

1/2"HWC RISER

D

D

D

D

D

D

C

D

B

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD102.4

PLUMBING DEMOLITION PLAN - SECOND

FLOOR - BID ITEM #4

JAC JGA04/26/2018

1/4" = 1'-0"

PLUMBING DEMOLITION PLAN - SECOND FLOOR - BID ITEM #4

2' 4' 8'0'

1/4" = 1'-0"

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

1-E

1-51-31-21-1

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-3A

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

(E X

)1

(E X

)2

(E X

)1 /2

(E

X )3

/4

(E X

)2

/2

(EX)3"

(E X

)1

/4

"(EX)1/2" (EX)2"

(EX)1 1/4"

(EX)2"

(E X

)3 /4

(E

X )1

(E

X )1

/2

(EX)1/2"(EX)1 1/2"

(EX)2 1/2"

(EX)2"(EX)2 1/2"

(EX)1 1/4"

(EX)1 1/2"

(EX)1/2"

(EX)2" (EX)1 1/4" (EX)1/2"

(EX)3" (EX)2 1/2"

(EX)2" (EX)3/4"(EX)3/4"

(EX)1/2"

(E X

)1 /2

(E

X )3

/4

(E X

)3 /4

(EX)1/2"(EX)2 1/2" (EX)1"

(EX)1/2"

(E X

)1

/2

(E X

)2

(EX)2"W (E

X

)2 "W

(E X

)2 "W

(E X

)2 "W

(EX)2"W

(EX)3"W

REMOVE FD

B

B

(EX)GATE VALVES

(EX)3"CW & 2"HW

RISERS TO REMAIN

(EX)3"VTR TO REMAIN

(EX)2-1/2"VTR TO REMAIN

(EX)4"VTR TO REMAIN

(EX)5"VTR TO REMAIN

(EX)3"V RISER

REMOVE (EX)

1/2"HWC DOWN

B

(EX)3"W

UP TO FD

B

A. REMOVE (EX) PLUMBING FIXTURE AND

ASSOCIATED PIPING - CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

B. REMOVE PIPING FOR FIXTURES

PREVIOUSLY REMOVED. CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

PLAN NOTES

PHASE 1

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD103

PLUMBING DEMOLITION PLAN - THIRD

FLOOR

JAC JGA04/26/2018

1/4" = 1'-0"

PLUMBING DEMOLITION PLAN - THIRD FLOOR

2' 4' 8'0'

1/4" = 1'-0"

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-3A

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

(EX)2"W (E

X

)2 "W

(E X

)2 "W

(E X

)2 "W

(EX)2"W

REMOVE FD

B

B

(EX)GATE VALVES

(EX)3"CW & 2"HW RISERS

TO REMAIN

(EX)3"VTR TO REMAIN

(EX)2-1/2"VTR TO REMAIN

(EX)4"VTR TO REMAIN

(EX)5"VTR TO REMAIN

A

C C

C C

C

B

B

(EX)3"W

UP TO FD

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

PHASE 1 BID ITEM #3

A. REMOVE (EX) PLUMBING FIXTURE AND

ASSOCIATED PIPING - CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

B. REMOVE PIPING FOR FIXTURES

PREVIOUSLY REMOVED. CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

C. EXISTING PLUMBING FIXTURE TO REMAIN.

PLAN NOTES

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD103.3

PLUMBING DEMOLITION PLAN - THIRD

FLOOR - BID ITEM #3

JAC JGA04/26/2018

1/4" = 1'-0"

PLUMBING DEMOLITION PLAN - THIRD FLOOR - BID ITEM #3

2' 4' 8'0'

1/4" = 1'-0"

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-3A

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

A

A

A

A

(EX)2"W (E

X

)2 "W

(E X

)2 "W

(E X

)2 "W

(EX)2"W(EX)GATE VALVES

(EX)3"CW, 2"HW & 1/2"HWC

RISERS TO REMAIN

(EX)3"VTR TO REMAIN

(EX)2-1/2"VTR TO REMAIN

(EX)4"VTR TO REMAIN

(EX)5"VTR TO REMAIN

(EX)3"V RISER

(EX)4"VTR TO REMAIN

FD TO REMAIN

A

PHASE 1 BID ITEM #4

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

A. REMOVE (EX) PLUMBING FIXTURE AND

ASSOCIATED PIPING - CAP AT MAINS

ABOVE CEILING OR BELOW FLOOR.

PLAN NOTES

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD103.4

PLUMBING DEMOLITION PLAN - THIRD

FLOOR - BID ITEM #4

JAC JGA04/26/2018

1/4" = 1'-0"

PLUMBING DEMOLITION PLAN - THIRD FLOOR - BID ITEM #4

2-1 2-2 2-32-4 2-5 2-6

2-J

2-K

1B-1

1B-A

1B-B

1B-C

1B-D

2-L

2-M

2-4A 2-6A

2-N

2-O

2-4B 2-6B

1-E

1-51-31-21-1

1-H

1-J

1A-A

1-M

1-N

1-Q

1A-D

1A-C

1A-B

1-T

1-V

1-W

1-U

1-3A

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

(EX)MA

(EX)VAC

(EX)O2

(EX)1 1/4"

(EX)2 1/2"

(EX)1 1/4"

REMOVE (EX)2 1/2" VAC,

1 1/4" 02 & 1 1/4" MA RISERS

SHUT-OFF VALVES ON MED

AIR AND VACUUM TO

ISOLATE BUILDING 1 -

SECOND, THIRD, AND

FOURTH FLOOR LOCATED

IN THIS ROOM. OXYGEN

SHUT-OFF IN BASEMENT.

COORDINATE WITH COR.

(EX)1 1/4"(EX)2 1/2"(EX)1 1/4"

(EX)MA

(EX)VAC

(EX)O2

(E X

)M A

(E X

)V A

C (E

X )O

(E X

)1

/4

(E X

)2

/2

(E X

)1

/4

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD111

MEDICAL GAS DEMOLITION PLAN - FIRST

FLOOR

JAC JGA04/26/2018

1/8" = 1'-0"

MEDICAL GAS DEMOLITION PLAN - FIRST FLOOR

4' 8' 16'

1/8" = 1'-0"

0'

REMOVE (EX) ZVB AND ALL

DOWNSTREAM PIPING.

REMOVE (EX) MEDICAL

GAS HEADWALL.

1-E

1-51-31-21-1

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

(EX)MA

(EX)VAC

(EX)O2

REMOVE (EX) 1-1/4"MA,

1-1/4"O2 & 2"VAC UP

(EX)MA

(EX)VAC

(EX)O2

(EX)1"

(EX)2" (EX)1"

(EX)MA

(EX)O2

REMOVE (EX) 1-1/4"MA,

1-1/4"O2 & 2"VAC DOWN

(EX) O2 & MA OUTLETS

TO REMAIN

REMOVE (EX) 1/2"O2 &

MA LINES ABOVE CEILING

PHASE 1

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

A. REMOVE (EX) MEDICAL GAS HEADWALL.

B. REMOVE (EX) ZONE VALVE BOX AND

ALL DOWNSTREAM PIPING.

C. REMOVE (EX) MEDICAL GAS ALARM

PANELS.

PLAN NOTES

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD112

MEDICAL GAS DEMOLITION PLAN -

SECOND FLOOR

JAC JGA04/26/2018

1/4" = 1'-0"

MEDICAL GAS DEMOLITION PLAN - SECOND FLOOR

2' 4' 8'0'

1/4" = 1'-0"

A. REMOVE (EX) MEDICAL GAS HEADWALL.

B. REMOVE (EX) ZONE VALVE BOX AND

ALL DOWNSTREAM PIPING.

C. REMOVE (EX) MEDICAL GAS ALARM

PANELS.

PLAN NOTES

A

A

A

A

A

A

A

A

A

A

A

A

C

1-E

1-51-31-21-1

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-3A

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

B

REMOVE (EX) 1-1/4"MA,

1-1/4"O2 & 2"VAC RISERS

(E)MA

(EX)VAC

(EX)O2

(E)MA

(EX)MV

(EX)O2

(E )M

A (E

X )V

A C

(E X

)O

(E )M

A

(E X

)M V

(E X

)O

A

A

A

A

A

A

(EX)MA

(EX)VAC

(EX)O2

(EX)1"VAC, 3/4"O2 & 3/4"MA UP TO REMAIN

(EX)1"

(EX)2"(EX)1"

A

PHASE 1

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD113

MEDICAL GAS DEMOLITION PLAN - THIRD

FLOOR

JAC JGA04/26/2018

1/4" = 1'-0"

MEDICAL GAS DEMOLITION PLAN - THIRD FLOOR

2' 4' 8'0'

1/4" = 1'-0"

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-3A

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

A

A

A

A

A

A

A

A

A

A

A

C

B

REMOVE (EX) 1-1/4"MA,

1-1/4"O2 & 2"VAC RISERS

(E)MA

(EX)VAC

(EX)O2

(E)MA

(EX)MV

(EX)O2

(E )M

A (E

X )V

A C

(E X

)O

(E )M

A

(E X

)M V

(E X

)O

A

A

A

A

(EX)MA

(EX)VAC

(EX)O2

(EX)1"VAC, 3/4"O2 & 3/4"MA UP TO REMAIN

(EX)1"

(EX)2"(EX)1"

(EX) MEDICAL GAS

HEADWALL TO

REMAIN (TYP)

(EX) MEDICAL GAS

HEADWALL TO

REMAIN (TYP)

A

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

A. REMOVE (EX) MEDICAL GAS HEADWALL.

B. REMOVE (EX) ZONE VALVE BOX AND

ALL DOWNSTREAM PIPING.

C. REMOVE (EX) MEDICAL GAS ALARM

PANELS.

PLAN NOTES

PHASE 1 BID ITEM #3

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD113.3

MEDICAL GAS DEMOLITION PLAN - THIRD

FLOOR - BID ITEM #3

JAC JGA04/26/2018

1/4" = 1'-0"

MEDICAL GAS DEMOLITION PLAN - THIRD FLOOR - BID ITEM #3

2' 4' 8'0'

1/4" = 1'-0"

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-3A

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

A

A

A

A

B

REMOVE (EX) 1-1/4"MA,

1-1/4"O2 & 2"VAC RISERS

(E)MA

(EX)VAC

(EX)O2

(E)MA

(EX)MV

(EX)O2

(E )M

A (E

X )V

A C

(E X

)O

(E )M

A

(E X

)M V

(E X

)O

A

(EX)MA

(EX)VAC

(EX)O2

(EX)1"VAC, 3/4"O2 & 3/4"MA UP TO REMAIN

(EX)1"

(EX)2"(EX)1"

A

(EX) AREA ALARMS TO REMAIN

C

C

C

C

C

C

C

C

C

C

C

C

C

PLUMBING DEMO NOTES

1. PLANS ARE SCHEMATIC IN NATURE.

LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL

FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND

DEMOLITION WORK SHALL BE CLOSELY

COORDINATED WITH THE EXISTING

CONDITIONS AND THE REQUIRED NEW

WORK. G.C. SHALL PATCH AND FINISH

PENETRATIONS OF EXISTING SPACES TO

MATCH ADJACENT SURFACES.

3. ALL PIPING TO BE REMOVED SHALL BE

CAPPED AT THE MAINS UNLESS

OTHERWISE NOTED.

4. ALL ACCESSIBLE ABANDONED PIPING

SHALL BE REMOVED.

A. REMOVE (EX) MEDICAL GAS HEADWALL.

B. REMOVE (EX) ZONE VALVE BOX AND ALL

DOWNSTREAM PIPING.

C. (EX) MEDICAL GAS HEADWALLS TO

REMAIN.

PLAN NOTES

PHASE 1 BID ITEM #4

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PD113.4

MEDICAL GAS DEMOLITION PLAN - THIRD

FLOOR - BID ITEM #4

JAC JGA04/26/2018

1/4" = 1'-0"

MEDICAL GAS DEMOLITION PLAN - THIRD FLOOR - BID ITEM #4 2' 4' 8'0'

1/4" = 1'-0"

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

(EX)4"W

(E X

)4 "W

(EX)2"W

(E X

)2 "W

(EX)4"W

(E X

)2 "W

B

D

A

D D A

A

BA

D

E D

B

C

AA

A

E

A

B

D

A

B

A

D

A

D

A

B

THIS AREA HAS A "HARD", ARCHED CEILING

E

2" W

2"W 2"W2"

W

E

2"W4"W

D

4" W

A

4" W

(EX)4"W

2" W

2" W

(E X

)4 "W

2"W

2"W

2"W

E

2"W

4"W

2"W

4" W

4"W

4" W

4" W

A

AD

D

E

A

4"W

2" W

2"W 4"W

E

(E X

)2 "W

A

E

A

A

B

2"W

2" W

2" W

2"W

2"PVC W

B

2"PVC W

A

4"CO

2" PVC W

E

4" W

2"PVC W

2"PVC W

E

B

2"PVC W

A

2"W

2"W

2"PVC W

B

2"PVC W

2"CO

2" W

A

2" PVC W

4"W

4" W

4"CO

4"CO

4" W

A

2" W

D A D

A

4" W

A

3"W

(E X

)4 "W

3"W UP

(EX)2"W

4"CO

(EX)3"V RISER

(EX) 3"CW & 2"HW RISERS TO REMAIN

CONNECT 1"HWC RISER TO

(EX) 1/2"HWC ABOVE CEILING

(EX)2"V

(E X

)2 "V

2"V UP INTO CHASE ABOVE

2"V UP

2"PVC W

(E X

)4 "W

PHASE 1

A. 2"W UP INTO WALL ABOVE

B. 2"W & 1-1/2"V UP TO SHOWER DRAIN

C. 3"W & 2"V UP TO MOP BASIN

D. 4"W UP INTO CHASE ABOVE

E. 2" PVC WASTE UP INTO WALL ABOVE

PLAN NOTES

1. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND DEMOLITION WORK SHALL BE CLOSELY COORDINATED

WITH THE EXISTING CONDITIONS AND THE REQUIRED NEW WORK. G.C. SHALL

PATCH AND FINISH PENETRATIONS OF EXISTING SURFACES TO MATCH ADJACENT

SURFACES.

3. FIELD VERIFY BEST ROUTING FOR NEW PIPING AND DUCTWORK. COORDINATE WITH

EXISTING EQUIPMENT, PIPING AND DUCTWORK. NEW PIPING SHALL RISE AND DROP,

JOG OR OFFSET AS REQUIRED TO AVOID CONFLICTS. DUCTWORK SHALL TAKE

PRECEDENCE OVER ALL PIPING, EXCEPT WHERE GRADE MUST BE MAINTAINED FOR

DRAINAGE. ANY EXPENSES RISING FROM LACK OF COORDINATION SHALL BE MADE

AT THE CONTRACTOR’S EXPENSE.

4. REFER TO ARCHITECTURAL SPECIFICATIONS AND PLANS FOR PHASING OF

DEMOLITION AND NEW WORK. ADJACENT AREAS ARE 100% OCCUPIED AND

CONTRACTOR SHALL WORK CLOSELY WITH OWNER TO SCHEDULE DEMOLITION AND

CONSTRUCTION TO BE AS LEAST DISRUPTIVE AS POSSIBLE.

5. ALL WORK SHALL BE DONE AT NIGHT AND/OR WEEKENDS, OR AS DIRECTED BY THE

COR.

6. ALL FIRST FLOOR CEILINGS ARE ACCESSIBLE, LAY-IN TILE WITH THE EXCEPTION OF

AREA DESIGNATED WITH SHADING.

7. WASTE AND VENT PIPING SHALL BE CAST IRON WITH NO-HUB FITTINGS AND

COUPLINGS EXCEPT WHERE SPECIFICALLY OTHERWISE INDICATED.

8. THREE EXISTING VENT RISERS SERVING FIRST FLOOR FIXTURES ARE SHOWN. MORE

MAY EXIST. FIELD VERIFY VENTING PRIOR TO DEMOLITION AND REROUTE AS

NECESSARY.

9. COMPLETE COORDINATION OF DRAWINGS SHALL BE REQUIRED BY PARAGRAPH

"SUBMITTAL" IN SPECIFICATION SECTION 220511. CONSTRUCTION SHALL NOT

START ON ANY SYSTEM UNTIL THE COORDINATION DRAWINGS HAVE BEEN

APPROVED BY VA.

GENERAL NOTES

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PL101

PLUMBING PLAN - FIRST FLOOR

JAC JGA04/26/2018

2' 4' 8'0'

1/4" = 1'-0"

N

1/4" = 1'-0"

PLUMBING PLAN - FIRST FLOOR

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

PATIENT ROOM

221-1

TOILET

220-1

SOILED UTILITY

218-1

TOILET

217-1

PATIENT ROOM

216-1

AIRBORNE INFECTION ISO.

PATIENT ROOM

214-1

TOILET

213-1

PATIENT ROOM

211-1

TOILET

209-1

PATIENT ROOM

208-1

PATIENT ROOM

204-1

BARIATRIC PATIENT ROOM

202-1

PATIENT ROOM

233-1

PATIENT ROOM

234-1

PATIENT ROOM

236-1

TOILET

232-1

ANTE RM

215-1

CHARTING

206-1

TOILET

238-1

RECEPTION

241-1

NURSE STATION

224-1

EXIST. STAIRS

2-STAIR-W

TOILET

210-1

TOILET

203-1

TOILET

205-1

CORR

200-1

CORR

201-1

CORR

225-1

CORR

212-1

CORR

219-1

CORR

207-1

STAFF TOILET

222-1

HSKPG

240-1

P-408

P-408

P-408

P-408

P-408

P-402

P-102

P-704

P-704

P-704

P-408

P-408

P-704

P-408

P-704

P-408

P-408

P-704

P-408

P-408

P-102

P-408

P-704

P-531

P-704

P-408

P-408

P-408

P-408

P-408

P-408 P-704

P-102

P-704

P-604

ELECT.

228-1

MEDICATION

230-1

NOURISH.

227-1

P-402

P-402

P-103

P-531

CLEAN UTILITY

231-1

EQUIP. STOR.

229-1

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-B

01007N

P-408 D

C W

DCW

D C

W D

C W

DCW

DCW

DCW

D C

W

DCW DCW

DCW

D C

W

D C

W

P-102

P-102

P-103

TOILET

235-1

TOILET

237-1

P-408

P-505

B

A

A

P-102

P-102

P-102

A

P-102

1/2"DCW DOWN TO BELOW CEILING,

VALVE, AND INSTALL HOSE BIBB.

SIMILAR TO DETAIL 2 THIS SHEET

(EX)GATE VALVES

(EX)3"CW & 2"HW

TO REMAIN SHALL

BE REINSULATED

P-809

P-809 P-809

P-809

P-809

P-809

P-809

P-809

P-809

E

E

E

2"W

2" W

C

E

E

E

E

A D

D

B

A

B

A

A

D

CAP 1/2"HWC ABOVE

CEILING FOR FUTURE

CAP 1-1/2"CW & 1"HW ABOVE CEILING

FOR FUTURE

A E

B

E

A

2"W

2" W

2" W

2" W

3"W

B

P-402

E

E

1 1/2"

3/ 4"

1/2"

3/4"3/4"

1/2"

1/2"

3/4"

1/ 2"

1 1/2" 1"

3/4"

3/ 4"

1/ 2"

1 1/4"2"1/ 2"

3/ 4"

1/ 2"

1/

2"

1 1/4"

1/2"1/2"

1/

4"

1 1/4" 2"

1"

1/ 2"

1/2"

1/2"

3"W

1 1/4"

2"

1/ 2"

3/ 4"

3/4"

2"

1/ 4"

1/

2" 1"

2" 1"

1 1/2"

1 1/2"

3/4"

2"

1/

2" 1"

1"

2"

1/ 4"

1/

2"

1/

4"

1" 1 1/4"

1 1/2"2"

2 1/2"3/4"

1 1/2"

1" 3/ 4"

3/ 4"

1 1/4"

1 1/2"

1/2"

1/

4"

2"PVC W

2"PVC W

2" PVC W

2"PVC W

2" PVC W

2" PVC W

2" PVC W

A

F

2" W

1 1/2"V

1/

2" V

1 1/2"V 1 1/2"V

2"V2"V

2"V UP

2" V

2"V UP

1/

2" V

2"V

1-1/2"V UP

1/

2" V

1/

2" V

1/

2" V

2" V

2"V UP

1/2"CW UP

CONNECT 1/2"CW TO FD

A

2" PVC W 2"PVC W

2"W

P-710

A

H

GH

G G

G

G

G

H

G

G

G

G

H

G

H

G

H

G G

H

G G

H

GG

P-809

A

B

B

B

B

BALANCE VALVE SET

FOR 2 GPM

2"W RUN IN WALL

4"W RUN IN CHASE

2" PVC W

4"W DOWN TO BLW. FLR.

2"W DOWN TO BLW. FLR.

SHOWER DRAIN LOCATION

A

3"W UP INTO WALL ABOVE

2"W DOWN

4"W DOWN

P-102

2"V DOWN

J

3/4"HWC UP,

1"HWC DOWN

J

1/ 2"

1/ 2"

(EX)3"V RISER

J

J

2"V DOWN

J

DCW

P-502

1"

3/ 4"

3/ 4"

3/4"

3/4"

3/4"

1"

1"

1"

3/4"

3/ 4"

3/ 4"

1"

3/4" 3/4" 1/2"

3/ 4"

D

D

1/ 2"

1/

2" V

K

1" RPZ

1 1/4"

1 1/4"

3/4"

3/4"

1"

DCW

D C

W D

C W

2"

1 1/4"

3/ 4"

3"W DOWN

1 1/4"

3/4"

1"

PHASE 1

A. 2"W UP INTO WALL ABOVE

B. 2"W & 1-1/2"V UP TO SHOWER DRAIN

C. 3"W & 2"V UP TO MOP BASIN

D. 4"W UP INTO CHASE ABOVE

E. 2" PVC WASTE UP INTO WALL ABOVE

F. 2"W UP TO FLOOR DRAIN ABOVE

G. 1-1/2"V UP INTO WALL ABOVE

H. 2"V UP INTO WALL ABOVE

PLAN NOTES

J. BALANCE VALVE SET FOR 0.5 GPM

K. 1/2" DRAIN LINE FROM RPZ TO ABOVE

DRAIN BOX IN WALL ABOVE CEILING. SEE

DETAIL 6/PL401

1. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND DEMOLITION WORK SHALL BE CLOSELY COORDINATED

WITH THE EXISTING CONDITIONS AND THE REQUIRED NEW WORK. G.C. SHALL

PATCH AND FINISH PENETRATIONS OF EXISTING SURFACES TO MATCH ADJACENT

SURFACES.

3. FIELD VERIFY BEST ROUTING FOR NEW PIPING AND DUCTWORK. COORDINATE WITH

EXISTING EQUIPMENT, PIPING AND DUCTWORK. NEW PIPING SHALL RISE AND DROP,

JOG OR OFFSET AS REQUIRED TO AVOID CONFLICTS. DUCTWORK SHALL TAKE

PRECEDENCE OVER ALL PIPING, EXCEPT WHERE GRADE MUST BE MAINTAINED FOR

DRAINAGE. ANY EXPENSES RISING FROM LACK OF COORDINATION SHALL BE MADE

AT THE CONTRACTOR’S EXPENSE.

4. REFER TO ARCHITECTURAL SPECIFICATIONS AND PLANS FOR PHASING OF

DEMOLITION AND NEW WORK. ADJACENT AREAS ARE 100% OCCUPIED AND

CONTRACTOR SHALL WORK CLOSELY WITH OWNER TO SCHEDULE DEMOLITION AND

CONSTRUCTION TO BE AS LEAST DISRUPTIVE AS POSSIBLE.

5. ALL WORK SHALL BE DONE AT NIGHT AND/OR WEEKENDS, OR AS DIRECTED BY THE

COR.

6. WATER PIPING SHALL BE INSTALLED AS INDICATED TO COMPLY WITH THE VA

PLUMBING DESIGN MANUAL. DEVIATION FROM ROUTING ONLY PERMISSIBLE BY

APPROVAL OF COR. IN ADDTION:

GENERAL NOTES

a. PIPE LENGTH FROM RECIRCULATED HOT WATER MAIN TO LAVATORY HOT

WATER STOP SHALL BE NO MORE THAN 15'-6".

b. PIPE LENGTH FROM COLD WATER MAIN TO WATER CLOSET FLUSH VALVE SHALL

BE NO MORE THAN 19'-6".

7. "DEDICATED COLD WATER" SHALL BE RUN IN POLYPROPYLENE PIPE AND FITTINGS.

LABEL "COLD WATER FOR DIALYSIS USE".

8. WASTE AND VENT PIPING SHALL BE CAST IRON WITH NO-HUB FITTINGS AND

COUPLINGS EXCEPT WHERE SPECIFICALLY OTHERWISE INDICATED.

9. COMPLETE COORDINATION OF DRAWINGS SHALL BE REQUIRED BY PARAGRAPH

"SUBMITTAL" IN SPECIFICATION SECTION 220511. CONSTRUCTION SHALL NOT

START ON ANY SYSTEM UNTIL THE COORDINATION DRAWINGS HAVE BEEN

APPROVED BY VA.

HOSE BIBB

DROP BELOW CEILING

SLOPE ALL DEDICATED COLD WATER

LINES TO DRAIN TOWARD HOSE BIBB

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PL102

PLUMBING PLAN - SECOND FLOOR

JAC JGA04/26/2018

2' 4' 8'0'

1/4" = 1'-0"

N

1/4" = 1'-0"

PLUMBING PLAN - SECOND FLOOR

NO SCALE

HYPOCHLORITE INJECTION PORT DETAIL

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

PATIENT ROOM

221-1

TOILET

220-1

SOILED UTILITY

218-1

TOILET

217-1

PATIENT ROOM

216-1

AIRBORNE INFECTION ISO.

PATIENT ROOM

214-1

TOILET

213-1

PATIENT ROOM

211-1

TOILET

209-1

PATIENT ROOM

208-1

PATIENT ROOM

204-1

BARIATRIC PATIENT ROOM

202-1

PATIENT ROOM

233-1

PATIENT ROOM

234-1

PATIENT ROOM

236-1

TOILET

232-1

ANTE RM

215-1

CHARTING

206-1

TOILET

238-1

RECEPTION

241-1

NURSE STATION

224-1

EXIST. STAIRS

2-STAIR-W

TOILET

210-1

TOILET

203-1

TOILET

205-1

CORR

200-1

CORR

201-1

CORR

225-1

CORR

212-1

CORR

219-1

CORR

207-1

STAFF TOILET

222-1

HSKPG

240-1

P-408

P-408

P-408

P-408

P-408

P-402

P-102

P-704

P-704

P-704

P-408

P-408

P-704

P-408

P-704

P-408

P-408

P-704

P-408

P-408

P-102

P-408

P-704

P-531

P-704

P-408

P-408

P-408

P-408

P-408

P-408 P-704

P-102

P-704

P-604

ELECT.

228-1

MEDICATION

230-1

NOURISH.

227-1

P-402

P-402

P-103 P-531

CLEAN UTILITY

231-1

EQUIP. STOR.

229-1

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-B

01007N

P-408

P-102

P-102

P-103

TOILET

235-1

TOILET

237-1

P-408

P-505

B

A

A

P-102

P-102

P-102

P-102

(EX)GATE VALVES

(EX)3"CW & 2"HW

TO REMAIN SHALL

BE REINSULATED

C

A

D

CAP 1/2"HWC ABOVE

CEILING FOR FUTURE

CAP 1-1/2"CW & 1"HW ABOVE CEILING

FOR FUTURE

A

B

A

B

P-402

1 1/2"

3/ 4"

1/2"

3/4"3/4"

1/2"

1/2"

3/4"

1/ 2"

1 1/2" 1"

3/4"

3/ 4"

1/ 2"

1 1/4"2"1/ 2"

3/ 4"

1/ 2"

1/

2"

1 1/4"

1/2"1/2"

1/

4"

1 1/4" 2"

1"

1/ 2"

1/2"

1/2"

1 1/4"

2"

1/ 2"

3/ 4"

3/4"

2"

1/ 4"

1/

2" 1"

2" 1"

1 1/2"

1 1/2"

3/4"

2"

1/

2" 1"

1"

2"

1/ 4"

1/

2"

1/

4"

1" 1 1/4"

1 1/2"2"

2 1/2"3/4"

1 1/2"

1" 3/ 4"

3/ 4"

1 1/4"

1 1/2"

1/2"

1/

4"

1 1/2"V 2"V2"V

CONNECT

TO (EX)2"V

UP

2"V UP

2"V

1-1/2"V UP

1/

2" V

2" V

2"V UP

A

2"W

P-710

A

H

GH

G G

G

G

G

H

G

G

G

G

H

G

H

G

H

G G

H

G G

H

GG

A

B

B

B

B

BALANCE VALVE SET

FOR 2 GPM

2"W RUN IN WALL

4"W RUN IN CHASE

4"W DOWN TO BLW. FLR.

2"W DOWN TO BLW. FLR.

SHOWER DRAIN LOCATION

3"W UP INTO WALL ABOVE

2"W DOWN

4"W DOWN

P-102

2"V DOWN

J

3/4"HWC UP,

1"HWC DOWN

J

1/ 2"

1/ 2"

(EX)3"V RISER

J

J

2"V DOWN

J

P-502

E

E E

E

E

4"W DOWN

1/2"DCW DOWN TO BELOW CEILING,

VALVE, AND INSTALL HOSE BIBB.

SIMILAR TO DETAIL 2 THIS SHEET

D C

W

DCW

1"

3/ 4"

DCW

3/ 4"

DCW

D C

W

3/4"

1"

1"

1"

DCW

D C

W

3/4"

3/ 4"

DCW

3/ 4"

3/4"

D C

W

DCW

P-809

P-809

P-809

3/4"

1"

D C

W

DCW

DCW

3/4"

P-809

DCW

D C

W

1/2"

DCW

3/ 4"

P-809

P-809

3/ 4"

P-809

P-809

3/ 4"

3/4" 3/4"

D C

W

DCW

P-809

P-809 DCW

D C

W

D

D

1/ 2"

1" RPZ

K

1/

2" V

F

F

F

2"W

2" W

F

F

F

2"PVC W

2" PVC W

2"PVC W

F

F

2" PVC W

2" PVC W

A F2" PVC W 2"PVC W

F

3/4"

1"

1 1/4"

2"

1 1/4"

3/4"

3/4"

1 1/4"

3"W DOWN

1 1/4"

1. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE

INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND

DIMENSIONS.

2. ALL CUTTING, PATCHING AND DEMOLITION WORK SHALL BE CLOSELY COORDINATED

WITH THE EXISTING CONDITIONS AND THE REQUIRED NEW WORK. G.C. SHALL

PATCH AND FINISH PENETRATIONS OF EXISTING SURFACES TO MATCH ADJACENT

SURFACES.

3. FIELD VERIFY BEST ROUTING FOR NEW PIPING AND DUCTWORK. COORDINATE WITH

EXISTING EQUIPMENT, PIPING AND DUCTWORK. NEW PIPING SHALL RISE AND DROP,

JOG OR OFFSET AS REQUIRED TO AVOID CONFLICTS. DUCTWORK SHALL TAKE

PRECEDENCE OVER ALL PIPING, EXCEPT WHERE GRADE MUST BE MAINTAINED FOR

DRAINAGE. ANY EXPENSES RISING FROM LACK OF COORDINATION SHALL BE MADE

AT THE CONTRACTOR’S EXPENSE.

4. REFER TO ARCHITECTURAL SPECIFICATIONS AND PLANS FOR PHASING OF

DEMOLITION AND NEW WORK. ADJACENT AREAS ARE 100% OCCUPIED AND

CONTRACTOR SHALL WORK CLOSELY WITH OWNER TO SCHEDULE DEMOLITION AND

CONSTRUCTION TO BE AS LEAST DISRUPTIVE AS POSSIBLE.

5. ALL WORK SHALL BE DONE AT NIGHT AND/OR WEEKENDS, OR AS DIRECTED BY THE

COR.

6. WATER PIPING SHALL BE INSTALLED AS INDICATED TO COMPLY WITH THE VA

PLUMBING DESIGN MANUAL. DEVIATION FROM ROUTING ONLY PERMISSIBLE BY

APPROVAL OF COR. IN ADDTION:

GENERAL NOTES

a. PIPE LENGTH FROM RECIRCULATED HOT WATER MAIN TO LAVATORY HOT

WATER STOP SHALL BE NO MORE THAN 15'-6".

b. PIPE LENGTH FROM COLD WATER MAIN TO WATER CLOSET FLUSH VALVE SHALL

BE NO MORE THAN 19'-6".

7. WASTE AND VENT PIPING SHALL BE CAST IRON WITH NO-HUB FITTINGS AND

COUPLINGS EXCEPT WHERE SPECIFICALLY OTHERWISE INDICATED.

8. COMPLETE COORDINATION OF DRAWINGS SHALL BE REQUIRED BY PARAGRAPH

"SUBMITTAL" IN SPECIFICATION SECTION 220511. CONSTRUCTION SHALL NOT

START ON ANY SYSTEM UNTIL THE COORDINATION DRAWINGS HAVE BEEN

APPROVED BY VA.

A. 2"W UP INTO WALL ABOVE

B. 2"W & 1-1/2"V UP TO SHOWER DRAIN

C. 3"W & 2"V UP TO MOP BASIN

D. 4"W UP INTO CHASE ABOVE

E. EXISTING WASTE LINE UP TO (EX)

PLUMBING FIXTURE

F. 2" PVC WASTE UP INTO WALL

PLAN NOTES

G. 1-1/2"V UP INTO WALL ABOVE

H. 2"V UP INTO WALL ABOVE

J. BALANCE VALVE SET FOR 0.5 GPM

K. 1/2" DRAIN LINE FROM RPZ TO ABOVE

DRAIN BOX IN WALL ABOVE CEILING. SEE

DETAIL 6/PL401

PHASE 1 BID ITEM #3

HOSE BIBB

DROP BELOW CEILING

SLOPE ALL DEDICATED COLD WATER

LINES TO DRAIN TOWARD HOSE BIBB

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

PL102.3

PLUMBING PLAN - SECOND FLOOR - BID

ITEM #3

JAC JGA04/26/2018

1/4" = 1'-0"

PLUMBING PLAN - SECOND FLOOR - BID ITEM #3

2' 4' 8'0'

1/4" = 1'-0"

N

No. Description Date

NO SCALE

HYPOCHLORITE INJECTION PORT DETAIL - BID ITEM#3

1-H

1-J

1-M

1-N

1-Q

1-T

1-V

1-W

1-U

1-6 1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

PATIENT ROOM

221-1

TOILET

220-1

SOILED UTILITY

218-1

TOILET

217-1

PATIENT ROOM

216-1

AIRBORNE INFECTION ISO.

PATIENT ROOM

214-1

TOILET

213-1

PATIENT ROOM

211-1

TOILET

209-1

PATIENT ROOM

208-1

PATIENT ROOM

204-1

BARIATRIC PATIENT ROOM

202-1

PATIENT ROOM

233-1

PATIENT ROOM

234-1

PATIENT ROOM

236-1

TOILET

232-1

ANTE RM

215-1

CHARTING

206-1

TOILET

238-1

RECEPTION

241-1

NURSE STATION

224-1

EXIST. STAIRS

2-STAIR-W

TOILET

210-1

TOILET

203-1

TOILET

205-1

CORR

200-1

CORR

201-1

CORR

225-1

CORR

212-1

CORR

219-1

CORR

207-1

STAFF TOILET

222-1

HSKPG

240-1

P-408

P-408

P-408

P-408

P-408

P-402

P-102

P-704

P-704

P-704

P-408

P-408

P-704 P-408

P-704

P-408

P-408

P-704

P-408

P-408

P-102

P-408

P-704

P-531

P-704

P-408

P-408

P-408

P-408

P-408

P-408 P-704

P-102

P-704

P-604

ELECT.

228-1

MEDICATION

230-1

NOURISH.

227-1

P-402

P-402

P-103 P-531

CLEAN UTILITY

231-1

EQUIP. STOR.

229-1

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-A

WHA-B

01007N

P-408

P-102

P-102

P-103

TOILET

235-1

TOILET

237-1

P-408

P-505

P-102

P-102

P-102

P-102

(EX)GATE VALVES

(EX)3"CW & 2"HW

TO REMAIN SHALL

BE REINSULATED

D

CAP 1/2"HWC ABOVE

CEILING FOR FUTURE

CAP 1-1/2"CW & 1"HW ABOVE CEILING

FOR FUTURE

P-402

1 1/2"

3/ 4"

1/2"

3/4" 3/4"

1/2"

1/2"

3/4"

1/ 2"

1 1/2" 1"

3/4"

3/ 4"

1/ 2"

1 1/4"2"1/ 2"

3/ 4"

1/ 2"

1/

2"

1 1/4"

1/2"1/2"

1/

4"

1 1/4" 2"

1"

1/ 2"

1/2"

1/2"

1 1/4"

2"

1/ 2"

3/ 4"

3/4"

2"

1/ 4"

1/

2" 1"

2" 1"

1 1/2"

1 1/2"

3/4"

2"

1/

2" 1"

1"

2"

1/ 4"

1/

2"

1/

4"

1" 1 1/4"

1 1/2"2"

2 1/2"3/4"

1 1/2"

1"

3/ 4"

3/ 4"

1 1/4"

1 1/2"

1/2"

1/

4"

E

1 1/2"V 2"V

2"V

1/

2" V

2" V

2"V UP INTO

WALL ABOVE

A

2"W

P-710

G G

H

A

B

BALANCE VALVE SET

FOR 2 GPM

2"W RUN IN WALL

4"W RUN IN CHASE

4"W DOWN TO BLW. FLR.

2"W DOWN TO BLW. FLR.

SHOWER DRAIN LOCATION

E

P-102

2"V DOWN

J

3/4"HWC UP,

1"HWC DOWN

J

1/ 2"

1/ 2"

(EX)3"V RISER

J

J

2"V DOWN

J

P-502

2"W

(EX)2"W

(EX)2"W

2"W

(EX)2"W

2" W

(EX)2"W

(EX)2"W

4" W

(EX)4"W

(EX)2"W

(EX)4"W

4" W

(E X

)2 "W

(EX)2"W 4"W

2"W

E

E

E

E

E

E

E

E

E

E

E

2"V

2" V

2"V

1 1/2"V

2"V

2" V

(EX)2-1/2"V UP

(EX)3"V UP

2" V

1 1/2"V

2" V

2" V

2"V

2" V

1 1/2"V

(EX)2"V UP

E

2" V

2" V

2"V 2"V

1 1/2"V

2" V

1/

2" V

(EX)2"V UP

2"W DOWN

4"W DOWN

E

2"V

2"V

E

E

4"W DOWN IN CHASE

4" W

E

E

(EX)2"W DOWN

E

E

E

4"W DOWN

2"W DOWN

4"W DOWN

E

E

D

D

1/ 2" K

1/

2" V

1" RPZ

F

F

2"W

2" W

1/2"DCW DOWN TO BELOW CEILING,

VALVE, AND INSTALL HOSE BIBB.

SIMILAR TO DETAIL 2 THIS SHEET

1" RPZ

1 1 /2"

V

D C

W

DCW

3/ 4"

3/4" 3/4"

D C

W

DCW

1/

2" V

3/ 4"

1"

3/ 4"

3/4"

DCW

DCW

1" 1"

D C

W

DCW 3/4"

D C

W

DCW

3/4"

1"

D C

W

DCW

1"

DCW

3/ 4"

3/4"

DCW

3/4"

D C

W

D C

W

3/…