About this file

36C25518R0522 04 Fire Protection Drawings.pdf

View the file

Other files

File Type Posted
36C25518R0522-023.pdf PDF
36C25518R0522-031.pdf PDF
36C25518R0522-032.pdf PDF
36C25518R0522-029.pdf PDF
36C25518R0522-027.pdf PDF
36C25518R0522-030.pdf PDF
36C25518R0522-024.pdf PDF
36C25518R0522-025.pdf PDF
36C25518R0522-026.pdf PDF
36C25518R0522-022.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1-E

1-51-31-21-1

1-H

1-J1A-A

1-M

1-N

1-Q1A-D

1A-C

1A-B

1-T

1-V

1-W

1-U

1-3A

1-6

1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

AREA NOT IN SCOPE

REMOVE AND RELOCATE FIRE

SPRINKLER HEADS TO PROVIDE

PROPER COVERAGE WITHIN THE

OUTLINED AREA.

PATIENT ROOM

221-1

TOILET

220-1

SOILED UTILITY

218-1

TOILET

217-1

PATIENT ROOM

216-1

AIRBORNE INFECTION ISO.

PATIENT ROOM

214-1

TOILET

213-1

PATIENT ROOM

211-1

TOILET

209-1

PATIENT ROOM

208-1

PATIENT ROOM

204-1

BARIATRIC PATIENT ROOM

202-1

MEDICATION

230-1

EQUIP. STOR.

229-1

PATIENT ROOM

233-1

PATIENT ROOM

234-1 PATIENT ROOM

236-1

TOILET

232-1

ANTE RM

215-1

CHARTING

206-1

CLEAN UTILITY

231-1

TOILET

238-1

RECEPTION

241-1

NURSE STATION

224-1

EXIST. STAIRS

2-STAIR-W

TOILET

210-1

TOILET

203-1

TOILET

205-1

CORR

200-1

CORR

201-1

CORR

225-1

CORR

212-1

CORR

219-1

CORR

207-1

STAFF TOILET

222-1

HSKPG

240-1

CHASE

ELECT.

228-1

NOURISH.

227-1

ALCOVE

201A-1

CLEAN LINEN

201B-1

TOILET

235-1

TOILET

237-1

CLOSET

207A-1

1. FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE

FOR THE SPRINKLER HEAD LAYOUTS, CALCULATIONS,

AND ENGINEERING DRAWINGS AS LISTED IN GENERAL

NOTES ON F-001.

2. THIS CONTRACTOR IS RESPONSIBLE FOR SUBMITTING

FULL COORDINATION AND LAYOUT DRAWINGS PER FIRE

PROTECTION SPEC SECTION. COORDINATION SHOULD BE

COMPLETED WITH ALL TRADES INCLUDED.

CONSTRUCTION SHALL NOT BEGIN UNTIL COORDINATION

DRAWINGS HAVE BEEN REVIEWED BY THE ENGINEER

AND COR.

GENERAL NOTES

LIGHT HAZARD

PLAN NOTES

ORDINARY HAZARD I

ORDINARY HAZARD II

NO

HATCH

PHASE 1

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

F-121

FIRE PROTECTION - SECOND FLOOR

BOH AR04/26/2018

1/4" = 1'-0"

FIRE PROTECTION PLAN - SECOND FLOOR

2' 4' 8'0'

1/4" = 1'-0"

N

No. Description Date

1-E

1-51-31-21-1

1-H

1-J1A-A

1-M

1-N

1-Q1A-D

1A-C

1A-B

1-T

1-V

1-W

1-U

1-3A

1-6

1-9

1-11

1-13

1-X

1-R

1-I

1-D

1-20 1-211-16

1-121-101-7

1-G

AREA NOT IN SCOPE

REMOVE AND RELOCATE FIRE

SPRINKLER HEADS TO PROVIDE

PROPER COVERAGE WITHIN THE

OUTLINED AREA.

PATIENT ROOM

336-1

EQUIP. STOR.

338-1

EQUIP. ALCOVE

300-1

HALL

301-1

HALL

326-1

HALL

339-1

EXIST. STAIRS

3-STAIR-W

ELECT.

328-1

CLEAN UTILITY

330-1

TOILET

337-1

PATIENT ROOM

334-1

TOILET

335-1

SOILED UTILITY

319-1

PATIENT RM

316-1

TOILET

317-1

STORAGE

320-1 TOILET

321-1

ANTE RM

318-1

PATIENT RM

322-1

PATIENT RM

314-1

HSKPG

324-1

NURSE STATION

325-1

STAFF TOILET

323-1

TOILET

313-1CHASE

NOURISH.

327-1

PATIENT RM

311-1

TOILET

310-1

TOILET

309-1

PATIENT RM

308-1

BARIATRIC PATIENT ROOM

302-1

PATIENT RM

304-1

TOILET

305-1

HALL

307-1

HALL

312-1

CHARTING

306-1

ALCOVE

301-1A

CLOSET

307A-1

MEDICATION

331-1

EQUIP. STOR.

329-1

1. FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE

FOR THE SPRINKLER HEAD LAYOUTS, CALCULATIONS,

AND ENGINEERING DRAWINGS AS LISTED IN GENERAL

NOTES ON F-001.

2. THIS CONTRACTOR IS RESPONSIBLE FOR SUBMITTING

FULL COORDINATION AND LAYOUT DRAWINGS PER FIRE

PROTECTION SPEC SECTION. COORDINATION SHOULD BE

COMPLETED WITH ALL TRADES INCLUDED.

CONSTRUCTION SHALL NOT BEGIN UNTIL COORDINATION

DRAWINGS HAVE BEEN REVIEWED BY THE ENGINEER

AND COR.

GENERAL NOTES

LIGHT HAZARD

PLAN NOTES

ORDINARY HAZARD I

ORDINARY HAZARD II

NO

HATCH

PHASE 1

Drawing Title Project Title

Date

Location

Checked

Project Number

Drawing Number

Drawn

Dwg. ofRevisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

589A7-17-203

Robert J. Dole VA Medical Center

RENOVATE WARDS FOR PATIENT

PRIVACY PHASE 1, B1

117 PIERCE ST, SUITE 110

SIOUX CITY, IOWA

142 N. MOSELY ST

WICHITA, KANSAS

F-131

FIRE PROTECTION - THIRD FLOOR

BOH AR04/26/2018

1/4" = 1'-0"

FIRE PROTECTION PLAN - THIRD FLOOR