36C25518R0283-004.pdf

PDF 5 MB Posted

Attached to
Renovate Vacated Ward 6 Surgery Project #589A4-16-102
Solicitation number
36C25518R0283
Issued by

About this file

36C25518R0283 Drawings-Renovate Vacate 6 SURGERY Vol 1 - 21 Pages.pdf

View the file

Other files

File Type Posted
36C25518C0177-000.docx DOCX document
36C25518R0283-00003001.pdf PDF
36C25518R0283-00003000.docx DOCX document
36C25518R0283-00002000.docx DOCX document
36C25518R0283-00002001.txt TXT text file
36C25518R0283-00002002.pdf PDF
36C25518R0283-00001000.docx DOCX document
36C25518R0283-006.pdf PDF
36C25518R0283-002.pdf PDF
36C25518R0283-005.pdf PDF
36C25518R0283-003.pdf PDF
36C25518R0283-001.docx DOCX document
36C25518R0283-000.docx DOCX document
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building 1

Hospital Drive

M o n k D ri v e

Stadium Boulevard (HWY 740)

T ig e r

A v e n u e

Project Area Building 1 6th Floor

N

Campus Site Map

NTS

Office of Facilities

Management

Project Number

Building Number

Drawing Number

DrawnCheckedDate

Location

Project TitleDrawing Title

ARCHITECT/ENGINEERS:

VA Project #

CONSULTANTS:

Revisions: Date:

VA FORM 08-6231 OCT 1978

on e ei gh th in ch o ne fo ot qu ar te r th re ig ht s on e h al f i nc h f oo t th re qu ar te rs

6" on e i nc h f oo t

6" a nd h al f

6" th re e i nc he s f oo t

6" 6"

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

VeteransA sffair Depa frtmento

One Memorial Drive Suite 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

18207 Edison Avenue Chesterfield, MO 63005

Tel Fax

636.530.7770 636.530.7877

Department of Veteran's Affairs Medical Center

Owner

Harry S Truman VA Medical Center

Columbia, MO

Contact: Jason Bavlnka

Phone: 573.814.6169

800 Hospital Drive

Email: jason.bavlnka@va.gov

Architect

Fox Architects

St. Louis, MO 63102

Bob Dunn p: 314.621.4343x115

1 Memorial Drive Suite 1800

Email: bdunn@fox-arch.com

Mechanical Engineer

SSC Engineering, Inc.

Chesterfield, MO 63005

Chris Cornett p: 636.530.7770

18207 Edison Avenue

Email: ccornett@sscengineering.com

Plumbing & Fire Protection Engineer

SSC Engineering, Inc.

Chesterfield, MO 63005

Chris Cornett PE, LEED, AP p: 636.530.7770

18207 Edison Avenue

Email: ccornett@sscengineering.com

Electrical Engineer

SSC Engineering, Inc.

Chesterfield, MO 63005

Mark Jones, PE p: 636.530.7770

18207 Edison Avenue

Email: mjones@sscengineering.com

Structural Engineer

SSC Engineering, Inc.

Chesterfield, MO 63005

Michael Vande Velde p: 636.530.7770

18207 Edison Avenue

Email: mvandevelde@sscengineering.com

2/7/2018 4:32:31 PM

Renovate Vacated Surgery, Ward 6

800 Hospital Drive Columbia, MO 65201

Harry S Truman Memorial Veterans' Hospital

589A4-16-102

589A4-16-102

01/19/2018 BD/HT ZF

2-G0.0 800 Hospital Drive Columbia, MO 65201

Cover

BID DOCUMENTS

Renovate Vacated Surgery, Ward 6

INDEX OF DRAWINGS

2-G0.0 Cover

2-G0.1 General Information

2-G0.2 Overall Existing 6th Floor Plan

2-G1.0 6th Floor Life Safety Plan

2-A1.0 6th Floor Demolition Plan

2-A1.1 6th Floor Renovation Plan

2-A1.2 6th Floor Renovation Plan - North

2-A1.3 6th Floor Renovation Plan - South

2-A1.4 Penthouse Plans

2-A1.5 Exterior Elevations & Details

2-A2.0 5th Floor Ceiling Work

2-A2.1 6th Floor Reflected Ceiling Plan - North

2-A2.2 6th Floor Reflected Ceiling Plan - South

2-A3.0 Enlarged Restroom Plans & Elevations

2-A3.1 Interior Elevations & Details

2-A4.0 Partition Types, Door Schedule & Details

2-A5.0 6th Floor Finish Plan & Schedules

2-M0.1 Mechanical Notes, Symbols, Abbreviations and Schedules 2-M0.2 Mechanical Schedules and Flow Control Diagrams 2-M0.3 Mechanical Details 2-M1.1 Mechanical 6th Floor Ductwork Plans 2-M1.2 Mechanical 6th Floor Piping Plans 2-M2.1 Mechanical Roof and Penthouse Ductwork Plans

2-E0.1 Electrical Notes, Symbols, Abbreviations and Schedules 2-E0.2 Electrical Panel Schedules 2-ED1.1 Electrical 6th Floor Existing Conditions Plans - For Reference Only 2-E1.1 Electrical 6th Floor Lighting Plans 2-E2.1 Electrical 6th Floor Power and Systems Plans

2-PL0.1 Plumbing Notes, Symbols, Abbreviations, and Schedules 2-PLD1.1 Plumbing 5th and 6th Floor Waste and Vent Plans - Demolition 2-PLD2.1 Plumbing 5th and 6th Floor Domestic Water Plans - Demolition 2-PPD1.1 Plumbing 6th Floor Medical Gas Plan - Demolition 2-PL1.1 Plumbing 5th and 6th Floor Waste and Vent Plans - Renovation 2-PL2.1 Plumbing 5th and 6th Floor Domestic Water Plans - Renovation 2-PL3.0 Plumbing Isometrics Waste and Vent 2-PL3.1 Plumbing Isometrics Waste and Vent 2-PL3.2 Plumbing Isometric Domestic Water

2-FP0.1 Fire Protection Notes, Symbols, Abbreviations and Schedules 2-FP1.1 Fire Protection 6th Floor Plans

General

Architectural

Mechanical

Plumbing

Electrical

Fire Protection

DAVID ISAACKS, FACHE

Director

PAUL F. HOPKINS

Assistant Director

LANA ZERRER, M.D.

Chief of Staff

CHERYLE KELLY, RN, MSN

Associate Director for Patient Services

CLAY T. ATHERTON Sr.

Chief, Facilities Management

ROBERT G. RITTER, FACHE

Associate Director

Signature Date Signature Date Signature Date

Signature DateSignature DateSignature Date

SIGN-OFF LIST

Structural

2-S0.1 Structural General Notes 2-S2.1 Structural Framing Plans and Details

SHANNON MILLER

Safety Officer

SUSAN SCOTT

Infectious Control

Signature DateSignature Date

1/19/2018

TOWELS

REQUIRED PREFERRED

CUPS

SWITCH

OUTLETS

VENDING

TOWELS

REQUIRED PREFERRED

CUPS

SWITCH

FORWARD REACH

SIDE REACH

M

IN

M A

X

M A

X

M

IN

VENDING

NOTE:

PROJECT-STANDARD PLACEMENT

SWITCH, THERMOSTAT, HORN/STROBE

FLOOR

CEILING

F.A. HORN/STROBE (WHEN

OCCURS)

EDGE OF DOOR FRAME

CL

LIGHT SWITCH

THERMOSTAT

CL

CL

8" MIN. - 12" MAX

3'

CL

CL

POWER/COMM RECEPTACLE

1'

KNEE BRACE

LAVATORY

LINEAR FEET

LINTEL

MASONRY

MATERIAL

MAXIMUM

MEDIUM DENSITY FIBERBOARD

MECHANICAL

MANUFACTURER

MANHOLE

MINIMUM

MIRROR

MISCELLANEOUS

MASONRY OPENING

MOUNTED

METAL

NOT IN CONTRACT

NOMINAL

NOT TO SCALE

ON CENTER

OUTSIDE FACE

OPENING

OPPOSITE

PAINT

PARTICLE BOARD

PLASTIC LAMINATE

PLUMBING

PLASTIC

PAIR

PREFINISHED

PROPERTY

PRESSURE TREATED

PAINTED

PARTITION

PLYWOOD

RISER OR RADIUS

RUBBER BASE

ROOF DRAIN

REFERENCE

REINFORCED

REQUIRED

REVISION

RAILING

ROOM

ROUGH OPENING

SOLID CORE

SCHEDULE

SECTION

SHEATHING

SIMILAR

SINK

SHEET METAL

SOFFIT

SPECIFICATIONS

SQUARE

SOLID SURFACING MATERIAL

STAINLESS STEEL

STANDARD

STEEL

STRUCTURE

SUSPENDED

SLAT WALL

SYSTEM

TREAD

TOP OF CONCRETE

TELEPHONE

TEMPERED GLASS LITE

TOP OF JOIST

TOP OF STEEL

TOP OF WALL

TYPICAL

UNFINISHED

UNLESS OTHERWISE NOTED

URINAL

VINYL BASE

VINYL COMPOSITION TILE

VERTICAL

VERIFY IN FIELD

WIDTH

WITH

WATER CLOSET

WOOD

WINDOW

WIDE FLANGE

WITHOUT

WATERPROOFING

YARD

KB

LAV

LF

LNTL

MAS

MAT

MAX

MDF

MECH

MFR

MH

MIN

MIR

MISC

MO

MTD

MTL

NIC

NOM

NTS

OC

OF

OPNG

OPP

P

PBD

PLAM, PL

PLBG

PLS

PR

PREF

PROP

PT

PTD

PTN

PWD

R

RB

RD

REF

REINF

REQD

REV

RLG

RM

RO

SC

SCH

SECT

SHTH

SIM

SK

SM

SOF

SPEC

SQ

SSM

SST

STD

STL

STR

SUSP

SW

SYS

T

TC

TEL

TGL

TJ

TS

TW

TYP

UF

UON

UR

VB

VCT

VERT

VIF

W W/

WCL

WD

WDW

WF

WO

WPG

YD

ACT

ADJ

ADJC

AFF

ALT

ALUM

ARCH

AVG

BD

BL

BLDG

BLKG

BOD

BR

BTWN

C

CAB

CB

CC

CG

CJ

CL

CLG

CMU

COL

CONC

CONST

CONT

CP

CRT

CS

CSJ

CST

CT

DEMO

DIA

DIM

DN

DR

DS

DTL

DWG

EA

EJ

ELECT

ELEV

EP

EQ

EQUIP

EWC

EXT

EXTG

FAB

FCU

FD

FDN

FEC

FF

FG

FHC

FIN

FLR

FLG

FLT

FPG

FR

FRP

FSK

FT

FTG

FTWD

FWP

G

GA

GL

GR

GT

GWB

HC

HD

HDBD

HDW

HDWD

HM

HOR

HR

HT

HWH

IF

INSUL

JT

REFER TO THE MATERIAL LEGEND FOR ABBREVIATIONS RELATED TO FINISHES NOT HERE LISTED

ABBREVIATIONS LIST

ACOUSTIC CEILING TILE

ADJUSTABLE

ADJACENT

ABOVE FINISHED FLOOR

ALTERNATE

ALUMINUM

ARCHITECTURAL

AVERAGE

BOARD

BLINDS

BUILDING

BLOCKING

BOTTOM OF DECK

BRICK

BETWEEN

CARPET

CABINET

CATCH BASIN

CONCRETE, COLORED

CORNER GUARD

CONTROL JOINT

CENTERLINE

CEILING

CONCRETE MASONRY UNIT

COLUMN

CONCRETE

CONSTRUCTION

CONTINUOUS

COMMUNICATIONS PANEL

CATHODE RAY TUBE

CONSTRUCTION JOINT

CONCRETE, SEALED

CONCRETE, STAINED

CERAMIC TILE

DEMOLITION

DIAMETER

DIMENSION

DOWN

DOOR

DOWNSPOUT

DETAIL

DRAWING

EACH

EXPANSION JOINT

ELECTRICAL

ELEVATION

ELECTRICAL PANEL

EQUAL

EQUIPMENT

ELECTRIC WATER COOLER

EXTERIOR

EXISTING

FABRICATED

FAN COIL UNIT

FLOOR DRAIN

FOUNDATION

FIRE EXTINGUISHER CABINET

FINISH FLOOR

FINISH GRADE

FIRE HOSE CABINET

FINISH

FLOOR

FLASHING

FLOOR TILE

FIREPROOFING

FIRE RATING

FIBERGLASS REINFORCED PANEL

FLOOR SINK

FEET

FOOTING

FIRE TREATED WOOD

FABRIC WRAPPED PANEL

GRANITE

GAUGE

GLASS

GRADE

GROUT

GYPSUM WALLBOARD

HOLLOW CORE

HEAD

HARDBOARD

HARDWARE

HARDWOOD

HOLLOW METAL

HORIZONTAL

HANDRAIL

HEIGHT

HOT WATER HEATER

INSIDE FACE

INSULATION

JOINT

X

XX

LEGEND - SYMBOLSLEGEND - SYMBOLS

STEEL

CONCRETE

ALUMINUM

BRICK

WOOD (FINISHED)

COMPACTED GRAN. FILL

BATT INSULATION

GYPSUM WALL BOARD

(SMALL SCALE)

CONTINUOUS

WOOD BLOCKING

HATCH INDICATIONS SHOWN AS GUIDE ONLY; HATCHING SCALES MAY NEED TO BE MODIFIED DEPENDING UPON SCALE USED

MATERIALS INDICATION

NON-CONTINUOUS

WOOD BLOCKING

EARTH

GYPSUM WALL BOARD

(LARGE SCALE)

PLYWOOD

RIGID INSULATION

SAND

PRECAST

ASPHALT

XX

XX

XXX

XX

XXX

XX

XX

T.O.

X'-X" A.F.F.

T.O.

X'-X" A.F.F.

X

YY.Y

X

X

X

XYY.Y

X

YY.Y

X

YY.Y

X

X

X

XYY.Y

X

YY.Y

XX

CONTROL POINT

KEYED NOTE

CENTER LINE MARK

REVISION NUMBER

ELEVATION DATUM

EXISTING COLUMN LINE

NEW COLUMN LINE

EXTERIOR ELEVATION MARK

X = ELEVATION NUMBER

Y = SHEET NUMBER

WINDOW NUMBER

PARTITION TYPE DETAIL MARK

X = DETAIL NUMBER

Y = SHEET NUMBER

NORTH ARROW

SECTION MARK

X = SECTION NUMBER

Y = SHEET NUMBER

EXISTING

PARTITION INTERIOR ELEVATION MARK

X = ELEVATION NUMBER

Y = SHEET NUMBER

CONTROL POINT

KEYED NOTE

CENTER LINE MARK

REVISION NUMBER

ELEVATION DATUM

EXISTING COLUMN LINE

NEW COLUMN LINE

EXTERIOR ELEVATION MARK

X = ELEVATION NUMBER

Y = SHEET NUMBER

NEW

PARTITION

NEW DOOR

W/ DOOR

NUMBER

ROOM NAME &

NUMBER

WINDOW NUMBER

PARTITION TYPE

DEMOLISHED

DOOR

EXISTING

DOOR

DETAIL MARK

X = DETAIL NUMBER

Y = SHEET NUMBER

NORTH ARROW

SECTION MARK

X = SECTION NUMBER

Y = SHEET NUMBER

DEMOLISHED

PARTITION

INTERIOR ELEVATION MARK

X = ELEVATION NUMBER

Y = SHEET NUMBER

XXEQUIPMENT TAG FLOOR MATERIAL

TRANSITION

X

YY.Y

xxxxxx

F.E. MANUF.

COORDINATE W/

F I R E

E X T I N G U I S H E R

SEMI RECESSED FIRE

EXTINGUISHER CABINET

BY LARSON OR SIM. - RE:

FLOOR PLAN FOR

LOCATIONS

/2

M A

X

X

(2) METAL STUDS ON

EACH SIDE OF CABINET

3/4" PLYWOOD

SHEATHING EA. SIDE OF

CABINET - TYP.

DASHED LINE INDICATES

GYPSUM BOARD WHERE

OCCURS - RE: FLOOR PLAN

AND PARTITION TYPES FOR

ADDITIONAL INFO.

METAL STUD PARTITION

- RE: FLOOR PLAN AND

PARTITION TYPES FOR

ADDITION INFO.

GWB - PAINTED

SOUND INSULATION

WHERE OCCURS -

RE: FLOOR PLAN

AND PARTITION

TYPE FOR LOCATION

PLANELEVATION

SEMI RECESSED FIRE

EXTINGUISHER CABINET BY

LARSON OR SIM. - RE:

FLOOR PLAN FOR

LOCATIONS

CLEAR ACRYLIC DOOR

GLAZING - TYP

DIE CUT LETTERING - TYP

DOOR HARDWARE BY

CABINET MANUF.

A

F F

NOTE:

FIRE EXTINGUISHER

CABINET TO MEET ALL

ADA REQUIREMENTS.

CONTRACTOR TO REFER

TO LIFE SAFETY PLANS

FOR LOCATION OF

CABINETS. REFER TO

SPECIFICATION FOR

ADDITIONAL INFO.

P-TYPE;

RE: PLAN

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

VeteransA sffair Depa frtmento

One Memorial Drive Suite 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

2/7/2018 4:32:33 PM

General Information

2-G0.1 800 Hospital Drive Columbia, MO 65201

01/19/2018

BID DOCUMENTS

BD/HT ZF

589A4-16-102Renovate Vacated Surgery, Ward 6

GENERAL NOTES

PHASE ALL DEMOLITION & CONSTRUCTION TO BE SEQUENCED & COORDINATED TO INSURE THAT

THE BUILDING OWNER'S OPERATIONS ARE CONTINUOUSLY MAINTAINED.

2. THESE PLANS REFLECT INFORMATION GATHERED FROM EXISTING CONDITIONS DRAWINGS &

ARCHITECT'S FIELD VERIFICATION. CONTRACTOR SHALL VERIFY ACCURACY OF INFORMATION

PRIOR TO COMMENCEMENT OF ANY DEMOLITION AND /OR CONSTRUCTION ACTIVITIES AND

REPORT ANY DISCREPANCIES TO COR.

3. ITEMS TO BE DEMOLISHED, REMOVED, OR RELOCATED ARE SHOWN DASHED. EXISTING ITEMS

TO REMAIN SHALL BE PROTECTED DURING CONSTRUCTION BY CONTRACTOR. PATCH & REPAIR

ALL RESULTING SURFACES TO REMAIN.

4.

1.

COORDINATE ALL WORK BETWEEN TRADES AS REQUIRED TO INSURE TIMELY & PROPER

INSTALLATION OF ALL BUILDING SYSTEMS.

5.

6.

ACCESS TO EMPLOYEE ENTRY AND EXIT DOORS MUST BE MAINTAINED THROUGHOUT

CONSTRUCTION. PROVIDE ALL VA REQUIRED BARRIERS AND SIGNAGE AT THE LIMITS OF THE

CONSTRUCTION SITE.

7.

PROVIDE FULLY SEALED DUST PARTITIONS AS REQUIRED AT ALL LOCATIONS WHERE

CONSTRUCTION MEETS THE EXISTING BUILDING IN ORDER TO MAINTAIN A CLEAN DUST-FREE

ENVIRONMENT INSIDE THE BUILDING.

8.

ALL GYPSUM BOARD USED IN THIS PROJECT SHALL BE TYPE "X"

CONTRACTORS SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE EXISTING

CONDITIONS AND INCLUDE THE WORK NECESSARY TO COMPLY WITH THE SCOPE OF THE WORK.

ADDITIONAL COMPENSATION WILL NOT BE CONSIDERED FOR EXTRA WORK WHEN SUCH WORK

COULD HAVE BEEN REASONABLY ASCERTAINED FROM THE PRE BID SITE VISIT REVIEW OF THE

EXISTING CONDITIONS AND THE WORK SCOPE DESCRIBED IN THE DOCUMENTS.

10.

COORDINATION OF ALL WORK AS DESCRIBED ON THE DOCUMENTS IS THE GENERAL

CONTRACTOR'S RESPONSIBILITY.

11.

PERFORM WORK IN ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND

ORDINANCES HAVING JURISDICTION.

12.

IMMEDIATELY REPORT DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND FIELD

CONDITIONS, CONFIRM THE WORK IS BUILDABLE AS SHOWN.

ALL DIMENSIONS ARE FROM COLUMN CENTER LINE TO FACE OF PARTITION U.O.N. UNDER NO

CIRCUMSTANCES SHALL ANY MEASUREMENT BE SCALED FROM THE DRAWINGS. ANY

MEASUREMENT NOT GIVEN AN ACTUAL NUMBER DIMENSION SHOULD BE BROUGHT TO THE

ATTENTION OF THE COR/ARCHITECT BEFORE PROCEEDING.

13. ALL WOOD USED IN THIS PROJECT SHALL BE FIRE-RETARDANT TREATED

14. ALL NEW PARTITIONS, UNLESS OTHERWISE SHOWN, SHALL BE 20 GA. MTL STUDS

15. COORDINATE & PROVIDE BLOCKING AS REQUIRED FOR MILLWORK & ITEMS ATTACHED OR

MOUNTED TO WALLS & CEILINGS

16. ALL INSULATING MATERIALS WITHIN WALLS & IN UNCONCEALED SPACES SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450

17. ALL MATERIALS EXPOSED WITHIN PLENUMS ARE REQUIRED TO BE NON-COMBUSTIBLE OR SHALL

HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT

MORE THAN 50 AS DETERMINED IN ACCORDANCE WITH ASTM E-84

18. PROJECT LIMIT LINES INDICATE THE AREA OF A MAJORITY OF THE PROJECT WORK. BUT SOME

WORK WILL BE REQUIRED OUTSIDE OF THE PROJECT LIMITS. REFER TO DRAWINGS AND

SPECIFICATIONS FOR INFORMATION.

THE CONTRACTING OFFICER’S REPRESENTATIVE (COR) WILL PERFORM FIELD VERIFICATION AS

REQUIRED FOR THE DURATION OF THE PROJECT TO MONITOR PROJECT PROGRESS.

UTILITY SHUT DOWNS WILL BE COORDINATED BY IPT (INTEGRATED PROJECT TEAM) INCLUDING: COR, VA FACILITY OPERATIONS, AND GENERAL CONTRACTOR.

ANY INTEGRATED PROJECT TEAM MEMBER (IPT), INCLUDING BUT NOT LIMITED TO: CONTRACTORS / SUB-CONTRACTORS, ARCHITECTS AND/OR ENGINEERS WHO ENTER THE PROJECT BOUNDARY SHALL WEAR ALL PROPER PERSONAL PROTECTIVE EQUIPMENT (PPE’S: CERTIFIED BY OSHA) AT ALL TIMES.

SUCH PPE’S INCLUDE: HARD HATS, SAFETY GLASSES, ETC.

IF THE PROJECT AREA AND AREAS AFFECTED BY THE PROJECT INCLUDE EXISTING EQUIPMENT, SURFACES, FINISHES, MATERIALS, ETC., NOT TO BE REMOVED, THE CONTRACTOR MUST PROTECT THIS EQUIPMENT FROM DUST, DEBRIS, DAMAGE, ETC. THE CONTRACTOR MUST ALSO CLEAN THESE ITEMS/SURFACES TO THE ORIGINAL CONDITION FOUND AT THE START OF THE PROJECT PRIOR TO FINAL INSPECTION. CONTRACTOR IS RESPONSIBLE TO REPAIR/REPLACE ANY DAMAGED EQUIPMENT, ITEMS, ETC.

PATCH ALL FINISHES WHERE DISTURBED BY THE WORK AND WHERE UNFINISHED SURFACES HAVE

BEEN EXPOSED BY DEMOLITION. PATCHING MUST MATCH ADJACENT MATERIALS, COLORS, AND

FINISHES. WALL SURFACES THAT ARE PATCHED SHALL HAVE THE FINISHES (PAINT, VINYL WALL

COVERING, ETC.) REPLACED FROM CORNER TO CORNER AND FLOOR TO CEILING.

UNLESS OTHERWISE INDICATED, FINISH ALL NEW FRAMES AND PARTITIONS TO MATCH

SURROUNDING. NEW HOLLOW METAL DOORS SHALL BE PAINTED SAME COLOR AS FRAMES. EXISTING PARTITIONS RECEIVING NEW DOOR FRAMES THAT HAVE VINYL WALL COVERING (VWC) SHALL HAVE

THE VWC COMPLETELY REMOVED AND REPLACED WITH NEW VWC OF MATCHING TEXTURE AND

COLOR.

CORRIDOR WALLS AND PLUMBING PARTITIONS SHALL BE CONSIDERED 1 HOUR FIRE / SMOKE RATED WALLS AND NEW OR EXISTING PENETRATIONS MUST BE SEALED ACCORDINGLY WITH UL APPROVED FIRE STOPPING MATERIAL THE SAME DAY THE PENETRATION IS MADE OR DISCOVERED. ALL FLOOR SLABS, VERTICAL SHAFTS AND STAIRWELLS SHALL BE CONSIDERED 2 HOUR FIRE / SMOKE RATED SEPARATIONS AND SHALL BE SEALED ACCORDINGLY IN THE MANNER LISTED HEREIN. PENETRATIONS

THROUGH THE EXTERIOR WALLS SHALL BE SEALED WATERTIGHT.

IF EXISTING WALLS ARE TO BE USED AS DUST OR SMOKE BARRIERS SEPARATING THE CONSTRUCTION AREA FROM THE MEDICAL CENTER, THE CONTRACTOR IS RESPONSIBLE FOR SEALING ALL EXISTING PENETRATIONS IN THIS WALL, EXTENDING WALL TO CEILING SLAB AND ANY OTHER WORK TO ENSURE

THE WALL MEETS THE REQUIREMENTS IN THE GENERAL REQUIREMENTS SPECIFICATIONS FOR

CONSTRUCTION BARRIERS.

WHENEVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE REMOVED, SUCH

REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, FOUNDATIONS, ETC., UNLESS NOTED

OTHERWISE. AFTER REMOVAL; FLOORS, WALLS, AND CEILINGS SHALL BE FINISHED TO MATCH

ADJOINING SURFACES.

UTILITY WORK THAT WILL REQUIRE A SHUTDOWN OF EXISTING SERVICE WILL BE DONE AT TIMES

OTHER THAN NORMAL WORKING HOURS AT NO ADDITIONAL COST TO THE GOVERNMENT. WORK

MUST BE SCHEDULED WITH THE COR 72 HOURS IN ADVANCE OF SHUTDOWN.

ALL NEW VERTICAL AND HORIZONTAL DUCTS, PIPES, CONDUITS, ETC., IN FINISHED ROOMS OR AREAS

THROUGHOUT BUILDING, NOT ENCASED IN MASONRY OR CONCRETE CONSTRUCTION, SHALL BE

ENCLOSED IN METAL STUDS AND DRYWALL CHASE WALLS AS DETAILED IN THE DRAWINGS AND

FINISHED TO MATCH THE ROOM FINISH.

WORK THAT MUST OCCUR IN OCCUPIED AREAS OF THE MEDICAL CENTER OR DISRUPT A MEDICAL

CENTER FUNCTION, WILL BE DONE AT TIMES OTHER THAN NORMAL WORKING HOURS AT NO

ADDITIONAL COST TO THE GOVERNMENT. WORK MUST BE SCHEDULED WITH THE VA COR 72 HOURS

IN ADVANCE OF WORK TO TAKE PLACE

CONTRACTOR SHALL NOT INSTALL CONDUIT, PIPING, LIGHTING, OR OTHER OBSTRUCTIONS UNDER

ADJACENT HVAC EQUIPMENT THAT WILL ELIMINATE OR OBSTRUCT ACCESS TO COILS, MOTORS,

VALVES, SWITCHES, PANELS, ETC.

BEFORE THE CONTRACTOR BEGINS WORK, CONTRACTOR SHALL RECORD ANY EXISTING SYSTEM

INFORMATION SUCH AS TEMPERATURE, FLOW RATE, PRESSURE, CURRENT, VOLTAGE, OR ANY

OTHER INFORMATION NECESSARY FOR HIM TO RETURN THE AFFECTED SYSTEM TO ORIGINAL

OPERATING CONDITION. UNLESS NOTED OTHERWISE IT IS ASSUMED THAT ALL SYSTEMS (HVAC, ELECTRICAL, PLUMBING, ETC.) ARE WORKING PROPERLY IN EVERY MANNER AT THE BEGINNING OF

THE PROJECT. THE CONTRACTOR'S RECORDED MEASUREMENTS MUST BE SUBMITTED TO THE

COR FOR REVIEW AND ACCEPTANCE BEFORE ANY DEMOLITION OR OTHER RELATED WORK CAN

PROCEED.

THE CONTRACTOR WILL BE RESPONSIBLE FOR MAINTAINING ALL EXISTING ACCESS DOORS TO

CONSTRUCTION AREAS, EXISTING MECHANICAL AND ELECTRICAL AREAS, ASSIGNED STORAGE

AREAS, EQUIPMENT ACCESS AREAS, ETC. DOORS MUST BE RESTORED TO THE CONDITION

ENCOUNTERED AT BEGINNING OF PROJECT. THIS INCLUDES DOOR REPLACEMENT, HARDWARE

REPLACEMENT, HARDWARE REPAIR, DOOR REPAIR, ETC.

CONTRACTOR MUST PROVIDE HIS OWN EQUIPMENT FOR MOVING OF MATERIALS, EQUIPMENT AND

TRASH. THIS INCLUDES CARTS FOR REMOVAL OF DEMOLITION MATERIALS, PALLET JACKS FOR

EQUIPMENT MOVING, TWO OR FOUR WHEEL CARTS FOR EQUIPMENT TRANSFER, ETC.

CONTRACTOR MAY NOT BORROW VA OWNED EQUIPMENT FOR THIS PURPOSE.

SEVERE NOISE PRODUCING WORK WILL NOT BE ALLOWED DURING NORMAL WORKING HOURS AND

MUST BE SCHEDULED WITH THE COR FOR OTHER TIMES 72 HOURS IN ADVANCE OF WORK TAKING

PLACE. THIS INCLUDES JACK-HAMMERING CONCRETE, SAW-CUTTING CONCRETE, REPETITIVE

HAMMER DRILLING OF CONCRETE, ETC.

THE VA DOES NOT PROVIDE PHONES FOR THE CONTRACTOR’S USE. IT IS THE CONTRACTOR’S

RESPONSIBILITY TO COVER THE COSTS OF A CELLUALR PHONE TO BE HELD BY THE

SUPERINTENDENT THROUGOUT THE PROJECT. PROVIDE DIRECT PHONE NUMBER TO COR BEFORE

THE START OF THE PROJECT.

ALL ELECTRICAL CIRCUITRY TO BE CONCEALED UNLESS OTHERWISE SPECIFIED. CIRCUITING FOR

ELECTRIC DOOR HOLD OPENS IN MASONRY WALLS SHALL BE SURFACE RACEWAY.

DRAWINGS ARE DIAGRAMMATIC AND SHOW ONLY THE GENERAL ARRANGEMENT OF EACH SYSTEM.

BECAUSE OF SMALL SCALE OF DRAWINGS IT IS NOT POSSIBLE TO SHOW OR INDICATE ALL

BRANCHES, OFFSETS, FITTINGS, BOXES, AND ACCESSORIES WHICH MAY BE REQUIRED.

CONTRACTOR MUST CAREFULLY INVESTIGATE STRUCTURAL AND FINISH CONDITIONS AFFECTING

ALL WORK, FURNISHING SUCH FITTINGS, TRAPS, VALVES, BOXES, ACCESSORIES, ETC., AS MAY BE

REQUIRED.

LOCATIONS OF NEW EQUIPMENT, PIPING, AND ASSOCIATED ITEMS SHOWN ON THE DRAWINGS ARE SCHEMATIC ONLY. THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION AND ELEVATION FOR ALL WORK, INCLUDING CONNECTIONS TO EXISTING WORK. ALL OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR A COMPLETE AND FUNCTIONAL SYSTEM SHALL BE PROVIDED

AT NO ADDITIONAL COST.

ALL EXISTING DUCTWORK, ELECTRICAL OR MECHANICAL PIPING, CABLE TRAYS, ETC., ARE NOT

NECESSARILY SHOWN ON THE DRAWINGS. PRIOR TO ANY DEMOLITION AND CONSTRUCTION

WORK, THE CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING

EQUIPMENT, DUCTWORK, PIPING, ETC. AND REPORT ANY DISCREPANCIES TO THE COR.

IF THERE IS ANY WORK TO BE DONE ON EXISTING ROOFS, SUCH AS ROOF PENETRATIONS OR

STANDS, OR ANYTHING THAT DAMAGES THE INTEGRITY OF THE ROOF, THIS WORK MUST BE DONE

BY A CONTRACTOR LICENSED BY THE ROOFING MEMBRANE MANUFACTURER. HE/SHE MUST BE

APPROVED BY THE MEMBRANE MANUFACTURER SO AS TO NOT VOID OR INTERRUPT EXISTING

SINGLE PLY MEMBRANE ROOF WARRANTIES.

IF ASBESTOS INSULATION IS REMOVED ON THIS PROJECT ALL PIPING AND OTHER MECHANICAL ITEMS THAT HAD THE ASBESTOS INSULATION REMOVED MUST BE RE-INSULATED WITH MATERIALS

ACCORDING TO THE SPECIFICATIONS.

WHEN WORKING IN OCCUPIED AREAS OF THE MEDICAL CENTER THE CONTRACTOR CANNOT LEAVE

TOOLS, EQUIPMENT, LADDERS, ETC., UNATTENDED WHERE THEY ARE ACCESSIBLE TO PATIENTS, STAFF, VISITORS, ETC. CEILING TILES AND CEILING ACCESS PANELS MUST ALSO BE REPLACED

WHEN UNATTENDED, FOR SAFETY REASONS.

WATER OR LIQUIDS MUST NOT BE ALLOWED TO COME INTO CONTACT WITH NEW OR EXISTING

DRYWALL FROM CONSTRUCTION RELATED ACTIVITIES. REMOVE AND REPLACE ANY DRYWALL

THAT HAS COME INTO CONTACT WITH WATER OR OTHER LIQUIDS.

LIVE ELECTRICAL CIRCUITS ARE BURIED WITHIN THE CONCRETE FLOOR SLABS AND THERE IS NO

RECORD OF THE EXACT LOCATIONS. THE CONTRACTOR SHALL X-RAY THE FLOOR WHEREVER THE

CONTRACTOR PLANS ON DRILLING THROUGH THE CONCRETE FLOOR SLABS. IT WILL BE THE

CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY REPAIR ANY CIRCUIT THAT HAS BEEN CUT OR

DAMAGED.

WHEN AN EXIT IS CLOSED BECAUSE OF THIS PROJECT THE CONTRACTOR MUST INSTALL

BARRICADES AND SIGNAGE AT THE EXIT DOOR. THE CONTRACTOR MUST ALSO COVER OR

REMOVE THE LIGHTED EXIT SIGN.

CONTRACTOR SHALL PROVIDE BOXES, CONDUIT, WIRE, AND RECONNECTIONS AS REQUIRED TO

RECONNECT ANY AND ALL EXISTING LIGHT FIXTURES, RECEPTACLES, OR DEVICES REMAINING IN

USE. REMOVAL OF ANY ELECTRICAL EQUIPMENT SHALL NOT AFFECT THE OPERATION OF

EQUIPMENT REMAINING IN USE.

CONTINUITY OF ALL SERVICES TO AND FROM THE FACILITIES IN THE EXISTING BUILDING SHALL BE MAINTAINED WITHOUT INTERRUPTION, EXCEPT FOR SUCH PERIODS OF TIME WHICH THE V.A. MAY DESIGNATE. IF TEMPORARY CONNECTIONS, ETC. ARE NECESSARY TO ASSURE THE CONTINUITY OF SERVICE, THEY SHALL BE FURNISHED WITHOUT ADDITIONAL CHARGE TO THE V.A. AND SHALL BE

REMOVED WHEN NO LONGER NECESSARY.

ALL EXISTING CONDUIT AND WIRING MADE ABANDONED BY THIS PROJECT OR FOUND TO BE

ABANDONED DURING DEMOLITION SHALL BE REMOVED BACK TO PANEL, BOARD, OR SWITCH.

COORDINATE THE PROVISION AND INSTALLATION OF ALL CONTROL WIRING FOR MECHANICAL

EQUIPMENT WITH THE GENERAL CONTRACTOR AND MECHANICAL CONTRACTOR.

FOR SAFETY PURPOSES THE CONTRACTOR WILL NOT WORK ON ANY ELECTRICAL EQUIPMENT HOT.

ALL SHUTDOWNS WILL BE SCHEDULED IN ADVANCE WITH THE COR.

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS

SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS

CONTRACTOR. ALL CONDUITS IN WALLS SHALL BE GROUTED OR SEALED INTO OPENINGS.

CONTRACTOR SHALL COORDINATE ‘IN-WALL’ & ‘OVERHEAD CEILING’ INSPECTIONS WITH COR

PRIOR TO THE INSTALLATION OF FINISHES. IN-WALL INSPECTIONS REQUIRE 24 HOUR

NOTIFICATION. OVERHEAD CEILING INSPECTIONS REQUIRE 48 HOUR NOTIFICATION.

CONTRACTOR TO SUPPLY A CART WITH A LOG SHEET AND FULL SET OF HARD COPY DRAWINGS

FOR ALL INSPECTIONS. LOG SHEET SHALL BE ITEMIZED BY TYPE OF INSPECTION AND BY ROOM.

NO SUCH FINISHES SHALL BE INSTALLED WITHOUT INSPECTION APPROVAL FROM COR

19. CONSTRUCTION MATERIALS AND INSTALLATION METHODS PROVIDED AND PERFORMED BY ALL CONTRACTORS SHALL BE IN COMPLIANCE WITH VAMC FACILITY OPERATIONS, NFPA, ICRA, ILSM, VA SPECIFICATIONS, AND AS FURTHER DESCRIBED IN THIS SCOPE.

20. PAINT ALL EXPOSED NEW AND EXISTING PIPING, CONDUIT, WIRE MOLD, ELECTRICAL PANELS, ACCESS PANELS, ETC., TO MATCH WALL FINISH UNLESS OTHERWISE NOTED.

22.

23.

24.

21.

25.

26.

27.

28.

29.

30.

31.

32.

33.

34.

35.

36.

37.

38.

39.

40.

41.

42.

43.

44.

45.

47.

48.

46.

49.

50.

51.

52.

53.

54.

55.

1/4" = 1'-0"2 Typical Control Reach Limitations 1/2" = 1'-0"1 Typical Mounting Heights

1 1/2" = 1'-0"3 Detail - Recessed Fire Extinguisher Cabinet

ALL CONTRACTOR PERSONNEL ARE REQUIRED TO OBTAIN COR ISSUED BADGE TO BE WORN

AT ALL TIMES WHILE ON VA PROPERTY. PRIOR TO THE BADGE BEING ISSUED, CONTRACTOR

PERSONNEL ARE REQUIRED TO ATTEND SFETY AND PROTOCOL TRAINING ADMINISTERED BY

THE COR AND FACILITY SAFETY OFFICER.

56.

Renovate Vacated ICU Project #: 589A4-16-101

Area 1 N.I.C

Renovate Vacated ICU Project #: 589A4-16-101

Area 1 N.I.C

Renovate Vacated Surgery Project #: 589A4-16-102

Area 2

Renovate Vacated Surgery Project #: 589A4-16-102

Area 2

3 3

4 4

4.1 4.1

5 5

5.4 5.4

6 6

6.2 6.2

6.7 6.7

7 7

8 8

9 9

10 10

N

N

M

M

F

F

G

G

Ga

Ga

H

H

Hb

Hb

J

J

Jb

Jb

K

K

L

L

La

La

N.I.C.

N.I.C.

N.I.C.

N.I.C.

Ja

Ja

Office

Office

Office

Open Office

Waiting

660A

PIV

Office

Office

Office

Office

File Room

Team Room

Office

Office

Office

Office

Open Office

Office

Office

Office

Office

Shared Office

Shared Office

Galley

Office

Office

Office

Office

Corridor

C004

C o rr id o r

C

Corridor

C003

Corridor

C001

C o p y/

S to ra g e

Closet

Clos.

Open Office

Office

Team Rm

Conference Rm

612F

Copy/ Storage

Physician Surg. Svc.

612G

Physician Surg. Svc.

612E

Physician Surg. Svc.

612D

Physician Spec. Care

612C

Elec. Closet

Physician Surg. Svc.

612B

Staff Toilet

N.I.C.

N.I.C.

Matchline See sheet 2-A1.1

Soil Dispatch

656O

Equip.

Storage

656N

625E 612A625D625C625B

625A

625F 619

Surg.

Swamp

Patient Rm

Toilet

628A

Toilet

627A

Patient Shower

Corridor

C64

Patient Rm

Patient Rm

Patient Rm

Patient Rm

Patient Rm

Patient Rm

Toilet

633A

Toilet

629A

Toilet

636A

Toilet

640A

N. Mgr.

Med. Rm

635A

Elec. Closet

670A

Toilet

645A

Patient Rm

Patient Rm

Patient Rm

Patient Rm

Rt/Work

Office

IT Rm

Resp. Care Office

Vending

Toilet

Oxygen Stg.

Corridor

C65

Corridor

C61

Nurse Station

Toilet

Waiting Area

Social Worker

631A

Change Rm

630A

Break/Lockers

Clean Dispatch

622 621 618 617

601C

Service Lobby

Soiled

Dispatch

601A

Corridor

C63

Elev. Lobby

Toilet

642A

Toilet

641A

Stairs

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

VeteransA sffair Depa frtmento

One Memorial Drive Suite 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

2/7/2018 4:32:35 PM

Overall Existing 6th Floor Plan

2-G0.2 800 Hospital Drive Columbia, MO 65201

01/19/2018

BID DOCUMENTS

BD/HT ZF

589A4-16-102Renovate Vacated Surgery, Ward 6

N

1/8" = 1'-0"1 Overall Existing 6th Floor Plan

3 3

4 4

4.1 4.1

5 5

5.4 5.4

6 6

6.2 6.2

6.7 6.7

7 7

8 8

9 9

10 10

N

N

M

M

F

F

G

G

Ga

Ga

H

H

Hb

Hb

J

JJb

K

K

L

L

La

La

2 HOUR

RATED

2 HOUR

RATED

2 HOUR

RATED

2 HR.

RATED

2 HOUR

RATED

2 HOUR

RATED

2 HOUR

RATED

2 HOUR

RATED

2 HOUR

RATED

Ja

Corridor / Vending

C66

ELT

Conference

Rm

Break Room

Corridor

C65

ELT

Storage

650A

Open Office

Files/Storage

Galley

656A

W o rk /C o p y

Office

Office

Office

Office

646Office

Office

Office

Office

Open Office

Team Room

Storage

652A Open Office

Common Conf Rm

Open Office

Office

Office

Reception / Waiting

Galley

626A

Office

Copy/Storage

Office

Open Office

Office

Office

Office

Office

Office

Office

Open Office

Restroom

632A

Team Room

Corridor

C64

Men's Restroom

Women's Restroom

HAC

T ra v e l D is ta n c e

-1

T ra v e l D is ta n c e

-1

Travel Distance = 149'-3"

Extg. Elec.

IT Closet

N.I.C.

N.I.C.

N.I.C.

N.I.C.

Travel Distance = 149'-3"

Office

Office

Office

Office

Office

Office

Office

Office

Open Office

Team Room

File Room

Copy/Storage

Office

PIV

Waiting

660A

Office

Office

Office

Office

Office

Shared Office

Shared Office

Open Office

Corridor

C63

Team Rm

Office

Copy/ Storage

Corridor

C62

Elevator Lobby

Galley

Office

Office

Office

Office

Office

Office

680C o rr id o r

C

Corridor

C002

Corridor

C002

Open Office

Corridor

C003

Corridor

C004

Closet

Clos.

Galley

602A

Corridor

C65

Service Lobby

Soiled Dispatch

601A

Central Jan.

Stg.

601B

W/C Stg.

601C

Physician Spec. Care

Physician Surg. Svc.

Physician Spec. Care

Cardiology Providers Spec. Care

Spec. Care Surg. Svc.

Chief Spec.

Care

625A Ops. Mgr.

Spec. Care

625B

Dir. Surg.

Svc.

625C

Security Surg.

Service

625D

Ops. Mgr.

Surg. Svc.

625E

Physician Surg. Svc.

612A

Physician Surg. Svc.

612B

Physician Spec. Care

612C

Physician Surg. Svc.

612D

Physician Surg. Svc.

612E

Physician Work Rm

Elec. Closet

Copy Rm

625F Janitor

Toilet

619 Staff Toilet

Physician Surg. Svc.

612G

Conference Rm

612F

Legend - Life Safety Plan

2 Hour Fire Rated Partition

1 Hour Smoke Compartment Partition

Temporary 1-HR Fire Rated Construction Partition extended to deck above

It shall be the contractor's responsibility to inspect and repair fire rated partitions.

It shall be the contractor's responsibility to inspect and repair smoke compartment partitions.

Semi-Recessed Fire Extinguisher Cabinet; See Detail 3 / 2-G0.1

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

VeteransA sffair Depa frtmento

One Memorial Drive Suite 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

2/7/2018 4:32:37 PM

6th Floor Life Safety Plan

2-G1.0 800 Hospital Drive Columbia, MO 65201

01/19/2018

BID DOCUMENTS

BD/HT ZF

589A4-16-102Renovate Vacated Surgery, Ward 6

N

1/8" = 1'-0"1 6th Floor Life Safety Plan

Code Summary:

Project Description:

Interior renovation and exterior penthouse renovation of the remaining 9706 s.f. of the 6th floor of Building #1.

The balance of the 6th floor was renovated in a recent project. The previous use of this floor was I2 - Surgerly

Applicable Codes BUILDING CODE 2015 International Building Code FIRE CODE 2015 International Fire Code PLUMBING CODE 2015 International Plumbing Code MECHANICAL CODE 2015 International Mechanical Code ELECTRICAL CODE 2015 National Electric Code ENERGY 2015 International Energy Conservation Code LIFE SAFETY 2015 NFPA 101 LIfe Safety Code ACCESSIBILITY Americans with Disability Act (ADA) - ICC/ANSI SEISMIC 117.1-20092000 VA Seismic Design Requirements H-18-8

Jurisdiction Department of Veteren Affairs (VA) Joint Commision on the Accreditation of Healthcare Organizations (JCAHO) US Department of Health and Human Services

Building Data:

Facility Address: 800 Hospital Drive, Columbia, MO 65201 Occupancy Classification: Business "B"

Construction Type: "IIB" -- Auto-Fire Suppression

Fire Protection: SPRINKLERED

Building Elements:

Type IIB: Existing Construction:Table 601 all building elements are of non-combustible materials

Fire Seperation:2 Hour Floor 2 Hour Egress Stairwell 2 Hour Vertical Shafts

Means of Egress - Chapter 10

Occupant Load: (Section 1004) Area of 6th Floor: 23,490SF Table 1004.1.1, Maximum Floor Area Allowances per Occupant:

Administrative areas (23,490 s.f. @ 100) = 234 occupants

Fire protection systems (chapter 9) automatic sprinklerprovided throughout portable extinguishing provide per international fire code fire alarm and detection systems (907)provided

Table 1005.1 - Egress width per occupant served Other = 0.2 inches per occupant x 235 occupants = 47"(existing exit width = 72")

Table 1016.2 Exit Access Travel Distance:

"B" Occupancy - w/ sprinkler system 300', Dead End Corridor 50' Max.

Plumbing Fixtures - Chapter 29

Fixture Counts: (Table 2902.1) (OCC. = 234)

Water Closets (Male) 1:25 for the first 50; 1:50 for remainder = 4 (4 provided) Water Closets (Female) 1:25 for the first 50; 1:50 for remainder = 4 (6 provided) Lavatories (Male) 1:40 for the first 80; 1:80 for remainder = 3 (3 provided) Lavatories (Male) 1:40 for the first 80; 1:80 for remainder = 3 (3 provided) Other 1 Service Sink

Existing Wall to be Demolished

Existing Wall to Remain

Existing Door to be Demolished

Existing Door to Remain

Demolition Plan Legend

Temporary 1-HR Fire Rated Construction Partition exended to deck.

Shown for reference only. Contractor to coordinate with COR appropriate locations of walls and ante rooms.

Area Not In Contract

Demo Existing Acoustical Ceiling Tile System, Light Fixtures, Sprinkler Heads, HVAC Diffusers and Ceiling Mounted Devices Completely. Refer to MEP Drawings For Additional Information.

Demo Existing Vinyl Composition Tile and Vinyl Base Completely. Prepare Area to Receive New Flooring Finish.

Remove Existing Medical Gas and Associated Hardware.

Cap Services in Wall or Below Floor.

Demo Existing Carpet Flooring and Base Completely.

Prepare Area to Receive New Flooring Finish.

Dashed Lines Indicate Approximate Layout of Existing Patient Lift Rails. Contractor To Carefully Remove Existing Equipment Rails and Supports and Return to the Owner For Future Use.

Remove Existing Plumbing Fixture(s) and Associated Hardware Completely. Cap All Services Below Floor. Re:

Plumbing Drawings for Additional Information.

Remove Existing Casework (Upper and Lower), Countertop, Plumbing Fixture and Services Completely.

Cap All Services Below Floor.

Remove Existing Medical Gas Alarm and Control Panel.

Cap All Services.

Keynote Legend - 6th Floor Demolition Plan

Demo Existing Ceramic Tile Flooring and Ceramic Base Completely. Prepare Area to Receive New Flooring Finish.

Demo Existing Sheet Vinyl Flooring and Vinyl Base Completely. Prepare Area to Receive New Flooring Finish.

Demo Existing Gypsum Board Ceiling System, Light Fixtures, Sprinkler Heads, HVAC Diffusers and Any Ceiling Mounted Devices Completely.

Demo Existing CMU Wall around existing shaft opening.

RE: MEP and Structural Drawings for Additional Demolition Information.

Remove Existing Lockers13

Coordinate work in this area with COR for after business hours. Area should be clean, tidy and usable before the start of business hours every day.

Temporary 1-HR Fire Rated Construction Parition. Extend to underside of Deck

Demo Abandoned Conduit and Concrete Housekeeping Pad. Prepare concrete slab to have a clean, smooth finish

Demo Existing Dumbwaiter Elevator Door and Frame completely for furture infill. Call Button to remain but to be deactivated by Elevator Consultant. Coordinate any Elevator shut-down time 72 hours in advance with COR.

Existing Elevator Door and Frame to Remain. Door to be locked-out. Call button to deactivated by Elevator Consultant and removed. Coordinate any Elevator shut-down time 72 hours in advance with COR.

Area of Depressed Slab shown Hatched; Remove Flooring Material and Prepare Floor for Infill.

ICU ISO

656P

ICU ISO

656R

Soil Dispatch

656O

Equip.

Storage

656N

625E 612A625D625C625B

625A

625F 619

Surg.

Swamp

Patient Rm

Toilet

628A

Toilet

627A

Patient Shower

Corridor

C64 Patient Rm

Patient Rm

Patient Rm

Patient Rm

Patient Rm

Patient Rm

Toilet

633A

Toilet

629A

Toilet

636A

Toilet

640A

N. Mgr.

Med. Rm

635A

Elec. Closet

670A

Toilet

645A

Patient Rm

Patient Rm

Patient Rm

642Patient Rm

Rt/Work

Office

IT Rm

Resp. Care Office

Vending

Toilet

Oxygen Stg.

Corridor

C65

Corridor

C61

Nurse Station

Toilet

Waiting Area

Social Worker

631A

Change Rm

630A

Break/Lockers

Clean Dispatch

622 621 618 617

601C

Service Lobby

Soiled

Dispatch

601A

Corridor

C63

Elev. Lobby

Toilet

642A

Toilet

641A

Stairs

Ante

3 3

4 4

4.1

5 5

5.4

6 6

6.2

6.7

7 7

8 8

9 9

10 10

N

N

M

M

Hb

Hb

J

Jb

K

K

L

L

La

La

N.I.C.

N.I.C.

N.I.C.

N.I.C.

Ja

13 13

131313

17 18

N.I.C.

N.I.C.

Area 1

Scope of Work

Area 2

N or th S ou th

A re a

A re a

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

VeteransA sffair Depa frtmento

One Memorial Drive Suite 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

2/7/2018 4:32:01 PM

6th Floor Demolition Plan

2-A1.0 800 Hospital Drive Columbia, MO 65201

01/19/2018

BID DOCUMENTS

BD/HT ZF

589A4-16-102Renovate Vacated Surgery, Ward 6

General Notes - Demolition Plans

A Demolition and construction must be sequenced and coordinated to ensure that the building owner's operations are continuously maintained.

B This demolition plan reflects information gathered from existing conditions drawings and architect's field observations. Contractor to verify accuracy of information and include all required demolition in their bid & report any discrepancies to the COR.

C Items to be demolished, removed, or relocated are shown dashed. Existing items to remain shall be protected during construction by contractor. Patch and repair any surfaces disturbed by demolition that are to remain.

D Remove all flooring finishes and base unless otherwise noted. Prepare slab and existing walls that are to remain for new finishes.

E Remove ceiling tile, grids, lights, associated hardware and panels. Refer to RCP Drawings for existing ceiling to remain.

F Remove all mounted wire mold and receptacles. Pull wire back to electrical panel. RE:

Electrical drawings for additional information.

G Remove all existing phone/data lines back to nearest patch panel. RE: Electrical drawings for additional information.

H Protect all medical equipment and associated medical items during construction

I All demolition and construction areas must have ante rooms as required and described in the specifications. Verify exact locations of ante rooms with COR.

J Remove all ceiling mounted curtain tracks.

K All work in corridors and elevator lobby (other than containment walls) is to be done on either weekends or after hours.

L Access to the passenger and freight elevators must be maintained at all times.

M Severe noise production work will not be allowed during normal working hours and must be scheduled with the COR for other times. This includes jack-hammering concrete, saw-cutting concrete, repetitive hammer drilling, etc.

N All existing conduit and wiring made abandoned by this project or found to be abandoned during demolition shall be removed back to the panel, board, or switch.

O All existing pneumatic transportation tubing system throught work area to be removed above ceilings and floor chases. Coordinate with COR the appropriate location to cap tube system.

N

1/8" = 1'-0"2 6th Floor Demolition Plan - Area 2

Not to Scale

Key Plan - Area 2

REF.

3 3

4 4

4.1

5 5

5.4

6 6

6.2

6.7

7 7

8 8

9 9

10 10

N

N

M

M Hb

J

JJb

K

K

L

L

La

La

2-A1.2

2-A1.3

MATCHLINE

Office

Office

Office

Office

Office

Office

Office

Office

Office

Office

Office

Office

Office

Office

Office

Office

Office

Restroom

632A

Team Room

Women's Restroom

Men's Restroom

HAC

Copy/Storage

Open Office

Reception / Waiting

Galley

626A Break Room

ELT

Conference

Rm

Corridor / Vending

C66

ELT

Storage

650A

Common Conf Rm

Files/Storage

Open Office

Office

Open Office

Work/Copy

Galley

656A

Team Room

Corridor

C64

Open Office

Open Office

Open Office

Storage

652A

Open Office

IT Closet

Extg. Elec.

A

B

620A

C65

C65

650A

627B627A

A

C63

C63

Corridor

C65

/See 1 2-A1.3

/See 1 2-A1.2

N.I.C.

N.I.C.

N.I.C.

N.I.C.

Office

N.I.C.

N.I.C.

Area 1

Scope of Work

Area 2

N or th S ou th

A re a

A re a

625E 612A625D625C625B

625A

625F 619

621 618 617

601C

Service Lobby

Soiled

Dispatch

601A

Corridor

C63

Elev. Lobby

Stairs

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

VeteransA sffair Depa frtmento

One Memorial Drive Suite 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

2/7/2018 4:32:03 PM

6th Floor Renovation Plan

2-A1.1 800 Hospital Drive Columbia, MO 65201

01/19/2018

BID DOCUMENTS

BD/HT ZF

589A4-16-102Renovate Vacated Surgery, Ward 6

N

1/8" = 1'-0"1 6th Floor Renovation Plan - Area 2 Not to Scale

Key Plan - Area 2

Existing Wall

New Wall

New Door

Existing Door

Floor Plan Legend

Area Not In Contract

Handrail & Crashrail

Temporary 1-HR Fire Rated Construction Partition exended to deck. Shown for reference only. Contractor to coordinate with COR appropriate locations of walls and ante rooms.

2-A3.1

2-A3.1

2-A3.1

2-A3.1

2-A3.1

3 3

4 4

4.1

5 5

5.4

6 6

6.2

6.7 6.7

N

N

M

M

HbJ

J

Jb

K

K

L

L

La

La

11'-3 3/4" 9'-7 7/8"

8 7/8"

9'-0 1/8" 12'-4 1/4"

2'-0 5/8"

19'-7 3/8" 9'-1 1/8" 10'-7"

9'-0" 12'-8 1/2"

11 3/4"

6'-8 3/4" ± 13'-5 1/8" V.I.F.

9'-4 7/8" 5'-4 7/8" 14'-7 3/8" 21'-8 3/4" 13'-7 1/8"

1'-2 7/8"

9'-0" 5'-4 7/8" 11'-5 3/8" 2'-6 1/4" 7'-10 1/2" 5'-10" 3'-6"

4'-0" 12'-9 1/4"

/8

/8

/4

/4

/8

/4

/8

/4

/8

/8

/4

/8

/4

/8

/8

/8

/4

/8

/8

/8

/8

/8

/8

/8

/8

/8

MATCHLINE

/See 1 2-A1.3

Ja

Office

Office

Office

646Office

Office

Office

Office

Office

Office

Office

Corridor

Office

Copy/Storage

Galley

626A

Reception / Waiting

Break Room

ELT

Conference

Rm

Corridor / Vending

C66

ELT

Storage

650A

Open Office

Team Room

Open Office

Storage

652A

Open Office

Galley

656A

Files/Storage

Work/Copy

Open Office

Office

Common Conf Rm

Corridor

C65Corridor

C64

3'-6 1/2"

A

650A

C

C

C

C

C

C

C

C

C

C

C

C

C

CC

C

C

B

B

A

G

G

G

C

C

C

C

C

B

B

C C

H

C

G

G

G

B

G

G

C

G

B

3'-0" 11" 2'-5 1/4"

A

LI

G N

/8

2'-1"

/8

M

IN

/2

/8

1'-4 1/8"

/2

/2

ALIGNA

LI

G N

A

LI

G N

B

B

G

G

CLEAR

8'-0"

6 10

6 10

6 10

6 10

3 3

G

Clear

5'-0"

5'-0"

C

C

G G

G

G

C

2 2 2 2

ALIGN

G

3 3

CC

B

B

BB

B

C

C

C

G G

G

C

Extg. Elec.

C

C C

C

IT Closet

/2

/8

C

C

C

C

C

6'-8 7/8"

G

2-A3.17

B

620A

C65

627B627A

GG

G

G1

C2 C2

C2

G2

G

G

G

HOLD

8'-0" ( + / - ) 8'-1 3/4" V.I.F.

G2C

C

C

G

C

C

GG

G

G

G2

G2

11'-6 1/8"

2'-2 1/8"

1'-2" 6'-4 1/8" 5'-1 1/2" 7'-0 1/2"

272727

N.I.C.

N.I.C.

G

2'-1" 2"

N.I.C.

N.I.C.

Area 1

Scope of Work

Area 2

N o rt h

S o u th

A re a

A re a

Align New Wall Construction with Existing Wall. Create a Smooth and Flush Finish. Paint per Room Finish Schedule

Workstation Shown for Reference only.2

Laminate 5/8" GWB to all Exposed Column Faces3

Base Cabinets and Upper Cabinets; See Elevation for more information.

BizHub Equipment by Owner. Shown for Reference only5

New Window Treatment - RS1; RE: Room Finish Schedule6

Hollow Metal Cased Opening - Painted; RE: Door Schedule

Sink; RE: Plumbing Drawings8

Keynote Legend - 6th Floor Plan

New Vending Machines by Owner; See Electrical Drawings for Additional Information.

New Solid Surface Window Sill - SS2;

(RE: Detail )

1 Hour Rated Temporary Construction Barrier Partition11

Existing 2 Hour Rated Shaft Enclosure. Maintain Fire Rating

Existing 2 Hour Rated Stairwell Enclosure. Maintain Fire Rating

Furr Out Existing Column as Required14

Existing 2 Hour Rated Elevator Shaft. Maintain Fire Rating15

Existing Door Panel to Remain. Paint Existing HM Door Frame per Room Finish Schedule

Install New Handrails @ this Wall. See Material Legend18

Install Stainless Steel Corner Guard 96" High Starting Above Scheduled Wall Base; See Detail and Material Legend

Install new Flooring per Room Finish Schedule in this Area; Coordinate work in this area with COR for after business hours. Area should be clean, tidy and usable before start of business hours every day.

Recessed Fire Extinguisher Cabinet; See20

Structural Floor In-fill; RE: S-Series Drawings for Additional Information. See

Wall Mounted Drinking Fountain with Bottle Filler. RE:

Plumbing for Additional Information

(6) Wall mounted TV's provided by General Contractor and installed by General Contractor. Provide (3) Recessed AV Boxes behind TVs. See Elevation and ELEC drawings for Additional Information. Provide FTWD Blocking behind TV's as shown on Elevations

Install 12'-0" W x 4'-0" H White Magnetic Markerboard with Satin Aluminum marker tray; See Elevation.

Ceiling Mounted Projector Screen provided and Installed by GC. See RCP for additional information. Center projector screen on wall indicated in Floor Plan.

Ceiling Mounted Projector provided and Installed by GC.

See E-Series Drawings for Additional Information. Follow Manufacturer recommendations for mounting distance and height AFF

Area of Depressed Slab Shown Hatched. Infill with Lightweight Concrete to Create a Smooth and Level Surface for New Flooring Material. See Room Finish Schedule for Flooring

Ice and Water Dispenser; See P-Series Drawings for Additional Information regarding water lines and floor drains.

18 / 2-A3.1

3 / 2-G0.1

6 / 2-A4.0

5 / 2-A4.0

Coordinate Floor Drains in this area with P-Series Drawings. Slope Flooring immediately surrounding drain towards the center of the drain.

Curved GWB Soffit Above Shown Dashed. RE: RCP30

Chase; Mimize size as much as possible. See MEP Drawings for Additional Information.

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

VeteransA sffair Depa frtmento

One Memorial Drive Suite 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

2/7/2018 4:32:06 PM

6th Floor Renovation Plan - North

2-A1.2 800 Hospital Drive Columbia, MO 65201

01/19/2018

BID DOCUMENTS

BD/HT ZF

589A4-16-102Renovate Vacated Surgery, Ward 6

General Notes - Floor Plans

A All work shown "Not In Contract" (NIC) may be accomplished by a contractor who is not included as part of the construction agreement. The GC is to coordinate with "other" contractors performing NIC work which impacts or relates to work which is part of the construction agreement.

B Patch Existing Walls to Remain As Required

C All dimensions are from column center line to face of partition UON. Under no circumstances shall any measurement be scaled from the drawings. Any measurement not given an actual number dimension should be brought to the COR's attention before proceeding.

D All demolition and construction areas must have ante rooms as required and described in the specifications. Verify exact locations of ante rooms with COR.

E All work in corridors and Elevator Lobby (other than containment wall) is either after hours or weekend work

F Access to the passenger and freight elevators must be maintained at all times

G Install 2 Hour Rated Fire-Caulk at all floor and roof penetrations.

H Severe noise production work will not be allowed during normal working hours and must be scheduled with the COR for other times. This includes jack-hammering concrete, saw-cutting concrete, repetitive hammer drilling, etc.

N

1/4" = 1'-0"1 Partial 6th Floor Plan - Area 2 - North Not to Scale

Key Plan - Area 2 North

Existing Wall

New Wall

New Door

Existing Door

Floor Plan Legend

Area Not In Contract

Handrail & Crashrail

Temporary 1-HR Fire Rated Construction Partition exended to deck. Shown for reference only. Contractor to coordinate with COR appropriate locations of walls and ante rooms.

625E625D625C625B

625A

625F 619

621 618 617

601C

Service Lobby

Corridor

C63

612A

2-A3.1

6.7

7 7

8 8

9 9

10 10

N

N

M

M Hb

J

JJb

K

K

L

L

La

La

2-A3.0

2-A3.0

/8

/4

/8

/2

/8

/8

/8

/2

/8

/8

/4

/8

/4

/2

/8

/8

/8

H O

L D

/4

9'-4 7/8" 11'-10"

8'-5 7/8" 12'-9"

9'-4 7/8" 5'-4 7/8" 10'-1 7/8" 10 5/8"

2'-6 1/4"

MATCHLINE

/See 1 2-A1.2

2-A3.0

Ja

Office

Office

Office

Office

Office

Office

Office

Office

Open Office

Women's Restroom

Men's Restroom

HAC

Open Office

Team Room

Corridor

Copy/Storage

628 Corridor

C65

Corridor

C64

2-A3.0

Restroom

632A

C

C

C

C

C

C

G

C

C

C

C

C

C

C

C G

G

C

C

C C

B B

C

C

C

C

C C

B

GG

G

H

H

C

G

G

C

C

C

C

C

C

C

C

C

G

A H

H

A

B C

B B

C2

G

C2

C

CLEAR

5'-0"

CLEAR

5'-0"

2 2

3 3

16 16

Corridor

C64

16 16

8'-0"

2-A3.1 6

A

B

C65

C65

11 17

4'-0"

G

2-A3.1

2-A3.1

G2

G2

G2

G2

2-A3.1

C63

C63

G2

Office

N.I.C.

N.I.C.

2-A3.1

C2

G G

G2

G2

G

G

N.I.C.

N.I.C.

Area 1

Scope of Work

Area 2

N or th S o u th

A re a

A re a

Align New Wall Construction with Existing Wall. Create a Smooth and Flush Finish. Paint per Room Finish Schedule

Workstation Shown for Reference only.2

Laminate 5/8" GWB to all Exposed Column Faces3

Base Cabinets and Upper Cabinets; See Elevation for more information.

BizHub Equipment by Owner. Shown for Reference only5

New Window Treatment - RS1; RE: Room Finish Schedule6

Hollow Metal Cased Opening - Painted; RE: Door Schedule

Sink; RE: Plumbing Drawings8

Keynote Legend - 6th Floor Plan

New Vending Machines by Owner; See Electrical Drawings for Additional Information.

New Solid Surface Window Sill - SS2;

(RE: Detail )

1 Hour Rated Temporary Construction Barrier Partition11

Existing 2 Hour Rated Shaft Enclosure. Maintain Fire Rating

Existing 2 Hour Rated Stairwell Enclosure. Maintain Fire Rating

Furr Out Existing Column as Required14

Existing 2 Hour Rated Elevator Shaft. Maintain Fire Rating15

Existing Door Panel to Remain. Paint Existing HM Door Frame per Room Finish Schedule

Install New Handrails @ this Wall. See Material Legend18

Install Stainless Steel Corner Guard 96" High Starting Above Scheduled Wall Base; See Detail and Material Legend

Install new Flooring per Room Finish Schedule in this Area; Coordinate work in this area with COR for after business hours. Area should be clean, tidy and usable before start of business hours every day.

Recessed Fire Extinguisher Cabinet; See20

Structural Floor In-fill; RE: S-Series Drawings for Additional Information. See

Wall Mounted Drinking Fountain with Bottle Filler. RE:

Plumbing for Additional Information

(6) Wall mounted TV's provided by General Contractor and installed by General Contractor. Provide (3) Recessed AV Boxes behind TVs. See Elevation and ELEC drawings for Additional Information. Provide FTWD Blocking behind TV's as shown on Elevations

Install 12'-0" W x 4'-0" H White Magnetic Markerboard with Satin Aluminum marker tray; See Elevation.

Ceiling Mounted Projector Screen provided and Installed by GC. See RCP for additional information. Center projector screen on wall indicated in Floor Plan.

Ceiling Mounted Projector provided and Installed by GC.

See E-Series Drawings for Additional Information. Follow Manufacturer recommendations for mounting distance and height AFF

Area of Depressed Slab Shown Hatched. Infill with Lightweight Concrete to Create a Smooth and Level Surface for New Flooring Material. See Room Finish Schedule for Flooring

Ice and Water Dispenser; See P-Series Drawings for Additional Information regarding water lines and floor drains.

18 / 2-A3.1

3 / 2-G0.1

6 / 2-A4.0

5 / 2-A4.0

Coordinate Floor Drains in this area with P-Series Drawings. Slope Flooring immediately surrounding drain towards the center of the drain.

Curved GWB Soffit Above Shown Dashed. RE: RCP30

Chase; Mimize size as much as possible. See MEP Drawings for Additional Information.

Drawing Title Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS:…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.