Bldg.11A11B.xlsx
XLSX spreadsheet 12 KB Posted
- Attached to
- H312--Base 4 Fire and Smoke Door Inspections and Repair Services at Jesse Brown VA Medical Center
- Solicitation number
- 36C25226Q0196
About this file
This file is a door schedule and location inventory for Buildings 11A and 11B at Jesse Brown VA Medical Center. The spreadsheet identifies fire and smoke doors requiring inspection and repair services under solicitation 36C25226Q0196, listing specific door identifiers, locations, and classifications across eight floors. Door types include exits (associated with stairs 6-12), storage rooms, fire barriers, mechanical rooms, and non-critical corridor doors, with identifiers such as "1235 Storage," "1300A Fire Barrier," and "cc-5302 Non Critical Corridor Door."
The associated solicitation requires inspection and repair services for fire and smoke doors to ensure compliance with VA Security Clearances, Illinois State Fire Codes, and NFPA Standards. Authorized minor repairs during inspection include installation of mutes, repair of small holes in doors and frames, door closer adjustments, removal of excessive signage, removal of material from glazing, replacement of missing screws, and installation of hinge filler plates. Any deficiencies including missing smoke seals required for compliance must be documented and included in a final report. Fire door hold-open magnets must be verified for proper release and holding function. This door schedule serves as the primary reference document for contractors to locate specific doors throughout the facility and conduct systematic inspections and repairs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25226Q0196 0002.docx | DOCX document | |
| Ogden Bldg.pdf | ||
| 36C25226Q0196 0001.docx | DOCX document | |
| Atrium Bldg.pdf | ||
| Bldg.40 BedTower.xlsx | XLSX spreadsheet | |
| Damen Bldg.pdf | ||
| Bed Tower Bldg.pdf | ||
| Taylor Bldg.pdf | ||
| Bldg1A.1B.1C.xlsx | XLSX spreadsheet | |
| 36C25226Q0196_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Floor | Door Location | Door Identifier | Floor | Door Location | Door Identifier |
| Building 11A and 11B | |||||
| B | Stair B344A | Exit | 5 | Stair 10 | Exit |
| 5 | Stair 11 | Exit | |||
| 1 | Stair 10 | Exit | 5 | Stair 12 | Exit |
| 1 | Stair 11 | Exit | 5 | Stair 9 | Exit |
| 1 | 1235 | Storage | 5 | Stair 6 | Exit |
| 1 | 1247 | Storage | 5 | Stair 7 | Exit |
| 1 | 1272 | Storage | 5 | Stair 8 | Exit |
| 1 | 1275 | Storage | 5 | cc-5302 | Non Critical Corridor Door |
| 1 | C1205 | Storage | 5 | cc-5291 | Non Critical Corridor Door |
| 1 | 1280A | Storage | |||
| 1 | 1205B | Storage | 6 | Stair 11 | Exit |
| 1 | 1210B | Storage | 6 | Stair 10 | Exit |
| 1 | 1210A | Storage | 6 | Stair 12 | Exit |
| 1 | 1210C | Storage | 6 | Stair 9 | Exit |
| 1 | 1204 | Storage | 6 | Stair 6 | Exit |
| 1 | 1199 | Storage | 6 | Stair 7 | Exit |
| 1 | 1160 | Storage | 6 | Stair 8 | Exit |
| 1 | Stair 7 | Exit | 6 | cc-6310 | Non Critical Corridor Door |
| 1 | Stair 6 | Exit | |||
| 1 | Stair 8 | Exit | 7 | Stair 11 | Exit |
| 1 | 1334 | Storage | 7 | Stair 10 | Exit |
| 1 | Stair 1300 | Fire Barrier | 7 | Stair 12 | Exit |
| 1 | Stair 9 | Exit | 7 | Stair 9 | Exit |
| 1 | cc-1294 | Non Critical Corridor Door | 7 | Stair 6 | Exit |
| 1 | cc-1295 | Non Critical Corridor Door | 7 | Stair 7 | Exit |
| 1 | 1300A-B | Fire Barrier | 7 | Stair 8 | Exit |
| 1 | 1300A-C | Fire Barrier | 7 | cc-C7301 | Exit |
| 1 | 1300A | Fire Barrier | 7 | cc-7301 | Non Critical Corridor Door |
| 1 | 1300A-D | Fire Barrier | 7 | cc-7296 | Non Critical Corridor Door |
| 1 | 1299 | Storage | |||
| 1 | 1298 | Storage | 8 | Stair 11 | Exit |
| 1 | 1285 | Storage | |||
| 1 | 1284 | Storage | |||
| 1 | 1291 | Storage | |||
| 1 | Stair 12 | Exit | |||
| 1 | 1249 | Fire Barrier | |||
| 2 | Stair 11 | Exit | |||
| 2 | Stair 10A | Exit | |||
| 2 | Stair 10B | Exit | |||
| 2 | Stair 12 | Exit | |||
| 2 | 2210 | Storage | |||
| 2 | 2204 | Storage | |||
| 2 | 2200 | Storage | |||
| 2 | cc-2261 | Non Critical Corridor Door | |||
| 2 | 2227 | Storage | |||
| 2 | 2279 | Storage | |||
| 2 | Stair 9 | Exit | |||
| 2 | 2375 | Storage | |||
| 2 | Stair 6 | Exit | |||
| 2 | 2319 | Storage | |||
| 2 | Stair 8 | Exit | |||
| 2 | 2294 | Storage | |||
| 2 | cc-22301 | Non Critical Corridor Door | |||
| 2 | cc-2295 | Non Critical Corridor Door | |||
| 2 | 2600A | Mechanical Room | |||
| 3 | Stair 10 | Exit | |||
| 3 | Stair 11 | Exit | |||
| 3 | Stair 12 | Exit | |||
| 3 | Stair 9 | Exit | |||
| 3 | 3307 | Storage | |||
| 3 | Stair 6 | Exit | |||
| 3 | Stair 7 | Exit | |||
| 3 | Stair 8 | Exit | |||
| 3 | cc-3300 | Non Critical Corridor Door | |||
| 3 | cc-3295 | Non Critical Corridor Door | |||
| 4 | Stair 12 | Exit | |||
| 4 | Stair 9 | Exit | |||
| 4 | Stair 10 | Exit | |||
| 4 | Stair 11 | Exit | |||
| 4 | 4302 | Storage | |||
| 4 | Stair 6A | Exit | |||
| 4 | Stair 6B | Exit | |||
| 4 | Stair 7 | Exit | |||
| 4 | Stair 8 | Exit | |||
| 4 | cc-4297 | Non Critical Corridor Door | |||
| 4 | cc-4295A | Non Critical Corridor Door |