Presolicitation Notice Presolicitation Notice

SUBJECT*
676-21-704 EHRM Next Gen Wifi

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
53214-1476
SOLICITATION NUMBER*
36C25222Q0857
RESPONSE DATE/TIME/ZONE
08-16-2022 12PM MOUNTAIN TIME, DENVER, USA
ARCHIVE
90 DAYS AFTER THE RESPONSE DATE
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
Z1DA
NAICS CODE*
238210
PLACE OF PERFORMANCE
Tomah VA Medical Center

POSTAL CODE

COUNTRY

CONTACT INFORMATION

CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Great Lakes Acquisition Center (GLAC) 115 S 84th Street, Suite 101

Milwaukee WI 53214-1476

POINT OF CONTACT*

Contract Officer Amy Burger amy.burger@va.gov

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Solicitation is forthcoming.

Site Visit, Thursday, August 18, 2022 from 2PM TO 3PM. Short Notice is to assure award by Sept. 30, 2022.

CONSTRUCTION SCOPE OF WORK

EHRM NEXTGEN WIFI UPGRADES

PROJECT NO: 676-21-704

PROJECT NAME: EHRM NextGen WiFi Upgrades – Tomah, WI

1. GENERAL INTENT:

The Contractor shall furnish all labor, tools, materials, and equipment to support installation of replacement and new WiFi Access Points at Tomah VA Medical Center campus located at 500 East Veterans Street, Tomah, WI. The AT&T NextGen WiFi Contractor is responsible for the bulk of the work under a separate OI&T contract. Please note that the scope of this work is limited and specifically as listed below.

2. STATEMENT OF WORK:

Provide and install conduit, raceways, horizontal and vertical penetrations, and fire stopping to support NextGen WiFi installation on the Tomah VA campus as shown and described in the project drawings and specifications. A list of required conduits and/or penetrations are provided in Appendix 1.

Work shall include:

1. Total estimated length of conduit to install is 1,024 linear feet, including junction boxes, pull cords, and fire stopping, throughout the Medical Center.

2. Work shall be performed during business hours, Monday thru Friday, 8 AM to 4:30 PM.

3. Conduit, straps and screws must be white in color. Final mounting location of conduit must

3. PERIOD OF PERFORMANCE:

3.1 Work timelines and completion progress shall be communicated to the COR for tracking purposes on a weekly basis. With work being completed in 60 days from notice to proceed.

4. REFERENCES:

1. attached drawings sets for general conduit run location.

5. SPECIFICATIONS:

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00General Requirements
01 32 16.15Project Schedule
01 33 23Shop Drawings, Product Data, and Samples
01 35 26Safety Requirements
01 74 19Construction Waste Management

DIVISION 07 – THERMAL AND MOISTURE PROTECTION

07 84 00 Firestopping

DIVISION 27 – COMMUNICATIONS

27 05 11Requirements for Communications Installations
27 05 33Raceways and Boxes for Communications Systems
27 15 00Communications Structured Cabling

6. SUBMITTALS:

a. The contractor shall submit the following submittals for review:

1) Product data and sample of conduit or raceway.

2) As-built drawings for all conduit run locations and final end location.

6. ATTACHMENTS:

6.1Attachment 1: NextGen WiFi Access Point location drawings
6.2Attachment 2: Specifications

The above paragraphs constitute a basic outline of the work to be accomplished and in no way comprises all the details for this project. Contractor shall refer to drawings and specifications for comprehensive construction requirements. The C&A requirements do not apply, and that a security Accreditation is Package is not required.

Appendix 1: Conduit Installation Checklist

Site
Bldg.
Floor
Area
Issue to be Addressed
Complete
VAMC
32
B
Hallway above 007
VA to provide conduit pathway from IT closet B32-F1-110 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP04 location
Yes |_|
VAMC
36
1
107C
VA to provide conduit pathway from IT closet 110 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP01 location
Yes |_|
VAMC
400
1
1030
VA to provide conduit pathway from IT closet 1068 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated vertically on wall at AP32 location
Yes |_|
VAMC
400
1
1013
VA to provide conduit pathway from IT closet 1068 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated vertically on wall at AP33 location for room containing hard ceiling
Yes |_|
VAMC
401
1
1184
VA to provide conduit pathway from IT closet 1145A to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP02 new location
Yes |_|
VAMC
401
1
1183
VA to provide conduit pathway from IT closet 1145A to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP21 location
Yes |_|
VAMC
402
1
1229
VA to provide conduit pathway from IT closet 1221 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated vertically at AP10 new location
Yes |_|
VAMC
403
1
1300
VA to provide conduit pathway from IT closet 1329 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated vertically on wall at AP24 location
Yes |_|
VAMC
403
1
1375
VA to provide conduit pathway from IT closet 1329 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated vertically on wall at AP27 location
Yes |_|
VAMC
405
1
10510
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP11 location
Yes |_|
VAMC
405
1
10511
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP12 location
Yes |_|
VAMC
405
1
10517
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP13 location
Yes |_|
VAMC
405
1
10523
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP14 location
Yes |_|
VAMC
405
1
10528
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP16 location
Yes |_|
VAMC
405
2
20593
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP02 location
Yes |_|
VAMC
405
2
20508
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP07 location
Yes |_|
VAMC
405
2
20510
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP08 location
Yes |_|
VAMC
405
2
20511
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP09 location
Yes |_|
VAMC
405
2
20517
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP10 location
Yes |_|
VAMC
405
2
20520
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP11 location
Yes |_|
VAMC
405
2
20523
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP12 location
Yes |_|
VAMC
405
2
20537
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP21 location
Yes |_|
VAMC
405
2
20539
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP21 location
Yes |_|
VAMC
405
2
20543
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP21 location
Yes |_|
VAMC
405
2
20584
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP17 location
Yes |_|
VAMC
405
2
20577
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP18 location
Yes |_|
VAMC
405
2
20581
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP19 location
Yes |_|
VAMC
405
2
20587
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP20 location
Yes |_|
VAMC
405
2
20588
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP21 location
Yes |_|
VAMC
405
3
30595
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP02 location
Yes |_|
VAMC
405
3
30512
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP06 location
Yes |_|
VAMC
405
3
30511
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP07 location
Yes |_|
VAMC
405
3
30515
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP08 location
Yes |_|
VAMC
405
3
30520
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP09 location
Yes |_|
VAMC
405
3
30521
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP10 location
Yes |_|
VAMC
405
3
30525
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP11 location
Yes |_|
VAMC
405
3
30537
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP12 location
Yes |_|
VAMC
405
3
30539
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP13 location
Yes |_|
VAMC
405
3
30543
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP14 location
Yes |_|
VAMC
405
3
30545
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP15 location
Yes |_|
VAMC
405
3
30546
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP21 location
Yes |_|
VAMC
405
3
30583
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP17 location
Yes |_|
VAMC
405
3
30588
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP18 location
Yes |_|
VAMC
405
3
30583
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP17 location
Yes |_|
VAMC
405
3
30588
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP18 location
Yes |_|
VAMC
405
3
30587
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP19 location
Yes |_|
VAMC
405
3
30593
VA to provide conduit pathway from drop ceiling hallway to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at new AP20 location
Yes |_|
VAMC
407
1
1746
VA to provide conduit pathway from IT closet 1735 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP19 location
Yes |_|
VAMC
407
1
1741
VA to provide conduit pathway from IT closet 1735 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP23 location
Yes |_|
VAMC
407
2
20715
VA to provide conduit pathway from IT closet 2774 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP06 location
Yes |_|
VAMC
407
2
20711
VA to provide conduit pathway from IT closet 2774 to designed AP location, in glued tile ceiling area, with 4-11/16” dual gang box situated horizontally at AP10 new location
Yes |_|
VAMC
407
2
20736
VA to provide conduit pathway from IT closet 2774 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP17 new location
Yes |_|
VAMC
407
2
20737
VA to provide conduit pathway from IT closet 2774 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP22 location for room containing hard ceiling
Yes |_|
VAMC
407
3
3786
VA to provide conduit pathway from IT closet 3772A to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP07 new location
Yes |_|
VAMC
407
3
3738
VA to provide conduit pathway from IT closet 3772A to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP08 location
Yes |_|
VAMC
408
1
1837
VA to provide conduit pathway from IT closet 1837 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP04 new location
Yes |_|
VAMC
408
2
2826
VA to provide conduit pathway from IT closet 2848 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP24 location
Yes |_|
VAMC
423
1
101
VA to provide conduit pathway from IT closet 100 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP01 location
Yes |_|
VAMC
424
1
5C17
VA to provide conduit pathway from IT closet 1506 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP20 new location
Yes |_|
VAMC
424
1
1531
VA to provide conduit pathway from IT closet 1506 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP21 new location
Yes |_|
VAMC
trE
1
Upper right
VA to provide conduit pathway from IT closet 1506 to designed AP location, in open and hard ceiling area, with 4-11/16” dual gang box situated horizontally at AP02 location
Yes |_|