This pre-solicitation notice is for a construction project to replace two 1,000-pound chiller systems at the Captain James A Lovell Federal Health Care Center in North Chicago, Illinois. The project requires replacing the chillers, associated pumps, motors, piping, instrumentation, controls and other materials and systems as described in the specifications and drawings. The period of performance is 249 calendar days after notice to proceed. The estimated price range for construction is between $2,000,000 to $5,000,000. The solicitation will be issued on July 23, 2021 with a bid opening on August 23, 2021. This opportunity is set aside for service-disabled veteran-owned small businesses. Bidders must represent that they are an SDVOSB or VOSB verified in the VIP database at the time of submission. The North American Industry Classification code is 238220 for plumbing, heating and air conditioning contractors with a $16.5 million small business size standard.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6.00

MINIMUM

CLEARANCE

49.22

DOOR OPEN 90

M

IN

IM

UM

6.

C

LE

A

RA

N C

E

.75

12.00

7.00

1.50

10.50

7.

19.00

1.

00 25

.53

29.92

TOP & BOTTOM MTG.

.53

49.55

MOUNTING

.5

P1000, W4, TYPE 1

JDE

DDG

BJJ

JDE 8/26/13

12/3/13

11/27/13

DD.P1.1.W4.01

OF

DIMENSION DRAWING,

11/27/13

MATERIAL#

PAGE

00A

DRAWING #:

SIZE REVISION

TITLE:DATEDRAWN:

DATECHECKED:

DATETECH:

DATE

DATEORIGINAL DESIGN:

OF YASKAWA AMERICA INC.

WITHOUT THE EXPRESS WRITTEN CONSENT

COPIED OR DISCLOSED IN WHOLE OR IN PART

IN IT ARE CONFIDENTIAL, AND CANNOT BE

THIS DOCUMENT AND INFORMATION CONTAINED

1APPROVED:

AIR FLOW

REVISIONS

REV. DESCRIPTION ECR# DRAWN

BY DATE

00 INITIAL RELEASE --- JDE 11/27/13

NOTES:

A. FOR REFERENCE ONLY UNLESS PROPERLY ENDORSED.

FOR ADDITIONAL DETAILS AND SPECIFICATIONS,

CONSULT WITH FACTORY.

B. DIMENSIONS ARE IN INCHES [MILLIMETERS]

C. HATCHED AREA INDICATES PERMISSIBLE CONDUIT

ENTRY AREA.

D. FANS, FILTERS OR CLOSING PLATES ARE SUPPLIED WHEN

OPTION MIX NECESSITATES.

16.44

36.00

18.15

7.41

50.82

1.50

AIR FLOW

DISCONNECT

HANDLE

28.28

32.00

32.58

Prepared by jumeil_edwards 12/10/2013 10:25:25 AM

File details come from the government source that posted it. Updated .