36C25219B0032-005.pdf
PDF 16 MB Posted
- Attached to
- Oncology Renovation USP 800 556-17-014
- Solicitation number
- 36C25219B0032
About this file
36C25219B0032 556-17-014 Drawings Set 1.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25219C0108-000.docx | DOCX document | |
| 36C25219B0032-0001000.docx | DOCX document | |
| 36C25219B0032-0001005.jpg | JPG image | |
| 36C25219B0032-0001009.jpg | JPG image | |
| 36C25219B0032-0001006.jpg | JPG image | |
| 36C25219B0032-0001003.jpg | JPG image | |
| 36C25219B0032-0001004.jpg | JPG image | |
| 36C25219B0032-0001002.jpg | JPG image | |
| 36C25219B0032-0001008.jpg | JPG image | |
| 36C25219B0032-0001001.jpg | JPG image | |
| 36C25219B0032-0001007.jpg | JPG image | |
| 36C25219B0032-004.pdf | ||
| 36C25219B0032-003.docx | DOCX document | |
| 36C25219B0032-006.pdf | ||
| 36C25219B0032-000.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
NO. DESCRIPTION DATE
BLDG. 133
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
Department of Veterans Affairs
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
B
A
C
D
E
F
COVER SHEET AND DRAWING INDEX
GI001
JJPBH
556-17-014
STRUCTURAL
ABBREVIATIONS AND NOTES
S-001
RPER
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
NO. DESCRIPTION DATE
BLDG. 133
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
Department of Veterans Affairs
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
B
A
C
D
E
F
9 10
G
9 10
F
G
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
NO. DESCRIPTION DATE
BLDG. 133
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
FOR BID - NOT FOR CONSTRUCTION
NORTH
FULLY SPRINKLERED
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
Department of Veterans Affairs
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
B
A
C
D
E
F
KEYPLAN
LEVEL 4
STRUCTURAL
PARTIAL 4TH FLOOR PLAN
SF104
RPER
G
F
G
9 1087 9 1087
9 109 10
F
G
F
G
9 1087 9 1087
F
E
F
E
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
NO. DESCRIPTION DATE
BLDG. 133
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
FOR BID - NOT FOR CONSTRUCTION
NORTH
FULLY SPRINKLERED
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
Department of Veterans Affairs
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
B
A
C
D
E
F
KEYPLAN
PENTHOUSE
STRUCTURAL
PARTIAL ROOF & PENTHOUSE PLANS
SF105
RPER
556-17-014
NO. DESCRIPTION DATE
BLDG. 133
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
Department of Veterans Affairs
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
B
A
C
D
E
F
STRUCTURAL
SECTIONS AND DETAILS
S-501
DSER
AMBULATORY HEALTHCARE
OCCUPANCY
BUILDING 133CA
BUILDING 133
BUSINESS OCCUPANCY
FIRE WALL
MGV
M G
V M
G V
M G
V
M G
V M
G V
MGV
M G
P
P
P
P
P
P
P
P
P
P P
P
P
P
P
DNDN
UPUP
AHU 6
AHU 7
AHU 9
AHU 5
1E-102
EXST.
LOBBY
C1-167
EXST. CORR.
C1-160
EXST.
ELEV.
LOBBY
C1-161
EXST.
SERVICE
LOBBY
C1-162
EXST.
CORR.
NO 1
STAIR EL-S09
ELEV.
1B-117A
EXST.
ITD
ROOM
C1-177
EXST.
WAITING
ROOM
C1-175
EXST.
CORR.
C1-176
EXST.
CORR.
C1-166
EXST.
LOBBY
ACCESS TO ITD ROOM FOR LENEL
SYSTEM CONNECTION.
AREA OF CONSTRUCTION
AREAS IN THE SCOPE OF WORK OF THIS PROJECT. THESE
AREAS INCLUDE NEW CONSTRUCTION.
AREA OF DISTURBANCE
AREAS THAT WILL BE IMPACTED BY THE BASE BID OF WORK
OF THIS PROJECT. THESE AREAS INCLUDE BUT ARE NOT
LIMITED TO AREAS THAT WILL BE SHUT DOWN, ACCESSED,
OR DISRUPTED DURING CONSTRUCTION.
ELEVATOR AND STAIR FOR CONSTRUCTION WASTE
ELEVATOR AND STAIR DESIGNATED FOR TRANSPORTATION
OF CONSTRUCTION WASTE.
CONSTRUCTION OFFICE:
AREA DESIGNATED AS THE CONSTRUCTION OFFICE.
A Serv ic e
D is ab l e d Ve t e ran Owned Sma ll Bus iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NORTH
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
BLDG. 133
Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER. INFECTION CONTROL PLAN
R-1 01/18/19
JAMES A. LOVELL FEDERAL HEALTH
CENTER-NORTH CHICAGO, ILLINOIS
REF HRQ
1" = 20'-0"F1 FLOOR 1 INFECTION CONTROL PLAN
SHEET NOTES
LEGEND
1. COORDINATE INFECTION CONTROL PROCEDURES WITH THE
VA/FHCC INFECTION CONTROL MANAGER.
2. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING TEMPORARY
CONTAINMENT PARTITIONS AND TEMPORARY VENTILATION SYSTEMS
REQUIRED TO PREVENT SPREAD OF DUST FROM CONSTRUCTION
AREA TO OCCUPIED AREAS OF THE BUILDING. SEE MECHANICAL
PLANS FOR ADDITIONAL INFORMATION. OCCUPIED AREAS SHALL
REMAIN DUST FREE THROUGHOUT CONSTRUCTION.
3. THE CONTRACTOR SHALL MAINTAIN THE AFFECTED AREAS OF THIS
BUILDING (INCLUDE MATERIAL TRANSPORT ROUTES) CLEAN AND
DUST SURFACES. THE CONTRACTOR SHALL COORDINATE WITH THE
INFECTION CONTROL STAFF PRIOR TO THE START OF
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COMPLIANCE WITH ALL INFECTION CONTROL RECOMMENDATIONS
AND REQUIREMENTS.
4. THE FACILITY WILL REMAIN OCCUPIED THROUGHOUT THE
CONSTRUCTION PERIOD. THE CONTRACTOR SHALL TAKE EVERY
PRECAUTION TO ENSURE THE UNINTERRUPTED OPERATION OF THE
FACILITY, STAFF, PATIENTS, AND VISITORS. THE CONTRACTOR SHALL
COORDINATE ALL WORK, CONSTRUCTION, PATHWAYS, ELEVATORS
USAGE, AND UTILITY INTERRUPTION WITH FHCC/VA, PM, AND/OR
FACILITIES DIRECTOR.
5. THE CONTRACTOR SHALL MAINTAIN THE REQUIREMENTS OF A
CLASS IV SYSTEM INFECTION CONTROL SYSTEM AS DEFINED IN
SPECIFICATION SECTION 01 35 26 AND THE ICRA.
6. TEMPORARY PARTITION:
A. THE CONTRACTOR SHALL DETERMINE WHERE TEMPORARY
PARTITIONS ARE REQUIRED TO MEET CLASS IV INFECTIONS
CONTROL REQUIREMENTS, FACILITY OPERATIONS, AND
CONTRACTOR SCHEDULING.
B. CLASS IV IC REQUIRES AN ANTE ROOM.
C. PARTITIONS OUTSIDE THE CONSTRUCTION AREA SHALL BE
STARC SYSTEMS (OR EQUAL) PANEL SYSTEM WITH PRESSURE
MONITOR PORTS AND DATA RECORDING.
7. OFF HOURS ARE DEFINED AS 7:00PM-3:00 AM. MINIMIZE TIME FRAME
TO THE GREATEST EXTENTS POSSIBLE. CONTRACTOR TO
COORDINATE WITH CONSTRUCTION MANAGER PRIOR TO
COMENCEMENT OF AFTER HOURS WORK.
8. TEMPORARY PARTITIONS SHALL BE SMOKE TIGHT CONSTRUCTION
OF GYPSUM BOARD OR OTHER NON-COMBUSTIBLE OR LIMITED-
COMUBSTIBLE MATERIAL. PARTITIONS SHALL BE FULL HEIGHT,
EXTENDING THROUGH SUSPENDED CEILINGS TO THE FLOOR SLAB
OR ROOF DECK ABOVE AND SHALL BE 1-HOUR RATED, UNLESS
SPRINKLERS ARE OPERATIONAL ON BOTH SIDES OF THE
TEMPORARY PARTITION, WHEREUPON THE PARTITIONS MAY BE
PERMITTED TO TERMINATE AT THE CEILING. WHERE THE CEILING ON
ONE SIDE OF THE TEMPORARY CONSTRUCTION BARRIER HAS BEEN
REMOVED, THE TEMPORARY PARTITION MUST EXTEND TO THE DECK
ABOVE AND BE 1-HOUR RATED.
jphelan Rectangle
P
P
P
P
P
P P
P
P
P
M G
P M
G V
M G
P M
G V
MGV
MGV
MGV
MGV
M G
P
SDSD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
- MAINTAIN CLASS IV REQUIREMENTS
- INSTALLATION OF PARTITIONS/
BARRIERS TO OCCUR DURING OFF-
HOURS
- LIMIT WORK IN THIS AREA TO 7
CALENDAR DAYS MAXIMUM
- COORDINATE ALL WORK WITH COR
TEMPORARY PARTIONS SHOWN
FOR REFERENCE ONLY. COORDINATE
FINAL LOCATION AND ANY ADDITIONAL
INFECTION CONTROL REQUIREMENTS
PRIOR TO CONSTRUCTION WITH
VA CONSTRUCTION MANAGER, LIFE
SAFETY, AND INFECTION CONTROL
STAFF.
EXST.
NOURISH
2A-151B
EXST.
STORAGE
2A-151C
EXST. PACU
C2-213
EXST.
HOLD1
2A-151E
EXST.
HOLD2
2A-151F
EXST.
HOLD3
2A-151G
EXST.
HOLD4
2A-151H
EXST. NURSE
STATION
2A-151
EXST.
CORR
2A-130
EXST.
CORR
C2-209
EXST.
CORR
C2-208
EXST.
CORR
C2-209
EXST.
LOBBY
C2-207
EXST.
CHECK-IN
2A-119
EXST. NURSE
STATION
2A-150
ELEV.
LOBBY
C2-232
EXST.
CORR.
C2-231
STAIR
NO. 1
STAIR
NO.2
ELEV.
EL-S09
EXST.
CORR
C2-204
EXST. ITD
ROOM
2B-110
ACCESS TO ITD FOR CONDUIT FOR
LENEL SYSTEM WIRING TO PASS-
THROUGH.
NOTE: ALL WORK ASSOCIATED WITH THE
2ND FLOOR MUST BE COMPLETED
DURING OFF-HOURS.
AREA OF CONSTRUCTION
AREAS IN THE SCOPE OF WORK OF THIS PROJECT. THESE
AREAS INCLUDE NEW CONSTRUCTION.
AREA OF DISTURBANCE
AREAS THAT WILL BE IMPACTED BY THE BASE BID OF WORK
OF THIS PROJECT. THESE AREAS INCLUDE BUT ARE NOT
LIMITED TO AREAS THAT WILL BE SHUT DOWN, ACCESSED,
OR DISRUPTED DURING CONSTRUCTION.
ELEVATOR AND STAIR FOR CONSTRUCTION WASTE
ELEVATOR AND STAIR DESIGNATED FOR TRANSPORTATION
OF CONSTRUCTION WASTE.
CONSTRUCTION OFFICE:
AREA DESIGNATED AS THE CONSTRUCTION OFFICE.
A Serv ic e
D is ab l e d Ve t e ran Owned Sma ll Bus iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NORTH
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
BLDG. 133
Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER. INFECTION CONTROL PLAN
R-2 01/18/19
JAMES A. LOVELL FEDERAL HEALTH
CENTER-NORTH CHICAGO, ILLINOIS
REF HQR
3/32" = 1'-0"F1 FLOOR 2 INFECTION CONTROL PLAN
SHEET NOTES
LEGEND
1. COORDINATE INFECTION CONTROL PROCEDURES WITH THE VA/FHCC
INFECTION CONTROL MANAGER.
2. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING TEMPORARY
CONTAINMENT PARTITIONS AND TEMPORARY VENTILATION SYSTEMS
REQUIRED TO PREVENT SPREAD OF DUST FROM CONSTRUCTION
AREA TO OCCUPIED AREAS OF THE BUILDING. SEE MECHANICAL
PLANS FOR ADDITIONAL INFORMATION. OCCUPIED AREAS SHALL
REMAIN DUST FREE THROUGHOUT CONSTRUCTION.
3. THE CONTRACTOR SHALL MAINTAIN THE AFFECTED AREAS OF THIS
BUILDING (INCLUDE MATERIAL TRANSPORT ROUTES) CLEAN AND
DUST SURFACES. THE CONTRACTOR SHALL COORDINATE WITH THE
INFECTION CONTROL STAFF PRIOR TO THE START OF
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COMPLIANCE WITH ALL INFECTION CONTROL RECOMMENDATIONS
AND REQUIREMENTS.
4. THE FACILITY WILL REMAIN OCCUPIED THROUGHOUT THE
CONSTRUCTION PERIOD. THE CONTRACTOR SHALL TAKE EVERY
PRECAUTION TO ENSURE THE UNINTERRUPTED OPERATION OF THE
FACILITY, STAFF, PATIENTS, AND VISITORS. THE CONTRACTOR SHALL
COORDINATE ALL WORK, CONSTRUCTION, PATHWAYS, ELEVATORS
USAGE, AND UTILITY INTERRUPTION WITH FHCC/VA, PM, AND/OR
FACILITIES DIRECTOR.
5. THE CONTRACTOR SHALL MAINTAIN THE REQUIREMENTS OF A CLASS
IV SYSTEM INFECTION CONTROL SYSTEM AS DEFINED IN
SPECIFICATION SECTION 01 35 26 AND THE ICRA.
6. TEMPORARY PARTITION:
A. THE CONTRACTOR SHALL DETERMINE WHERE TEMPORARY
PARTITIONS ARE REQUIRED TO MEET CLASS IV INFECTIONS
CONTROL REQUIREMENTS, FACILITY OPERATIONS, AND
CONTRACTOR SCHEDULING.
B. CLASS IV IC REQUIRES AN ANTE ROOM.
C. PARTITIONS OUTSIDE THE CONSTRUCTION AREA SHALL BE
STARC SYSTEMS (OR EQUAL) PANEL SYSTEM WITH PRESSURE
MONITOR PORTS AND DATA RECORDING.
7. OFF HOURS ARE DEFINED AS 7:00PM-3:00 AM. MINIMIZE TIME FRAME
TO THE GREATEST EXTENTS POSSIBLE. CONTRACTOR TO
COORDINATE WITH CONSTRUCTION MANAGER PRIOR TO
COMENCEMENT OF AFTER HOURS WORK.
8. TEMPORARY PARTITIONS SHALL BE SMOKE TIGHT CONSTRUCTION
OF GYPSUM BOARD OR OTHER NON-COMBUSTIBLE OR LIMITED-
COMUBSTIBLE MATERIAL. PARTITIONS SHALL BE FULL HEIGHT,
EXTENDING THROUGH SUSPENDED CEILINGS TO THE FLOOR SLAB
OR ROOF DECK ABOVE AND SHALL BE 1-HOUR RATED, UNLESS
SPRINKLERS ARE OPERATIONAL ON BOTH SIDES OF THE
TEMPORARY PARTITION, WHEREUPON THE PARTITIONS MAY BE
PERMITTED TO TERMINATE AT THE CEILING. WHERE THE CEILING ON
ONE SIDE OF THE TEMPORARY CONSTRUCTION BARRIER HAS BEEN
REMOVED, THE TEMPORARY PARTITION MUST EXTEND TO THE DECK
ABOVE AND BE 1-HOUR RATED.
HEALTHCARE OCCUPANCY
BUILDING 133CA
BUILDING 133
BUSINESS OCCUPANCY
M G
P M
G V
SDSD
SD
SD
SD
SD
SD
SD
SDSD
SD
SD
P
P
P
P
REMOVE WINDOW(S) FOR NEGATIVE
PRESSURE EXHAUST. TEMPORARILY
INFILL OPENING WITH PLYWOOD
AND ADAPTER FOR AIR EXHAUST.
- MAINTAIN CLASS IV REQUIREMENTS
- INSTALLATION OF PARTITIONS/
BARRIERS TO OCCUR DURING OFF-
HOURS
TEMPORARY PARTITIONS SHOWN
FOR REFERENCE ONLY. COORDINATE
FINAL LOCATION AND ANY ADDITIONAL
INFECTION CONTROL REQUIREMENTS
PRIOR TO CONSTRUCTION WITH
VA CONSTRUCTION MANAGER, LIFE SAFETY,
AND INFECTION CONTROL STAFF.
EQ
EQ
3A-159
PHARM
OFF.
3A-160
PHARM
OFF. 3A-164
EXST
RECP.
3A-165
EXST
PHARM.
3A-166
EXST
WAITING
3A-166A
EXST
RESTROOM
C3-139
EXST.
CORR.
3A-162
EXST.
WAITING.
3A-162
EXST.
WAITING.
C3-140
EXST.
CORR.
C3-137
EXST.
CORR.
C3-128
EXST.
ELEV.
LOBBY
NO. 1
STAIR
C3-130
EXST.
SERVICE
LOBBY
C3-129
EXST.
CORR.
C3-136
EXST.
CORR.
NO. 2
STAIR
EL-S09
ELEV.
TEMPORARY ZIPPERED 2' WIDE ENCLOSURE
FOR DEMOLITION AND INFILL OF DOORWAY
ONLY. MAXIMUM DURATION 7 CALENDAR DAYS
C3-153
EXST.
CORR.
3B-123
EXST. ITD
ROOM
ACCESS ITD
ROOM FOR CARD
READER.
AREA OF CONSTRUCTION
AREAS IN THE SCOPE OF WORK OF THIS PROJECT. THESE
AREAS INCLUDE NEW CONSTRUCTION.
AREA OF DISTURBANCE
AREAS THAT WILL BE IMPACTED BY THE BASE BID OF WORK
OF THIS PROJECT. THESE AREAS INCLUDE BUT ARE NOT
LIMITED TO AREAS THAT WILL BE SHUT DOWN, ACCESSED,
OR DISRUPTED DURING CONSTRUCTION.
ELEVATOR AND STAIR FOR CONSTRUCTION WASTE
ELEVATOR AND STAIR DESIGNATED FOR TRANSPORTATION
OF CONSTRUCTION WASTE.
CONSTRUCTION OFFICE:
AREA DESIGNATED AS THE CONSTRUCTION OFFICE.
A Serv ic e
D is ab l e d Ve t e ran Owned Sma ll Bus iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NORTH
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
BLDG. 133
Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER. INFECTION CONTROL PLAN
R-3 01/18/19
JAMES A. LOVELL FEDERAL HEALTH
CENTER-NORTH CHICAGO, ILLINOIS
REF HQR
3/32" = 1'-0"F1 FLOOR 3 INFECTION CONTROL PLAN
SHEET NOTES
LEGEND
1. COORDINATE INFECTION CONTROL PROCEDURES WITH THE
VA/FHCC INFECTION CONTROL MANAGER.
2. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING TEMPORARY
CONTAINMENT PARTITIONS AND TEMPORARY VENTILATION SYSTEMS
REQUIRED TO PREVENT SPREAD OF DUST FROM CONSTRUCTION
AREA TO OCCUPIED AREAS OF THE BUILDING. SEE MECHANICAL
PLANS FOR ADDITIONAL INFORMATION. OCCUPIED AREAS SHALL
REMAIN DUST FREE THROUGHOUT CONSTRUCTION.
3. THE CONTRACTOR SHALL MAINTAIN THE AFFECTED AREAS OF THIS
BUILDING (INCLUDE MATERIAL TRANSPORT ROUTES) CLEAN AND
DUST SURFACES. THE CONTRACTOR SHALL COORDINATE WITH THE
INFECTION CONTROL STAFF PRIOR TO THE START OF
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COMPLIANCE WITH ALL INFECTION CONTROL RECOMMENDATIONS
AND REQUIREMENTS.
4. THE FACILITY WILL REMAIN OCCUPIED THROUGHOUT THE
CONSTRUCTION PERIOD. THE CONTRACTOR SHALL TAKE EVERY
PRECAUTION TO ENSURE THE UNINTERRUPTED OPERATION OF THE
FACILITY, STAFF, PATIENTS, AND VISITORS. THE CONTRACTOR SHALL
COORDINATE ALL WORK, CONSTRUCTION, PATHWAYS, ELEVATORS
USAGE, AND UTILITY INTERRUPTION WITH FHCC/VA, PM, AND/OR
FACILITIES DIRECTOR.
5. THE CONTRACTOR SHALL MAINTAIN THE REQUIREMENTS OF A
CLASS IV SYSTEM INFECTION CONTROL SYSTEM AS DEFINED IN
SPECIFICATION SECTION 01 35 26 AND THE ICRA.
6. TEMPORARY PARTITION:
A. THE CONTRACTOR SHALL DETERMINE WHERE TEMPORARY
PARTITIONS ARE REQUIRED TO MEET CLASS IV INFECTIONS
CONTROL REQUIREMENTS, FACILITY OPERATIONS, AND
CONTRACTOR SCHEDULING.
B. CLASS IV IC REQUIRES AN ANTE ROOM.
C. PARTITIONS OUTSIDE THE CONSTRUCTION AREA SHALL BE
STARC SYSTEMS (OR EQUAL) PANEL SYSTEM WITH PRESSURE
MONITOR PORTS AND DATA RECORDING.
7. OFF HOURS ARE DEFINED AS 7:00PM-3:00 AM. MINIMIZE TIME FRAME
TO THE GREATEST EXTENTS POSSIBLE. CONTRACTOR TO
COORDINATE WITH CONSTRUCTION MANAGER PRIOR TO
COMMENCEMENT OF AFTER HOURS WORK.
8. TEMPORARY PARTITIONS SHALL BE SMOKE TIGHT CONSTRUCTION
OF GYPSUM BOARD OR OTHER NON-COMBUSTIBLE OR LIMITED-
COMBUSTIBLE MATERIAL. PARTITIONS SHALL BE FULL HEIGHT,
EXTENDING THROUGH SUSPENDED CEILINGS TO THE FLOOR SLAB
OR ROOF DECK ABOVE AND SHALL BE 1-HOUR RATED, UNLESS
SPRINKLERS ARE OPERATIONAL ON BOTH SIDES OF THE
TEMPORARY PARTITION, WHEREUPON THE PARTITIONS MAY BE
PERMITTED TO TERMINATE AT THE CEILING. WHERE THE CEILING ON
ONE SIDE OF THE TEMPORARY CONSTRUCTION BARRIER HAS BEEN
REMOVED, THE TEMPORARY PARTITION MUST EXTEND TO THE DECK
ABOVE AND BE 1-HOUR RATED.
9. CONTRACTOR SHALL INSTALL (1) VA FURNISHED 'SETRA SYSTEMS
TEMPTRAK 900MHz PRESSURE DIFFERENTIAL MONTIOR, MODEL
NUMBER: SRPM0R1WBV1E' IN ACCORDANCE WITH THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE VA WILL
PROVIDE PROGRAMMING TO THE TEMPTRAK SYSTEM SO THAT IT IS
OPERATIONAL BEFORE ANY NEW WORK BEGINS. PRESSURE
DIFFERENTIAL MONITOR MUST BE OPERATIONAL FOR THE
DURATION OF CONSTRUCTION. COORDINATE INSTALLATION
LOCATION AND WORK PERFORMED BY THE VA WITH THE COR IN
ADVANCE.
BUILDING 133
HEALTHCARE
OCCUPANCY
M G
P M
G V
M G
P M
G V
M G
P M
G V
P
P
P
P
P
P
- MAINTAIN CLASS IV REQUIREMENTS
- INSTALLATION OF PARTITIONS/ BARRIERS TO
OCCUR DURING OFF-HOURS
- ALL 4TH FLOOR WORK TO OCCUR DURING
ONE (21) DAY PERIOD. THIS IS TO INCLUDE
START OF INSTALLATION OF INFECTION
CONTROL BARRIERS (MEASURES), TO REVIEW,
PUNCHLIST, AND CLEANING AND APPROVAL.
- COORDINATE ALL WORK WITH COR.
EXST.
OFFICE
4A-152
EXST.
MED.
STORAGE
4A-153
EXST.
NURSE
STATION
4A-151
EXST. CORR
C4-111
STAIR
NO. 2
EXST. CORR
C4-106
ELEV.
LOBBY
C4-100
STAIR
NO. 1
ELEV.
EL-S09
EXST. CORR
C4-102 EXST.
CORR
C4-101
EXST. ADMIN
AREA
4A-123
EXST.
WAITING
4A-124EXST.
CORR
C4-110A
REMOVE WINDOW(S) FOR NEGATIVE PRESSURE
EXHAUST. TEMPORARILY INFILL OPENING WITH
PLYWOOD AND ADAPTER FOR AIR EXHAUST
AREA OF CONSTRUCTION
AREAS IN THE SCOPE OF WORK OF THIS PROJECT. THESE
AREAS INCLUDE NEW CONSTRUCTION.
AREA OF DISTURBANCE
AREAS THAT WILL BE IMPACTED BY THE BASE BID OF WORK
OF THIS PROJECT. THESE AREAS INCLUDE BUT ARE NOT
LIMITED TO AREAS THAT WILL BE SHUT DOWN, ACCESSED,
OR DISRUPTED DURING CONSTRUCTION.
ELEVATOR AND STAIR FOR CONSTRUCTION WASTE
ELEVATOR AND STAIR DESIGNATED FOR TRANSPORTATION
OF CONSTRUCTION WASTE.
CONSTRUCTION OFFICE:
AREA DESIGNATED AS THE CONSTRUCTION OFFICE.
A Serv ic e
D is ab l e d Ve t e ran Owned Sma ll Bus iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NORTH
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
BLDG. 133
Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER. INFECTION CONTROL PLAN
R-4 01/18/19
JAMES A. LOVELL FEDERAL HEALTH
CENTER-NORTH CHICAGO, ILLINOIS
REF HQR
3/32" = 1'-0"F1 FLOOR 4 INFECTION CONTROL PLAN
SHEET NOTES
LEGEND
1. COORDINATE INFECTION CONTROL PROCEDURES WITH THE
VA/FHCC INFECTION CONTROL MANAGER.
2. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING TEMPORARY
CONTAINMENT PARTITIONS AND TEMPORARY VENTILATION SYSTEMS
REQUIRED TO PREVENT SPREAD OF DUST FROM CONSTRUCTION
AREA TO OCCUPIED AREAS OF THE BUILDING. SEE MECHANICAL
PLANS FOR ADDITIONAL INFORMATION. OCCUPIED AREAS SHALL
REMAIN DUST FREE THROUGHOUT CONSTRUCTION.
3. THE CONTRACTOR SHALL MAINTAIN THE AFFECTED AREAS OF THIS
BUILDING (INCLUDE MATERIAL TRANSPORT ROUTES) CLEAN AND
DUST SURFACES. THE CONTRACTOR SHALL COORDINATE WITH THE
INFECTION CONTROL STAFF PRIOR TO THE START OF
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COMPLIANCE WITH ALL INFECTION CONTROL RECOMMENDATIONS
AND REQUIREMENTS.
4. THE FACILITY WILL REMAIN OCCUPIED THROUGHOUT THE
CONSTRUCTION PERIOD. THE CONTRACTOR SHALL TAKE EVERY
PRECAUTION TO ENSURE THE UNINTERRUPTED OPERATION OF THE
FACILITY, STAFF, PATIENTS, AND VISITORS. THE CONTRACTOR SHALL
COORDINATE ALL WORK, CONSTRUCTION, PATHWAYS, ELEVATORS
USAGE, AND UTILITY INTERRUPTION WITH FHCC/VA, PM, AND/OR
FACILITIES DIRECTOR.
5. THE CONTRACTOR SHALL MAINTAIN THE REQUIREMENTS OF A
CLASS IV SYSTEM INFECTION CONTROL SYSTEM AS DEFINED IN
SPECIFICATION SECTION 01 35 26 AND THE ICRA.
6. TEMPORARY PARTITION:
A. THE CONTRACTOR SHALL DETERMINE WHERE TEMPORARY
PARTITIONS ARE REQUIRED TO MEET CLASS IV INFECTIONS
CONTROL REQUIREMENTS, FACILITY OPERATIONS, AND
CONTRACTOR SCHEDULING.
B. CLASS IV IC REQUIRES AN ANTE ROOM.
C. PARTITIONS OUTSIDE THE CONSTRUCTION AREA SHALL BE
STARC SYSTEMS (OR EQUAL) PANEL SYSTEM WITH PRESSURE
MONITOR PORTS AND DATA RECORDING.
7. OFF HOURS ARE DEFINED AS 7:00PM-3:00 AM. MINIMIZE TIME FRAME
TO THE GREATEST EXTENTS POSSIBLE. CONTRACTOR TO
COORDINATE WITH CONSTRUCTION MANAGER PRIOR TO
COMENCEMENT OF AFTER HOURS WORK.
8. TEMPORARY PARTITIONS SHALL BE SMOKE TIGHT CONSTRUCTION
OF GYPSUM BOARD OR OTHER NON-COMBUSTIBLE OR LIMITED-
COMUBSTIBLE MATERIAL. PARTITIONS SHALL BE FULL HEIGHT,
EXTENDING THROUGH SUSPENDED CEILINGS TO THE FLOOR SLAB
OR ROOF DECK ABOVE AND SHALL BE 1-HOUR RATED, UNLESS
SPRINKLERS ARE OPERATIONAL ON BOTH SIDES OF THE
TEMPORARY PARTITION, WHEREUPON THE PARTITIONS MAY BE
PERMITTED TO TERMINATE AT THE CEILING. WHERE THE CEILING ON
ONE SIDE OF THE TEMPORARY CONSTRUCTION BARRIER HAS BEEN
REMOVED, THE TEMPORARY PARTITION MUST EXTEND TO THE DECK
ABOVE AND BE 1-HOUR RATED.
C
B
AA
B
C
SD
SD
SD
SD
S S
S S
S S
M G
P M
G V
SD SD SD
SD
SD
SD
P
P
P
FE
C
S S
5 6 7 8 9 104321
GG
F
E
D
C
B
A
PATH "B"
PATH "A"
PATH "C"
PATH "D"
1167 SF
EXST. CORRIDOR
C3-140
90 SF
POSITIVE ANTE
ROOM
3A-165A
71 SF
POSITIVE BUFFER
ROOM
3A-165B
161 SF
NEGATIVE
BUFFER ROOM
3A-165C
53 SF
RESTROOM
3A-166
EXST
INFUSION
EXST
INFUSION
EXST
INFUSION
EXST
INFUSION
EXST
NOURISHMENT
EXST
INFUSION
EXST
INFUSION
EXST
MEDS
EXST INFUSION/
PROCEDURE
EXST
TOILET
EXST
INFUSION
EXST
ELEC.
EXST
TOILET
EXST
SPSEXST
SOILEDEXST
INTAKE
EXST
CARE
PLANNING
EXST
TOILET
EXST
TOILET
EXST
EXAM
EXST
EXAM
EXST
EXAM
EXST
EXAM
EXST MD
OFFICE
EXST
LOUNGE
EXST
OFFICE
EXST
TOILET
EXST
NURSE
OFFICE
EXST
PHARM.
OFFICE
EXST
RESIDENT
OFFICE
EXST
TOILET EXST
WAITING
EXST
CLEAN
EXST
FILING EXST
RECEPTION
EXST
OFFICE
EXST
JAN
EXST
TOILET
EXST
PATIENT
BEDRM.
EXST
NURSE
OFFICE
EXST
WAITING
99 SF
PHARMACY
RECEIVING AND
SUPPLY
3A-165
EXST
PATIENT
BEDRM
EXST
TOILET
AED
3A-1323A-133
3A-128A
3A-135
3A-134
3A-131
3A-137
3A-138
3A-139A
3A-139B
3A-139C
3A-139D3A-139E
3A-139F
3A-130
3A-141
3A-142
3A-143
3A-144
3A-145 3A-146
3A-147 3A-1483A-1493A-1503A-1513A-1523A-1533A-154
3A-155 3A-156 3A-157 3A-158 3A-159 3A-160
3A-161 3A-162 3A-162
3A-164A
3A-163
3A-156 3A-167
3A-167A
PROPOSED PHARMACY
SUITE - 470 SF
SMOKE ZONE INCREASED IN AREA
DUE TO PROPOSED PHARMACY SUITE.
ZONE AREA IS NOW 6737 SF
5 6 7 8 9 10
GG
F
E
D
C
B
A
PATH "E"
PATH "F"
PATH "G"
PATH "H"
185 SF
EXST. OFFICE
4A-152
148 SF
EXST. MEDICAL
EQUIPMENT
STORAGE
4A-153
EXST
PATIENT
RM
EXST
PATIENT
TLT
EXST
PATIENT
RM
EXST
PATIENT
RM
EXST
SOILED
EXST
CLEAN
EXST
PATIENT
RM
EXST
PATIENT
TLT
EXST
PATIENT
RM
EXST
PATIENT
RM
EXST
PATIENT
TLT
EXST
PATIENT
RM
EXST
PATIENT
TLT
EXST
PHYS.
CHART
EXST
MEDS
EXST
NOURISH
EXST
NURSE
STATION
EXST
PATIENT TLT
EXST
STAFF TLT
EXST
PATIENT
RM
EXST
PATIENT
RM
EXST
PATIENT
TLT
EXST
INFUSION
EXST
PATIENT
RM
EXST
PATIENT TLT
EXST
CLEAN
LINEN
EXST
ELEC.
EXST
ANTE RM
EXST
PATIENT
RM
EXST
PATIENT
TLT
EXST
PATIENT
RM
EXST
PATIENT
TLT
EXST
CHART RM
EXST
PATIENT
RM
EXST
PATIENT TLT
EXST
PATIENT
RM
EXST
PATIENT
RM
EXST
PATIENT TLT
EXST
PATIENT
TLT
EXST
PATIENT
RM
EXST
PATIENT
TLT
EXST
PATIENT
TLT
EXST
PATIENT TLT
EXST
PATIENT
TLT
4A-155A
4A-155B
4A-154 4A-151
4A-151A
4A-150
4A-149
4A-148A
4A-148 4A-147A4A-1474A-146
4A-146A4A-145A4A-145
4A-144 4A-144A 4A-143A 4A-143 4A-142
4A-142A 4A-141A 4A-141 4A-137 4A-139
4A-136
4A-135A
4A-135
4A-135B
4A-134
4A-134A
4A-134
4A-132
4A-132A
4A-131A
4A-131
4A-130
4A-130A
4A-127A 4A-127 4A-126A
4A-126
EXISTING SMOKE ZONE PERIMETER WALL IS AFFECTED
BY PROPOSED CONSTRUCTION AND MUST BE MAINTAINED
WITH A MINIMUM OF 1-HOUR FIRE/ SMOKE WALL
V A
PATH OF TRAVEL (FEET)
PRIVATE MODE VOICE/ALARM SYSTEM THROUGHOUT
(COORDINATE W/ ELECTRICAL)
EXIT FLOW
START OF TRAVEL
EXIT SIGN
(COORDINATE W/ ELECTRICAL)
PORTABLE FIRE EXTINGUISHER
(COORDINATE W/ FIRE MARSHAL)
SUITE SEPARATION WALL
SMOKE RESISTIVE HAZARDOUS AREA
TWO HOUR FIRE WALL CONSTRUCTION
AED AUTOMATIC ELECTRICAL DEFIBRILLATOR
ONE HOUR FIRE/ SMOKE WALL
A Serv ic e
D is ab l e d Ve t e ran Owned Sma ll Bus iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NORTH
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
BLDG. 133
Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER. LIFE SAFETY SHEET
G-001 01/18/19
JAMES A. LOVELL FEDERAL HEALTH
CENTER-NORTH CHICAGO, ILLINOIS
REF HQR
LEVEL 3 LEVEL 4LEVEL 2
3/32" = 1'-0"C1 LEVEL 3 LIFE SAFETY PLAN
3/32" = 1'-0"F1 LEVEL 4 LIFE SAFETY PLAN
Path ID Common Path
Distance Allowable Common
Path Actual Travel
Distance Allowable Travel
Distance A 48' - 10" 100' - 0" 48' - 10" 200' - 0" B 44' - 5" 100' - 0" 44' - 5" 200' - 0" C 44' - 5" 100' - 0" 172' - 8" 200' - 0" D 0' - 0" 100' - 0" 137' - 10" 200' - 0" E 28' - 9" 100' - 0" 28' - 9" 200' - 0" F 27' - 6" 100' - 0" 27' - 6" 200' - 0" G 27' - 6" 100' - 0" 167' - 4" 200' - 0" H 28' - 9" 100' - 0" 116' - 1" 200' - 0"
GENERAL SHEET NOTES
LIFE SAFETY LEGEND
EXIT ACCESS TRAVEL DISTANCE
1. THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE
SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND SHALL
PROVIDE A CLEAR WIDTH OF NOT LESS THAN 32 INCHES. THE
HEIGHT OF DOORS SHALL NOT BE LESS THAN 80 INCHES.
2. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS
SIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR
EFFORT. ALL EGRESS DOORS TO HAVE PANIC HARDWARE. PANIC
HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR
TWISTING OF THE WRIST. FORCE REQUIRED TO ACTIVATE
OPERABLE PARTS SHALL BE 5 POUNDS.
3. THE MEANS OF EGRESS, AND EXIT DISCHARGE, SHALL BE
ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED WITH A LIGHT
INTENSITY OF NOT LESS THAN 1 FOOT-CANDLE AT THE WALKING
SURFACE LEVEL.
4. THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF ALL
OBSTRUCTIONS AT ALL TIMES. NO STORAGE IS PERMITTED IN ANY
EGRESS PATHS.
5. ALL NEW PROPOSED FIRE EXTINGUISHER LOCATIONS ARE
DETERMINED BY IFC TABLE 906.3(1), NFPA 10, AND/OR BY THE
DIRECTION OF THE LOCAL AUTHORITY.
6. THE INFORMATION CONTAINED IN THESE LIFE SAFETY PLANS
(SHEET) ARE IN REFERENCE TO THE PROJECT SCOPE OF WORK
(PROJECT LIMIT LINE) CONTAINED IN THE ARCHITECTURAL PLANS
(ONLY). A COMPLETE LIFE SAFETY REVIEW OF THE FACILITY WAS
NOT COMPLETED AS PART OF THIS SCOPE OF WORK. AREAS
OUTSIDE OF THE SCOPE OF WORK (PROJECT LIMIT LINE) OF THESE
DOCUMENTS WERE PROVIDED BY FHCC FOR REFERENCE BY THE
DESIGN TEAM AND ARE ASSUMED TO BE ACCURATE AND COMPLETE
FOR USE IN THESE CONSTRICTION DOCUMENTS. COORDINATE WITH
FHCC FOR ANY ADDITIONAL LIFE SAFETY INFORMATION OUTSIDE OF
THIS SCOPE OF WORK.
PROJECT SUMMARY:
THIS PROJECT CONSISTS OF AN ONCOLOGY RENOVATION OF THE THIRD AND FOURTH FLOORS, BUILDING 133. WITH WORK TO SUPPORT THE RENOVATION ON THE SECOND FLOOR, MECHANICAL PENTHOUSE, AND ROOF. THIS PROJECT IS TO INCORPORATE INTERIOR FINISHES AND COLORS, SIGNAGE AND WAYFINDING AND NEW MEDICAL EQUIPMENT SELECTION WITH ENGINEER. THE PROPOSED PHARMACY IS CONSIDERED A NON-INPATIENT SUITE. THE
CONSTRUCTION SCOPE SHALL INCLUDE COMPLIANCE WITH THE SUITE REQUIREMENTS BELOW.
APPLICABLE CODES
INTERNATIIONAL BUILDING CODE (IBC)(ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS)
NFPA 101 LIFE SAFETY CODE 2018 EDITION
VA FIRE PROTECTION DESIGN GUIDE 7TH EDITION
NFPA NATIONAL FIRE CODE (EXCEPTION OF NFPA 5000 AND NFPA 900)
USP 797
USP 800
VA SEISMIC DESIGN REQUIREMENTS, H-18-8
NATIONAL ELECTRICAL CODE (NEC)
INTERNATIONAL PLUMBING CODE (IPC)
ENERGY POLICY ACT OF 2005 (EPACT)
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU) EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND TRANSPORTATION MANAGEMENT
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGN
VENTILATION FOR ACCEPTABE INDOOR AIR QUALITY - ASHRAE STANDARD 62.1 -2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE STANDARD 15-2007
OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS)
GENERAL SUITE REQUIREMENTS
• SUITES MUST BE SEPARATED FROM THE REST OF THE BUILDING AND OTHER SUITES BY WALLS AND DOORS BUILT TO AT LEAST THE
SAME REQUIREMENTS AS THE CORRIDOR (CHAPTER 18 - 19.2.5.7.1.2)
• INTERVENING ROOMS MUST NOT BE HAZARDOUS AREAS (CHAPTER 18 - 19.2.5.7.1.3A)
• HAZARDOUS ROOMS MUST BE ENCLOSE PER 19.3.2.1 (CHAPTER 18 - 19.2.5.7.1.3B)
• MULTIPLE CONTIGUOUS HAZARDOUS SPACES WITHIN A SUITE DO NOT NEED TO BE INDIVIDUALLY ENCLOSED WITHIN RATED WALLS, PROVIDED THE SUITE IS PRIMARILY A HAZARDOUS AREA AND THE PERIMETER OF THE SUITE IS CONSTRUCTED PER 19.3.2.1
(CHAPTER18 - 19.2.5.7.1.3C)
• EXISTING STERILE STORAGE AREAS, WITH ONLY A SINGLE DAY SUPPLY, WITHIN A SPRINKLED OPERATING ROOM SUITE DO NOT NEED
TO BE ENCLOSED AS A HAZARDOUS SPACE (CHAPTER 18 - 19.2.5.7.1.3D
• SUBDIVISION WALLS WITHIN A SUITE MUST BE MADE WITHIN NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS OR WITH FIRE- RETARDANT WOOD THAT IS ENCAPSULATED BEHIND DRYWALL OR PLASTER (CHAPTER 18 - 19.2.5.7.1.4)
• THERE ARE NO SPECIFIC MINIMUM SUITE AISLE/ HALL/ PASSAGE WIDTH AND CORRIDOR WIDTHS O NOT APPLY (7.3.4.1.2)
• PER NFPA 101, THE PHARMACY COMPOUNDING AREA CAN BE CLASSIFIED AS A SUITE FOR PURPOSED OF EGRESS AND LIFE SAFETY
REQUIREMENTS. SUITES ARE COVERED IN CHAPTERS 18.2.5.7 AND 19.2.5.7.
TRAVEL DISTANCE AND COMMON PATH OF TRAVEL (CHAPTER 19):
HEALTH CARE (EXISTING): MAX TRAVEL DISTANCE MAX COMMON PATH OF TRAVEL
SPRINKLED = 200' - 0" SPRINKLED = NR
UNSPRINKLED = 150' - 0" UNSPRINKLED = NR
BUSINESS (CHAPTER 38): MAX TRAVEL DISTANCE MAX COMMON PATH OF TRAVEL
SPRINKLED = 300' - 0" SPRINKLED = 100' - 0"
UNSPRINKLED = 200' - 0" UNSPRINKLED = 75' - 0"
*NON-(IN) PATIENT SUITES MUST FOLLOW COMMON PATH OF TRAVEL EGRESS LIMIT OF THE PRIMARY USE AND OCCUPANCY OF THE SPACE
(CHAPTER 18 - 19.2.5.7.4)(PHARMACY = BUSINESS)
*PASSAGES/ HALLS IN A SUITE SHALL NOT BE LESS THAN 36", NO DOOR LATCHING REQUIREMENTS, NO DOOR SWING REQUIREMENTS AND
NO DOOR CLOSING REQUIREMENTS (7.3.4.1)
CORRIDOR WALL/ DOOR REQUIREMENTS (18.2.5.7.1.2):
• SUITES SHALL BE SEPARATED FROM THE REMAINDER OF THE BUILDING AND FROM OTHER SUITES, BY WALLS AND DOORS MEETING
CORRIDOR WALL/ DOOR REQUIREMENTS.
INTERIOR WALLS (18.2.5.7.1.2):
• NONCOMBUSTIBLE PARTITIONS (4.6.13)
• LIMITED-COMBUSTIBLE PARTITIONS (4.6.14)
1. PARTITIONS CONSTRUCTED WITH FIRE-RETARDANT, TREATED WOOD ENCLOSED WITH NONCOMBUSTIBLE OR LIMITED-
COMBUSTIBLE MATERIALS
2. SUCH PARTITIONS SHALL NOT BE REQUIRED TO BE FIRE RATED
EXIT ACCESS:
• CORRIDOR EXIT ACCESS - MINIMUM OF (1) (18/19.2.5.6.1)
• CORRIDOR EXIT ACCESS - MINIMUM OF (2) IF GREATER THAN 2,500SF. SECOND CAN BE TO CORRIDOR, STAIR, EXTERIOR OR SUITE
(18/19.2.5.5.2)
• THE EGRESS EXCEPTION FOR SUITES IS IN NFPA 101 - 18/19.2.5.6.4
HAZARDOUS CLASSIFICATION
SUITES CONTAINING HAZARDOUS SPACES (18.2.5.7.1.3):
• INTERVENING ROOMS SHALL NOT BE HAZARDOUS AREAS AS DEFINED BY (18.3.2)
• HAZARDOUS AREAS WITHIN A SUITE SHALL BE SEPARATED FROM THE REMAINDER OF THE SUITE IN ACCORDANCE WITH 18.3.2.1, UNLESS OTHERWISE PROVIDED IN 18.2.5.7.1.3C
• HAZARDOUS AREAS WITHIN A SUITE SHALL NOT BE REQUIRED TO BE SEPARATED FROM THE REMAINDER OF THE SUITE IF:
1. SUITE IS PRIMARILY A HAZARDOUS AREA
2. SUITE HAS APPROVED AUTOMATIC SMOKE DETECTION
3. SUITE IS ENCLOSED AS A HAZARDOUS AREA
*THE CLASSIFICATION OF "HAZARDOUS" IN THE NFPA 101 DIFFERS FROM USP 800. ROOMS LABELED "HAZARDOUS" IN THE CONSTRUCTION DOCUMENTS REFER TO USP 800 REQUIREMENTS. "HAZARDOUS" REGARDING USP 800 RELATES TO THE TYPE OF DRUGS COMPOUNDED IN
THE PHARMACY AND NOT THE COMBUSTIBILITY OF THE MATERIALS IN THE PHARMACY.
GENERAL SHEET NOTES
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
NR
F+G E+H
B+C A+D
EXISTING CONSTRUCTION TO BE
DEMOLISHED
EXISTING CONSTRUCTION TO
REMAIN
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE REMOVED
(DEMO)
1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT"
UNLESS OTHERWISE NOTED ON PLAN.
2. REFER TO MEP SHEETS FOR ADDITIONAL DEMOLITION SCOPE AND
REQUIREMENTS.
3. THE DEMOLITION PLANS ARE DERIVED FROM EXISTING BUILDING
PLANS AND ARE INTENDED TO REASONABLY REPRESENT EXISTING
AND CURRENT CONDITIONS. ALL DIMENSIONS AND INFORMATION IN
THESE DRAWINGS ARE BASED, IN PART, ON THAT FACT. ACTUAL
CONDITIONS MAY VARY FROM THAT SHOWN. NOTIFY THE ARCHITECT
IMMEDIATELY FOR REVIEW SHOULD ANY DISCREPANCIES WHICH
SIGNIFICANTLY AFFECT THE DEMOLITION OR NEW CONSTRUCTION
WORK OCCUR.
4. CONTRACTOR TO VERIFY EXISTING CONDITIONS IN THE FIELD.
5. REMOVE ALL WALL MOUNTED ACCESSORIES AND WIRE MOLD
COMPLETE. SALVAGE ACCESSORIES FOR POSSIBLE REUSE.
6. ALL PARTITIONS INDICATED FOR REMOVAL SHALL BE REMOVED TO
THE UNDERSIDE OF STRUCTURE ABOVE, UNLESS NOTED
OTHERWISE.
7. ALL FOURTH FLOOR WORK (ALL TRADES) TO OCCUR DURING ONE
MAXIMUM 21 CALENDAR DARY PERIOD. COORDINATE WORK WITH
COR. SEE R SHEETS FOR ADDITIONAL INFORMATION
8. TEMPORARY PARTITIONS SHALL BE SMOKE TIGHT CONSTRUCTION
OF GYPSUM BOARD OR OTHER NON-COMBUSTIBLE OR LIMITED-
COMUBSTIBLE MATERIAL. PARTITIONS SHALL BE FULL HEIGHT,
EXTENDING THROUGH SUSPENDED CEILINGS TO THE FLOOR SLAB
OR ROOF DECK ABOVE AND SHALL BE 1-HOUR RATED, UNLESS
SPRINKLERS ARE OPERATIONAL ON BOTH SIDES OF THE
TEMPORARY PARTITION, WHEREUPON THE PARTITIONS MAY BE
PERMITTED TO TERMINATE AT THE CEILING. WHERE THE CEILING ON
ONE SIDE OF THE TEMPORARY CONSTRUCTION BARRIER HAS BEEN
REMOVED, THE TEMPORARY PARTITION MUST EXTEND TO THE DECK
ABOVE AND BE 1-HOUR RATED.
8 9 10
G
F
E
PROJECT LIMIT LINE
X-VCT X-VCT
1 1
12 12
4" 3' - 4"
1' - 10 3/4" 3' - 4"
190 SF
EXST. PATIENT
BEDROOM
3A-167
56 SF
EXST. RESTROOM
3A-167A
195 SF
EXST. RECEPTION
3A-164
EXST. CORRIDOR
3C-139
EXISTING PATIENT
ROOM
EXISTING COMPOUNDING
ROOM
3 3 18
3A-165 3A-166 (EXST.)
EXST.
RESTROOM
3A-166A (EXST.)
8 9 10
G
F
E
X-ACT
8' - 7"A.F.F.
X-ACT
9' - 0"A.F.F.
PROJECT LIMIT LINE
CLG-1
9' - 0"A.F.F.
13 13 13
EXIST. RECEPTION
EXISTING PATIENT ROOM
EXISTING COMPOUNDING
ROOM
EXIST.
RESTROOM
EXIST. CORR.
EXIST. RESTROOM
EXIST. PATIENT BEDROOM
9 10
G
F
E
X-GYP-EXIST
9' - 0"A.F.F.
CLG-1
9' - 0"A.F.F.
COORD. WITH STRUCTURAL
1' - 0" +/-
6"
PROJECT LIMIT LINE
EXIST. CORR.
185 SF
EXST. OFFICE
4A-152
148 SF
EXST. MEDICAL
EQUIPMENT
STORAGE
4A-153
52 SF
EXST. PATIENT
TOILET
4A-155B
51 SF
EXST. STAFF
TOILET
4A-154
EXIST. HAC
4A-155A
9 10
G
F F
E
PROJECT LIMIT LINE
EXIST. CORR.
185 SF
EXST. OFFICE
4A-152
148 SF
EXST. MEDICAL
EQUIPMENT
STORAGE
4A-153
52 SF
EXST. PATIENT
TOILET
4A-155B
51 SF
EXST. STAFF
TOILET
4A-154
EXIST. HAC
4A-155A
SHEET NOTES
LEGEND
# NOTE
1 REMOVE EXISTING FLOORING AND WALL BASE IN ITS ENTIRETY. PREP SUBFLOOR TO RECEIVE
NEW FLOOR FINISH. LEVEL FLOOR AS REQUIRED.
3 MAINTAIN FIRE/SMOKE RATING OF EXISTING WALLS THROUGHOUT CONSTRUCTION.
4 REMOVE CEILING TILE, CEILING GRID, SUSPENSION SYSTEM, AND CEILING COMPONENTS IN ITS
ENTIRETY. REFER TO MEPFP DRAWINGS FOR ADDITIONAL INFORMATION.
6 REMOVE EXISTING DOOR AND FRAME IN ITS ENTIRETY. IN FILL OPENING WITH CONSTRUCTION
TO MATCH THE EXISTING WALL CONSTRUCTION. PREP WALLS TO RECIEVE NEW FINISH.
7 REMOVE EXISTING WALL IN ITS ENTIRETY. PATCH AND REPAIR SURFACES TO MATCH ADJACENT
FINISHES.
8 RELOCATE EXISTING EYE WASH STATION. REFER TO MEP DRAWINGS FOR ADDITIONAL
INFORMATION.
9 REMOVE EXISTING HEADWALL IN ITS ENTIRETY. REFER TO MEP DRAWINGS FOR ADDITIONAL
INFORMATION, INCLUDING BUT NOT LIMITED TO MEDICAL GAS REMOVAL
11 REMOVE EXISTING WALL COVERING. PATCH AND PREP WALLS TO RECEIVE NEW FINISHES.
12 WARDROBE CABINET TO BE REMOVED IN ITS ENTIRETY.
13 EXISTING CEILING LED LIGHT FIXTURES TO BE REMOVED AND TURNED OVER TO FHCC.
14 REMOVE EXISTING SINK IN ITS ENTIRETY. REFER TO MEP DRAWINGS FOR ADDITIONAL
INFORMATION.
15 REMOVE EXISTING BEDRAIL IN ITS ENTIRETY.
16 REMOVE EXISTING WALL FINISH IN ITS ENTIRETY. PATCH AND PREP WALLS FOR NEW FINISHES.
17 REMOVE EXISTING WALL IN ITS ENTIRETY. REMOVE OR RELOCATE ANY EXISTING UTILITIES
INCLUDING BUT NOT LIMITED TO ELECTRICAL CONDUITS AND PLUMBING PIPING IN THE WALLS
REQUIRED. REFER TO MEPFP DRAWINGS FOR ADDITIONAL INFORMATION. PATCH AND REPAIR
ADJACENT SURFACES AS REQUIRED. COORDINATE AND MINIMIZE ANY OUTAGE WITH COR.
18 REMOVE PORTION OF EXISTING WALL TO ACCOMODATE NEW DOOR AND FRAME. PATCH AND
REPAIR WALL AS REQUIRED. PREP WALLS TO RECEIVE NEW WALL FINISH.
19 PATCH AND PREP WALLS AS REQUIRED TO RECEIVE NEW FINISHES.
20 REMOVE PORTION OF EXISTING FLOOR SLAB TO ACCOMODATE NEW DUCTWORK. REFER TO MEP
AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.
21 EXISTING CEILING FINISH TO REMAIN.
22 REMOVE PORTION OF EXISTING GYP. CEILING TO ACCOMODATE NEW DUCTWORK. REFER TO
MEP AND STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.
23 REMOVE EXISITNG EXHAUST DUCT AND CHASE. COORDINATE WITH MECHANICAL AND
STRUCTURAL DRAWINGS FOR ADDITIONAL REMOVAL AND INFILL INFORMATION. PATCH AND
REPAIR AFFECTED FINISHES TO MATCH EXISTING ADJACENT SURFACES.
KEYNOTES
A Serv ic e
D is ab l e d Ve t e ran Owned Sma ll Bus iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NORTH
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
BLDG. 133
Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER. DEMOLITION PLANS
AD-100
01/18/19
JAMES A. LOVELL FEDERAL HEALTH
CENTER-NORTH CHICAGO, ILLINOIS
REF HQR
1/4" = 1'-0"C1 FLOOR 3 DEMOLITION FLOOR PLAN
1/4" = 1'-0"F1 FLOOR 3 DEMOLITION RCP
1/4" = 1'-0"E6 FLOOR 4 DEMOLITION RCP LEVEL 3 LEVEL 4LEVEL 2
1/4" = 1'-0"C6 FLOOR 4 DEMOLITION FLOOR PLAN
SS
S S
S S
S S
S S
S S
S S
S S
S S
S S
PARTIAL HT PARTITION - SEE
ELEVATION FOR HEIGHT
NEW PARTITION
EXISTING CONSTRUCTION TO REMAIN
RATED PARTITION
EXISTING DOOR
NEW CONSTRUCTION DOOR
SUITE PERIMETER PARTITION
8 9 10
G
F
E
5-
A
165A-A
5C
-A
165B-A
A-200
B2
A-200
B3
A-200B5
A 1 a
A 1 a
A 1 a
A 1 a
D 4 aD 4 a
E 4 e
99 SF
PHARMACY
RECEIVING AND
SUPPLY
3A-165
90 SF
POSITIVE ANTE
ROOM
3A-165A 71 SF
POSITIVE BUFFER
ROOM
3A-165B
161 SF
NEGATIVE
BUFFER ROOM
3A-165C
EPY-1
EPY-1
EPY-1
EPY-1
PROJECT LIMIT LINE
53 SF
RESTROOM
3A-166
B1 131131
EXIST
6-
A
LINE INDICATES
LOCATION OF PROPOSED
PHARMACY SUITE
A-500 E9
195 SF
EXST. RECEPTION
3A-164
190 SF
EXST. PATIENT
BEDROOM
3A-167
56 SF
EXST. RESTROOM
3A-167A
E 4 e 118 118E 4 e
E9
A-500
A-500 E9
A-500 E9
SIGN 99.1 & 99.a
SIGN 69.1
SIGN
69.1
SIGN
69.1
SIGN 99.6
8 9 10
G
F
E
99 SF
PHARMACY
RECEIVING AND
SUPPLY
3A-165
90 SF
POSITIVE ANTE
ROOM
3A-165A
71 SF
POSITIVE BUFFER
ROOM
3A-165B
161 SF
NEGATIVE
BUFFER ROOM
3A-165C
6' - 7 1/4" 4' - 6" 18' - 4 3/4"
1' - 10 3/4" 3' - 4" R.O. 1' - 4 1/2"
7'
- 9
4"
3'
- 4
R.
O.
4'
- 0 1/
2"
6' - 11 1/2" 12' - 10" 9' - 8 1/2"
6' - 0 1/2" 3' - 4" R.O. 3' - 1 1/4" 5" 9' - 7 3/4"
5" 3'
- 4
R.
O.
3'
- 9
6' - 3 3/4" +/-
4' - 1" 5' - 11 3/4"
3'
- 4
1'
- 5
PROJECT LIMIT LINE
53 SF
RESTROOM
3A-166
4" 3' - 4" R.O.
EJ 56 SF
EXST. RESTROOM
3A-167A
190 SF
EXST. PATIENT
BEDROOM
3A-167
195 SF
EXST. RECEPTION
3A-164
C L
1'
- 7
CL
4' - 6" CL
EJ
1'
- 6
1. ALL SHADED AREAS INDICATE "NO WORK" OR "NOT IN CONTRACT" UNLESS
OTHERWISE NOTED ON PLAN.
2. ALL DIMENSIONS ARE TO FACE OF STUD OR BLOCK FACE.
3. PATCH AND REPAIR REMAINING SURFACES AS NEEDED DUE TO THE
DEMOLITION OR THE REMOVAL OF CONSTRUCTION. PARTITIONS AND
CONSTRUCTION THAT IS TO REMAIN AND IS ADJACENT TO CONSTRUCTION OR
EQUIPMENT TO BE DEMOLISHED SHALL BE REPAIRED TO BE LIKE NEW
APPEARANCE. FINISH SURFACES ARE TO BE SMOOTH AND FLUSH WITH
ADJACENT SURFACES AND PREPPED FOR NEW FINISH.
4. VERIFY THAT ALL BUILDING CORE PARTITIONS AND COLUMNS SHOWN AS
EXISTING CONSTRUCTION ARE READY TO RECEIVE NEW FINISHES AS
SPECIFIED. IF NOT, PROVIDE DRYWALL FINISH AS REQUIRED. DRYWALL
THICKNESS TO MATCH BUILDING STANDARD NOTED ON PARTITION TYPES. AT
ALL EXISTING GYPSUM BOARD CORNERS, VERIFY THAT ALL CORNER BEADS ARE
STRAIGHT, UNBROKEN AND NOT DAMAGED. PROVIDE NEW CORNER BEADS AS
REQUIRED.
5. ALL ANGLES SHALL BE 90 DEGREES UNLESS OTHERWISE NOTED ON PLAN.
6. ALL OPENINGS TO BE 3'-0" WIDE CLEAR UNLESS OTHERWISE DIMENSIONED ON
PLAN. BULKHEAD TO ALIGN
7. PROVIDE [3/8" (IF INTERIOR) / 1/2” (IF EXTERIOR)] CLEAR TEMPERED GLASS,
TYPICAL UNLESS OTHERWISE NOTED. SEE PLAN OR ELEVATIONS FOR SPECIFIC
GLASS DIMENSIONS. ANY JOINTS IN GLASS TO BE POLISHED EDGE, BUTT
GLAZED, NO SEALANT. 1/16" MAXIMUM HORIZONTAL DIMENSION BETWEEN
ADJACENT PANELS, TYPICAL.
8. GENERAL CONTRACTOR TO COORDINATE FIRE EXTINGUISHER LOCATIONS
WITH CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION. FIRE
EXTINGUISHERS ARE TO BE MOUNTED TO MEET ADA STANDARDS.
9. GENERAL CONTRACTOR TO COORDINATE ALL HORN STROBE AND/OR FIRE
ALARM PULL STATION LOCATIONS WITH CONSTRUCTION MANAGER PRIOR TO
CONSTRUCTION.
10. PIPES AND COLUMN FURRING SHALL BE HELD AS CLOSE TO THE PIPING AND/OR
COLUMNS AS POSSIBLE (U.N.O.)
11. OPENINGS THROUGH EXISTING FLOOR SLABS SHALL BE SAW CUT OR CORE
DRILLED. SUCH OPENINGS WILL BE LOCATED TO MINIMIZE THE SIZE
REQUIREMENTS FOR THE FURRED CHASES. THE CONTRACTOR WILL LOCATE
ALL FLOOR OPENINGS IN THE FIELD AND REVIEW PROPOSED LOCATIONS WITH
THE OWNER AND ARCHITECT PRIOR TO BEGINNING WORK.
12. PROVIDE NEW FINISHES AS REQUIRED WHERE DEMOLITION/NEW
CONSTRUCTION IS TAKING PLACE AT BUILDING CORRIDOR TO MATCH EXISTING
CORRIDOR FINISHES.
13. CONTRACTOR TO COORDINATE AND INSTALL FIRE RETARDANT WOOD
BLOCKING AT ALL BUT NOT LIMITED TO THE FOLLOWING LOCATIONS - ALL
FIXTURES, EQUIPMENT, SIGNAGE, MILLWORK.
14. IF ANY FIRE RATED PARTITION FALLS DIRECTLY BENEATH AND PARALLEL TO A
FLOOR JOIST OR BEAM, NOTIFY THE ARCHITECT PRIOR TO FRAMING THE
PARTITION.
15. ALL SWITCHES TO BE MOUNTED NO HIGHER THAN 48" A.F.F. TO MEET ADA
STANDARDS.
16. MOUNT THERMOSTATS 48" A.F.F. MAXIMUM TO MEET ADA STANDARDS.
17. PROVIDE 3" TALL HELVETICA LETTERS STENCILED AT ALL RATED WALLS,
STENCILING TO READ AS FOLLOWS "FIRE AND SMOKE BARRIER-PROTECT ALL
OPENINGS". INCLUDE UL NUMBERS TYPICAL OF ALL RATED WALLS.
18. A.T.P. INDICATES ADA TRAP PROTECTION, PROVIDE ON ALL EXPOSED
SINK/LAVATORY TRAPS.
19. PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BACK-UP PLATES AND
SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL CASEWORK,
TOILET ACCESSORIES AND OF ALL FLOOR-MOUNTED OR SUSPENDED
MECHANICAL AND ELECTRICAL EQUIPMENT.
20. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR EXAMINING AND
CONFIRMING ALL SUBSTRATE CONDITIONS WHERE NEW MATERIALS ARE
APPLIED. SUBSTRATE SHALL BE SMOOTH, FREE OF DEFECTS AND SHALL
CONFORM TO THE REQUIREMENTS OF THE FINISHED MATERIAL
MANUFACTURERS’ RECOMMENDATIONS.
21. WHERE ADJOINING ROOMS HAVE DIFFERENT TYPES OF FLOORING OR SIMILAR
FLOORING OF DIFFERENT COLORS, MAKE TRANSITION UNDER CENTER LINE OF
DOOR.
22. WHERE INDICATED TO MATCH EXISTING FINISH, NEW FINISH TO MATCH IN
MANUFACTURER, PRODUCT, COLOR, STYLE, SIZE AND ALL OTHER ATTRIBUTES.
23. ALL CAULK AT CASEWORK AND COUNTER TOPS TO BE CLEAR. PROVIDE
CAULKING AT ALL FIXTURES.
24. TEMPORARY PARTITIONS SHALL BE SMOKE TIGHT CONSTRUCTION
OF GYPSUM BOARD OR OTHER NON-COMBUSTIBLE OR LIMITED-
COMUBSTIBLE MATERIAL. PARTITIONS SHALL BE FULL HEIGHT,
EXTENDING THROUGH SUSPENDED CEILINGS TO THE FLOOR SLAB
OR ROOF DECK ABOVE AND SHALL BE 1-HOUR RATED, UNLESS
SPRINKLERS ARE OPERATIONAL ON BOTH SIDES OF THE
TEMPORARY PARTITION, WHEREUPON THE PARTITIONS MAY BE
PERMITTED TO TERMINATE AT THE CEILING. WHERE THE CEILING ON
ONE SIDE OF THE TEMPORARY CONSTRUCTION BARRIER HAS BEEN
REMOVED, THE TEMPORARY PARTITION MUST EXTEND TO THE DECK
ABOVE AND BE 1-HOUR RATED.
25. ALL FOURTH FLOOR WORK, ALL TRADES, TO OCCUR DURING ONE MAXIMUM 21
DAY CALENDAR DAY PERIOD COORDINATION WITH COR.
9 10
G
F
148 SF
EXST. MEDICAL
EQUIPMENT
STORAGE
4A-153
6"
PROJECT LIMIT LINE
SE
E
ST
RU
CT
UR
AL
185 SF
EXST. OFFICE
4A-152
B 4 a
C 1 a 51 SF
EXST. STAFF
TOILET
4A-154
52 SF
EXST. PATIENT
TOILET
4A-155B
SEE STRUCTURAL DRAWINGS
3'
- 9
1/ 4"
- 9 1/2" VIF
SEE STRUCTURAL
B 4 a
D 1 a
8 9 10
G
F
E
PRNT
PPE2
PPE2
HOOD
(1)
99 SF
PHARMACY
RECEIVING AND
SUPPLY
3A-165
90 SF
POSITIVE ANTE
ROOM
3A-165A 71 SF
POSITIVE BUFFER
ROOM
3A-165B
161 SF
NEGATIVE
BUFFER ROOM
3A-165C
PH COMP
REF1
SD
TD
PROJECT LIMIT LINE
CH1
SH1 SH1
SH2
SH2
SH2
PPE TRPPE
CH1 CH1
TR
CH1
TR
53 SF
RESTROOM
3A-166
133 PT
190 SF
EXST. PATIENT
BEDROOM
3A-167
56 SF
EXST. RESTROOM
3A-167A
195 SF
EXST. RECEPTION
3A-164
EXT
REF1
HOOD (3)
HOOD
(2)
1167 SF
EXST. CORRIDOR
C3-140
58 SF
EXST. TOILET
3A-157
155 SF
EXST. NURSE
OFFICE
3A-158
118 SF
PHARMACY
OFFICE
3A-159
104 SF
PHARMACY
OFFICE
3A-160 507 SF
EXST. WAITING
3A-162
25 SF
EXST. STAFF
TOILET
3A-161
128 SF
EXST. EXAM
3A-150
124 SF
EXST. EXAM
3A-151
145 SF
EXST. EXAM
3A-152
134134
PR
OJ
EC
T
LIM
IT
LI
NE
SHEET NOTES
LEGEND
KEYNOTES
# NOTE
116 EXISTING WALL TO BE THE NEW SMOKE AREA BARRIER WALL. EXISTING METAL STUD FRAMING AND GYP. FINISHES EXTEND TO THE DECK. MUD AND TAPE ALL UNTAPED GYP. BD. JOINTS. SEAL
ALL UNSEALED PENETRATIONS AND JOINTS WITH FIRE CAULK AS REQUIRED.
117 RELOCATED GUARDIAN GBF1735DP EYEWASH CABINET. INSTALL PER MANUFACTURERS
SPECIFICATIONS REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
118 BLACK-OUT PANELS MECHANICALLY FASTENED TO EXISTING WINDOW FRAME BEHIND NEW
GYP.FURRING. PANELS TO BE PAINTED 1/2" MIN. FINISH GRADE PLYWOOD. PAINT EXTERIOR
FACE OF PLYWOOD BLACK.
122 EXTEND GYP BOARD FINISH BELOW WINDOW SILL TO EXTERIOR WALL.
123 SHAFT OPENING FOR NEW DUCT WORK. COORDINATE SHAFT OPENING AND LOCATION WITH
STRUCTURAL DRAWINGS. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
124 WALL MOUNTED FIRE EXTINGUISHER. COORDINATE FINAL LOCATION WITH CONSTRUCTION
MANAGER IN FIELD.
125 PACS ACCESS CONTROL. FACILITY STANDARD - LENEL ONGUARD SYSTEM. REX REQUEST TO
EXIT. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION
126 15" X 17" STAINLESS STEEL SCRUB SINK WITH FOOT CONTROLS. SEE PLUMBING DRAWINGS FOR
ADDITIONAL INFORMATION.
127 PROVIDED 24"x24" RATED ACCESS DOOR(S) IN SHAFT WALL AS REQUIRED TO ACCESS DAMPERS
IN THE DUCTWORK. COORDINATE FINAL LOCATION(S) AND SILL HEIGHT WITH MECHANICAL AND
STRUCTURAL DRAWINGS.
131 WALL PROTECTION WP-1. REFER TO ELEVATIONS.
132 WALL INFILL TO MATCH EXISTING CONSTRUCTION.
133 AIRLOCK PASS THROUGH.
134 NEW WALL MOUNTED MONITOR AND BRACKET.
136 ROOM SIGNAGE. REFER TO SPECIFICATIONS FOR ADDITONAL INFORMATION.
137 LOCATION OF FIRE RATED ENCLOSURE. SEAL ALL PENETRATIONS PER SPECIFICATIONS. GC TO
COORDINATE LOCATION OF ENCLOSURE WITH EXISTING PNEUMATIC TUBE (OUTSIDE
ENCLOUSRE) AND DUCT WORK (OUTSIDE ENCLOSURE). RATED WALLS AND ENCLOSURE IS NOT
TO INTERFERE WITH EXISTING RADIANT HEAT PANEL. REFER TO MEPFP DRAWINGS FOR
ADDITIONAL INFORMATION.
138 REPAIR FINISHES AS NEEDED AT REMOVED DUCT CHASE LOCATION
A Serv ic e
D is ab l e d Ve t e ran Owned Sma ll Bus iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0101
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: Office of Construction and Facilities Management o n e e ig h th in ch o n e f o o t
B
A
C
D
E
F th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
KEYPLAN
FOR BID - NOT FOR CONSTRUCTION
FULLY SPRINKLERED
NORTH
ONCOLOGY RENOVATION
FOR USP 800 REQUIREMENTS
556-17-014
BLDG.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.