36C25218B0789-004.pdf
PDF 1 MB Posted
- Attached to
- Repair Site Drainage Bldg 7 Project Number: 695-18-105 Clement J. Zablocki VA Medical Center Milwaukee WI
- Solicitation number
- 36C25218B0789
About this file
36C25218B0789 695-15-105 Firestop J_A.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25218C0180-000.docx | DOCX document | |
| 36C25218B0789-00002000.docx | DOCX document | |
| 36C25218B0789-00002001.pdf | ||
| 36C25218B0789-00001000.docx | DOCX document | |
| 36C25218B0789-001.docx | DOCX document | |
| 36C25218B0789-005.pdf | ||
| 36C25218B0789-002.pdf | ||
| 36C25218B0789-003.pdf | ||
| 36C25218B0789-000.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under $150K
VHAPM Part 813.106 Page 1 of 2 Original Date: 08/30/17
DEPARTMENT OF VETERANS AFFAIRS
Justification for Single Source Awards IAW FAR 13.106‐1 For
Over Micro‐Purchase Threshold but Not Exceeding the SAT ($150K)
Acquisition Plan Action ID: VA252‐18‐AP‐4518
1. Contracting Activity: Department of Veterans Affairs, Great Lakes Acquisition Center, NCO
12 – Northern Tier Construction Team, 115 South 84th Street, Milwaukee, WI 53214.
Requesting Activity: Department of Veterans Affairs, VISN 12, Clement J. Zablocki Medical Center, 5000 W. National Avenue, Milwaukee, WI. Purchase Request (2237) Number: 695‐ 18‐3‐6985‐0043
2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:
The HILTI Firestop Systems product is an integration of materials, assemblies and components to provide firestopping to prevent fire from spreading through penetrations in walls, ceiling and floors throughout the medical center.
The estimated expected cost of HILTI firestopping on this contact (1% of construction) is
$3,000.00.
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:
Firestopping is achieved through assemblies, not just materials and it is imperative approved assemblies are used and the assemblies are the same throughout the hospital to allow for inspections and adequate compliance when The Joint Commission and VA inspect for accreditation of the hospital and the safety of patients and staff. It is necessary to match existing systems to ensure there are no interface problems, approved assemblies are used in lieu just materials and all systems are UL approved.
4. Description of market research conducted and results or statement why it was not conducted:
We established HILTI as our standard. The other Firestop systems on the market are not compatible with HILTI. The products cannot be mixed together in a penetration because this would void the UL rating required. Were to switch systems we would not be able to maintain the existing firestop in the hospital and would be forced to remove and replace entire systems.
VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under $150K
VHAPM Part 813.106 Page 2 of 2 Original Date: 08/30/17
5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106‐
1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
Jerrod Schleis Date Contracting Officer
VHAMIWSchleJ Typewritten Text 28 March 2018
| 2018-03-28T09:39:38-0500 | |
| Jerrod J Schleis 1002181 |
File details come from the government source that posted it.