ATTACHMENT I - ABI Doppler_Spec Sheets .pdf
PDF 2 MB Posted
- Solicitation number
- 36C25027Q0089
About this file
This document is an equipment specification sheet for medical device procurement at the Indianapolis VA facility under the Lawrence/Northeast Indiana Clinic Activation project. The acquisition specifies five (5) units of the Summit Doppler L250 ABI System with 8 MHz Bi-directional Doppler Probe (model L250AB, manufacturer Cooper Surgical, vendor number 037_EQPT). The portable vascular Doppler system is designated for noninvasive assessment of peripheral circulation and measurement of ankle and brachial systolic pressures to calculate ankle-brachial index values, supporting the detection of peripheral arterial disease.
The equipment will be distributed across five locations within the multi-specialty departments: Cardiology Exam rooms 613 and 615, and Podiatry Exam rooms 205, 206, and 207. Each system includes a handheld Doppler unit powered by three AA alkaline batteries (rated for approximately 100 four-minute examinations), an 8 MHz bidirectional vascular probe, two blood-pressure cuffs, aneroid pressure gauge, compact waveform printer with rechargeable 3.7V lithium-ion battery (rated for up to 500 prints), adhesive-backed paper, carrying case, and ABI reference materials. The handheld unit measures approximately 140 × 70 × 35 mm and weighs 320 grams. The printer requires standard 100–120 VAC, 50/60 Hz electrical receptacle for charging. No site drawing, pre-installation work, mechanical gas, plumbing water, or special technology infrastructure is required. The equipment is portable with battery and receptacle power capabilities only.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25027Q0089.pdf | ||
| ATTACHMENT III - Doppler_SOW.docx | DOCX document | |
| ATTACHMENT II - Vascular Doppler_Spec Sheets.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Lawrence/Northeast Indiana - Clinic Activation Indianapolis VA
Model / Model #: Summit Doppler L250 ABI System w/8 MHz Bi-directional Doppler Probe / L250AB
Description: Doppler, OB/Vascular, Handheld
Manufacturer / Manufacturer #: Cooper Surgical / L250AB / SD8B
Vendor / Vendor #: / 037_EQPT Group: ME
Mounting: Portable Responsibility: VV
Long Description:
Category: Joint Services Number
Electrical (1): (V), (BTU), (Hz), (A), (P) Electrical Description (1): LIFEDOP ABI 250 SYSTEM. BATTERY TYPE: AA ALKALINE
1.5V X 3: LITHIUM ION 3.7V
Electrical (2): 120.00 (V), (BTU), 60.00 (Hz), (A), 1.00 (P) Electrical Description (2): PRINTER.
Dimensions (1): 2.76in (7.01cm) (w), 5.79in (14.71cm) (d), 1.38in (3.51cm) (h), 0.71lbs (0.32kg) (weight) Dimensions Description (1): LifeDop ABI 250 System.
Dimensions (2): 3.31in (8.41cm) (w), 5.35in (13.59cm) (d), 1.69in (4.29cm) (h), 0.62lbs (0.28kg) (weight)
Total Qty: 5
Portable vascular Doppler system for noninvasive assessment of peripheral circulation and measurement of ankle and brachial systolic pressures for manual ankle-brachial index calculation. Includes a handheld Doppler, 8 MHz bidirectional vascular probe, two blood-pressure cuffs, aneroid pressure gauge, compact waveform printer, adhesive-backed paper, carrying case, and ABI reference materials.
SALIENT FEATURES / CHARACTERISTICS
• 8 MHz bidirectional probe for detecting peripheral blood flow toward and away from the probe.
• Audible Doppler signals and visual indication of flow direction and relative signal strength.
• Two-cuff and aneroid configuration for obtaining arm and ankle systolic pressures.
• Automatic waveform scaling and printing on adhesive-backed paper for attachment to assessment forms.
• Handheld Doppler powered by three 1.5 V AA alkaline batteries; rated for approximately 100 four-minute examinations.
• Printer powered by a rechargeable 3.7 V lithium-ion battery; rated for up to 500 prints. Supplied charging adapter requires 100–120 VAC, 50/60 Hz.
• Handheld unit approximately 140 × 70 × 35 mm; weight approximately 320 g.
Item #: M4106
Alt Item #:
Certifications
Item Information
Powered by EquipWareᵀᴹ Thursday, September 10, 2026 12:58 PMPage 1 of 6
Special Instructions:
Mechanical (Gas)
Electrical
Plumbing (Water)
Receptacle (Standard), Battery Powered
Technology
Dimensions Description (2): Printer.
Clearance (1): (top), (bot), (l), (r), (f), (bk), Site Drawing Required / Preinstall:
No / No
Thursday, September 10, 2026 12:58 PMPage 2 of 6
Accessories/Options
Project Location
N E F L Arch Room # Alt Room # Room Name Dept # Dept Name
1 0 0 0 613 Cardiology Exam, Cardiology 00 Multi-Specialty
1 0 0 0 615 Cardiology Exam, Cardiology 00 Multi-Specialty
1 0 0 0 205 Podiatry Exam, Podiatry 00 Multi-Specialty
1 0 0 0 206 Podiatry Exam, Podiatry 00 Multi-Specialty
1 0 0 0 207 Podiatry Exam, Podiatry 00 Multi-Specialty
Thursday, September 10, 2026 12:58 PMPage 3 of 6
Accurate, Portable Bi-directional Dopplers The LifeDop® ABI systems are an efficient, economical, and portable solution for performing ABI exams. These easy-to-use LifeDop systems are also highly accurate, quickly obtaining the ankle-brachial index (ABI) to assist with detection of peripheral arterial disease (PAD). Both the LifeDop 250 and the LifeDop 300 offer automatic waveform scaling and printing. Exam may meet CPT requirements as defined in the AMA CPT manual.*
LifeDop 250 and LifeDop 300 handheld Doppler systems feature a highly sensitive 8 MHz bi-directional vascular probe, proven effective for locating surface vessels with ease. It also allows the system to obtain pressures at two ankle sites, the dorsalis pedis (DP) and posterior tibial (PT) as well as locate and store arterial waveforms. Additional features include:
• �Clear display that shows blood flow direction and relative signal frequency
• �Fast waveform printouts for both ankles on adhesive-backed paper for attaching to assessment forms
• �Complete ABI system that includes Doppler probe, printer, cuffs, carrying case, aneroid, and ABI reference materials
LifeDop 250 ABI System: Measures systolic pressures to easily calculate ABI, with large displays for heart rate and battery status.
LifeDop 300 ABI System: Featuring a convenient keypad for entering pressure data, it performs automatic ABI calculations.
LifeDop® ABI Systems – Fast, Easy PAD Diagnosis is in Your Hands
Cuffs & Aneroid
Specifications LifeDop ABI System
• �Dimensions: 147 mm x 70 mm x 35 mm
• �Weight: 320 grams
• �Operating Temperature: 10˚ to 30˚C
• �Operating Humidity: 30 to 75%
• �Transport/Storage Temperature: –20˚ to 50˚C
• �Transport/Storage Humidity: 5 to 90%, non-condensing for both units
(beyond 30 days, battery to be stored between –20˚ and 30˚C)
• �Battery Life: Forty, 12-minute exams
• �Battery Type: AA Alkaline 1.5V x 3: lithium ion 3.7V
• �Audio Bandwidth and Power: 245 Hz – 4 KHz, 0.33W
Printer
• �Dimensions: 136 mm x 84 mm x 43 mm
• �Weight: 280 grams
• �Operating Temperature: 0˚ to 30˚C
• �Operating Humidity: 20 to 85%
• �Transport/Storage Temperature: –20˚ to 60˚C
• �Battery Life: Up to 500 prints
• �Printer Paper Type/Size (Max):
Thermal, 58 mm wide, 33 mm diameter
• �Printer Speed: 35 mm/sec, 8 seconds for standard printout
• �Printer Resolution: 48 mm wide, 8 dots/mm, 384 dots/line
• �Printer Impact Resistance: 1.5 meter on linoleum floor
• �Printer Communication: RS232, 115.2K, 8/1, no parity
• �Printer Recharger: Input – 100-120VAC, 29VA, 50/60Hz, Output –
5VDC, 2.3A, center positive
• �Waveform Frequency Scale: Auto-scaled to 4 KHz, 2 KHz and 1 KHz
• �Waveform Time Scale: 25 mm/sec, 100 mm with 4 seconds of data
• �Printout Length: 38 mm total with header
800.243.2974 | 203.601.5200 www.coopersurgical.com/distribution 95 Corporate Drive, Trumbull, CT 06611
©2018 CooperSurgical, Inc. 82491 Rev. 7/18
Item Number Description
L300AC LifeDop 300 ABI System with 4 cuffs, Aneroid and Printer
L250AC LifeDop 250 ABI System with 4 cuffs, Aneroid and Printer
L250AB LifeDop 250 ABI System with 2 cuffs, Aneroid and Printer
SD5B 5 MHz Bi-directional Probe
SD8B 8 MHz Bi-directional Probe
K180 Adhesive Backed Label Paper (5 Rolls)
K185 Label Paper (5 Rolls)
Available for Sale Where CE Mark is Required
LifeDop® 300 ABI System
LifeDop® 250 ABI System
* �Source: Current Procedural Terminology (CPT) is copyright 2017 American Medical Association. All rights reserved. No fee schedules, basic units, relative values, or related listings are included in CPT.
The AMA assumes no liability for the data contained herein. Applicable FARS/DFARS restrictions apply to government use.
CAoption 1 option 2
CAoption 1 option 2
CAoption 1 option 2
CAoption 1 option 2
Project: Lawrence/Northeast Indiana - Clinic Activation Items: M4106
Criteria
Thursday, September 10, 2026 12:58 PMPage 6 of 6
M4106
File details come from the government source that posted it. Updated .