6525--Equipment - TRUPULSE Generator - Cardiology Dept, Cinci
Solicitation number
36C25026Q0151
Issued by

About this file

This document is a Sources Sought Notice for the Department of Veterans Affairs (VA) seeking a TRUPULSE Generator for the Cincinnati VA Medical Center's Cardiology Department. The solicitation (36C25026Q0151) requests information from potential contractors by December 10, 2025, at 4:30 PM EST, with specific submission requirements including business details, GSA contract information, point of contact, DUNS number, business size, and small business classification.

The medical device sought is a TRUPULSE Generator for cardiac electrophysiological procedures, specifically treating paroxysmal atrial fibrillation. Key technical specifications include delivering bipolar biphasic pulses (1760 V between alternate electrodes, 880 V between adjacent electrodes), a foot pedal control interface, touchscreen monitors, patient safety features, and compatibility with VARIPULSE Catheter and Carto mapping system. The procurement is for one generator, with the performance location at Cincinnati VA Medical Center, and the contracting office is located in Battle Creek, Michigan. The solicitation uses NAICS code 334510 and product service code 6525.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Equipment - TRUPULSE Generator - Cardiology Dept, Cinci

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
49037
SOLICITATION NUMBER*
36C25026Q0151
RESPONSE DATE/TIME/ZONE
12-10-2025 4:30PM EASTERN TIME, NEW YORK, USA
ARCHIVE
15 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6525
NAICS CODE*
334510
CONTRACTING OFFICE ADDRESS
Department of Veteran Affairs

Network Contracting Office 10 5500 Armstrong Rd.

Battle Creek MI 49037

POINT OF CONTACT*

Contract Specialist Brooke Hansen brooke.hansen@va.gov No phoned inquiries will be accepted.

PLACE OF PERFORMANCE

ADDRESS
Cincinnati VA Medical Center

3200 Vine Street

Cincinnati OH

POSTAL CODE
45220
COUNTRY
US

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
Department of VA
AGENCY CONTACT’S EMAIL ADDRESS
brooke.hansen@va.gov
EMAIL DESCRIPTION
Contract Specialist

DESCRIPTION

This is a REQUEST FOR INFORMATION and SOURCES SOUGHT for a TRUPULSE Generator Contractors that deem themselves capable of meeting the requirement shall provide the below information to Brooke Hansen, Contracting Officer, at Brooke.Hansen@va.gov no-later-than Wednesday, December 10, 2025 at 4:30PM, EST, referencing (36C25026Q0151). Responses shall include: (1) Business Name and Address, (2) GSA Contract Number and expiration date, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) DUNS and NAICS code (5) Business Size SMALL or LARGE (6) Type of Small Business (if applicable): service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) A concern that is not a manufacturer of the supply shall provide the manufacturers name and size standard (8) Country of Origin. If the concern is the manufacture and the sole distributor, please provide documentation to that effect.

Please see requirements below:

Cincinnati VA Medical Center, located at 3200 Vine Street, Cincinnati, OH 45220, is requesting the purchase of one TRUPULSE generator or equivalent.

The device to be supplied shall include:

TRUPULSE Generator for use in cardiac electrophysiological procedures, specifically for the treatment of paroxysmal atrial fibrillation. Here are some key specifications an equivalent must include:

Pulsed Field Generation: Deliver short, bipolar biphasic pulses with an energy of 1760 V between alternate electrodes and 880 V between adjacent electrodes.

User Interface: Feature a foot pedal for control and touchscreen monitors for management from both the operating theatre and control room.

Safety Features: Include output accuracy, impedance measurement accuracy, and safety devices to ensure patient safety during procedures.

Compatibility: Must connect with the VARIPULSE Catheter and include NATIVE integration with our current (ONLY) mapping system, Carto.