36C25020B0010-0003002.pdf

PDF Posted

Attached to
552-19-106: Replace Elevator Controls (VA-20-00011217) Federal contract opportunity
Solicitation number
36C25020B0010
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This document includes a presolicitation notice and project plans for replacing elevator controls at a Department of Veterans Affairs medical center. The project involves providing all labor, materials, equipment, and supervision to replace outdated elevator controls in Building 330 at the Dayton VA Medical Center located at 4100 West Third Street in Dayton, Ohio. Work must be completed within 360 calendar days of notice to proceed according to specifications and drawings.

The solicitation will be issued as a 100% set-aside for service-disabled veteran-owned small businesses and posted on January 15, 2020 at www.FBO.gov with proposals due approximately 30 days later. The project value is estimated between $2-5 million under NAICS code 238290 with a small business size standard of $15 million. The service-disabled veteran-owned small business must perform a minimum of 25% of construction work. Bid, payment and performance bonds will be required along with a one-time site visit. Questions should be emailed by the deadline to the identified contracting officer.

36C25020B0010 0003 Attachment 2 - Drawing AS111.pdf

View the file

Other files for this federal contract opportunity

Other files attached to 552-19-106: Replace Elevator Controls (VA-20-00011217), newest first.
File Type Posted
36C25020B0010-0003000.docx DOCX document
36C25020B0010-0003003.pdf PDF
36C25020B0010-0003001.docx DOCX document
36C25020B0010-0002000.docx DOCX document
36C25020B0010-0001000.docx DOCX document
36C25020B0010-002.pdf PDF
36C25020B0010-001.docx DOCX document
36C25020B0010-004.pdf PDF
36C25020B0010-003.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AS111

SERVER ROOM

MEZZANINE

KEY PLAN

N

BLDG 330

PROJECT BOUNDARY

SERVER ROOM

S3.C2

S3.C2

A1

/2

5 1/2" 21' - 4 3/8"

1' - 5 5/8" +/-

22' - 10"

HOLLOW METAL FRAME

SEE DOOR SCHEDULE

WALL TYPE, SEE PLANS

FRAMING STUD HEADER

SEALANT BOTH SIDES

WOOD SHIM

6 3/4"

3 5/8"

HOLLOW METAL FRAME

SEE DOOR SCHEDULE

WALL TYPE, SEE PLANS

DOUBLE STUD FRAMING

SEALANT BOTH SIDES

WOOD SHIM6

/4

/8

F1

AS SCHEDULED 2" TYP

A S

S C

H E

D U

LE

D

D1

A S

S C

H E

D U

LE

D

AS SCHEDULED

DOOR AND FRAME TYPE LEGEND

AS111

TYP

AS111

TYP

A

B

C

D

E

F

G

H

I

J

K

ARCHITECTURAL GENERAL NOTES

ARCHITECTURAL PLAN NOTES

ALL DIMENSIONS SHOWN ARE TO FACE OF WALL FRAMING/ MASONRY

UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATES AS "CLR" OR "CLEAR"

INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH.

VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND

REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.

CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS

AFFECTED BY DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.

PROVIDE CONTROL JOINT ON CONTINUOUS GYPSUM BOARD WALLS

GREATER THAN 30' LONG.

PROVIDE CONTROL JOINTS AT CORNERS OF DOORS OR WINDOWS.

ALL NEW PARTITIONS ARE WALL TYPE S3.C2 ON THIS SHEET ONLY. REFER TO

WALL TYPE GENERAL NOTES AS001 FOR WALL BOARD MATERIAL.

REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND

ELECTRICAL FOR COORDINATION ITEMS. COORDINATE AS REQUIRED

INCLUDING NECESSARY FRAMING, BLOCKING, ETC.

VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND

REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.

PATCH EXISTING WALLS WHERE NEW WALLS MEET.

PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ADA REQUIREMENTS.

WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF STUD

FRAMING AT CORNERS UNLESS OTHERWISE NOTED.

ROOF MOUNTED CONDENSING UNIT, REFER TO MECHANICAL DRAWING

REMOVE EXISTING LOUVER. INFILL WITH METAL STUDS, 2 LAYERS TYPE 'X'

GYPSUM BOARD BOTH SIDES. FIRE SEAL BOTH SIDES.

PROVIDE "ELEVATOR MACHINE ROOM" SIGNAGE AND "AUTHORIZED

PERSONNEL ONLY" SIGNAGE PER SHEET AS111 ON FACE OF DOOR.

1/

4"

1/ 4"

3/ 8"

1/

4" 3/

8"

1/ 4"

1/

4"

Elevator Machine Room

9"

9"

1/

4"

1/ 4"

3/ 8"

1/

4" 3/

8"

1/ 4"

1/

4"

Authorized Personnel

Only

9"

9"

1 1/4" TALL LETTERING

FONT: HELVETICA

COLOR: WHITE

FORMAT: VINYL OR SILK SCREEN

CAST ABS PLASTIC SIGNAGE SHEET

COLOR: BLUE

1 1/4" TALL LETTERING

FONT: HELVETICA

COLOR: WHITE

FORMAT: VINYL OR SILK SCREEN

CAST ABS PLASTIC SIGNAGE SHEET

COLOR: BLUE

1' - 6"

M A

X

T Y

P

7" 2 1/2" x 3/8" STEEL

BAR SIDE RAILS

3/4" DIA. STEEL

RUNGS @ 1'-0"

O.C.

2 1/2" x 3/8" BENT

PLATE BRACKETS

WELD TO SIDE

RAILS & ANCHOR

TO WALL OR

STRUCTURE

H E

IG

H

T A

S R

E Q

U

IR

E D

FLOOR LINE

SIDE

ELEVATION

FRONT

ELEVATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

LERCH BATES

4995 BRADENTON AVE. SUITE 200

DUBLIN, OH 43017

TELE: 614-956-9337

BILL MOORE

C U s e rs \e b ro w n \D o c u m e n ts

\1 .1

.0

R e p la c e

E le v a to r C o n tr o ls

H o s p it a l C o m p le x e b ro w n

M

S K

.r v t

/2

/2

:2

:0

P

M

AS111

ELEVATOR MACHINE ROOM

FLOOR PLANGUIDON DESIGN, INC.

1221 N. PENNSYLVANIA ST., SUITE 200

INDIANAPOLIS, IN 46202

TELE: 317-800-6388

JAMES GOODEN

HEAPY ENGINEERING, INC.

1400 W. DOROTHY LANE

DAYTON, OH 45409

TELE: 937-224-0861

MATTHEW GRAHAM

DAYTON, OH VAMC - REPLACE

ELEVATOR CONTROLS

(HOSPITAL COMPLEX)

4100 W Third St, Dayton, OH 45428

552-19-106

PHILLIP WEST, COR

06/07/2019 JLG ELB

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

SCALE: 3/32" = 1'-0"AS111

1 ELEVATOR MACHINE ROOM

SCALE: 1/4" = 1'-0"AS111

2 ENLARGED SERVER ROOM FLOOR PLAN - TENTH FLOOR BUILDING 330

DOOR SCHEDULE

DOOR

ROOM DIMENSIONS DOOR

HEAD DETAIL JAMB DETAIL

FRAME FIRE

RATING

HARDWARE

SET COMMENTS (SEE AS001 FOR NOTES)NUMBER NAME WIDTH HEIGHT THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH

A1 SERVER ROOM 3' - 0" 7' - 0" 1 3/4" D1 METAL PT 3/AS111 4/AS111 F1 HM PT 90 MIN 1

SCALE: 3" = 1'-0"AS111

3 RATED DOOR HEAD DETAIL, HM

SCALE: 3" = 1'-0"AS111

4 RATED DOOR JAMB DETAIL, HM

SCALE: 6" = 1'-0"

SIGNAGE DETAIL

N

N

Revisions: Date:

RFI #2 RESPONSE 02/21/2020

SCALE: 3/4" = 1'-0"AS111

5 ELEVATOR PIT LADDER

Sheets
AS111 - ELEVATOR MACHINE ROOM FLOOR PLAN
AS401 - ENLARGED PLANS

File details come from the government source that posted it. Updated .