4_FDC-4.pdf

PDF 2 MB Posted

Attached to
Correct Fire Damper Deficiencies 583-19-501
Solicitation number
36C25019B0008
Issued by

About this file

36C25019B0008 4_FDC-4.pdf

View the file

Other files

File Type Posted
36C25019B0008-0002000.docx DOCX document
36C25019B0008-0001000.docx DOCX document
Contractor_EMR_Certification_Form.docx DOCX document
Combined_Drawings.pdf PDF
General_Decision_Number_IN180002_11-30-18_IN2.docx DOCX document
3_FDC-3.pdf PDF
2_FDC-2.pdf PDF
RFI_Form_Solicitaton.docx DOCX document
Specs_-_11-30-18.docx DOCX document
1_FDC-1.pdf PDF
36C25019B0008.docx DOCX document
5_FDC-5.pdf PDF
36C25019B0008_1.docx DOCX document
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

C-6123

C-6122

C-6131

TOILET

LAB.

SYSTEMS

NEURAL

ROOM

MECH.

C-6116

TOILET

C-6119

C-6118

C-6120

OFFICE

C-6121

EXAM

C-6124

DN

UP

RESEARCH

ASSISTANT

D-6030

PROJECT

MANAGER

D-6031

FACULTY

D-6032

FACULTY

D-6033

FACULTY

D-6034

FACULTY

D-6035

FACULTY

D-6036

ASSISTANT

DIRECTOR

D-6037

PROGRAM

ASSISTANT

D-6038

DIRECTOR HEALTH

SERVICES RESEARCH

D-6039

COPY/FAX

D-6001

FACULTY

D-6002

S Y

S T

E M

S

A D

M I N

I S

T R

A T

O R

D

RESEARCH

ASSISTANTS/

LIBRARY

D-6004

FACULTY

D-6017

FACULTY

D-6016

FACULTY

D-6018

E L

E C

R

O O

M

D

RESEARCH

ASSISTANTS

D-6015

STORAGE

D-6026

MEN

TOILET

D-6027

WOMEN

TOILET

D-6028

R E

S E

A R

C H

A S

S I S

T A

N T

S

D

R E

S E

A R

C H

A S

S I S

T A

N T

S

D

R E

S E

A R

C H

A S

S I S

T A

N T

S

D

CONFERENCE

ROOM

D-6005

INVESTIGATOR/

INTERVIEW

D-6006

RESEARCH

BIOLOGIST

D-6008

CHRONO-

BIOLOGY

RESEARCH

D-6007

D-6009

D-6010

D-6011

EQUIPT.

D-6032

ENV. SERV.

D-6019

CHASE

"A"

CHASE

"B"

CHASE

"C"

C H

A S

E

D

C H

A S

E

E

C H

A S

E

F

C H

A S

E

G

C H

A S

E

H

CHASE

"K"

CHASE

"J"

DN

UP

ELEV.

P-9

ELEV.

P-8

ELEV.

P-7

S T

A I R

S T

A

S T

A

D-6023

D-6024

D-6025

CHASE

C H

A S

E

ROOM

CONFERENCE

PANTRY

CORRIDOR

STORAGE

C H

A S

E

AUTOCLAVE

STERILIZER

INSTRUMENT ROOM

BSL3 LAB#2

C-6127

C-6126

C-6128

OFFICE #2

OFFICE #3

OFFICE #4

C-6125

OFFICE #1

C-6142

C-6141

EMS

C-6143

UTILITY

ROOM

ELECT.

CLOSET

C-6114

LAB #4

LAB #3

C-6115

C-6117

LAB #5

C-6138

LAB #2

LAB #1

C-6139

DARK RM

C-6140

COLD ROOM

C-6137

C-6132

C-6133

C-6134

C-6136

BSL3 LAB#1

LINEN

CHUTE

ANTE ROOM

C-6129

FD

FD

FD

FIRE

FD

RESEARCH

C O

R R

I D

O R

C

CORRIDOR

C6-30

CORRIDOR

C6-28

CORRIDOR

C6-29

C O

R R

I D

O R

C

C O

R R

I D

O R

C

LOBBY

C6-32

D-6020

D-6021

ENV. SERV.

ENV. SERV.

10329 SQ FT

BUSINESS & OTHER USES

ZONE 1I6-01

14255 SQ FT

EXISTING HEALTH CARE

ZONE 1I6-06

AREA B

AREA A

AREA B

AREA A

LC

FD-6D-001

FD-6D-002

FD-6D-015

FDC-4

SIXTH FLOOR AREA - B

BUILDING 1 REPLACE FIRE

DAMPERS (8) PROJECT

SYMBOLS LIST

HE

EX

EP

LC

TC

NUMBER

DAMPER LOCATION

IDENTIFIER

DAMPER SCHEDULE

IN OR ADJACENT

ROOM NUMBER

FD-6D-001

Electric Room D-6022

D-6022

FULLY SPRINKLERED

MIXED OCCUPANCY

N

BUILDING 1 SIXTH FLOOR

AREA - B

FD-6D-002

Electric Room D-6022

D-6022

FD-6D-015

Men's Restroom D-6027

D-6027

PLAN NOTES

1 REMOVE WOOD BLOCK.

2 REMOVE EXISTING FIRE DAMPERS.

3 INSTALL NEW U.L. LISTED AND

LABELED FIRE DAMPER TO MEET

COMPLIANCE WITH FIRE WALL RATING.

4 ENSURE THAT NEW FIRE DAMPER

FILLS ENTIRE OPENING WITHIN DUCT.

1 2 3 4

1 2 3 4

1 2 3 4

AutoCAD SHX Text

SINK

AutoCAD SHX Text

SINK

AutoCAD SHX Text

AutoCAD SHX Text

4_FDC-4 - FAILED

AutoCAD SHX Text Date

AutoCAD SHX Text FP&C Proj.#:

AutoCAD SHX Text Revisions

AutoCAD SHX Text

VAMC

AutoCAD SHX Text Richard L. Roudebush

AutoCAD SHX Text Indianapolis, IN 46202

AutoCAD SHX Text 1481 West 10th St.

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text AutoCAD File Name

AutoCAD SHX Text Building No.

AutoCAD SHX Text Client Project No.

AutoCAD SHX Text Contract No.

AutoCAD SHX Text Project Title

AutoCAD SHX Text

VA MEDICAL CENTER

AutoCAD SHX Text

INDIANAPOLIS, IN

AutoCAD SHX Text Drawn By

AutoCAD SHX Text Location

AutoCAD SHX Text Designed By

AutoCAD SHX Text Checked By

AutoCAD SHX Text Scale:

AutoCAD SHX Text Sht. Of 6

AutoCAD SHX Text Date

AutoCAD SHX Text Drawing No.

AutoCAD SHX Text

HORIZONTAL EXIT PASSAGEWAY

AutoCAD SHX Text

SMOKE RESISTIVE HAZARDOUS AREA

AutoCAD SHX Text

EXIT

AutoCAD SHX Text

SUITE DESIGNATIONS

AutoCAD SHX Text

30 MINUTE SMOKE BARRIER

AutoCAD SHX Text

1 HOUR FIRE/SMOKE BARRIER

AutoCAD SHX Text

2 HOUR FIRE/SMOKE BARRIER

AutoCAD SHX Text

1 HOUR FIRE BARRIER

AutoCAD SHX Text

2 HOUR FIRE BARRIER

AutoCAD SHX Text

AREA OPEN TO CORRIDOR -

AutoCAD SHX Text

AREA OPEN TO CORRIDOR -

AutoCAD SHX Text

EXIT PASSAGEWAY

AutoCAD SHX Text

LINEN CHUTE

AutoCAD SHX Text

TRASH CHUTE

AutoCAD SHX Text

NON-FIRE-RATED PARTITION

AutoCAD SHX Text

EXIT STAIR OR PASSAGEWAY

AutoCAD SHX Text

WITH SMOKE DETECTION

AutoCAD SHX Text

NO SMOKE DETECTION REQUIRED

AutoCAD SHX Text

NOT INCLUDED IN SOC

AutoCAD SHX Text

CHUTES/ACCESS/DISCHARGE

AutoCAD SHX Text

HAZARDOUS AREA

AutoCAD SHX Text

SLEEPING SUITE

AutoCAD SHX Text

NON-SLEEPING SUITE

AutoCAD SHX Text

NON-PATIENT SUITE

AutoCAD SHX Text

2 HOUR FLOOR/CEILING ABOVE

AutoCAD SHX Text

1 HOUR FLOOR/CEILING ABOVE

AutoCAD SHX Text

3 HOUR FIRE BARRIER

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

SPRINKLER/FIRE ALARM ZONE

AutoCAD SHX Text 10-18-18

AutoCAD SHX Text A.F.

AutoCAD SHX Text J.P.

AutoCAD SHX Text J.P.

AutoCAD SHX Text 583-19-501

Sheets and Views
MAIN TAB

File details come from the government source that posted it.