4_FDC-4.pdf
PDF 2 MB Posted
- Attached to
- Correct Fire Damper Deficiencies 583-19-501
- Solicitation number
- 36C25019B0008
About this file
36C25019B0008 4_FDC-4.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019B0008-0002000.docx | DOCX document | |
| 36C25019B0008-0001000.docx | DOCX document | |
| Contractor_EMR_Certification_Form.docx | DOCX document | |
| Combined_Drawings.pdf | ||
| General_Decision_Number_IN180002_11-30-18_IN2.docx | DOCX document | |
| 3_FDC-3.pdf | ||
| 2_FDC-2.pdf | ||
| RFI_Form_Solicitaton.docx | DOCX document | |
| Specs_-_11-30-18.docx | DOCX document | |
| 1_FDC-1.pdf | ||
| 36C25019B0008.docx | DOCX document | |
| 5_FDC-5.pdf | ||
| 36C25019B0008_1.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
C-6123
C-6122
C-6131
TOILET
LAB.
SYSTEMS
NEURAL
ROOM
MECH.
C-6116
TOILET
C-6119
C-6118
C-6120
OFFICE
C-6121
EXAM
C-6124
DN
UP
RESEARCH
ASSISTANT
D-6030
PROJECT
MANAGER
D-6031
FACULTY
D-6032
FACULTY
D-6033
FACULTY
D-6034
FACULTY
D-6035
FACULTY
D-6036
ASSISTANT
DIRECTOR
D-6037
PROGRAM
ASSISTANT
D-6038
DIRECTOR HEALTH
SERVICES RESEARCH
D-6039
COPY/FAX
D-6001
FACULTY
D-6002
S Y
S T
E M
S
A D
M I N
I S
T R
A T
O R
D
RESEARCH
ASSISTANTS/
LIBRARY
D-6004
FACULTY
D-6017
FACULTY
D-6016
FACULTY
D-6018
E L
E C
R
O O
M
D
RESEARCH
ASSISTANTS
D-6015
STORAGE
D-6026
MEN
TOILET
D-6027
WOMEN
TOILET
D-6028
R E
S E
A R
C H
A S
S I S
T A
N T
S
D
R E
S E
A R
C H
A S
S I S
T A
N T
S
D
R E
S E
A R
C H
A S
S I S
T A
N T
S
D
CONFERENCE
ROOM
D-6005
INVESTIGATOR/
INTERVIEW
D-6006
RESEARCH
BIOLOGIST
D-6008
CHRONO-
BIOLOGY
RESEARCH
D-6007
D-6009
D-6010
D-6011
EQUIPT.
D-6032
ENV. SERV.
D-6019
CHASE
"A"
CHASE
"B"
CHASE
"C"
C H
A S
E
D
C H
A S
E
E
C H
A S
E
F
C H
A S
E
G
C H
A S
E
H
CHASE
"K"
CHASE
"J"
DN
UP
ELEV.
P-9
ELEV.
P-8
ELEV.
P-7
S T
A I R
S T
A
S T
A
D-6023
D-6024
D-6025
CHASE
C H
A S
E
ROOM
CONFERENCE
PANTRY
CORRIDOR
STORAGE
C H
A S
E
AUTOCLAVE
STERILIZER
INSTRUMENT ROOM
BSL3 LAB#2
C-6127
C-6126
C-6128
OFFICE #2
OFFICE #3
OFFICE #4
C-6125
OFFICE #1
C-6142
C-6141
EMS
C-6143
UTILITY
ROOM
ELECT.
CLOSET
C-6114
LAB #4
LAB #3
C-6115
C-6117
LAB #5
C-6138
LAB #2
LAB #1
C-6139
DARK RM
C-6140
COLD ROOM
C-6137
C-6132
C-6133
C-6134
C-6136
BSL3 LAB#1
LINEN
CHUTE
ANTE ROOM
C-6129
FD
FD
FD
FIRE
FD
RESEARCH
C O
R R
I D
O R
C
CORRIDOR
C6-30
CORRIDOR
C6-28
CORRIDOR
C6-29
C O
R R
I D
O R
C
C O
R R
I D
O R
C
LOBBY
C6-32
D-6020
D-6021
ENV. SERV.
ENV. SERV.
10329 SQ FT
BUSINESS & OTHER USES
ZONE 1I6-01
14255 SQ FT
EXISTING HEALTH CARE
ZONE 1I6-06
AREA B
AREA A
AREA B
AREA A
LC
FD-6D-001
FD-6D-002
FD-6D-015
FDC-4
SIXTH FLOOR AREA - B
BUILDING 1 REPLACE FIRE
DAMPERS (8) PROJECT
SYMBOLS LIST
HE
EX
EP
LC
TC
NUMBER
DAMPER LOCATION
IDENTIFIER
DAMPER SCHEDULE
IN OR ADJACENT
ROOM NUMBER
FD-6D-001
Electric Room D-6022
D-6022
FULLY SPRINKLERED
MIXED OCCUPANCY
N
BUILDING 1 SIXTH FLOOR
AREA - B
FD-6D-002
Electric Room D-6022
D-6022
FD-6D-015
Men's Restroom D-6027
D-6027
PLAN NOTES
1 REMOVE WOOD BLOCK.
2 REMOVE EXISTING FIRE DAMPERS.
3 INSTALL NEW U.L. LISTED AND
LABELED FIRE DAMPER TO MEET
COMPLIANCE WITH FIRE WALL RATING.
4 ENSURE THAT NEW FIRE DAMPER
FILLS ENTIRE OPENING WITHIN DUCT.
1 2 3 4
1 2 3 4
1 2 3 4
AutoCAD SHX Text
SINK
AutoCAD SHX Text
SINK
AutoCAD SHX Text
AutoCAD SHX Text
4_FDC-4 - FAILED
AutoCAD SHX Text Date
AutoCAD SHX Text FP&C Proj.#:
AutoCAD SHX Text Revisions
AutoCAD SHX Text
VAMC
AutoCAD SHX Text Richard L. Roudebush
AutoCAD SHX Text Indianapolis, IN 46202
AutoCAD SHX Text 1481 West 10th St.
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text AutoCAD File Name
AutoCAD SHX Text Building No.
AutoCAD SHX Text Client Project No.
AutoCAD SHX Text Contract No.
AutoCAD SHX Text Project Title
AutoCAD SHX Text
VA MEDICAL CENTER
AutoCAD SHX Text
INDIANAPOLIS, IN
AutoCAD SHX Text Drawn By
AutoCAD SHX Text Location
AutoCAD SHX Text Designed By
AutoCAD SHX Text Checked By
AutoCAD SHX Text Scale:
AutoCAD SHX Text Sht. Of 6
AutoCAD SHX Text Date
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
HORIZONTAL EXIT PASSAGEWAY
AutoCAD SHX Text
SMOKE RESISTIVE HAZARDOUS AREA
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
SUITE DESIGNATIONS
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
AREA OPEN TO CORRIDOR -
AutoCAD SHX Text
AREA OPEN TO CORRIDOR -
AutoCAD SHX Text
EXIT PASSAGEWAY
AutoCAD SHX Text
LINEN CHUTE
AutoCAD SHX Text
TRASH CHUTE
AutoCAD SHX Text
NON-FIRE-RATED PARTITION
AutoCAD SHX Text
EXIT STAIR OR PASSAGEWAY
AutoCAD SHX Text
WITH SMOKE DETECTION
AutoCAD SHX Text
NO SMOKE DETECTION REQUIRED
AutoCAD SHX Text
NOT INCLUDED IN SOC
AutoCAD SHX Text
CHUTES/ACCESS/DISCHARGE
AutoCAD SHX Text
HAZARDOUS AREA
AutoCAD SHX Text
SLEEPING SUITE
AutoCAD SHX Text
NON-SLEEPING SUITE
AutoCAD SHX Text
NON-PATIENT SUITE
AutoCAD SHX Text
2 HOUR FLOOR/CEILING ABOVE
AutoCAD SHX Text
1 HOUR FLOOR/CEILING ABOVE
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
SPRINKLER/FIRE ALARM ZONE
AutoCAD SHX Text 10-18-18
AutoCAD SHX Text A.F.
AutoCAD SHX Text J.P.
AutoCAD SHX Text J.P.
AutoCAD SHX Text 583-19-501
| Sheets and Views |
| MAIN TAB |
File details come from the government source that posted it.