2_FDC-2.pdf
PDF 1 MB Posted
- Attached to
- Correct Fire Damper Deficiencies 583-19-501
- Solicitation number
- 36C25019B0008
About this file
36C25019B0008 2_FDC-2.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25019B0008-0002000.docx | DOCX document | |
| 36C25019B0008-0001000.docx | DOCX document | |
| 4_FDC-4.pdf | ||
| General_Decision_Number_IN180002_11-30-18_IN2.docx | DOCX document | |
| RFI_Form_Solicitaton.docx | DOCX document | |
| Specs_-_11-30-18.docx | DOCX document | |
| 1_FDC-1.pdf | ||
| 36C25019B0008.docx | DOCX document | |
| 5_FDC-5.pdf | ||
| Contractor_EMR_Certification_Form.docx | DOCX document | |
| Combined_Drawings.pdf | ||
| 3_FDC-3.pdf | ||
| 36C25019B0008_1.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UP
DN
UP
MECH.
D-3001
D-3037
D-3033
D-3032
S T
O R
A G
E
D
TISSUE
CULTURE
D-3002
D-3003
INSTRUMENT
COMMON
LABORATORY
D-3004
D-3019
STOR.
D-3017
LABORATORY
D-3005
STORAGE
D-3023
FILE
STORAGE
ROOM
D-3022
STOR.
D-3020
HAC
D-3018
LABORATORY
D-3016
E L
E C
R
O O
M
D
W O
R K
M
D
GLASSWARE/VMU
KITCHEN
D-3015
LABORATORY
D-3006
C O
R R
I D
O R
STOR.
D-3028
STAFF
D-3027
VMU WARD
D-3014
LABORATORY
D-3007
MEN
TOILET
TOILET
WOMEN
D-3029
D-3030
C O
N F
R
O O
M
D
VMU WARD
D-3013
CORRIDOR
LABORATORY
D-3008
TELE. RM
D-3031
O F
F I C
E
D
D
D-3009
DN
UP
C H
A S
E
CHASE
C H
A S
E
CHASE
CHASE
C H
A S
E
C H
A S
E
CHASE
C H
A S
E
CHASE
"A" "B"
"C"
D
E
F
G
H
"K"
"J"
ELEV.
S-7
ELEV.
P-9
ELEV.
P-8
ELEV.
P-10
LOBBY
S T
A I
ASSOC. CHIEF OF
STAFF RESEARCH
AND DEVELOPMENT
RESEARCH
STAFF
C H
A S
E
S T
A I
C
C3-15
C O
R R
I D
O R
C
C3-30
C3-27
CORRIDOR
E3019
OBSERVE/
TREAT
E3038
OBSERVE/
TREAT
E3041
EXAM
E3030
CASE
MANAGER
CASE
MANAGER
E3036
EXAM
E3022
EXAM
E3032
EXAM 14
E3026
E3029
SOILED
E3031
CLEAN
UTILITY
E3025
STAFF
E3033
TOILET
E3024
EXAM
E3023
E3021
EXAM
E3020
EXAM
E3047
STAFF
EXAM
EXAM
E3037
EXAM
E3039
EXAM
PATIENT
TOILET
E3046
NURSE
STATION
E3049
INTAKE
ASSESS
E3051
C/OUT
ASSESS
E3048
STAFF
C3-29
E3050
EXAM
E3052
EXAM
E3056
EXAM
E3060
EXAM
E3058
EXAM
E3057
EXAM
E3001
UNISEX
TOILET
E3054
OFFICE
E3055
OFFICE
C3-31
PASSAGE
E3064
TELE/
DATA
E3063
ELECTRIC
ROOM
RE
FE
R
CORRIDOR
CORRIDOR
C3-30
CORRIDOR
C3-27
CORRIDOR
C3-25
CORRIDOR
E3019
OBSERVE/
TREAT
E3040
EXAM 20
E3041
EXAM 21
E3030
CASE
MANAGER
E3028
CASE
MANAGER
E3036
EXAM
E3022
EXAM 10
E3026
EXAM 13
E3027
EQUIP.
E3029
SOILED
UTILITY
E3031
CLEAN
UTILITY
E3025
STAFF
TOILET
E3033
STAFF
TOILET
E3024
EXAM 12
E3023
EXAM 11
E3021
EXAM 9
E3020
EXAM 8
C
C O
R R
I D
O R
C
C O
R R
I D
O R
E3047
STAFF
E3034
EXAM 15
E3035
EXAM 16
E3037
EXAM 18
E3039
EXAM 19
E3043
MEDS
E3042
PATIENT
TOILET
E3046
NURSE
STATION
E3017
NURSE
STATION
E3049
INTAKE
ASSESS
E3051
C/OUT
ASSESS
E3048
STAFF
C3-29
CORRIDOR
E3050
EXAM 22
E3052
EXAM 23
E3056
EXAM 24
E3060
EXAM 28
E3058
EXAM 26
E3057
EXAM 25
E3001
UNISEX
TOILET
E3054
OFFICE
E3055
OFFICE
PASSAGE
E3064
TELE/
DATA
E3063
ELECTRIC
ROOM
#14-4
STAIR
E3053
OFFICE
CORRIDOR
C3-22
CORRIDOR
CORRIDOR
C3-23
CORRIDOR
C
C O
R R
I D
O R
O F
F I C
E
OFFICE
R E
S E
A R
C H
R E
S E
A R
C H
RESEARCH
RESEARCH
OFFICE
RESEARCH
OFFICE
RESEARCH
OFFICE
RESEARCH
OFFICE
RESEARCH
OFFICE
COMP.RM
D-3021
CLEAN UT
C
S
L
E
E
P
S
T
U
D
Y
C-3162
SLEEP STUDY
STORAGE
C-3158
CLEAN UT
TOILET
C-3160
ANTE-ROOM
ENTER
C-3159
SHOWER
ROOM
PPE LINE
C-3161A
C-3161
ROOM
ISOLATION
CLOSET
C-3159A
C L
O S
E T
C
A
CLOSET
C-3162A
AREA B
AREA B
12150 SQ FT
BUSINESS AND OTHER USES
ZONE 1I3-01
10174 SQ FT
BUSINESS AND OTHER USES
ZONE 1I3-02
AREA A
AREA A
FD-3D-004
THIRD FLOOR AREA - B
BUILDING 1 REPLACE FIRE
DAMPERS (8) PROJECT
SYMBOLS LIST
HE
EX
EP
LC
TC
NUMBER
DAMPER LOCATION
IDENTIFIER
DAMPER SCHEDULE
IN OR ADJACENT
ROOM NUMBER
FD-3D-O04
Men's Restroom D-3029
D-3029
FULLY SPRINKLERED
MIXED OCCUPANCY
N
BUILDING 1 THIRD FLOOR
AREA - B
FDC-2
PLAN NOTES
1 REMOVE WOOD BLOCK.
2 REMOVE EXISTING FIRE DAMPER.
3 INSTALL NEW U.L. LISTED AND
LABELED FIRE DAMPER TO MEET
COMPLIANCE WITH FIRE WALL RATING.
4 ENSURE THAT NEW FIRE DAMPER
FILLS ENTIRE OPENING WITHIN DUCT.
1 2 3 4
AutoCAD SHX Text D-3034
AutoCAD SHX Text
STAIR #8-3
AutoCAD SHX Text
DN
AutoCAD SHX Text E3062
AutoCAD SHX Text
LOCKER
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
STAFF
AutoCAD SHX Text E-3002
AutoCAD SHX Text
MH
AutoCAD SHX Text
EXAM 1
AutoCAD SHX Text E-3004
AutoCAD SHX Text
MH
AutoCAD SHX Text
EXAM 2
AutoCAD SHX Text E-3006
AutoCAD SHX Text
MH
AutoCAD SHX Text
EXAM 4
AutoCAD SHX Text E-3008
AutoCAD SHX Text
MH
AutoCAD SHX Text
EXAM
AutoCAD SHX Text E-3010
AutoCAD SHX Text
MH
AutoCAD SHX Text
EXAM
AutoCAD SHX Text E-3014
AutoCAD SHX Text
MH
AutoCAD SHX Text
STAFF
AutoCAD SHX Text E-3016
AutoCAD SHX Text
MH
AutoCAD SHX Text
STAFF
AutoCAD SHX Text E-3018
AutoCAD SHX Text
HAC
AutoCAD SHX Text C3-24
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text E3059
AutoCAD SHX Text
EXAM 27
AutoCAD SHX Text E3003
AutoCAD SHX Text
CHECK-IN
AutoCAD SHX Text E3062
AutoCAD SHX Text
LOCKER
AutoCAD SHX Text
ROOM
AutoCAD SHX Text E3061
AutoCAD SHX Text E-3005
AutoCAD SHX Text
MH
AutoCAD SHX Text
EXAM 3
AutoCAD SHX Text E-3007
AutoCAD SHX Text
MH
AutoCAD SHX Text
EXAM
AutoCAD SHX Text E-3009
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text E-3011
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text E-3012
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text C3-20
AutoCAD SHX Text
WAITING ROOM
AutoCAD SHX Text E-3013
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text E-3015
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text E-3044
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text E-3045
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text D-3039
AutoCAD SHX Text D-3036
AutoCAD SHX Text D-3034
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C3-19
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C3-18
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text E3065
AutoCAD SHX Text D-3035
AutoCAD SHX Text D-3040
AutoCAD SHX Text
STOR.
AutoCAD SHX Text D-3040
AutoCAD SHX Text
AutoCAD SHX Text
2_FDC-2 - FAILED
AutoCAD SHX Text Date
AutoCAD SHX Text FP&C Proj.#:
AutoCAD SHX Text Revisions
AutoCAD SHX Text
VAMC
AutoCAD SHX Text Richard L. Roudebush
AutoCAD SHX Text Indianapolis, IN 46202
AutoCAD SHX Text 1481 West 10th St.
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text AutoCAD File Name
AutoCAD SHX Text Building No.
AutoCAD SHX Text Client Project No.
AutoCAD SHX Text Contract No.
AutoCAD SHX Text Project Title
AutoCAD SHX Text
VA MEDICAL CENTER
AutoCAD SHX Text
INDIANAPOLIS, IN
AutoCAD SHX Text Drawn By
AutoCAD SHX Text Location
AutoCAD SHX Text Designed By
AutoCAD SHX Text Checked By
AutoCAD SHX Text Scale:
AutoCAD SHX Text Sht. Of 6
AutoCAD SHX Text Date
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
HORIZONTAL EXIT PASSAGEWAY
AutoCAD SHX Text
SMOKE RESISTIVE HAZARDOUS AREA
AutoCAD SHX Text
EXIT
AutoCAD SHX Text
SUITE DESIGNATIONS
AutoCAD SHX Text
30 MINUTE SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
2 HOUR FIRE/SMOKE BARRIER
AutoCAD SHX Text
1 HOUR FIRE BARRIER
AutoCAD SHX Text
2 HOUR FIRE BARRIER
AutoCAD SHX Text
AREA OPEN TO CORRIDOR -
AutoCAD SHX Text
AREA OPEN TO CORRIDOR -
AutoCAD SHX Text
EXIT PASSAGEWAY
AutoCAD SHX Text
LINEN CHUTE
AutoCAD SHX Text
TRASH CHUTE
AutoCAD SHX Text
NON-FIRE-RATED PARTITION
AutoCAD SHX Text
EXIT STAIR OR PASSAGEWAY
AutoCAD SHX Text
WITH SMOKE DETECTION
AutoCAD SHX Text
NO SMOKE DETECTION REQUIRED
AutoCAD SHX Text
NOT INCLUDED IN SOC
AutoCAD SHX Text
CHUTES/ACCESS/DISCHARGE
AutoCAD SHX Text
HAZARDOUS AREA
AutoCAD SHX Text
SLEEPING SUITE
AutoCAD SHX Text
NON-SLEEPING SUITE
AutoCAD SHX Text
NON-PATIENT SUITE
AutoCAD SHX Text
2 HOUR FLOOR/CEILING ABOVE
AutoCAD SHX Text
1 HOUR FLOOR/CEILING ABOVE
AutoCAD SHX Text
3 HOUR FIRE BARRIER
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
SPRINKLER/FIRE ALARM ZONE
AutoCAD SHX Text 10-18-18
AutoCAD SHX Text A.F.
AutoCAD SHX Text J.P.
AutoCAD SHX Text J.P.
AutoCAD SHX Text 583-19-501
| Sheets and Views |
| MAIN TAB |
File details come from the government source that posted it.