PKG 294 - Cutsheet.pdf

PDF 302 KB Posted

Attached to
6630--Tissue Processor | Tulsa, OK | 623 Federal contract opportunity
Solicitation number
36C24W25Q0392
Issued by
Department of Veterans Affairs

About this file

This document is a VA equipment specification sheet for a Tissue-Tek Prisma® Plus Automated Slide Stainer manufactured by SakuraUS. The device is designed for pathology laboratories, with capabilities to process up to 530 slides per hour using 31-51 reagent reservoirs and supporting up to 50 different staining protocols. Key technical specifications include a two-level design, temperature ranges of 86-158°F for heating and drying stations, and the ability to load up to 60 slides per run. The equipment will be installed in the Histology Laboratory-2A322 within the Pathology and Laboratory Medicine Service, with government installation planned and a one-year warranty. Electrical requirements include a 120-volt special outlet and vacuum medical gas connection, with a total equipment weight of 330 pounds. The device is FDA Class I certified and complies with various international safety standards.

View the file

Other files for this federal contract opportunity

Other files attached to 6630--Tissue Processor | Tulsa, OK | 623, newest first.
File Type Posted
36C24W25Q0392_1.docx DOCX document
FAR 52.225-2 Buy American Certificate.docx DOCX document
RFQ 36C24W25Q0392.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Name:

Project Location:

Cat Code:

TULSA

VV March 31, 2025Date Prepared:

JSN: L9020

VAProject Type:

Project Continent:Project Area:

Model Name: Automated Slide StainerManufacturer: SakuraUS

Dealer:

Phone:

Nomenclature: Tissue Processor, Automatic, 2 Level

Model Number: Tissue-Tek Prisma® Plus

Email: Room Nbr(s): See Attached

Model URL:Manuf URL:

Dimensions

D 28.00 in W 49.00 in H 25.00 in D 1,244.60 mm W 711.20 mm H 635.00 mm

Image

All Images are for representation only, may not reflect final product.

Salient Characteristics Application Automated preparation of routine histological and cytological stains for use in pathology laboratories to assist with the following tasks: staining, dewaxing, rehydration, dehydration, etc.

Throughput Up to 530 slides per hour Number of reservoirs Start - 1 to 3 stations Reagent - 31 to 51 reservoirs Drying - 0 to 2 stations Wash - 0 to 4 stations (8 programmable steps) Heating (optional) - 2 stations Capacity Reagent volume - 160, 260 and 680 mL Staining protocols - 11 runs continuously loading, and simultaneously running Baskets - 10 or 20 slide basket Loading - up to 60 slides per run Temperature:

Drying station - 86 ~ 149°F (30 ~ 65°C) Heating station - 86 ~ 158°F (30 ~ 70°C) Heating 2 stations Staining Up to 50 protocols Security Door and cover Certifications IEC 61010-1 2nd ed., CAN/CSA C22.2 61010-1, UL 61010-1 Regulatory status IVD, FDA Class I

Project Name:

Project Location:

Cat Code:

TULSA

VV March 31, 2025Date Prepared:

JSN: L9020

VAProject Type:

Project Continent:Project Area:

NEMA Type:

Data: No

Wall Blocking:

Warranty:

Training:

N/A 1 yr

No No

DC: No Amps: N/AEP: No

Plumbing: N/A Electrical:

Medical Gas:

120 VOLT, SPECIAL OUTLET

VACUUM

Misc Gas: N/A

Drops: N/A

N/ANonMed Gas:

N/AMisc:

1:

2:

3:

4:

5:

6:

8:

9:

10:

11:

12:

Addl Outlets: N/A

Utilities

Sub Trade Required: N/A

Elavator Available

Loading Dock Available

Origin: N/A

Installed By: GOVT

Origin:

3rd Party Field Survey Required:

N/A

N/A

Building Protection Req: N/A N/AVerified Equip Fit through all

Hallways/Doorways:

330.00Weight lbs:

Destination: N/A

Sub Trades:

Installation Date: N/A

Shop Drawings Required: N/A

Equip Cost Includes Installation:

3rd Party Install Cost:

No

N/A

3rd Party Install Start Date: N/A

3rd Party Install End Date: N/A

3rd Party POC Name: N/A 3rd Party POC Cell Phone: N/A

3rd Party POC Email: N/A

Installation/Logistics

N/A

N/A

Destination:

3rd Party Vendor Name: N/A

N/ACalibration and Testing:

Installation Note:

Shop Drawings Date Received: N/A

1Qty:

Department, Room, Quantity

HISTOLOGY LABORATORY-2A322(1)

PATHOLOGY AND LABORATORY MEDICINE SERVICE (240)

File details come from the government source that posted it. Updated .