This document provides details for a federal contract opportunity with the Department of Veterans Affairs to restore the AHU-10 heating and cooling system at the VA medical center in Louisville, Kentucky. The contractor shall demolish existing structures, prepare the site for construction, and furnish all labor, materials, and work required according to the drawings and specifications to restore air handling units 5 through 7. The solicitation number for the pre-solicitation opportunity is 36C24922B0001. The contractor must completely prepare the site, including demolition of current structures, to allow for continued building operations during the project to replace the AHU-10 system serving operating rooms 5 through 7.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

* C.O.R. = CONTRACTING OFFICER'S REPRESENTATIVE.

1. SEE GENERAL PROJECT NOTES FOR NEW WORK FOR ADDITIONAL REQUIREMENTS FOR WORK WITHIN THE EXISTING FACILITY.

2. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL CAREFULLY EXAMINE EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE C.O.R.

3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING DEMOLITION AND CONSTRUCTION.

4. MAINTAIN EXIT EGRESS PATHS TO EXISTING EXIT DOORS DURING CONSTRUCTION.

5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK AND THE ROUTES MUST BE RETURNED TO THEIR

ORIGINAL CONDITION AT THE END OF THE PROJECT.

6. MAINTAIN THE BUILDING IN A WEATHERTIGHT CONDITION AT ALL TIMES.

7. ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH THE C.O.R. TO MINIMIZE DISRUPTIONS OF NORMAL FUNCTIONS OF THE VA'S OCCUPIED AREAS.

8. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PATCH ALL SPRAY-ON FIRE PROTECTION AT REMOVALS, AT ANY EXISTING LOCATIONS WHICH ARE VOID OF PROTECTION WITHIN THE AREA OF WORK AND AT NEW CONSTRUCTION WHICH DISTURBS EXISTING FIRE PROTECTION. FIREPROOFING MUST BE CONTINUOUS AND UNOBSTRUCTED.

9. DO NOT OVERLOAD THE EXISTING BUILDING STRUCTURE. MAINTAIN THE STRUCTURAL INTEGRITY OF ALL STRUCTURAL FRAMING MEMBERS AND SYSTEMS AT ALL TIMES.

10. ALL DEMOLISHED MATERIAL, EXCEPT MATERIAL THAT IS LISTED OR MARKED BY THE ARCHITECT OR THE C.O.R. FOR RETENTION, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE DISPOSED OF. NO DEBRIS RESULTING FROM WORK SHALL BE LEFT IN THE CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK. THE WEIGHT AND COST OF DISPOSAL FOR ALL CONTROLLED SUBSTANCES SUCH AS LEAD AND ASBESTOS SHALL BE TRACKED AND REPORTED. THE GENERAL CONTRACTOR SHALL NOT USE THE VA

TRASH COMPACTOR.

11. REMOVAL OF A PARTICULAR ITEM IS TO INCLUDE ALL RELATED ITEMS, SUCH AS REMOVAL OF WALLS WOULD INCLUDE ASSOCIATED DOORS, HARDWARE, ELECTRICAL, PLUMBING, MECHANICAL, ETC. REFER TO DEMOLITION DRAWINGS FOR MORE INFORMATION. FOR ALL REMOVALS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER

DISCIPLINES INCLUDING BUT NOT LIMITED TO MECHANICAL, ELECTRICAL AND PLUMBING.

12. WHERE CEILINGS ARE SHOWN TO BE REMOVED, ALL UNUSED SUSPENDED EQUIPMENT, WIRES, ANGLES, ETC. SHALL BE REMOVED. SEE DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION. EXISTING LIGHTS MAY BE MAINTAINED AS TEMPORARY CONSTRUCTION LIGHTING.

13. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED AS REQUIRED UNTIL PERMANENT SUPPORT IS PROVIDED IN THE FINAL

CONSTRUCTION.

14. ALL OPENINGS IN EXISTING WALLS, CEILINGS AND FLOORS, WHICH ARE THE RESULT OF REMOVALS AND OTHER NEW CONSTRUCTION ACTIVITY, SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH

SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.

15. ALL EXISTING OPENINGS IN CEILINGS, FLOORS AND WALLS DISCOVERED IN THE EXISTING STRUCTURE SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH. USE ONE FIRE STOPPING SYSTEM FOR ALL SUB-CONTRACTORS.

16. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE ATTACHMENT OR APPLICATION OF NEW MATERIALS OR CONSTRUCTION, PREPARE OR ALTER THE EXISTING SURFACES AS NECESSARY TO PROPERLY ACCOMMODATE THE NEW MATERIALS.

17. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES THAT IMPACT THE NEW WORK. DETERMINE THE SIZE AND LOCATION THE PENETRATIONS FROM THE EXISTING

UTILITIES WITHIN THE NEW WORK. SEAL TIGHT TO ALL PENETRATIONS AND CAULK.

18. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE SAFE'D TO ACHIEVE THE PROPER FIRE RATING BY THE END OF

CONSTRUCTION OPERATIONS FOR EACH DAY.

19. NEW HOLES IN EXISTING ELEVATED FLOOR AND ROOF STRUCTURES FOR NEW WORK MUST BE COORDINATED WITH THE EXISTING STRUCTURE SO THAT CRITICAL STRUCTURAL

MEMBERS ARE NOT DAMAGED.

G E N E R A L N O T E S F O R E X I S T I N G F A C I L I T I E S :

* C.O.R. = CONTRACTING OFFICER'S REPRESENTATIVE.

1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES, RULES, ORDINANCES AND REGULATIONS INCLUDING THE AMERICAN DISABILITIES ACT (ADA), ARCHITECTURAL BARRIERS ACT(ABA), THE VA BARRIER FREE DESIGN GUIDELINES AND THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) GUIDELINES.

2. THE C.O.R. SHALL WORK WITH THE CONTRACTOR TO PROVIDE ACCESS TO TEMPORARY SERVICES REQUIRED TO PROVIDE THE WORK INDICATED. SEE SPECIFICATION SECTION 01 00 00 GENERAL REQUIREMENTS FOR ADDITIONAL REQUIREMENTS ON TEMPORARY ACCESS TO VA UTILITIES.

3. THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE PROVISIONS OF THE SPECIFICATIONS, INCLUDING ALL GENERAL CONDITIONS, SUPPLEMENTARY GENERAL CONDITIONS, AND MATERIAL AND CONSTRUCTION PROVISIONS, WHICH APPLY TO MATERIALS OR CONSTRUCTION METHODS REQUIRED BY THIS PROJECT.

4. PRIOR TO BIDDING, THE GENERAL CONTRACTOR SHALL VISIT THE SITE, EXAMINE, AND ACCEPT ALL EXISTING CONDITIONS. DATES FOR SITE VISITS WILL BE POSTED IN THE CONTRACT DOCUMENTS AS POSTED ON THE FEDERAL BUSINESS OPPORTUNITIES WEBPAGE FOR THIS PROJECT. UNSCHEDULED VISITS WILL NOT BE ALLOWED.

5. VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD BEFORE FABRICATING ANY MATERIALS.

6. IT IS THE INTENT OF THE DOCUMENTS TO INDICATE COMPLETE AND OPERATIONAL SYSTEMS (I.E. STRUCTURAL, HVAC, PLUMBING, ELECTRICAL) THE CONTRACTOR SHALL PROVIDE THE SYSTEMS AS OPERATIONAL SYSTEMS WHICH COMPLY WITH APPLICABLE CODES AND REGULATIONS. THIS NOTE SHALL BE LIMITED TO THE SYSTEMS AS INDICATED BY THE DOCUMENTS AND SHALL NOT INCLUDE CHANGES TO THE SYSTEMS WHICH ALTER INDICATED CAPACITIES, OPERATIONAL CHARACTERISTICS.

7. THE GENERAL CONTRACTOR SHALL VERIFY THE SIZES OF ALL EQUIPMENT OR FIXTURES TO BE INSTALLED IN THE BUILDING THROUGH THE SUBMITTAL PROCESS, AND SHALL MAKE SPECIAL PROVISIONS FOR INSTALLATION OF ANY EQUIPMENT WHICH IS TOO LARGE TO FIT THROUGH A FINISHED OPENING.

8. ALL CONTRACTORS SHALL BE RESPONSIBLE TO PATCH AND REPAIR ALL SURFACES WHERE EXISTING CONSTRUCTION IS REMOVED OR DISTURBED BY WORK UNDER THEIR

CONTRACT.

9. ALL SUSPENDED ITEMS SUCH AS CEILINGS, DUCTS, PIPES, CONDUITS, SHALL BE SUSPENDED (ATTACHED) DIRECTLY TO STRUCTURE AND SHALL NOT BE ATTACHED OR ANCHORED

TO EXISTING PLASTER, ACOUSTIC TILE.

10. NEW PENETRATIONS SUCH AS DUCTS, CONDUITS, PIPING, ELECTRICAL OUTLETS, LIGHT SWITCHES, RECESSED DEVICES OR ITEMS, HOLES, VOIDS, CRACKS IN MODIFIED AND NEW CORRIDOR WALLS, SMOKE PARTITIONS, FIRE RATED PARTITIONS, AND FLOOR SLABS SHALL BE SEALED TO PREVENT PASSAGE OF ANY SMOKE, FLAME, GASES. AS INDICATED IN

THE CONTRACT DOCUMENTS.

11. WHERE NEW CONSTRUCTION REQUIRES CORE DRILLING THROUGH EXISTING STRUCTURAL CONCRETE FLOOR SLABS, AND WALLS THE CONTRACTOR SHALL COORDINATE HIS DRILLING WORK TO AVOID DRILLING INTO A STRUCTURAL ELEMENT, INCLUDING JOISTS, BEAMS, COLUMN.

12. WHERE NEW CONSTRUCTION MATERIAL AND EQUIPMENT IS INDICATED TO BE INSTALLED IN EXISTING CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS FOR PROPER FIT AND FOR ACCESS INTO THE BUILDING PRIOR TO SHOP DRAWING SUBMITTAL, ORDERING AND DELIVERING TO THE SITE.

13. FOR INFECTION CONTROL REASONS, WORK CONDUCTED IN THE CORRIDOR THAT DOES NOT GENERATE DUST MAY ONLY REMOVE UP TO 16 SQUARE FEET OF CEILING TILE AT ONCE. AS LONG AS THIS STANDARD IS FOLLOWED NEGATIVE AIR AND BARRIERS ARE NOT REQUIRED BY THE INFECTION CONTROL NURSES. IF DUST IS GENERATED AND GREATER THAN 16 SF OF CEILING TILES ARE DISTURBED AT ONCE THEN THE WORK AREA SHALL BE SEALED OFF WITH 6 MIL FIRE RETARDANT POLYETHYLENE AND NEGATIVE AIR PROVIDED.

MAINTAIN 5' MINIMUM ACCESS IN CORRIDORS AT ALL TIMES. CLEAN THOROUGHLY PRIOR TO COMPLETION OF A GIVEN WORK AREA BY HEPA VACUUM AND WET MOP. REFER TO

SPECIFICATION 01 35 26 FOR ADDITIONAL INFORMATION.

G E N E R A L N O T E S F O R N E W W O R K :

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

T-691

C U s e rs

\c a rt e \D o c u m e n ts

\0

L o c a l R e v it F ile s \2

\F F

E

L o u is v ill e

R e s to re A

H U

-1

M E

P c a rt e r.

d a n ie l0

.r v t

/3

/2

:2

:0

A

M

GI001

COVER SHEET - SHEET INDEX

Owner

08/12/2021 PQ CD

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

CONSTRUCTION

DOCUMENTS (100%) 1

ROBLEY REX

VA MEDICAL

CENTER

RESTORE AHU-10 SYSTEMS (OR's 5 & 7)

DEPARTMENT OF VETERANS AFFAIRS

ROBLEY REX VA MEDICAL CENTER

SHEET INDEX

SHEET NUMBER SHEET NAME

GENERAL

GI001 COVER SHEET - SHEET INDEX

GI002 ICRA PLANS

G003 LIFE SAFETY PLAN

ARCHITECTURAL

AD144 FOURTH FLOOR DEMOLITION REFLECTED CEILING PLAN

AC144 FOURTH FLOOR REFLECTED CEILING PLAN

MECHANICAL

M001 MECHANICAL LEGEND

MD104 MECHANCIAL FOURTH FLOOR DEMOLITION

MD105 MECHANICAL FIFTH FLOOR DEMOLITION

M104 MECHANICAL FOURTH FLOOR PLAN NEW WORK

M105 MECHANICAL FIFTH FLOOR PLAN NEW WORK

M501 MECHANICAL DETAILS

M601 MECHANICAL SCHEDULES

ELECTRICAL

EE001 LEGEND AND ABBREVIATIONS

ED104 ELECTRICAL FOURTH FLOOR DEMOLITION

ED105 ELECTRICAL FIFTH FLOOR DEMOLITION

EL104 ELECTRICAL FOURTH FLOOR NEW WORK

EP105 ELECTRICAL FIFTH FLOOR NEW WORK

EE601 ELECTRICAL SCHEDULES

SITE LOCATION MAP SITE MAP

# 603-20-202

800 ZORN AVE.

LOUISVILLE, KY 40206

No. Revisions: Date:

3 CONSTRUCTION DOCUMENTS 100% 08/12/2021

T M T M

INFECTION AND DUST CONTROL PLAN LEGEND

DUST MAT (2'-0" X 3'-0")

AREA NOT IN CONTRACT

AREA IN DIFFERENT PHASE

PROVIDE TEMPORARY INFECTION CONTROL / DUST CONTROL

BARRIERS AT THIS LOCATION. REMOVE AFTER CONSTRUCTION

IS COMPLETED PER PHASE INDICATED.

TEMPORARY PLASTIC SHEETING ACCORDING TO ICRA REQUIREMENTS.

DUE TO THE LOCATION OF RENOVATION WORK INDICATED (VAMC SURGERY

DEPARTMENT) CONSTRUCTION IS WITHIN THE HIGHEST INFECTION RISK CATEGORY.

THE INFECTION AND DUST CONTROL PLANS SHALL BE DISTRIBUTED AND APPLIED BY

ALL CONTRACTORS PERFORMING WORK ON THIS PROJECT.

A. REFER TO PHASING PLANS AND SPECIFICATION SECTION 01 35 26, SAFETY REQUIREMENTS FOR

ADDITIONAL INFECTION CONTROL INFORMATION.

B. COORDINATE ALL WORK ASSOCIATED WITH PROJECT FOLLOWING THE SITE-SPECIFIC INFECTION

CONTROL RISK ASSESSMENT PUBLISHED BY THE ROBLEY REX VAMC.

C. AREAS ADJACENT TO IMMEDIATE (PHASED) WORK AREAS WILL BE FULLY OCCUPIED AND FUNCTIONING

NORMALLY THROUGHOUT THE CONSTRUCTION PERIOD.

D. THERE WILL BE ZERO TOLERANCE FOR ANY DUST MIGRATION OUTSIDE OF THE IMMEDIATE WORK SITE

AREAS IDENTIFIED BY PHASING PLANS.

E. ALL WORK OCCURRING WITHIN THE SURGERY DEPARTMENT MUST BE PERFORMED OUTSIDE OF NORMAL

VAMC WORKING HOURS.

F. CONTRACTOR SHALL PROVIDE FOR PROFESSIONAL TERMINAL CLEANING OF PHASED WORK AREAS PRIOR

TO TURNING OVER TO THE VAMC FOR OCCUPANCY.

G. EXTERIOR DEMOLITION ACTIVITIES (INCLUDES CUTTING AND PATCHING):

a. EVALUATE EXISTING SITE CONDITIONS TO DETERMINE THE PRESENCE OF ANY OUTSIDE AIR INTAKES

WITHIN 20' OF THE PROPOSED EXTERIOR WORK.

b. IF PRESENT - DETERMINE IF THE IMPACTED EXTERIOR AREAS OF THE FACILITY CAN OPERATE

TEMPORARILY ON RECIRCULATED AIR VS. OUTSIDE AIR.

• IF FEASIBLE - SEAL OFF AIR INTAKES WITHIN 20' OF DUST GENERATING WORK.

• IF NOT FEASIBLE - ROUTINELY CHECK THE LOW-EFFICIENCY FILTER BANKS LOCATED IN LINE

WITH ADJACENT AIR INTAKE(S) AND REPLACE AS NEEDED TO REDUCE PARTICULATE BUILD-UP.

c. SEAL WINDOWS AND REDUCE OTHER SOURCES OF OUTSIDE AIR INTRUSION (OPEN DOORS IN

STAIRWELLS AND CORRIDORS) THAT MAY BE IMPACTED BY CONSTRUCTION. PAY SPECIAL ATTENTION

TO PROTECTIVE ENVIRONMENT (PE) AREAS.

H. INTERIOR DEMOLITION AND CONSTRUCTION ACTIVITIES DUST AND DEBRIS CONTROL:

a. BARRIER SYSTEMS: PHASED AREAS OF WORK SHALL BE ISOLATED FROM ADJACENT AREAS WITH 1 -

HR. RATED DUST PARTITIONS.

b. DUST PARTITIONS TO BE METAL FRAMED WITH GYPSUM WALL BOARD ON EACH SIDE. PARTITION TO

BE CONSTRUCTED EQUAL TO UL DESIGN U465.

• IN LIEU OF SITE BUILT DUST PARTITIONS, CONTRACTOR MAY UTILIZE PRE-ENGINEERED

(MODULAR) TEMPORARY CONSTRUCTION PARTITIONS LIKE THOSE MANUFACTURED BY EDGE

GUARD PRODUCTS, 216 N. PLATT ST., BEMENT, IL 61813, TELE 217-552-5418, WEBSITE:

WWW.EDGE-GUARD.COM OR APPROVED EQUAL.

c. DUST PARTITIONS SHALL BE INSTALLED WITH A TIGHT SEAL AT FLOOR AND CEILING OR STRUCTURE ABOVE CEILING. WHERE OPERATING ROOM DEMISING WALLS ARE SHOWN TO BE EXTENDED UP TO STRUCTURE ABOVE - PROVIDE AIR TIGHT SEAL AT BOTH TOP OF EXISTING DEMISING WALL (TO BE

EXTENDED) AND AT STRUCTURE ABOVE.

• WHERE O.R. DEMISING WALL EXTENSIONS IMPACT EXISTING FIRE PROOFED STEEL STRUCTURE -

CONTRACTOR SHALL CAREFULLY REMOVE THE FIREPROOFING (ONLY) IN AREA WHERE TOP

WALL PLATE MEETS EXISTING STEEL. PATCH ANY FIREPROOFING DISTURBED BY CONSTRUCTION

ACTIVITIES WITH NEW FIRE PROOFING MATCHING EXISTING SYSTEM.

• AN INTERIM PLASTIC DUST BARRIER (MINIMUM 6-MIL THICKNESS) SHALL BE INSTALLED TO PROTECT ADJACENT AREAS WHILE THE IMPERVIOUS (1-HR. RATED) DUST PARTITION IS BEING

CONSTRUCTED.

d. ANY DUST GENERATED FROM DEMOLITION OR CONSTRUCTION ACTIVITIES SHALL BE IMMEDIATELY

CLEANED IF TRACKED OR FOUND OUTSIDE OF THE CONSTRUCTION PHASE PERIMETER.

e. CONTRACTOR PERSONNEL SHALL MONITOR DUST PARTITION CONDITION AND PERFORM

MAINTENANCE - DURING PHASED DEMOLITION AND CONSTRUCTION ACTIVITIES.

f. UPON COMPLETION OF CONSTRUCTION ACTIVITIES, DUST PARTITIONS SHALL BE CAREFULLY

REMOVED TO MINIMIZE THE SPREAD OF DUST.

• CONTRACTOR SHALL INSTALL INTERIM PLASTIC DUST BARRIERS (MINIMUM 6-MIL THICKNESS)

PRIOR TO THE REMOVAL OF DUST PARTITIONS.

g. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY PARTITION LAYOUT. LAYOUT SHALL NOT

INTERFERE WITH HOSPITAL OPERATION.

I. TRAFFIC CONTROL:

a. PHASED SITE ACCESS SHALL HAVE DEFINED ENTRY AND EXIT PROCEDURES. EGRESS PATHS AND BE

FREE OF DEBRIS, TOOLS, EQUIPMENT, OR CONTAINERS.

b. DESIGNATED ELEVATORS SHALL ONLY BE USED DURING SCHEDULED TIME PERIODS AND ONLY

AUTHORIZED PERSONNEL SHALL BE ALLOWED TO ENTER THE CONSTRUCTION ZONE. COORDINATE

ELEVATOR ACCESS WITH THE VAMC THROUGH THE COR.

c. INSTALL SIGNAGE TO DIRECT PEDESTRIAN TRAFFIC AWAY FROM THE CONSTRUCTION AREAS.

J. DEMOLITION DEBRIS:

a. ALL DEBRIS GENERATED BY PROJECT SHALL BE REMOVED IN CARTS WITH TIGHTLY FITTING COVERS, USING DESIGNATED TRAFFIC ROUTES. EFFORTS SHALL BE MADE TO MINIMIZE THE USE OF

ELEVATORS SHARED BY PATIENTS OR STAFF. PERFORM TRANSPORT OF DEBRIS AT TIMES DIRECTED

BY THE VAMC THROUGH THE COR. IF EXTERIOR TRASH CHUTES ARE USED TO DIRECT DEBRIS

OUTSIDE, HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTERED NEGATIVE AIR MACHINES SHALL BE USED AND THE CHUTE OPENING SEALED WHEN NOT IN USE. USED FILTERS SHALL BE BAGGED AND SEALED BEFORE TRANSPORTING OUT OF THE CONSTRUCTION AREA. THE CONTRACTOR SHALL NOT

HAUL DEBRIS THROUGH PATIENT-CARE AREAS WITHOUT PRIOR APPROVAL OF THE VAMC.

K. VENTILATION AND ENVIRONMENTAL CONTROLS:

a. AIR SYSTEM FLOW: DETERMINE IF CONSTRUCTION AREA USES FRESH/OUTSIDE OR RECIRCULATED

AIR. ADD FILTERS AND/OR COVER RETURN GRILLS WITH FILTER MATERIAL OR PLASTIC. AIR MUST

(ONLY) FLOW IN THE DIRECTION OF CLEAN AREAS TO DIRTY AREAS.

b. NEGATIVE AIR PRESSURE: AIR WITHIN THE CONSTRUCTION AREAS (PHASES) MUST BE MAINTAINED AT NEGATIVE PRESSURE WITH RESPECT TO SURROUNDING AREAS. NO DISRUPTION OF AIR SYSTEMS OF ADJACENT AREAS IS ALLOWED DURING PERIODS OF VAMC OCCUPANCY OF ADJACENT AREAS. THE

NEGATIVE AIR PRESSURE SYSTEM WITHIN THE ENCLOSED PHASES SHALL EXHAUST DIRECTLY

OUTSIDE.

• DUST PARTITIONS SHALL BE OUTFITTED WITH CONTINUOUS AIR PRESSURE MONITORING

DEVICES WITH 24/7 READ OUT AND LOGGING. BASIS OF DESIGN FOR AIR PRESSURE MONITORING

DEVICE IS PHOENIX CONTROLS APM II, OR EQUAL.

L. WORKSITE CLOTHING AND CLEANING:

a. CONTRACTOR PERSONNEL CLOTHING SHALL BE FREE OF LOOSE SOIL AND DEBRIS BEFORE

ENTERING OR LEAVING THE CONSTRUCTION AREA. IF PROTECTIVE APPAREL IS NOT WORN (E.G.

COVERALLS, FOOTGEAR, AND HEADGEAR) A HEPA-FILTERED VACUUM SHALL BE USED TO REMOVE

DUST FROM CLOTHING BEFORE LEAVING THE PHASED CONSTRUCTION AREA. IF PROTECTIVE

APPAREL IS UTILIZED, THE CONTRACTOR SHALL CONSTRUCT A SPACE AS AN ANTEROOM FOR

CHANGING CLOTHING AND STORING EQUIPMENT.

b. ALL EQUIPMENT, TOOLS, CARS, MATERIALS, ETC. TRANSPORTED THROUGH NORMALLY OCCUPIED

AREAS SHALL BE MADE FREE FROM DUST AND MOISTURE BY VACUUMING AND WET MOPPING

BEFORE THEIR REMOVAL FROM THE CONSTRUCTION ZONE OR WORK AREA.

c. THE CONSTRUCTION ZONE MUST BE MAINTAINED IN A CLEAN MANNER BY CONTRACTORS. SWEEP OR HEPA-VACUUM CONSTRUCTION AREA DAILY - OR MORE FREQUENTLY AS NEEDED TO MINIMIZE DUST.

ADJACENT AREAS IMPACTED BY CONSTRUCTION SHOULD BE DAMP MOPPED DAILY OR MORE

FREQUENTLY AS NEEDED. WALK-OFF MATS WITH TACKY OR ADHESIVE SURFACES SHOULD BE

UTILIZED TO MINIMIZE TRACKING OF DIRT AND DUST FROM CONSTRUCTION AREAS.

GENERAL INFECTION AND DUST CONTROL NOTES

PROJECT SCOPE

17.2 17.2

15.1 15.1

D.2

D.2

F.1

F.1

G.2

G.2

OR-7

B-408

OR-6

B-406

HISTO LAB

B-405

CORRIDOR

C-1 CORRIDOR

C-2

ATTENDING PHYS LOUNGE

B-410

SUB-STERILE RM

B-407

17.2 17.2

15.1 15.1

D.2

D.2

F.1

F.1

G.2

G.2

OR-7

B-408

OR-6

B-406

HISTO LAB

B-405

CORRIDOR

C-1 CORRIDOR

C-2

ATTENDING PHYS LOUNGE

B-410

SUB-STERILE RM

B-407

ROOM ELEVATION

POST ICRA, ILSM, FIRE

INSPECTION SHEETS VISIBLE

TO PUBLIC

SUSPENDED PLASTIC ZIPPER WALL

CURTAIN BARRIER

A P

P R

O X

A

.F .F

INDICATOR MUST BE AT -0.01 OR GREATER (VERIFY

DAILY), IF NOT VERIFY ALL OPENINGS, SUCH AS DOORS,

ARE CLOSED AND/OR CHANGE OUT NEGATIVE AIR PRE-

FILTER.

INDICATOR (REFER TO PLAN

& ELEVATION)

FRAMED PICTURE OF

C.O.R. WITH CONTACT

INFO

CONST. SUPERVISOR

NAME AND CELL

PHONE

CHILLER PLANT AFTER HOURS

CONTACT PHONE NUMBER FIRE

EMERGENCY DIAL 911

COMING SOON!!!

- DESCRIPTION OF NEWLY PROPOSED OCCUPANCY -

PERSONNEL ENTERING MUST HAVE: HARD HAT, SAFETY GLASSES

AND PROPER I.D.

THIS IS A

RESTRICTED AREA

AREA UNDER CONSTRUCTION

PAPER CADDY

ICRA, ILSM, FIRE WATCH,

MISC. FORMS

FRAMED COPY OF C.O.R.

CERTIFICATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

T-691

C U s e rs

\c a rt e \D o c u m e n ts

\0

L o c a l R e v it F ile s \2

\F F

E

L o u is v ill e

R e s to re A

H U

-1

M E

P c a rt e r.

d a n ie l0

.r v t

/3

/2

:2

:5

A

M

GI002

ICRA PLANS

Owner

08/12/2021 PQ CD

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

CONSTRUCTION

DOCUMENTS (100%) 1

ROBLEY REX

VA MEDICAL

CENTER

KEY PLAN - FOURTH FLOOR

1/4" = 1'-0"

FOURTH FLOOR ICRA PLAN - OR 6

1/4" = 1'-0"

FOURTH FLOOR ICRA PLAN - OR 7

D R A W I N G N O T E S :

1 SEAL DOOR IN CLOSED POSITION DURING WORK ACTIVITIES.

2 CONTRACTOR TO VERIFY O.R. DEMISING WALL EXTENDS ABOVE CEILING TO STRUCTURE ABOVE WITH METAL FRAMING AND GYPSUM BOARD. SEAL AS REQUIRED TO PREVENT AIR INFILTRATION. (TYPICAL AT EACH O.R.)

3 EXTEND FLEXIBLE DUCT FROM HEPA CART TO WINDOW IN CORRIDOR C-1. DUCT SHALL BE TIGHT TO CEILING AND DOOR FRAMES THROUGH ENTIRE RUN. VERIFY SEALANT AT DUCT PENETRATIONS THROUGH TEMPORARY WALL

CONSTRUCTION AND AT TEMPORARY WINDOW INFILL PANEL MEETS ICRA REQUIREMENTS.

4 EXTEND WALL TO STRUCTURE AS NECESSARY TO MEET INFECTION AND DUST CONTROL REQUIREMENTS AS

DEFINED IN THE GENERAL ICRA NOTES.

5 AIR PRESSURE MONITOR LOCATION. NEGATIVE AIR PRESSURE REQUIRED DURING ALL INTERIOR CONSTRUCTION

ACTIVITIES. REFER TO ELEVATION ON GI002 FOR REQUIREMENTS.

6 PROVIDE TEMPORARY ICRA RATED VESTIBULE AS NECESSARY TO MAINTAIN NEGATIVE PRESSURE IN SCOPE OF

WORK.

7 DISASSEMBLE WINDOW AS NECESSARY FOR TEMPORARY VENT CONSTRUCTION. USE NON-POROUS MATERIAL

TO INFILL WINDOW FOR TEMPORARY CONSTRUCTION.

8 MAINTAIN OPEN DOOR DURING CONSTRUCTION.

9 MAINTAIN ACCESS TO HISTO LAB DURING CONSTRUCTION.

10 PROVIDE TEMPORARY PLASTIC SHEETING AS NECESSARY FOR ICRA BARRIER INSTALLATION.

N N

4 BID DOCUMENTS 08/10/2021

DUMBWAITER

DUMBWAITER

DUMBWAITER

DUMBWAITER

FAC

FAC

FAC

FAC

STORAGE

A-458A

PATIENT

RESTROOM

A-467A

PATIENT

RESTROOM

A-480A

ELECTRICAL

CLOSET

B-413C

STORAGE

A-477

NURSE

CALL

EQUIP

A-454

TELEPHONE

CLOSET

A-455

ELECTRICAL

CLOSET

A-456

ALCOVE

MULTIPURPOSE RM

A-448

STAIR

NO

MENS

LOCKER RM

B-401

PATIENT

RESTROOM

A-466A

TOILET

B-425A

CORRIDOR

HISTO

LAB

B-405

ATTENDING

PHYS LOUNGE

B-410

HVAC

EQUIP RM

A-443

PATIENT

BED RM

A-466

SCRUB

C-403

CLEAN

UTILITY

B-427

CORRIDOR CORRIDOR

PATIENT

BED RM

A-469

PATIENT

BED RM

A-475

STORAGE

A-433

ELEVATOR

S-6

ELEVATOR

S-5

ELEVATOR

P4

ELEVATOR

P3

PIPE

CHASE

A-453D

CHIEF

SURGY SVC

A-453C

HAC

A-452

SECY SURGY

SVC

A-453A

AA SURGY

SVC

A-453B

SURGY

SVCS

A-453

ELEVATOR

P2

ELEVATOR

P1

CORRIDOR

CORRIDOR

CORRIDOR

ASU

B-413

WAITING/

RECEPTION

B-413B

TOILET

B-413B

CONSULT

B-420

ELEVATOR

P-9

ELEVATOR

P-8

ELEVATOR

P-7

LOBBY

B-419

ELECTRICAL

B-418

SUPPLY

B-413D

DARK RM

B-421A

MEDICATION

B-423A

STAIR-3

B-421

HOLDING

RM

B-423

INSTRUMENT

PREP

C-415A

CYSTOSCOPY

B-425

EQUIP

C-415A1

SUB-STERILE

B-424

CYSTOSCOPY

C-415

EQUIPMENT

C-414

STORAGE

C-413

HAC

C-412

MENS

RESTROOM

C-411

WOMENS

RESTROOM

C-410

SOILED

UTILITY

B-426

PACU

RECOVERY

B-429

STAIR-5

B-428

EQUIP

STORAGE

C-409

OR-1

C-408

SUB-STERILE

C-406A

SCRUB

C-407

OR-2

C-406

ANEST

WORK RM

C-405

OR-3

C-404

SUB-STERILE

C-402A

OR-4

C-402

EQUIP

STORAGE

C-401

OR-5

(ORTHOPEDIC)

B-417

EQ

STORAGE

RM

B-416

SUB-STERILE

B-415

BAY-1

BAY-2

BAY-3

BAY-4

BAY-5

ORSUPV

OFFICE

B-436

TELEPHONE RM

B-435A

CONTROL

DESK

B-440

ACNS

OFFICE

B-439

SUB-STERILE

RM

B-412

B-411A

STORAGE

B-411

ELEVATOR

SUB-STERILE

RM

B-407

STORAGE

B-408

OR-6

B-406

HAC

B-404

ELECTRICAL

CLOSET

B-403

MENS

DRESSING RM

B-402

CORRIDOR

OR

LOUNGE

B-438

SURGY

OFFICE

A-451

SURGY

OFFICE

A-450WOMENS

LOCKER RM

B-441

SURGICAL

STORAGE

A-449

WOMENS

RESTROOM

B-441A

DUMBWAITER

RM

A-447

B-401A

WOMENS

RESTROOM

A-445

MENS

RESTROOM

A-444

COMM

CLOSET

A-441

ELECTRICAL

CLOSET

A-440

STAIR-1

A-442

WAITING RM

A-439

SUB

STATION

A-437

CENTER

NUTRITION

A-435

ELECTRICAL

CLOSET

A-438

STAIR-2

A-434

MEDICINE

PREPARATION

RM

A-436

STAFF TOILET

A-432

PATIENT

BED RM

A-431

LINEN

A-430

ANTE

RM

A-429SUB

STATION

A-428

ELEVATOR

LOBBY

A-457

EQUIPMENT

B-435

ANEST

OFFICE

B-430

ANEST

OFFICE

B-431

A AND

MM

OFFICE

B-432

NSQIP

COORD

OFFICE

B-433

SURGY

OFFICE

B-434

CORRIDOR

NURSE

REPORT

A-461

RESTROOM

HAC

A-460

0FFICE

A-459

OFFICE

A-463A

STAFF LOCKER

A-462

NURSE STATION

A-463

STAFF

RESTRM

A-463B

MEDICATIONS

A-464

STAIR-6

A-465 PATIENT

BED RM

A-467

ALCOVE

A-468

PATIENT

RESTROOM

A-469A

PATIENT

RESTROOM

A-470A

PATIENT

BED RM

A-470

PATIENT

BED RM

A-471PATIENT

RESTROOM

A-471A

PATIENT

BED RM

A-472

ALCOVE

A-473

PATIENT

RESTROOM

A-472A

PATIENT

BED RM

A-474

PATIENT

RESTROOM

A-474A

PATIENT

RESTROOM

A-475A

SOILED

UTILITY

A-476

SUPPLY RM

A-478

PATIENT

BED RM

A-479

PATIENT

RESTROOM

A-479A

PATIENT

BED RM

A-480

PATIENT

BED RM

A-481

PATIENT

RESTROOM

A-481A

PATIENT

RESTROOM

A-482A

PATIENT

BED RM

A-482

PATIENT

BED RM

A-483

PATIENT

RESTROOM

A-483A

PATIENT

RESTROOM

A-484A

PATIENT

BED RM

A-484

PATIENT

BED RM

A-485

PATIENT

RESTROOM

A-485A

PATIENT

RESTROOM

A-486A

PATIENT BED RM

A-486

SOILED

UTILITY

A-487

NOURISHMENT

A-488

MECH RM

A-489STORAGE RM

A-490

WAITING RM

A-491

RESTROOM

A-400A

RESIDENTS

OFFICE

A-400

PATIENT

CHECK

IN/OUT

A-401

EXAM RM

A-402

EXAM RM

A-403

PATIENT

CONSULT

A-405ALCOVE

A-407

ELECTRICAL CLOSET

A-406

HVAC

EQUIP

A-408

PATIENT BED RM

A-409

ANTE RM

A-410

PATIENT

BED RM

A-411

OFFICE

A-412

A-414B

MENS

LOCKER RM

A-414A

HAC

A-413

MULTIPURPOSE RM

A-414

WOMENS

LOCKER RM

A-414c

ANTE RM

A-415

TOILET

A-414d

PATIENT

BED RM

A-416

HVAC

EQUIP RM

A-417

SOILED UTILITY RM

A-418

OFFICE

A-419

ANTE RM

A-420

PATIENT

BED RM

A-421

PATIENT

BED RM

A-422

ANTE

RM

A-403

PATIENT

BED RM

A-424

PATIENT

BED RM

A-425

ANTE

RM

A-426

A-427

LIGHT RM

B-422

FAC

CORRIDOR

TOILET

UP

DN

UP

UP

UP

TOILET

DUMBWAITER

B-413A

ZONE 04-3

ZONE 00-2

EXISTING HEALTHCARE

FULLY SPRINKLED

7,266 SQ FT

ZONE 04-1

EXISTING HEALTHCARE

FULLY SPRINKLED

7,882 SQ FT

ZONE 04-2

EXISTING HEALTHCARE

FULLY SPRINKLED

8,069 SQ FT

ZONE 04-4

EXISTING HEALTHCARE

FULLY SPRINKLED

21,133 SQ FT

ZONE 04-4

EXISTING HEALTHCARE

FULLY SPRINKLED

21,133 SQ FT

F

F

F

F

F

F

F

4 NORTH4 SOUTH

RE

CO

VE

RY

RECOVERY/OR

PATIENT

BED RM

FOURTH FLOOR PLAN

BUILDING 1

FULLY SPRINKLERED; MIXED RESPONSE TYPE

HEALTHCARE OCCUPANCY

FOURTH FLOOR PLAN

BUILDING 1

G003 7 16

Office of

Construction and Facilities

Management

Project NumberProject Title

Location

Date Checked Drawn

Drawing Number

Dwg. of

Approved: Project Director

Drawing Title

ENGINEERS

Date Revisions

Building Number

SITE NAME/ADDRESS

NUMBER

DRAFT SOC 10/26/2018

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317)486-5188

FIRE PROTECTION & CODE

V09-18-101

LOUISVILLE, KY

LOUISVILLE VAMC

STATEMENT OF CONDITIONS

Life Safety Assessment

KWAF12-28-2018

FP&C PROJECT #: 1937.10

FINAL SOC 12/28/2018

SYMBOLS LIST

HORIZONTAL EXIT PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

EW

FAAP

FACP

FIRE EXTINGUISHER

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM STATION

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR PANEL

AUTOMATED EXTERNAL DEFIBRILLATOR

F

AED

EYEWASH STATION

SPRINKLER SYSTEM RISER

SS SHOWER STATION

EVACUATION CHAIREVC

HE

EX

EP

TC

FHV FIRE HOSE VALVE

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

LC

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE

EXIT NUMBER

FOR REFERENCE ONLY

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

FIRE PROTECTION & CODE CONSULTANTS

AutoCAD SHX Text Robley Rex VA Medical Center

AutoCAD SHX Text Louisville, KY 40206

AutoCAD SHX Text 800 Zorn Avenue

AutoCAD SHX Text 6,759 Sq. Ft.

AutoCAD SHX Text

AutoCAD SHX Text

4 SOUTH SUITE

AutoCAD SHX Text

PATIENT CARE

AutoCAD SHX Text

WITH SLEEPING

AutoCAD SHX Text 8,291 Sq. Ft.

AutoCAD SHX Text

AutoCAD SHX Text

OR SUITE

AutoCAD SHX Text

NON SLEEPING

AutoCAD SHX Text

PATIENT CARE

AutoCAD SHX Text 1,856 Sq. Ft.

AutoCAD SHX Text

AutoCAD SHX Text

ASU SUITE

AutoCAD SHX Text

NON SLEEPING

AutoCAD SHX Text

PATIENT CARE

AutoCAD SHX Text 4,570 Sq. Ft.

AutoCAD SHX Text

AutoCAD SHX Text

OR 6 SUITE

AutoCAD SHX Text

NON-PATIENT CARE

D

DD

D

I

I

18.1 18.1

17.2

15.1

D.2

D.2

F.1

F.1

G.2

G.2 H.3

H.3

OR-7

B-408

SUB-STERILE RM

B-407

CORRIDOR

C-1 CORRIDOR

C-2

WORK RM

B-411

HVAC EQUIP RM

B-411A

ATTENDING PHYS LOUNGE

B-410

BAY-5

BAY-4

OR-6

B-406

HISTO LAB

B-405

PHASE 1 PHASE 2

G E N E R A L N O T E S

A. REFER TO GI001 FOR DEMOLITION AND NEW WORK GENERAL NOTES

B. DOCUMENT LOCATION OF LIGHT FIXTURES, SURGERY BOOMS, STERIS SURGERY LIGHTS, ACCESS PANELS, OUTLETS, SPRINKLERS, AND OTHER CEILING ELEMENTS PRIOR TO DEMOLITION OF CEILING. THE SAME

LAYOUT MUST BE REPLICATED IN THE NEW WORK.

C. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR DEVICE REMOVAL AND REINSTALLATION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF WALL OR TO CENTERLINE OF EQUIPMENT. ALL EXISTING DIMENSIONS ARE PLUS-OR-MINUS (±) CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SPACES PRIOR TO

START OF WORK.

PROJECT SCOPE

REFLECTED CEILING PLAN LEGEND

1' x 4' FIXTURE. UPPERCASE INDICATES TYPE PER THE FIXTURE SCHEDULE. LOWER CASE LETTER "a" INDICATES SWITCH ZONE.

OS

LC#

2' x 4' FIXTURE.

WALL MOUNTED FIXTURE.

INDUSTRIAL FIXTURE.

WALL MOUNTED FIXTURE.

EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED

RECESSED FIXTURE, DOWNLIGHT

CEILING MOUNTED OCCUPANCY SENSOR

LIGHTING CONTROLLER

2' x 2' FIXTURE.

A1 a

2' x 4' FIXTURE. SOLID FILL INDICATES FIXTURE ON LIFE

SAFETY OR EMERGENCY CIRCUIT.

(WHERE GENERATOR POWER IS NOT AVAILABLE

PROVIDE A UNIT BATTERY AT 1400 LM)

2' x 4' FIXTURE. DIAGONAL FILL INDICATES FIXTURE ON

CRITICAL CIRCUIT.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

T-691

C U s e rs

\c a rt e \D o c u m e n ts

\0

L o c a l R e v it F ile s \2

\F F

E

L o u is v ill e

R e s to re A

H U

-1

M E

P c a rt e r.

d a n ie l0

.r v t

/3

/2

:2

:4

A

M

AD144

FOURTH FLOOR DEMOLITION

REFLECTED CEILING PLAN

Owner

08/12/2021 PQ CD

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

CONSTRUCTION

DOCUMENTS (100%) 1

ROBLEY REX

VA MEDICAL

CENTER

1/4" = 1'-0"

FOURTH FLOOR DEMOLITION REFLECTED CEILING PLAN

D R A W I N G N O T E S :

1 REMOVE GYPSUM BOARD CEILING AND ASSOCIATED SUPPORT SYSTEM UP TO STRUCTURE. COORDINATE ACCESSORY AND

DEVICE REMOVAL WITH MECHANICAL AND ELECTRICAL DRAWINGS.

2 PROTECT EXISTING MEDICAL BOOM AND MOUNT DURING CONSTRUCTION. PROTECT STRUCTURAL SUPPORTS TO DECK ABOVE.

3 REMOVE, SALVAGE, STORE AND REINSTALL EXISTING ACCESS PANEL.

4 REMOVE UNUSED SURGICAL MOUNT AND ASSOCIATED STRUCTURAL SUPPORT STEEL FROM CEILING.

5 REMOVE EXISTING AIR DEVICE.

6 SINGLE SUSPENSION, DUAL SURGERY LIGHTHEAD TO REMAIN AND BE PROTECTED DURING CEILING REPLACEMENT.

7 EXISTING SURGERY LIGHTHEAD TO REMAIN AND BE PROTECTED DURING CEILING REPLACEMENT.

KEY PLAN - FOURTH FLOOR

N

N

T

M

T M

I

I

18.1 18.1

17.2

15.1

D.2

D.2

F.1

F.1

G.2

G.2 H.3

H.3

OR-7

B-408

SUB-STERILE RM

B-407

CORRIDOR

C-1 CORRIDOR

C-2

WORK RM

B-411

HVAC EQUIP RM

B-411A

ATTENDING PHYS LOUNGE

B-410

BAY-5

BAY-4

OR-6

B-406

HISTO LAB

B-405

9' - 1"

9' - 1"

/8

/8

19' - 9" ± 19' - 2" ±

4' - 3 7/8"

/8

4' - 10 1/8" ±

2' - 2 1/4" 2' - 3 7/8"

/8

/4

9' - 3 7/8"

/4

7' - 0"

PHASE 1 PHASE 2

G E N E R A L N O T E S

A. REFER TO GI001 FOR DEMOLITION AND NEW WORK GENERAL NOTES

B. DOCUMENT LOCATION OF LIGHT FIXTURES, SURGERY BOOMS, STERIS SURGERY LIGHTS, ACCESS PANELS, OUTLETS, SPRINKLERS, AND OTHER CEILING ELEMENTS PRIOR TO DEMOLITION OF CEILING. THE SAME

LAYOUT MUST BE REPLICATED IN THE NEW WORK.

C. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR DEVICE REMOVAL AND REINSTALLATION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF WALL OR TO CENTERLINE OF EQUIPMENT. ALL EXISTING DIMENSIONS ARE PLUS-OR-MINUS (±) CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SPACES PRIOR TO

START OF WORK.

PROJECT SCOPE

REFLECTED CEILING PLAN LEGEND

1' x 4' FIXTURE. UPPERCASE INDICATES TYPE PER THE FIXTURE SCHEDULE. LOWER CASE LETTER "a" INDICATES SWITCH ZONE.

OS

LC#

2' x 4' FIXTURE.

WALL MOUNTED FIXTURE.

INDUSTRIAL FIXTURE.

WALL MOUNTED FIXTURE.

EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED

RECESSED FIXTURE, DOWNLIGHT

CEILING MOUNTED OCCUPANCY SENSOR

LIGHTING CONTROLLER

2' x 2' FIXTURE.

A1 a

2' x 4' FIXTURE. SOLID FILL INDICATES FIXTURE ON LIFE

SAFETY OR EMERGENCY CIRCUIT.

(WHERE GENERATOR POWER IS NOT AVAILABLE

PROVIDE A UNIT BATTERY AT 1400 LM)

2' x 4' FIXTURE. DIAGONAL FILL INDICATES FIXTURE ON

CRITICAL CIRCUIT.

HANGER WIRE BY OTHERS

JOINT PAPER TAPE

J-BEAD

ACOUSTICAL SEALANT AT PERIMETER

JOINTS, TYPICAL.

MOLDING ANGLE, SECURE TO WALL

WITH APROPRIATE FASTENER, TYPICAL.

DRYWALL SUSPENSION MAIN TEE

DRYWALL SUSPENSION CROSS TEE

SCREW GYPSUM BOARD INTO ANGLE MOLDING

GYPSUM BOARD PANEL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

T-691

C U s e rs

\c a rt e \D o c u m e n ts

\0

L o c a l R e v it F ile s \2

\F F

E

L o u is v ill e

R e s to re A

H U

-1

M E

P c a rt e r.

d a n ie l0

.r v t

/3

/2

:2

:5

A

M

AC144

FOURTH FLOOR REFLECTED

CEILING PLAN

Owner

08/12/2021 PQ CD

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

CONSTRUCTION

DOCUMENTS (100%) 1

ROBLEY REX

VA MEDICAL

CENTER

1/4" = 1'-0"

FOURTH FLOOR REFLECTED CEILING PLAN

D R A W I N G N O T E S :

1 PROVIDE GYPSUM WALLBOARD CEILING AT HEIGHT OF PREVIOUSLY DEMOLISHED CEILING. CEILING HEIGHTS NOTED TO BE VERIFIED BY CONTRACTOR BEFORE THE START OF WORK. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR

CEILING ACCESSORY AND DEVICE INSTALLATION.

2 INSTALL NEW STAINLESS STEEL ACCESS PANEL IN LOCATION OF PREVIOUS OPENING.

3 INSTALL SALVAGED STAINLESS STEEL ACCESS PANEL IN LOCATION OF ORIGINAL OPENING.

KEY PLAN - FOURTH FLOOR

N

N

3" = 1'-0"

TYPICAL CEILING CONSTRUCTION

A/E ARCHITECT / ENGINEER

AAV AUTOMATIC AIR VENT

AB AIR BLENDER

ACD AUTOMATIC CONTROL DAMPER, MODULATING

ACD-TP AUTOMATIC CONTROL DAMPER, TWO POSITION

AD ACCESS DOOR

AF AFTER FILTER

AFCV AIR FLOW CONTROL VALVE

AFF ABOVE FINISHED FLOOR

AFMS AIR FLOW MEASURING STATION

AFW AIR FOIL WHEEL (FAN)

AHU AIR-HANDLING UNIT

AMP AMPERE

AP ACCESS PANEL

APD AIR PRESSURE DROP

ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE

AS AIR SEPARATOR

ASHRAE AMERICAN SOCIETY OF HEATING REFRIGERATION AIR CONDITIONING ENGINEERS

ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS

AW AIR WASHER

AXF AXIAL FLOW

BD BUTTERFLY DAMPER

BDD BACKDRAFT DAMPER

BG BOTTOM GRILLE

BHP BRAKE HORSEPOWER

BIW BACKWARD INCLINED WHEEL (FAN)

BR BOTTOM REGISTER

BSC BIOLOGICAL SAFETY CABINETS

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

C CENTIGRADE (CELSIUS)

CAV CONSTANT AIR VOLUME

CC COOLING COIL

CCD COOLING COIL CONDENSATE DRAIN

CD CEILING DIFFUSER

CD-1 CONSTRUCTION DOCUMENTS (SUBMISSION1)

CD-2 CONSTRUCTION DOCUMENTS (SUBMISSION2)

CENT CENTRIFICAL

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CFT CUBIC FEET

CG CEILING GRILLE

CHW CHILLER WATER

CI CAST IRON

CM CARBON MONOXIDE

CM CUBIC METER

CM/S CUBIC METER PER SECOND

CO2 CARBON DIOXODE

COP COEFFICIENT OF PERFORMANCE

COR CONTRACTING OFFICER REPRESENTATIVE

CR CEILING REGISTER

CUH CABINET UNIT HEATER

CV CONSTANT VOLUME

CW COLD WATER (POTABLE)

CWCC CHILLED WATER COOLING COIL

D DAMPER - AUTOMATIC

Db DRY-BULB TEMPERATURE

DB DECIBELS

DCW DOMESTIC COLD WATER

DD-1 DESIGN DEVELOPMENT (SUBMISSION 1)

DD-2 DESIGN DEVELOPMENT (SUBMISSION 2)

DDC DIRECT DIGITAL CONTROLS

DEG DEGREE

DF DIFFUSER

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER RETURN

DIA DIAMETER

DIW DEIONIZED WATER

DP DEW POINT TEMPERATURE

DP DIFFUSER PLATE

DPA DIFFERENTIAL PRESSURE ASSEMBLY

DPS DIFFERENTIAL PRESSURE SENSOR

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EC EVAPORATIVE COOLER

ECM ELECTRONICALLY COMMUTATED MOTOR

ECC ENGINEERING CONTROL CENTER

EDH ELECTRIC DUCT HEATER

EER ENERGY EFFICIENCY RATIO

EF EXHAUST FAN

EFF EFFICIENCY

EG EXHAUST GRILLE

EGS EMERGENCY GAS SHUTOFF

EGT ENTERING GLYCOL TEMPERATURE

EH EXHAUST HOOD

EJ EXPANSION JOINT

EMD END OF MAIN DRIP (STEAM)

ENT ENTERING

ER EXHAUST REGISTER

ERC ELECTRIC REHEAT COIL

ERP ELECTRIC RADIANT PANEL

ESP EXTERNAL STATIC PRESSURE

ET EXPANSION TANK

EUH ELECTRIC UNIT HEATER

EWT ENTERING WATER TEMPERATURE

EX EXISTING

ABBREVIATIONS

F FAHRENHEIT

F&T FLOAT AND THERMOSTATIC

F/SDPR COMBINATION FIRE SMOKE DAMPER

FA FREE AREA

FC FLEXIBLE CONNECTION

FCU FAN COIL UNIT (4 PIPE)

FCUC FAN COIL UNIT COOLING ONLY

FCUH FAN COIL UNIT HEATING ONLY

FCW FORWARD CURVED WHEEL (FAN)

FD FLOOR DRAIN

FD FIRE DAMPER

FE FLOW ELEMENT

FF FINAL FILTER

FPM FEET PER MINUTE

FPS FEET PER SECOND

FR FLOOR REGISTER

FS FLOW SWITCH

FSTAT FREEZESTAT

FT FEET

FT WC FEET OF WATER COLUMN

FT-LB FOOT-POUND

FTR FIN TUBE RADIATION

FV FACE VELOCITY

GA GAUGE

GAL GALLONS

GH GRAVITY HOOD

GPD GALLONS PER DAY

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GS GALVANIZED STEEL

H HUMIDIFER

HB HOSE BIBB

HC HEATING COIL

HEPA HIGH EFFICIENCY PARTICULATE AIR

HOA HAND/OFF/AUTOMATIC

HP HEAT PUMP

HP HORSEPOWER

HRC HEAT RECOVERY COIL

HRD HEAT RECOVERY DEVICE

HRW HEAT RECOVERY WHEEL

HSTAT HUMIDISTAT

HTM HUMIDIFIER TERMINAL

HUM HUMIDIFIER UNIT MOUNTED

HW HOT WATER

HWC HOT WATER COIL

HWHC HOT WATER HEATING COIL

HWP HEATING HOT WATER PUMP

HWR HEATING HOT WATER RETURN

HWS HEATING HOT WATER SUPPLY

HWUH HOT WATER UNIT HEATER

HZ HERTZ

I/O INPUT/OUTPUT

IAQ INDOOR AIR QUALITY

IBT INVERTED BUCKET TRAP

ICF IN-LINE CENTRIFUGAL FAN

ID INSIDE DIAMETER

IFB INTEGRAL FACE AND BYPASS

IN INCHES

IN HG INCHES OF MERCURY

IN WC INCH WATER COLUMN

IN WG INCH WATER GAUGE

IN-LB INCH-POUND

J INTENTIALLY LEFT BLANK

KG KILOGRAM

KG/HR KILOGRAM PER HOUR

kPa KILOPASCAL

KW KILOWATT

KWH KILOWATT HOUR

L LITER

L/h LITERS PER HOUR (or LITERS/HOUR) L/m LITERS PER MINUTE (or LITERS/MINUTE) L/s LITERS PER SECOND (or LITERS/SECOND)

LAT LEAVING AIR TEMPERATURE

LBS/HR POUNDS PER HOUR

LF LINEAR FOOT (FEET)

LGT LEAVING GLYCOL TEMPERATURE

LH LATENT HEAT

LSD LINEAR SLOT DIFFUSER

LTCP LOCAL TEMPERATURE CONTROL PANEL

LVG LEAVING

LVR LOUVER

LWT LEAVING WATER TEMPERATURE

M METER, SI UNIT

M/S METERS PER SECOND (OR METERS/SECOND)

MA MIXED AIR

MAT MIXED AIR TEMPERATURE

MAU MAKE-UP AIR UNIT

MAV MANUAL AIR VENT

MAX MAXIMUM

MB MIXING BOX

MBH 1,000 BTUH

MCA MINIMUM BRANCH CIRCUIT AMPACITY

MER MECHANICAL EQUIPMENT ROOM

MERV MINIMUM EFFICIENCY REPORTING VALUE

MHP MOTOR HORSEPOWER

MIN MINIMUM

MM MILLIMETER

MRI MAGNETIC RESONANCE IMAGING

MTD MEAN TEMPERATURE DIFFERENCE

MVD MANUAL VOLUME DAMPER

NA NOT APPLICABLE

NC NOISE CRITERIA

NC NORMALLY CLOSED

NO NORMALLY OPEN

NOM NOMINAL

NPLV NON-STANDARD PART LOAD VALUE

NPSH NET POSITIVE SUCTION HEAD

NPSHA NET POSITIVE SUCTION HEAD AVAILABLE

NPSHR NET POSITIVE SUCTION HEAD REQUIRED

NTS NOT TO SCALE

OA OUTSIDE AIR

OAD OUTDOOR AIR DAMPER

OAG OUTSIDE AIR GRILLE

OAI OUTSIDE AIR INTAKE

OD OUTSIDE DIAMETER

P PUMP

Pa PASCAL

PCF POUNDS PER CUBIC FOOT (FEET)

PD PRESSURE DROP

PF PRE-FILTER

PG PRESSURE GAGE

PGW PROPYLENE GLYCOL-WATER (SOLUTION)

PHC PREHEAT COIL

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH – ABSOLUTE

PSIG POUNDS PER SQUARE INCH – GAGE

R/E RETURN OR EXHAUST

RA RETURN AIR

RAD RETURN AIR DAMPER

RAT RETURN AIR TEMPERATURE

RDS ROOM DATA SHEETS

RH RELATIVE HUMIDITY

RHC REHEAT COIL

RLA RUN LOAD AMPERE

RPM REVOLUTIONS PER MINUTE

SA SUPPLY AIR

SAD SOUND ATTENUATING DEVICE

SAT SUPPLY AIR TEMPERATURE

SCFM STANDARD CUBIC FEET PER MINUTE

SCR SILICON CONTROLLED RECTIFIER

SD SMOKE DETECTOR

SD SUPPLY AIR DIFFUSER

SDPR SMOKE DAMPER

SEN SENSIBLE HEAT

SF SUPPLY FAN

SG SUPPLY AIR GRILLE

SH STEAM HUMIDIFIER

SHC STEAM HEATING COIL

SI SQUARE INCHES

SP STATIC PRESSURE

SP GR SPECIFIC GRAVITY

SPS STATIC PRESSURE SENSOR

SQ FT SQUARE FOOT (FEET)

SR SUPPLY AIR REGISTER

SS STAINLESS STEEL

TAB TESTING, ADJUSTING, BALANCE

TD TEMPERATURE DIFFERENCE

TG TRANSFER GRILLE

TR TOP REGISTER

TSP TOTAL STATIC PRESSURE

TSTAT THERMOSTAT

TU TERMINAL UNIT

TYP TYPICAL

UC UNDER CUT

UH UNIT HEATER

UL UNDERWRITERS LABORATORY

V VALVE

VAV VARIABLE AIR VOLUME

VD VOLUME DAMPER (MANUAL OPPOSED BLADE)

VFD VARIABLE FREQUENCY DRIVE

VHA VETERANS HEALTH ADMINISTRATION

VSD VARIABLE SPEED DRIVE

W WATTS

Wb WET-BULB (TEMPERATURE)

WFMD WATER FLOW MEASURING DEVICE

WG WATER GAGE

WPD WATER SIDE PRESSURE DROP

YR YEAR

M

H4

H7

A

COLD WATER (CITY WATER)

HOT WATER

QUICK-COUPLE HOSE CONNECTOR

PLUG VALVE

CONTROL VALVE (CV) - FLOAT-OPERATED

PRESSURE REDUCING VALVE (PRV)

WYE STRAINER WITH VALVED DRAIN AND QUICK-COUPLE

HOSE CONNECTOR

FLOW METER

DRAWING SYMBOLS

26-SF 3

26-TU-I-I

DETAIL NUMBER

DRAWING NUMBER WHERE SHOWN

SECTION LETTER

TYPICAL UNIT NO.

BUILDING NO. WHERE EQUIPMENT IS LOCATED.

SUPPLY FAN NO. 3 IN BUILDING NO. 26

EQUIPMENT ABBREVIATION (SUPPLY FAN)

ITEM NUMBER (TERMINAL UNIT NO. 1)

ITEM (TERMINAL UNIT SHOWN)

SERVED BY AIR HANDLER UNIT NO. 1

DRAWING NUMBER WHERE DRAWN

BUILDING NO. WHERE EQUIPMENT IS LOCATED

DUCTWORK SYMBOLS

LIMIT OF DEMOLITION

DN

DN

UP

UP

SUPPLY DUCT (UP & DOWN)

EXHAUST DUCT (UP & DOWN)

SQUARE 4-WAY CEILING DIFFUSERS

CONNECT NEW DUCT TO EXISTING DUCT

D

INCLINED RISE, IN DIRECTION OF AIR FLOW

INCLINED DROP, IN DIRECTION OF AIR FLOW

R

DNUP RETURN DUCT (UP & DOWN)

FC

10x8

FLEXIBLE CONNECTION, EQUIPMENT,

VIBRATION, OR SEISMIC

VANED ELBOW (PROVIDE ALL SQUARE OR

RECTANGULAR ELBOWS WITH VANES EVEN IF

SYMBOL IS MISSING)

VANED ELBOW (SHORT RADIUS)

STANDARD RADIUS ELBOW (LONG RADIUS)

NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)

EXISTING DUCT TO REMAIN

FIRE DAMPER

FD

FLEXIBLE DUCTWORK (INSULATED)

MANUAL VOLUME DAMPER

EXISTING DUCT TO BE REMOVED

2 1 POINT OF CHANGE IN DUCT CONSTRUCTION BY

STATIC PRESSURE CLASS. THE NUMBER ASSIGNS

PRESSURE CLASS (IN. OF WATER) WHICH WILL

ACCOMMODATE MAXIMUM OPERATING PRESSURE

IN THE DUCT SUBSECTION. THE SYMBOL CONTINUES

THE ASSIGNMENT UNTIL THE DUCT TERMINATES OR

ANOTHER SYMBOL APPEARS. A "N" SUPERSCRIPT

INDICATES NEGATIVE PRESSURE.

1/24

AUTOMATIC CONTROL DAMPER MODULATING

AUTOMATIC CONTROL DAMPER TWO POSITION

TERMINAL UNIT SYMBOLS

2'x2' RADIANT CEILING PANEL

UNIT HEATER (HORIZONTAL)

AIR TERMINAL SYMBOLS

DOUBLE DUCT MIXING BOX.

TERMINAL UNIT WITH REHEAT COIL

PIPING SYMBOLS

HIGH PRESSURE STEAM CONDENSATE RETURN

HIGH PRESSURE STEAM (60 PSIG AND ABOVE)

HOT WATER HEATING SUPPLY

LOW PRESSURE STEAM CONDENSATE RETURN

LOW PRESSURE STEAM (15 PSIG AND BELOW)

MEDIUM PRESSURE STEAM CONDENSATE RETURN

MEDIUM PRESSURE STEAM (16 PSIG THRU 59 PSIG)

VENT LINE

CHILLED WATER SUPPLY

CHILLED WATER RETURN

DRAIN LINE

HOT WATER HEATING RETURN

HPS

HPR

MPS

MPR

LPS

LPR

HWS

HWR

V

CHR

CHS

D

HW

CW

GENERAL PIPING SYMBOLS

ANCHOR

REDUCER OR INCREASER

DIRECTION OF FLOW

SIDE CONNECTION

ECCENTRIC REDUCER

BOTTOM CONNECTION, 45° OR 90°

TOP CONNECTION, 45° OR 90°

DIRECTION OF PIPE PITCH (DOWN)

UNION

RISE OR DROP IN PIPE

CAPPED OUTLET

PRESSURE GAGE

THERMOMETER

FLOW ELEMENTFE

PIPE UP

PIPE DOWN

REFRIGERANT SIGHT GLASS

TEST PLUG (PRESSURE/TEMPERATURE)

AUTOMATIC AIR VENT

AV

MANUAL AIR VENTMV

VALVE SYMBOLS

BALL VALVE

GATE VALVE WITH 3/4" HOSE ADAPTER

CHECK VALVE

ANGLE GLOBE VALVE

BUTTERFLY VALVE

MODULATING CONTROL VALVE

TWO POSITION CONTROL VALVE

THREE-WAY MODULATING CONTROL VALVE

AUTOMATIC BALANCING CONTROL VALVE

PRESSURE SAFETY VALVE

GATE VALVE - THREADED/FLANGED

GLOBE VALVE - THREADED/FLANGED

PRESSURE REGULATING VALVE

THREE-WAY TWO POSITION CONTROL VALVE

WYE STRAINER (WITH BALL VALVE & HOSE CONNECTION)

WATER BALANCE DEVICE

MODULATING CONTROL BUTTERFLY VALVE

CIRCUIT SETTER VALVE

CONTROLS SYMBOLS

T ROOM THERMOSTAT/TRANSMITTER - WALL MOUNT

TT TEMPERATURE TRANSMITTER

M ROOM HUMIDISTAT (MOISTURE)/TRANSMITTER - WALL MOUNT

MT MOISTURE (HUMIDITY) TRANSMITTER

PT PRESSURE TRANSMITTER

TT TEMPERATURE TRANSMITTER, AVERAGING ELEMENT

FT FLOW TRANSMITTER

IT CURRENT TRANSMITTER

SPS STATIC PRESSURE SENSOR

SD SMOKE DETECTOR

PDT PRESSURE DIFFERENTIAL TRANSMITTER

MG MAGNEHLIC PRESSURE GAUGE

PDS PRESSURE DIFFERENTIAL SWITCH

A

TEMPERATURE SENSING ELEMENT FOR

TRANSMITTING TEMPERATURE TO EMCS

(PROVIDE 12 INCHES [200mm] MINIMUM

LENGTH IN DUCT WHEN SPACE PERMITS.)

SENSOR WITH AVERAGING ELEMENT TO TRANSMIT

TEMPERATURE TO EMCS

MOTOR STARTER

M ELECTRIC OPERATED CONTROL DAMPER/OR VALVE

T

ES END SWITCH

(FC) FAIL CLOSED

(FO) FAIL OPEN

(FLP) FAIL LAST POSITION

T STEAM TRAP

CP CONDENSATE PUMP

GENERAL SYMBOLS

ACCESS PANEL

TERMINAL UNIT W/ REHEAT COIL AND AIR DEVICE

SD

SMOKE DETECTOR

HS HAND SWITCH (HAND-OFF-AUTO SWITCH)

NOTE:

ALL SYMBOLS AND ABBREVIATIONS ARE

SUBJECT TO MODIFICATIONS ON OTHER

DRAWINGS. ALL SYMBOLS OR ABBREVIATIONS

MIGHT NOT NECESSARILY BE USED ON THIS

PROJECT.

STAINLESS STEEL DUCT

AEROSOL DUCTSEALANTS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

T-691

C U s e rs

\j a c k v \D o c u m e n ts \F

F E

L o u is v ill e

R e s to re A

H U

-1

M E

P ja c k .v o lle tt e

.r v t

/2

/2

:4

:5

P

M

M001

MECHANICAL LEGEND

Owner

08/30/2021 KF KG

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

BID DOCUMENTSROBLEY REX

VA MEDICAL

CENTER

No. Revisions: Date:

0 BID DOCUMENTS 08/30/2021

08/27/2021

DN

UP

TT

I J K L M N O

12.1

O.2 Q.1 Q.3 R.1 R.2 R.3

16.1

17.1

18.1

17.2

15.1

D.2 F.1 G.2 H.3 I.1 I.2 K.1 L.1 L.2 L.3 N.1

2 2

(E)15"x10" EA(E)15"x10" EA

(E)24"x10" EA

(E)24"x10" EA

(E)12"x8" SA

(E)12"x6" SA

(E)34"x10" SA

(E)42"x12" SA

(E )4

6" x1

0" E

A (E

)3 0" x1 0"

E A

(E)12"x10" SA

(E)10"x8" SA (E)20"x10" EA

(E)20"x10" SA

(E)10"x8" SA

(E)20"x10" SA

(E )5

0" x1

0" E

A

(E)12"x10" SA

(E )6

0" x1

2" E

A

(E)40"x26" SA

(E)42"x12" SA

(E)16"x10" SA

(E)16"x10" SA

(E)28"x10" SA

(E)26"x10" EA

(E)20"x12" EA

(E)40"x14" EA

40"x18" EA (UP)

(E)48"x12" SA

(E)52"x12" SA

(E)20"x12" SA

(E)33"x12" SA

(E)32"x11" SA

(E)30"x12" EA

5 5

(E)42"x8" EA (E)26"x8" EA

1. REFER TO ARCHITECTURAL PLANS FOR PHASE IDENTIFICATION AND TEMPORARY BARRIER LOCATIONS.

2. THE AEROSEAL DUCT SEALANT WORK SHALL BE COMPLETED IN ONE WEEKEND TO ENSURE NORMAL OPERATING ROOM HOURS ARE NOT INTERRUPTED. COORDINATE WITH COR. CONTRACTOR SHALL MONITOR DUCTWORK FOR OVERSPRAY

AND SHALL BE RESPONSIBLE FOR CLEANING ANY INCIDENTAL OVERSPRAY.

PROJECT AREA OF WORK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

T-691

C U s e rs

\j a c k v \D o c u m e n ts \F

F E

L o u is v ill e

R e s to re A

H U

-1

M E

P ja c k .v o lle tt e

.r v t

/2

/2

:4

:0

P

M

MD104

MECHANCIAL FOURTH FLOOR

DEMOLITION

Owner

08/30/2021 KF KG

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

BID DOCUMENTS

ROBLEY REX

VA MEDICAL

CENTER

1/8" = 1'-0"

FOURTH FLOOR PLAN - HVAC DEMOLITION

N

D R A W I N G N O T E S :

1 CLEAN SUPPLY DUCTWORK (CROSS-HATCHED) ASSOCIATED WITH AHU-10 AND APPLY DUCT SEALANT PRODUCT BY AEROSEAL. EXISTING EXHAUST DUCTWORK IS SHOWN FOR COORDINATION AND TO REPRESENT A FULLY DUCTED

SYSTEM.

2 EXISTING DUCT MOUNTED REHEAT COIL TO REMAIN. REMOVE DUCTWORK LEADING TO HEATING COIL. CLEAN COIL AND REINSTALL DUCTWORK. IF DEDUCT ALTERNATE #2 IS ACCEPTED, DO NOT REMOVE DUCTWORK LEADING TO REHEAT COIL AND UTILIZE ACCESS PANEL TO CLEAN COIL. IF DEDUCT ALTERNATE #3 IS ACCEPTED, DO NOT PERFORM THIS

WORK.

3 REMOVE EXISTING DUCTWORK AND ASSOCIATED SUPPORTS, ACCESSORIES, ETC. TO THIS POINT. PREPARE FOR

RECONNECTION IN NEW WORK.

4 REMOVE EXISTING AIR DEVICE.

5 REMOVE EXISTING AIR DEVICE AND ITS ASSOCIATED DUCTWORK BACK TO MAIN. CAP AND SEAL AIRTIGHT.

P H A S I N G G E N E R A L N O T E S:

KEY PLAN - FOURTH FLOOR

No. Revisions: Date:

N O

O.2 Q.1 Q.3 R.1 R.2

16.1

17.1

18.1

N.1

AHU-10

(E)42"x24" SA (DN)

(E)24"x24" SA (DN)

(E)66"x20" OA (UP)

PROJECT SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

T-691

C U s e rs

\j a c k v \D o c u m e n ts \F

F E

L o u is v ill e

R e s to re A

H U

-1

M E

P ja c k .v o lle tt e

.r v t

/2

/2

:4

:0

P

M

MD105

MECHANICAL FIFTH FLOOR

DEMOLITION

Owner

08/30/2021 KF KG

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

BID DOCUMENTS

ROBLEY REX

VA MEDICAL

CENTER

1/4" = 1'-0"

FIFTH FLOOR PLAN - HVAC DEMOLITION

N

D R A W I N G N O T E S :

1 REMOVE EXISTING HOUSED FAN, BULKHEAD WALL, MOTOR, AND ALL ASSOCIATED CONTROLS, SUPPORTS AND ACCESSORIES. REMOVE BAS POINTS AND ALARMS ASSOCIATED WITH FAN AND VFD. IF DEDUCT ALTERNATE #1 IS ACCEPTED, DO NOT REMOVE THE EXISTING HOUSED FAN AND RE-BALANCE TO FAN TO THE NEW AIRFLOWS SPECIFIED.

2 REMOVE EXISTING HEPA FILTER FROM AHU-10.

No. Revisions: Date:

DN

UP

TTT

M

T M

I J K L M N O

12.1

O.2 Q.1 Q.3 R.1 R.2 R.3

16.1

17.1

18.1

O.1

17.2

15.1

D.2 F.1 G.2

H.3 I.1 I.2 K.1 L.1 L.2 L.3 N.1

ANESTHESIA PHYSICIAN'S

OFFICE

B-431

ANESTHESIA ATTENDING

B-430

SD-2

600 CFM

SD-2

600 CFM

SD-2

515 CFM

OR-7

B-408

OR-6

B-406

SD-2

515 CFM

18"x8" SA

14"x8" SA

14"x8" SA

18"x8" SA

(E )2

4" x8

S

A

(E )2

4" x8

S

A

(E)20"x12" SA

(E)30"x12" SA

(E)33"x12" SA (E)48"x12" SA

(E)60"x12" EA

(E)50"x10" EA

(E)46"x10" EA

(E)30"x10" EA

(E)40"x26" SA (E)40"x26" SA

(E)42"x24" SA (UP)

(E)24"x24" SA (UP)

(E)20"x20" SA

(E)32"x11" SA

(E)40"x14" EA

(E)20"x26" SA

(E)52"x12" SA

(E)42"x12" SA

(E)20"x10" SA

(E)12"x10" SA

(E)20"x10" SA

(E)10"x8" SA

(E)10"x8" SA

(E)34"x10" SA

(E)28"x10" SA

(E)16"x10" SA

(E)24"x10" EA

(E)24"x10" EA

(E)12"x6" SA(E)12"x8" SA

(E)16"x10" SA

(E)12"x10" SA

(E)42"x8" EA

SPS

SPS

A AND MM OFFICE

B-432

SD-1

265 CFM

265 CFM

85 CFM

655 CFM

80 CFM

15 CFM

130 CFM

130 CFM

130 CFM

130 CFM

140 CFM

140 CFM

130 CFM

65 CFM

140 CFM

145 CFM

65 CFM

225 CFM

385 CFM

385 CFM

380 CFM

380 CFM

255 CFM

75 CFM

75 CFM

385 CFM

120 CFM

60 CFM

SUB-STERILE RM

B-412

LIGHT RM

B-422

DARK RM

B-421A

ATTENDING PHYS LOUNGE

B-410

ASU

B-413

WAITING / RECEPTION

B-413B

CONSULT

B-420

SUB-STERILE

B-415

CORRIDOR

C-5

OR-5 (ORTHOPEDIC)

B-417

HISTO LAB

B-405

CORRIDOR

C-1

SUB-STERILE RM

B-407

CORRIDOR

C-2

WORK RM

B-411

ACNS OFFICE

B-439

CORRIDOR

C-4

OR LOUNGE

B-438

20 CFM

80 CFM

75 CFM

150 CFM(E)30"x12" EA

(E)60"x12" EA

(E)48"x12" SA

(E)42"x12" SA

665 CFM

665 CFM

(E)36"x24" EA

(E)10"x15" EA

(E)26"x10" EA

(E)26"x8" EA (E)24"x26" SA

SURGY OFFICE

A-451

CORRIDOR

C-2

ELECTRICAL CLOSET

B-403

HAC

B-404

SURGY OFFICE

A-450

WOMEN'S LOCKER RM

B-441

CORRIDOR

C-3 OR SUPERVISOR / DICTATION

B-436

CONSULT RM

B-435

SURGY OFFICE

B-434

NSQIP COORD OFFICE

B-433

HOLDING RM

B-423

CYSTOSCOPY

B-425 CLEAN UTILITY

B-427

PACU RECOVERY

B-429

STAIR-3

B-421

BAY-1

BAY-2

BAY-3

BAY-4

TOILET

B-413B

EQ STORAGE RM

B-416

EQUIP STORAGE

C-401

(4 GPM) (3 GPM)

EG-2

1265 CFM

EG-1

830 CFM

1. REFER TO ARCHITECTURAL PLANS FOR PHASE IDENTIFICATION AND TEMPORARY BARRIER LOCATIONS.

2. THE AEROSEAL DUCT SEALANT WORK SHALL BE COMPLETED IN ONE WEEKEND TO ENSURE NORMAL OPERATING ROOM HOURS ARE NOT INTERRUPTED. COORDINATE WITH COR. CONTRACTOR SHALL MONITOR DUCTWORK FOR OVERSPRAY

AND SHALL BE RESPONSIBLE FOR CLEANING ANY INCIDENTAL OVERSPRAY.

PROJECT AREA OF WORK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

T-691

C U s e rs

\j a c k v \D o c u m e n ts \F

F E

L o u is v ill e

R e s to re A

H U

-1

M E

P ja c k .v o lle tt e

.r v t

/2

/2

:4

:5

P

M

M104

MECHANICAL FOURTH FLOOR

PLAN NEW WORK

Owner

08/30/2021 KF KG

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

BID DOCUMENTS

ROBLEY REX

VA MEDICAL

CENTER

1/8" = 1'-0"

FOURTH FLOOR PLAN - HVAC NEW WORK

D R A W I N G N O T E S :

1 REPLACE EXISTING PNEUMATIC HEATING HOT WATER CONTROL VALVE WITH NEW DDC CONTROLS. INTEGRATE NEW CONTROLLER INTO THE CURRENT BUILDING CONTROL SYSTEM. BALANCE TO GPM INDICATED. REMOVE PNEUMATIC

THERMOSTAT AND TUBING FROM VALVE AND CAP MAIN AIR SUPPLY SERVING VALVE ACTUATOR.

2 PROVIDE NEW DUCT STATIC PRESSURE SENSOR TO CONTROL NEW SUPPLY FAN ARRAY.

3 REBALANCE EXISTING DIFFUSER TO CFM INDICATED.

4 PROVIDE NEW TEMPERATURE AND HUMIDITY SENSORS CONNECTED TO BAS SYSTEM.

P H A S I N G G E N E R A L N O T E S:

N

KEY PLAN - FOURTH FLOOR

No. Revisions: Date:

08/27/202108/27/2021

O.2 Q.1 Q.3 R.1 R.2

16.1

17.1

18.1

N.1

AHU-10

SF-10

PROJECT SCOPE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

T-691

C U s e rs

\j a c k v \D o c u m e n ts \F

F E

L o u is v ill e

R e s to re A

H U

-1

M E

P ja c k .v o lle tt e

.r v t

/2

/2

:4

:5

P

M

M105

MECHANICAL FIFTH FLOOR PLAN

NEW WORK

Owner

08/30/2021 KF KG

RESTORE AHU-10 SYSTEM

(OR'S 5-7)

630-20-202

LOUISVILLE, KENTUCKY

BID DOCUMENTS

ROBLEY REX

VA MEDICAL

CENTER

1/4" = 1'-0"

FIFTH FLOOR PLAN - HVAC NEW WORK

D R A W I N G N O T E S :

1 CLEAN FIN FACE OF COOLING COIL, HOT WATER PREHEAT COIL, AND HEAT RECOVERY COIL.

2 INSTALL NEW ECM FAN ARRAY. FAN MANUFACTURER TO PROVIDE BULKHEAD WALL, CONTROL PANEL, AND ALL OTHER ACCESSORIES. CONTRACTOR TO COORDINATE INSTALLATION WITH FAN MANUFACTURER. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MODIFICATIONS TO THE EXISTING AIR HANDLING UNIT REQUIRED FOR FAN INSTALLATION.

PROVIDE BACNET IP GATEWAY IN CONTROL PANEL TO INTEGRATE WITH EXISTING BUILDING AUTOMATION SYSTEM. IF DEDUCT ALTERNATE #1 IS ACCEPTED, DO NOT INSTALL NEW ECM ARRAY OR CONTROLS MODIFICATIONS.

3 PROVIDE NEW FILTER FRAME AND MERV 14 FINAL FILTER.