N1197462 - Repair Building 1 and 1 A Roofs - Lexington VA Medical Center - Asbestos Survey Report 062920.pdf

PDF 3 MB Posted

Attached to
Y1DA--Project # 596A4-20-101 Construction to Repair Roofing Buildings 1 and 1A
Solicitation number
36C24921R0050
Issued by

About this file

This document is an asbestos survey report for the Lexington VA Medical Center project to repair rooftops on Buildings 1 and 1A. The survey was conducted to identify and locate asbestos-containing materials pertaining to the roofing materials on the specified buildings. Laboratory analysis confirmed that a black/silver roof coating material on the roof section of Building 1 contained asbestos. The report provides the location, percentage, and estimated quantity of asbestos present. It also outlines regulatory requirements for asbestos abatement under US OSHA standards and Kentucky state regulations. The related federal contract opportunity is for construction services to repair the rooftops on Buildings 1 and 1A at the Lexington VA Medical Center, as identified in asbestos survey report project number N1197462. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9.

View the file

Other files

File Type Posted
36C24921R0050 0004.docx DOCX document
Roof Composition Data.pdf PDF
36C24921R0050 0003.docx DOCX document
Solicitation Questions _ Answers - 36C24921R0050.pdf PDF
36C24921R0050 0002.docx DOCX document
Site Visit Sign-In.pdf PDF
36C24921R0050 0001.docx DOCX document
Past Performance Questionnaire.pdf PDF
Wage Determination KY20210090 01-15-2021.pdf PDF
Project Drawings.pdf PDF
36C24921R0050_1.docx DOCX document
Statement of Work.pdf PDF
Project Specifications.pdf PDF
Pricing Schedule.xlsx XLSX spreadsheet
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos Survey VA Project: Repair Roofing Building 1 and 1A

VA Project No: 596A4-20-101 Lexington VA Medical Center

1101 Veterans Drive Lexington, Fayette County, Kentucky 40502

June 29, 2020 Terracon Project No. N1197462

Prepared for:

FFE, Inc.

Cincinnati, Ohio

Prepared by:

Terracon Consultants, Inc.

Cincinnati, Ohio

Terracon Consul tants, Inc. 611 Lunken Park Dr ive Cincinnat i , OH 45226 P 513-321-5816 F 513-321-0294 terracon.com

June 29, 2020

FFE, Inc.

438 Springfield Pike, Suite C Cincinnati, Ohio 45215

Attn: Mr. Clint Weekley President T: (513) 519-5999 E: clint.weekley@ffe-serv.com

Re: Asbestos Survey Project: Repair Roofing Buildings 1 and 1A VA Project No.: 596A4-20-101 Lexington VA Medical Center 1101 Veterans Drive Lexington, KY 40502 Terracon Project No. N1197462

Dear Mr. Weekley, Terracon Consultants, Inc. (Terracon) is pleased to submit the attached report for the above-referenced project. The purpose of this report is to present the results of an asbestos survey which was performed on June 15 and 16, 2020 at the Lexington Medical Center (VAMC) located at 1101 Veterans Drive in Lexington, Kentucky. This survey was conducted in general accordance with the authorized proposal PN1197462, dated November 18, 2019. We understand that this survey was requested in order to identify and locate asbestos-containing materials (ACM) pertaining to the roofing materials on buildings 1 and 1A, which are slated for roof repair and/or replacement.

Asbestos (<1%) was identified by laboratory analysis in samples collected from one (1) material type. Please refer to the report for further detail.

We appreciate the opportunity to be of service to you on this project. If there are any questions regarding this report or if we may be of further assistance, please do not hesitate to contact us.

Sincerely, Terracon Consultants, Inc.

Josh Vogel Joseph A. Tussey, CHMM, MBA Project Manager Sr. Associate / Group Manager KY Asbestos Building Inspector

Responsive ■ Resourceful ■ Reliable

TABLE OF CONTENTS

1.0 INTRODUCTION

1.1 Reliance

2.0 PROJECT DESCRIPTION

3.0 FIELD ACTIVITIES

3.1 Visual Assessment

3.2 Physical Assessment

3.3 Sample Collection

3.4 Sample Analysis

4.0 REGULATORY OVERVIEW

5.0 FINDINGS and recommendations

6.0 LIMITATIONS/GENERAL COMMENTS

APPENDIX A IDENTIFIED ASBESTOS-CONTAINING MATERIALS BY HOMOGENEOUS AREA (HA)

APPENDIX B ABESTOS SURVEY SAMPLE SUMMARY

APPENDIX C ASBESTOS ANALYTICAL LABORATORY DATA

APPENDIX D LICENSES AND CERTIFICATIONS

APPENDIX E DIAGRAMS

APPENDIX F PHOTOGRAPHS

Responsive ■ Resourceful ■ Reliable 1

ASBESTOS SURVEY

Project: Repair Roofs Building 1 and 1A

VA Project No.: 596A4-20-101 Lexington VA Medical Center

1101 Veterans Drive Lexington, Fayette County, Kentucky

Terracon Project No. N1197462 June 29, 2020

1.0 INTRODUCTION

Terracon Consultants, Inc. (Terracon) conducted an asbestos survey in support of the buildings 1 and 1A roof repair project pertaining to the Lexington VA Medical Center (VAMC) located at 1101 Veterans Drive in Lexington, Kentucky. The survey was conducted on June 15 and 16, 2020, by a Kentucky-accredited asbestos management planner/inspector in general accordance with Terracon proposal number PN1197462, dated November 18, 2019. Accessible roof materials pertaining to buildings 1 and 1A were surveyed, and homogeneous areas (HA) of suspect asbestos-containing materials (ACM) were visually identified and documented. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials could be located in voids or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in United States Environmental Protection Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763 Subpart E 763, known as the Asbestos Hazard Emergency Response Act (AHERA). Samples were delivered to an accredited laboratory for analysis by Polarized Light Microscopy (PLM).

We understand this asbestos survey was requested due to a planned renovation project (roof repair and/or replacement) pertaining to the subject roofs to satisfy requirements of the USEPA 40 CFR Part 61, Subpart M, the National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation.

1.1 Reliance

This report is for the exclusive use of FFE, Inc. (Client) for the project being discussed. Reliance by any other party on this report is prohibited without written authorization of Terracon and the Client. Reliance on this report by FFE, Inc. and all authorized parties will be subject to the terms, conditions, and limitations stated in the proposal, this report, and the agreement between Terracon and the Client. The limitations of liability defined in the agreement is the aggregate limit of Terracon’s liability to the Client.

Repair Roofs Building 1 and 1A ■ Lexington VAMC June 29, 2020 ■ Terracon Project No. N1197462

Responsive ■ Resourceful ■ Reliable 2

2.0 PROJECT DESCRIPTION

The roofs of buildings 1 and 1 A are being considered for future replacement and/or repair.

Building 1 is comprised of 16 roof sections and Building 1A appears to be comprised of 7 (seven) roof sections (23 total roof sections). See Appendix E for roof section diagrams. Roof sections were given alphabetic letters for identification purposes for this survey.

3.0 FIELD ACTIVITIES

The survey was conducted by Mr. Michael Sulken, a Kentucky-accredited asbestos management planner/inspector. A copy of Mr. Sulken’s current state credential is attached as Appendix D. The survey was conducted in general accordance with the sample collection protocols established in USEPA 40 CFR Part 763, Subpart E (AHERA). A summary of survey activities is provided below.

3.1 Visual Assessment

Survey activities were initiated with visual observation of the subject roofs to identify HAs of suspect ACM. A HA consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application.

3.2 Physical Assessment

A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

3.3 Sample Collection

Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each HA. Bulk samples were collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content.

Terracon collected a total of 65 bulk samples from nine (9) total homogeneous areas of suspect ACM pertaining to the subject roofs. A summary of suspect ACM samples collected during the survey is included as Appendix B.

June 29, 2020 ■ Terracon Project No. N1197462

Responsive ■ Resourceful ■ Reliable 3

3.4 Sample Analysis

Bulk samples were submitted under chain of custody to EMSL Analytical Inc. (EMSL) in Indianapolis, Indiana for analysis by PLM with dispersion staining techniques per USEPA methodology 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. EMSL is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), accreditation number 200188-0. See Appendix C for the laboratory’s analytical report.

4.0 REGULATORY OVERVIEW

The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. All friable ACM is considered regulated asbestos containing material (RACM).

The asbestos NESHAP regulation classifies ACM as either RACM, Category I non-friable ACM or Category II non-friable ACM. RACM includes all friable ACM, along with Category I and Category II non-friable ACM that has become friable, will be or has been subjected to sanding, grinding, cutting or abrading, or ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity.

Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as: cement pipes, cement siding, cement panels, glazing, mortar and grouts.

In Kentucky, the federal NESHAP regulation has been delegated to the state EPA and is administered under 401 Kentucky Administrative Regulation (KAR) 58:025. The Kentucky Department for Environmental Protection (DEP), Division for Air Quality (DAQ) is responsible for administering and enforcing the federal and state NESHAP regulations as well as administering accreditations for asbestos professionals. NESHAP prior abatement (for friable removal) and prior demolition notifications are sent to the regional state EPA office. NESHAP prior abatement notifications, where >160 square feet or 260 linear feet of friable ACM is removed, and prior demolition notifications must be submitted to the DAQ office 10 business days prior to project commencement. The Kentucky local regional DAQ office for the subject site is the Frankfort office; 300 Sower Blvd Frankfort, KY 40601; telephone (502-564-3358); contact Ms. Natasha Parker (Natasha.Parker@ky.gov).

June 29, 2020 ■ Terracon Project No. N1197462

Responsive ■ Resourceful ■ Reliable 4

The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The USOSHA standard requires that employee exposure to airborne asbestos must not exceed 0.1 fibers per cubic centimeter of air (0.1 f/cc) as an eight-hour time weighted average (TWA) and not exceed

1.0 fibers per cubic centimeter of air (1.0 f/cc) over a 30-minute time period known as an excursion limit (EL). The TWA and EL are known as USOSHA’s asbestos permissible exposure limits (PELs). The USOSHA standard classifies construction and maintenance activities which could disturb ACM, and specifies work practices and precautions which employers must follow when engaging in each class of regulated work.

5.0 FINDINGS AND RECOMMENDATIONS

Based on the results of laboratory analysis, the following material was confirmed to contain asbestos.

ACM Description Location(s) % & Type Asbestos

Estimated Quantity*

Black/Silver Roof Coating Material Roof Section “Y” at Platforms for Former Apparent Duct Penetrations

(<1% Chrysotile Asbestos)

~75 Total Square Feet

*The estimated quantity listed above is based on a cursory field evaluation, and actual quantities may vary significantly, especially if ACMs are present in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document and contractors would be responsible for drawing their own conclusions on quantities present

See Appendix E diagrams for section “Y” locations. A photo example of the above-identified material is included in Appendix F.

Given that the material was identified by laboratory analysis to contain <1% asbestos, it is not regulated under the federal and state EPA NESHAP regulation; however, the material is regulated under OSHA given an airborne exposure potential exists to workers if disturbed.

If the above-identified ACM will be impacted by the roof repair/replacement project, it will need to be properly addressed in accordance with OSHA asbestos regulations, as well as the VAMC’s project specifications.

It should be noted that inaccessible/concealed suspect materials, other than those identified during this survey, may exist. Should additional suspect materials be uncovered prior to or during the renovation activities, those materials must be assumed asbestos-containing until sampled by a state-accredited inspector and analysis refutes the positive assumption.

6.0 LIMITATIONS/GENERAL COMMENTS

Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas which may pose a health or safety

June 29, 2020 ■ Terracon Project No. N1197462

Responsive ■ Resourceful ■ Reliable 5 risk to Terracon personnel were not sampled. Sampling did not include suspect materials which could not be safely reached with available ladders/man-lifts. Inaccessible/concealed suspect materials, other than those identified during this survey, may exist. Should additional suspect materials be uncovered prior to or during the demolition activities, those materials must be assumed asbestos-containing until sampled by a state-accredited inspector and analysis can confirm or deny their asbestos content.

This asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was conducted and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by the Client for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding ACM quantities present and any further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third-parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.

APPENDIX A

Project: Repair Roofing Building 1 and 1A

VA Project No.: 596A4-20-101 Lexington VA Medical Center

1101 Veterans Drive, Lexington, Kentucky Terracon Project No. N1197462

IDENTIFIED ASBESTOS-CONTAINING MATERIALS BY HOMOGENEOUS AREA (HA)

HA No. Material Description Material Location % and Type Asbestos

Federal EPA NESHAP Classification Condition Estimated

Quantity*

09 Black/Silver Roof Coating Material

Roof Section “Y” at Platforms for Former Apparent Duct Penetrations <1% Chrysotile

Not Regulated under NESHAP (contains <1% asbestos) Good

75 Total Square Feet

See Appendix E diagrams for section “Y” locations. A photo example of the above-identified material is included in Appendix F.

*Estimated quantities are based on a cursory field evaluation, and actual quantities may vary significantly, especially if ACMs are present in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document; estimates are provided for information purposes only, and contractors are responsible for determining their own opinion of quantities present.

The materials listed in this table have been sampled and determined to contain asbestos. When disturbed, various federal, state and local regulations apply. Until removed, these materials should be monitored for damage over time and repaired as necessary by appropriately trained personnel. Removal may be necessary before renovations and in most cases before a demolition. See Appendix B for a summary of samples collected. See Appendix C for detailed analytical results.

June 29, 2020 ■ Terracon Project No. N1197462

APPENDIX B

ABESTOS SURVEY SAMPLE SUMMARY

Sample # Sample Material

Description Sample Location HA Location(s) Results (% / Type of Asbestos)

HA # SEQ. #

01 01

Roofing (ISO Foam, Wood Fiber Board, and Modified Bitumen Rolled Roof)

East End, South Side

Roof O

None Detected (ND)

01 02 East End, North Side ND

01 03 East End

Roof I

ND

01 04 West End ND

01 05 North End

Roof K

ND

01 06 South End ND

02 07 Roofing (Lightweight Concrete and Modified Bitumen Rolled Roof)

South End, Southeast Corner

Roof Z

ND

02 08 South End, Southwest Corner ND

01 09 Roofing (ISO Foam, Wood Fiber Board, and Modified Bitumen Rolled Roof)

North Side

Roof M

ND

01 10 Southwest Corner ND

02 11

Roofing (Lightweight Concrete and Modified Bitumen Rolled Roof)

South End, West Side Roof Z ND

02 12 East End Roof T ND

02 13 South End, East

Side

Roof Z

ND

02 14 West End, South Side ND

02 15 West End, South Side ND

June 29, 2020 ■ Terracon Project No. N1197462

Sample # Sample Material Description Sample Location HA Location(s) Results (% / Type of Asbestos)

HA # SEQ. #

02 16

Roofing (Lightweight Concrete and Modified Bitumen Rolled Roof)

North End, Southwest Corner

Roof Z

ND

02 17 North End, Southeast Corner ND

02 18 North End, Northeast Corner ND

02 19 North End, Northwest Corner ND

02 20 South End, Northwest Corner

Roof AA

ND

02 21 South End, North Side ND

02 22 South End, Southwest Corner ND

02 23 South End, Southeast Corner ND

02 24 South End, East Side ND

02 25 South End, East Side

ND

02 26 North End, Southeast Corner ND

02 27 North End, Northeast Corner ND

02 28 North End, North Side ND

02 29 North End, Southwest Corner ND

02 30 North End, West Side ND

02 31 Middle of Roof Roof Y ND

June 29, 2020 ■ Terracon Project No. N1197462

Sample # Sample Material Description Sample Location HA Location(s) Results (% / Type of Asbestos)

HA # SEQ. #

02 32 Northeast Corner ND

02 33 Southeast Corner ND

02 34

Roofing (Lightweight Concrete and Modified Bitumen Rolled Roof)

South Side, Middle

Roof Y

ND

02 35 West End, West Side ND

02 36 West End, East Side ND

02 37 South End

Roof V

ND

02 38 Middle of Roof ND

02 39 North End ND

02 40 North End Roof P ND

01 41

Roofing (ISO Foam, Wood Fiber Board, and Modified Bitumen Rolled Roof)

North End

Roof X

ND

01 42 South End ND

01 43 North End

Roof J

ND

01 44 South End ND

03 45

Roof Flashing

North End

Roof V

ND

03 46 Northeast Corner ND

03 47 Southeast Corner ND

June 29, 2020 ■ Terracon Project No. N1197462

Sample # Sample Material Description Sample Location HA Location(s) Results (% / Type of Asbestos)

HA # SEQ. #

Flashing Caulk (Red)

North End

Roof V

ND

49 Northeast Corner ND

50 Southeast Corner ND

05 51

Roof Flashing

West End, Bottom of Large Vent

Roof Y

ND

05 52 Northeast Corner, Bottom of Duct ND

05 53 Southeast Corner, Bottom of Duct ND

06 54

Grey/Black Duct Caulking

Northwest Corner Duct

Roof Y, Bottom of Duct on Metal

Skirt

ND

06 55 Northeast Corner Duct ND

06 56 Southeast Corner Duct ND

07 57

White Vent Caulking

Middle of Roof

Roof Y, On Pipe Vents

ND

07 58 Middle of Roof ND

07 59 Middle of Roof ND

08 60

Yellow/Brown Caulking

Northwest Corner of Steel

Roof Y, On Steel Around Ductwork

ND

08 61 Southwest Corner of Steel ND

08 62 Southeast Corner of Steel ND

09 63 Black/Silver Coating Northwest Corner Duct Platform

Roof Y, At Former Duct <1% Chrysotile

June 29, 2020 ■ Terracon Project No. N1197462

Sample # Sample Material Description Sample Location HA Location(s) Results (% / Type of Asbestos)

HA # SEQ. #

09 64 Southwest Corner Duct Platform

Penetrations (Platforms) which have now been capped

<1% Chrysotile

09 65 Northeast Corner Duct Platform <1% Chrysotile

June 29, 2020 ■ Terracon Project No. N1197462

APPENDIX C

ASBESTOS LABORATORY ANALYTICAL DATA

EMSL Analytical, Inc.

6340 CastlePlace Dr. Indianapolis, IN 46250

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Attention: Phone:Josh Vogel (513) 321-5816

Fax:Terracon Consultants, Inc. (513) 321-0294

Received Date:611 Lunken Park Drive 06/22/2020 9:15 AM

Analysis Date:Cincinnati, OH 45226 06/26/2020 - 06/27/2020

Collected Date:

Project: Lexington VA Hospital N1197462

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

01-01-Roofing

162012007-0001

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof O - East End, South Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-01-Insulation

162012007-0001A

None DetectedPerlite

Non-fibrous (Other)

10%

5%

Cellulose85%Brown

Fibrous

Homogeneous

Roof O - East End, South Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-01-Foam

162012007-0001B

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof O - East End, South Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-01-Fiberboard

162012007-0001C

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof O - East End, South Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-01-Felt

162012007-0001D

None DetectedNon-fibrous (Other)10%Cellulose

Glass

80%

10%

Gray

Fibrous

Homogeneous

Roof O - East End, South Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-02-Roofing

162012007-0002

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof O - East End, North Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-02-Foam

162012007-0002A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof O - East End, North Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-02-Fiberboard

162012007-0002B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof O - East End, North Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

Initial report from: 06/29/2020 08:57:25

Page 1 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

01-02-Tar

162012007-0002C

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof O - East End, North Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-02-Mastic

162012007-0002D

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof O - East End, North Side - Roofing

(ISO Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-03-Roofing

162012007-0003

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof I - East End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-03-Foam

162012007-0003A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof I - East End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-03-Fiberboard

162012007-0003B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof I - East End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-03-Tar

162012007-0003C

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof I - East End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-03-Mastic

162012007-0003D

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof I - East End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-04-Roofing

162012007-0004

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof I - West End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-04-Foam

162012007-0004A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof I - West End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-04-Fiberboard

162012007-0004B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof I - West End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-04-Tar

162012007-0004C

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof I - West End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

Page 2 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

01-04-Mastic

162012007-0004D

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof I - West End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-05-Roofing

162012007-0005

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof K - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-05-Insulation

162012007-0005A

None DetectedPerlite

Non-fibrous (Other)

10%

5%

Cellulose85%Brown

Fibrous

Homogeneous

Roof K - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-05-Foam

162012007-0005B

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof K - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-05-Paper

162012007-0005C

None DetectedNon-fibrous (Other)5%Cellulose

Glass

90%

5%

Brown

Fibrous

Homogeneous

Roof K - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-05-Tar

162012007-0005D

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof K - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-05-Mastic

162012007-0005E

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof K - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-06-Roofing

162012007-0006

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof K - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-06-Foam

162012007-0006A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof K - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-06-Fiberboard

162012007-0006B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof K - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-06-Paper

162012007-0006C

None DetectedNon-fibrous (Other)5%Cellulose

Glass

90%

5%

Brown

Fibrous

Homogeneous

Roof K - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-06-Tar

162012007-0006D

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof K - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

Page 3 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

01-06-Mastic

162012007-0006E

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof K - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

02-07-Roofing

162012007-0007

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-07-Concrete

162012007-0007A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-08-Roofing

162012007-0008

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-08-Concrete

162012007-0008A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

01-09-Roofing

162012007-0009

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof M - North Side -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-09-Foam

162012007-0009A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof M - North Side -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-09-Fiberboard

162012007-0009B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof M - North Side -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-09-Paper

162012007-0009C

None DetectedNon-fibrous (Other)5%Cellulose

Glass

90%

5%

Brown

Fibrous

Homogeneous

Roof M - North Side -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-09-Felt

162012007-0009D

None DetectedNon-fibrous (Other)10%Cellulose

Glass

80%

10%

Gray

Fibrous

Homogeneous

Roof M - North Side -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-10-Roofing

162012007-0010

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof M - South West

Corner - Roofing (ISO

Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

Page 4 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

01-10-Foam

162012007-0010A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof M - South West

Corner - Roofing (ISO

Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-10-Fiberboard

162012007-0010B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof M - South West

Corner - Roofing (ISO

Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

01-10-Felt

162012007-0010C

None DetectedNon-fibrous (Other)10%Cellulose

Glass

80%

10%

Gray

Fibrous

Homogeneous

Roof M - South West

Corner - Roofing (ISO

Foam, Wood

Fiberboard, and

Modified Bitumen

Rolled Roof)

02-11-Roofing

162012007-0011

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, West Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-11-Concrete

162012007-0011A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, West Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-12-Roofing

162012007-0012

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof T - East End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-12-Concrete

162012007-0012A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof T - East End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-13-Roofing

162012007-0013

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-13-Concrete

162012007-0013A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-14-Roofing

162012007-0014

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - West End, South Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-14-Concrete

162012007-0014A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - West End, South Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

Page 5 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

02-15-Roofing

162012007-0015

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - West End, North Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-15-Felt

162012007-0015A

None DetectedNon-fibrous (Other)85%Glass15%Black

Fibrous

Homogeneous

Roof Z - West End, North Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-15-Concrete

162012007-0015B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - West End, North Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-16-Roofing

162012007-0016

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - North End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-16-Concrete

162012007-0016A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - North End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-17-Roofing

162012007-0017

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - North End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-17-Concrete

162012007-0017A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - North End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-18-Roofing

162012007-0018

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - North End, North East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-18-Concrete

162012007-0018A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - North End, North East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-19-Roofing

162012007-0019

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - North End, North West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

Page 6 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

02-19-Concrete

162012007-0019A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - North End, North West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-20-Roofing

162012007-0020

None DetectedNon-fibrous (Other)98%Glass2%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, North West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-20-Felt

162012007-0020A

None DetectedNon-fibrous (Other)70%Glass30%Black

Fibrous

Homogeneous

Roof Z - South End, North West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-20-Concrete

162012007-0020B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, North West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-21-Roofing

162012007-0021

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, North Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-21-Felt

162012007-0021A

None DetectedNon-fibrous (Other)70%Glass30%Black

Fibrous

Homogeneous

Roof Z - South End, North Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-21-Concrete

162012007-0021B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, North Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-22-Roofing

162012007-0022

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-22-Felt

162012007-0022A

None DetectedNon-fibrous (Other)70%Glass30%Black

Fibrous

Homogeneous

Roof Z - South End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-22-Concrete

162012007-0022B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

Page 7 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

02-23-Roofing

162012007-0023

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-23-Felt

162012007-0023A

None DetectedNon-fibrous (Other)70%Glass30%Black

Fibrous

Homogeneous

Roof Z - South End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-23-Concrete

162012007-0023B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-24-Roofing

162012007-0024

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof Z - South End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-24-Felt

162012007-0024A

None DetectedNon-fibrous (Other)70%Glass30%Black

Fibrous

Homogeneous

Roof Z - South End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-24-Concrete

162012007-0024B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Z - South End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-25-Roofing

162012007-0025

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof AA - South End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-25-Felt

162012007-0025A

None DetectedNon-fibrous (Other)70%Glass30%Black

Fibrous

Homogeneous

Roof AA - South End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-25-Concrete

162012007-0025B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - South End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-26-Roofing

162012007-0026

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof AA - North End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-26-Felt

162012007-0026A

None DetectedNon-fibrous (Other)70%Glass30%Black

Fibrous

Homogeneous

Roof AA - North End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

Page 8 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

02-26-Concrete

162012007-0026B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - North End, South East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-27-Roofing

162012007-0027

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof AA - North End, North East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-27-Concrete

162012007-0027A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - North End, North East Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-28-Roofing

162012007-0028

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof AA - North End, North Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-28-Concrete

162012007-0028A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - North End, North Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-29-Roofing

162012007-0029

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof AA - North End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-29-Roofing

162012007-0029A

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

Roof AA - North End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-29-Concrete

162012007-0029B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - North End, South West Corner -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-30-Roofing

162012007-0030

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof AA - North End, West Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-30-Felt

162012007-0030A

None DetectedNon-fibrous (Other)70%Glass30%Black

Fibrous

Homogeneous

Roof AA - North End, West Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

Page 9 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

02-30-Concrete

162012007-0030B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - North End, West Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-31-Roofing

162012007-0031

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

Roof AA - Middle of

Roof - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-31-Concrete

162012007-0031A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - Middle of

Roof - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-32-Roofing

162012007-0032

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

Roof AA - North East

Corner - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-32-Roofing

162012007-0032A

None DetectedNon-fibrous (Other)90%Glass10%Black

Fibrous

Heterogeneous

Roof AA - North East

Corner - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-32-Concrete

162012007-0032B

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - North East

Corner - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-33-Roofing

162012007-0033

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof AA - South East

Corner - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-33-Concrete

162012007-0033A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof AA - South East

Corner - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-34-Roofing

162012007-0034

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

Roof Y - South Side, Middle - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-34-Concrete

162012007-0034A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Y - South Side, Middle - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-35-Roofing

162012007-0035

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

Roof Y - West End, West Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-35-Concrete

162012007-0035A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Y - West End, West Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

Page 10 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

02-36-Roofing

162012007-0036

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

Roof Y - West End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-36-Concrete

162012007-0036A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof Y - West End, East Side - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-37-Roofing

162012007-0037

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof V - South End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-37-Concrete

162012007-0037A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof V - South End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-37-Tar

162012007-0037B

None DetectedNon-fibrous (Other)100%Black

Non-Fibrous

Homogeneous

Roof V - South End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-38-Roofing

162012007-0038

None DetectedNon-fibrous (Other)95%Glass5%Black

Non-Fibrous

Homogeneous

Roof V - Middle of

Roof - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-38-Concrete

162012007-0038A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof V - Middle of

Roof - Roofing

(Lightweight Concrete and Modified Bitumen

Rolled Roof)

02-39-Roofing

162012007-0039

None DetectedNon-fibrous (Other)98%Glass2%Gray/Black

Non-Fibrous

Homogeneous

Roof V - North End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-39-Concrete

162012007-0039A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof V - North End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-40-Roofing

162012007-0040

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof P - North End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

02-40-Concrete

162012007-0040A

None DetectedNon-fibrous (Other)100%Gray

Non-Fibrous

Homogeneous

Roof P - North End -

Roofing (Lightweight

Concrete and

Modified Bitumen

Rolled Roof)

01-41-Roofing

162012007-0041

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof X - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

Page 11 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

01-41-Foam

162012007-0041A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof X - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-41-Fiberboard

162012007-0041B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof X - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-41-Felt

162012007-0041C

None DetectedNon-fibrous (Other)5%Cellulose

Glass

90%

5%

Gray

Fibrous

Homogeneous

Roof X - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-42-Roofing

162012007-0042

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof X - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-42-Foam

162012007-0042A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof X - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-42-Fiberboard

162012007-0042B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof X - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-42-Felt

162012007-0042C

None DetectedNon-fibrous (Other)5%Cellulose

Glass

90%

5%

Gray

Fibrous

Homogeneous

Roof X - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-43-Roofing

162012007-0043

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof J - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-43-Foam

162012007-0043A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof J - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-43-Fiberboard

162012007-0043B

None DetectedNon-fibrous (Other)5%Cellulose95%Brown

Fibrous

Homogeneous

Roof J - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-43-Felt

162012007-0043C

None DetectedNon-fibrous (Other)5%Cellulose

Glass

90%

5%

Gray

Fibrous

Homogeneous

Roof J - North End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-44-Roofing

162012007-0044

None DetectedNon-fibrous (Other)95%Glass5%Gray/Black

Non-Fibrous

Homogeneous

Roof J - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

Page 12 of 15ASB_PLM_0008_0001 - 1.78 Printed: 6/29/2020 8:57 AM

Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com

162012007EMSL Order:

Customer ID: HCNU50

Customer PO: N1197462

Project ID:

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

01-44-Foam

162012007-0044A

None DetectedNon-fibrous (Other)100%Yellow

Non-Fibrous

Homogeneous

Roof J - South End -

Roofing (ISO Foam, Wood Fiberboard, and Modified Bitumen

Rolled Roof)

01-44-Fiberboard

162012007-0044B

None DetectedNon-fibrous…

This is the start of the file's text. The full file is on GovTribe.