36C24919Q0080 0002 36C24919Q0080 0002.docx

View the file

Other files

File Type Posted
36C24919C0077-000.docx DOCX document
36C24919Q0080-0005001.xlsx XLSX spreadsheet
36C24919Q0080-0005000.docx DOCX document
36C24919Q0080-0004001.pdf PDF
36C24919Q0080-0004000.docx DOCX document
36C24919Q0080-0003001.pdf PDF
36C24919Q0080-0003000.docx DOCX document
36C24919Q0080_0001.docx DOCX document
Fire_Extinguisher_Breakdown.pdf PDF
36C24919Q0080.docx DOCX document
WD_15-4673_(Rev.-8)_12-26-2018.pdf PDF
36C24919Q0080_3.docx DOCX document
36C24919Q0080_2.docx DOCX document
36C24919Q0080_1.docx DOCX document
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5. PROJECT NUMBER (if applicable)

CODE

7. ADMINISTERED BY

2. AMENDMENT/MODIFICATION NUMBER

CODE

6. ISSUED BY

8. NAME AND ADDRESS OF CONTRACTOR

4. REQUISITION/PURCHASE REQ. NUMBER

3. EFFECTIVE DATE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED

PAGE OF PAGES

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED

BPA NO.

1. CONTRACT ID CODE

FACILITY CODE

CODE

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

E. IMPORTANT:

is extended,

(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.

12. ACCOUNTING AND APPROPRIATION DATA

(REV. 11/2016)

is required to sign this document and return ___________ copies to the issuing office.

is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

15C. DATE SIGNED

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER

Contractor

16C. DATE SIGNED

14. DESCRIPTION OF AMENDMENT/MODIFICATION

16B. UNITED STATES OF AMERICA

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER

16A. NAME AND TITLE OF CONTRACTING OFFICER

15B. CONTRACTOR/OFFEROR

STANDARD FORM 30

PREVIOUS EDITION NOT USABLE

Prescribed by GSA - FAR (48 CFR) 53.243 (Type or print) (Type or print) (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

(Number, street, county, State and ZIP Code) (If other than Item 6) (Specify type of modification and authority) (such as changes in paying office, appropriation date, etc.)

(If required)

(SEE ITEM 11)

(SEE ITEM 13)

(X)

CHECK

ONE

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

(Signature of person authorized to sign) (Signature of Contracting Officer) 01-16-2019 614-19-1-5082-0002 None 90C Department of Veterans Affairs Network Contracting Office 9 1639 Medical Center Parkway Suite 400 Murfreesboro

TN

37129 90C Department of Veterans Affairs Network Contracting Office - 9 1639 Medical Center Parkway Suite 400 Murfreesboro

TN

37129 To all Offerors/Bidders

36C24919Q0080 01-09-2019

X X X

614-3690162-5082-850300-2542 0100401X1 The purpose of this amendment is to provide a revised Statement of Work (SOW) adding the monthly inspection, testing, and maintenance of the VAMC Memphis facilities emergency exit signs.

Revised SOW is included in this amendment.

Craig S. Ziegemeier

CONTINUATION PAGE

STATEMENT OF WORK

VAMC Memphis Portable Fire and Systems Extinguishers, and Emergency Exit Sign Inspection, Testing and Maintenance

INTRODUCTION: In order to ensure that they are available and operate properly when needed, both federal certification requirements and state licensure requirements mandate that healthcare facilities properly inspect, test, and maintain their portable fire extinguishers and emergency exit signs.

SCOPE OF WORK:

This Statement of Work (SOW) provides for inspection, testing and maintenance for all portable fire extinguishers and extinguishing systems utilized at VAMC Memphis facilities and vehicles. The Contractor shall furnish all supervision, licensed personnel, equipment, tools, labor, materials, parts, transportation and waste disposal necessary to perform the required work for 769 fire extinguishers. The Contractor shall repair or replace at Contractor's expense portable fire extinguishers as part of normal maintenance. The following shall be included, but not limited to, with the repair: O-rings, valve stems, gauges, hose bands and clips, and all other portable fire extinguisher components shall be covered under this contract. The work shall be performed in accordance with the National Fire Protection Association (NFPA) and this SOW and shall be subject to the terms and conditions of this contract. The fire extinguishers shall be serviced in a manner, which ensures their serviceability in case their use is required and which prevents them from deteriorating in value and functionality.

Additionally, this SOW provides for monthly inspection, testing and maintenance for all emergency exit signs at VAMC Memphis facilities. The Contractor shall furnish all supervision, licensed personnel, equipment, tools, labor, materials, parts, transportation and waste disposal necessary to perform the required work for 875 emergency exit signs. The Contractor shall repair or replace at Contractor's expense emergency exit signs as part of normal maintenance. The work shall be performed in accordance with the National Fire Protection Association (NFPA) and this SOW and shall be subject to the terms and conditions of this contract.

If commercial warranty is applicable to services and supplies being furnished under this contract, one copy of the warranty will accompany the services and supplies at the time of delivery. Said warranty shall be in addition to the rights conferred on the Government by this contract and to the extent, said commercial warranty restricts or conflicts with any clauses, terms, or conditions of this contract, the contract shall take precedence over the commercial warranty.

The Contractor may furnish advice and recommendations on necessary repairs, testing, and replacement parts required by this contract.

The contractor shall provide the name of the person responsible for the performance of work (point of contact). The name of this person and an alternate(s) shall be designated in writing to the COR (Contracting Officer Representative) or duly authorized representative. The contractor shall provide the COR a copy of the persons responsible for the performance of work.

Quantity
Size
Type
Class
91
2.5 lbs.
Dry Chemical
ABC
125
5 lbs.
Dry Chemical
ABC
81
6 lbs.
Dry Chemical
ABC
382
10 lbs.
Dry Chemical
ABC
2
20 lbs.
Dry Chemical
ABC
3
2.5 lbs.
Dry Chemical
BC
10
5 lbs.
CO
BC
4
10 lbs.
CO
BC
13
15 lbs.
CO
BC
8
5 lbs.
Dry Chemical
BC
1
10 lbs.
Dry Chemical
BC
2
5 lbs.
Halotron
BC
2
10 lbs.
Halotron
BC
3
13 lbs.
FE36
ABC
6
1 GA
Wet Chemical
K
5
1.5 GA
Wet Chemical
K
3
2.5 GA
Wet Chemical
K
1
4 GA
Wet Chemical
K
2
6 GA
Wet Chemical
K
13
6L
Wet Chemical
K
9
2.5 GA
Water
AC
1
44 lbs.
Clean Agent Sys
1
99 lbs.
Clean Agent Sys
1
10 lbs.
Dry Chemical sys

SERVICES TO BE PERFORMED:

Maintenance, Inspection and Testing

Contractor will complete the 5-year hydrostatic testing, 6-year maintenance and 12-year hydrostatic testing for all of VAMC Memphis fire extinguishers. No maintenance or testing will be done for the Nonconnah and Jackson clinics.

Portable fire extinguishers must be inspected monthly per 1910.157 (e) (2). The inspection should assure that:

1. Fire extinguishers are in their assigned place.

2. Fire extinguishers are not blocked or hidden.

3. Fire extinguishers are mounted in accordance with NFPA Standard No. 10 (Portable Fire Extinguisher).

4. Pressure gauges show adequate pressure (CO2 extinguisher must be weighed to determine if leakage has occurred).

5. Pin and seals are in place.

6. Fire extinguishers show no visual sign of damage or abuse.

7. Nozzles are free of blockage, leakage, or corrosion.

8. Fire Extinguishers and cabinets are cleaned (free of dust).

Inspections: Fire extinguishers shall be inspected, tested and maintained as required by the latest edition of NFPA 10 Chapter 7 and 8 and all inspections and testing accomplished by the contractor shall be performed by personnel with knowledgeable expertise in these fields. Extinguisher system shall be inspected, tested and maintained as required by the latest edition of NFPA 96 Chapter 11 and all inspections and testing accomplished by the contractor shall be performed by personnel with knowledgeable expertise in these fields. Inspection shall be conduct at a minimum of 30-day interval for the monthly.

The inspection will be completed using VAMC Memphis bar code system. VAMC Memphis will provide the bar code scanner. Contracting Officer's Representative (COR) will update the bar code system at the end of each day an inspection is performed.

Emergency exit signs shall be inspected, tested and maintained as required by the latest edition of NFPA 101 and 7.10.9.1, and all inspections and testing accomplished by the contractor shall be performed by personnel with knowledgeable expertise in this field. Inspections shall be conducted at a minimum of 30-day interval for the month.

Documentation of the monthly inspections must record the month, day and year of the inspection. COR will run a complete report on the last day of inspection to be certified by the contractor inspector.

Annual Maintenance: Fire extinguishers shall be subjected to maintenance at intervals of not more than 1 year, at the time of hydrostatic test, or when specifically indicated by an inspection or electronic notification. Stored-pressure types containing a loaded system agent shall be disassembled on an annual basis and subjected to complete maintenance. A conductivity test shall be conducted annually on all carbon dioxide hose assemblies. Hose assemblies found to be nonconductive shall be replaced. Pressure regulators provided with wheeled-type fire extinguishers shall be tested for outlet static pressure and flow rate in accordance with manufacturer's instructions. A thorough and yearly check of the extinguisher will ensure that the extinguisher will operate effectively and safely.

Maintenance procedures shall include a thorough examination of the three basic elements of a fire extinguisher:

a. Mechanical parts

b. Extinguisher agent

c. Expelling means

Seals or Tamper Indicators. At the time of the maintenance, the tamper seal of rechargeable fire extinguishers shall be removed by operating the pull pin or locking device. After the applicable maintenance procedures are completed, a new tamper seal shall be installed.

Six (6) Year Maintenance: The contractor shall perform six (6) year maintenance. Every 6 years, stored-pressure fire extinguishers that require a 12-year hydrostatic test shall be emptied and subjected to the applicable maintenance procedures. The removal of the agent shall only be done using a listed halon closed recovery system. When the applicable maintenance procedures are performed during a periodic recharging or hydrostatic testing, the 6-year requirement shall begin from that date. The fire extinguishers shall be returned to full service. Extinguishers that fail the test shall be identified as having failed and returned empty.

Maintenance is to be performed in accordance with published regulations and standards.

Twelve (12) Year Maintenance: The contractor shall perform twelve (12) year maintenance to include a Hydrostatic Test of the fire extinguisher. The contractor shall attach a sticker/plate identifying pertinent information as required by the manufacturer and NFPA 10. The fire extinguishers shall be returned to full service. Extinguishers that fail the test shall be identified as having failed and returned empty. A thorough examination of fire extinguishers is intended to give maximum assurance that a fire extinguisher will operate effectively and safely. It includes a thorough examination and any necessary repair or replacement.

Extinguisher Recharge: If the extinguisher has a full charge of agent upon pickup, the Contractor shall return the extinguisher in the same condition without charge for the agent unless that agent is found to be unserviceable. All rechargeable-type fire extinguishers shall be recharged after any use or as indicated by inspection or when performing maintenance. After recharging, a leak test shall be performed on stored-pressure and self-expelling types of fire extinguishers.

Hydrostatic Testing: The contractor must have their own hydrostatic testing facility. Hydrostatic testing must be performed by trained personnel with proper test equipment and facilities and according to OSHA and NFPA 10. (Hydrostatic testing shall always include both an internal and external visual examination of the cylinder. Hydrostatic testing shall be conducted using water or some other non-compressible fluid as the test medium. Air or other gases shall not be used as the sole medium for pressure testing. All air shall be vented prior to hydrostatic testing to prevent violent and dangerous failure of the cylinder. COR shall have access to the testing facility to verify the testing is in accordance with the OSHA and NFPA standard.

Cleaning: The contractor shall perform quarterly hood cleaning for eleven (11) ansul systems. The contractor shall attach a sticker/plate identifying pertinent information as required by the manufacturer and NFPA 96. The hoods shall be returned to full service.

REPORTS: The contractor shall submit reports of all maintenance and servicing applicable. The reports shall be submitted to the COR (Contracting Officer Representative) for this contract. The reports shall include a record of conditions found, repairs, recharging, and all replacement parts utilized. All records, documents, and associated papers generated during the period of the contract become government property and will be returned to the government upon contraction termination or completion. During the contract period all records, documents, and associate papers will be available for Government review.

ENVIRONMENTAL PROTECTION: The contractor shall ensure that the purchase, use, handling, storage, and disposal of all toxic, hazardous and special materials and waste are in accordance with federal, state, and local environmental protection regulations.

QUALITY CONTROL: The contractor shall develop and maintain a quality program to ensure maintenance and repair services are performed in accordance with NFPA 10, NFPA 101, NFPA 7.10.9.1, and other applicable standards, and the fire extinguisher and emergency exit sign manufacturer's instructions.

HOURS OF OPERATION: The contractor will perform services required during the hours of 7:30 am - 3:30 pm, Monday through Thursday. The COR is off every other Friday. COR non-off Friday hours are 7:30 am– 3:30 pm. The contractor will contact the Fire Safety department to schedule all inspections.

U.S. LEGAL HOLIDAYS: The following is a list of U.S. Government holidays. If the holiday falls on a Saturday, the proceeding Friday is observed as the holiday; if the holiday falls on a Sunday, the following Monday is observed as the holiday.

HOUDAY DATE

New Year's DayJan 1
Martin Luther King's Birthday3rd Monday in Jan
President's Day3rd Monday in Feb
Memorial DayLast Monday in May
Independence DayJuly4
Labor Day1st Monday in Sep
Columbus Day2nd Monday in Oct
Veterans DayNov 11
Thanksgiving Day4th Thursday in Nov
Christmas DayDec 25

SECURITY/ IDENTIFICATION: The contractor's employees shall check in and out with the VA Police obtain visitor identification each day. Employees must have a valid state or government identification. Contractor identification must be worn at all times while on the premises of the VAMC Memphis. Taking of Photographs, videos, images and recording are prohibited while on VA premises; and wearing of the approved ID badge facing forward and above the waist. Smoking is prohibited on property except in designated areas. Possession of weapons is prohibited (in vehicle or on person). Enclosed containers, including tool kits, shall be subject to search. Violations of the VA regulations may result in citation answerable in the United States (Federal) District Court. Contractor employees (crew) when on VAMC Memphis grounds; shall not bring visitors into the facility; shall not bring into the facility, any form of weapons or contraband; shall not bring in any alcohol or drugs or be under the influence of alcohol/drugs; shall conduct themselves in a professional and polite manner at all times; shall not cause any disturbances in the facility, are subject to all the rules and regulations of the VAMC Memphis. Contractor personnel shall present a neat appearance and be easily recognized. Contractor shall furnish and require every on-site company employee to wear a company shirt and safety shoes. All company workers while on duty shall be identified by uniform shirt or blouse indicating the company logo. The print should be large enough to be easily read. In addition, all company staff assigned to work at the VAMC Memphis.

TRAINING: The contractors staff (those who will be on VA property working) will be required to complete the VA Privacy Training VA20939 TMS training prior to the work beginning. The contractor will either personally bring the training certificates or E-mail the certificates to the COR so they can be kept on file for one year. The TMS training located at http://vaww.infoshare.va.gov/sites/VALU/TMS/Document%20Library%20with%20Submission/Managed%20Self%20Enrollment%20(MSE)/Managed-Self-Enrollment-Direct-Links.pdf

This training is only good for one year and the contractor is responsible to ensure their staff or persons who will be working on VA property are current. Provide the COR with each employee’s printed certificate of completion from the TMS. This certificate displays the employee’s TMS User ID.

PLACE OF PERFORMANCE: Memphis VA Medical Center; 1030 Jefferson Avenue; Memphis, TN 38104 Fire Extinguishers in Building 1, 1A, 5, 6, 7, 9, 10, 1407 Union and Hazardous Waste Storage Building.

12 Ansil Systems in Buildings 1, 5, 7, and Hazardous Waste Storage Building.

1 HFC-125 Extinguishing System in Building 1 North Clinic, Memphis, TN VAMC Vehicles (Main Campus, 1407 Union and Nonconnah Blvd) Emergency Exit Signs at VAMC Memphis and North Clinic, Memphis, TN