36C24918R0402-006.pdf
PDF 397 KB Posted
- Attached to
- Project # 596A4-CSI-102 Design-Build to Renovate Areas (Site Prep) for High Tech/ High Cost Equipment.
- Solicitation number
- 36C24918R0402
About this file
36C24918R0402 S02 Siemens R-137 LD Layout.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24918C0222-000.docx | DOCX document | |
| 36C24918R0402-0002001.pdf | ||
| 36C24918R0402-0002004.dwg | DWG drawing | |
| 36C24918R0402-0002002.pdf | ||
| 36C24918R0402-0002005.dwg | DWG drawing | |
| 36C24918R0402-0002006.dwg | DWG drawing | |
| 36C24918R0402-0002003.dwg | DWG drawing | |
| 36C24918R0402-0002000.docx | DOCX document | |
| 36C24918R0402-0001002.pdf | ||
| 36C24918R0402-0001000.docx | DOCX document | |
| 36C24918R0402-0001006.dwg | DWG drawing | |
| 36C24918R0402-0001004.dwg | DWG drawing | |
| 36C24918R0402-0001007.dwg | DWG drawing | |
| 36C24918R0402-0001005.dwg | DWG drawing | |
| 36C24918R0402-0001003.pdf | ||
| 36C24918R0402-0001001.pdf | ||
| 36C24918R0402-008.pdf | ||
| 36C24918R0402-004.pdf | ||
| 36C24918R0402-009.pdf | ||
| 36C24918R0402-014.pdf | ||
| 36C24918R0402-011.pdf | ||
| 36C24918R0402-002.pdf | ||
| 36C24918R0402-005.pdf | ||
| 36C24918R0402-012.pdf | ||
| 36C24918R0402-001.docx | DOCX document | |
| 36C24918R0402-007.pdf | ||
| 36C24918R0402-003.pdf | ||
| 36C24918R0402-010.pdf | ||
| 36C24918R0402-013.xlsx | XLSX spreadsheet | |
| 36C24918R0402-000.docx | DOCX document |
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B 02/23/18
REV ROOM TITLE PER
CUSTOMER'S REQUEST
SHEET OF
1 2
DATE:
01/18/18
DRAWN BY:
J. CAPUNE
REF:
30210892
SCALE: 3/16" = 1'-0"
1800223
REFERENCE DOCUMENT - NOT FOR CONSTRUCTION
PROJECT MANAGER: TRAVIS MATTINGLY
PHONE: (859) 229-0866
EMAIL: TRAVIS.MATTINGLY@SIEMENS.COM
VA LEXINGTON #596 - LEESTOWN
2250 LEESTOWN ROAD, LEXINGTON, KY 40511
LEESTOWN YSIO RM #137 - YSIO MAX
SIEMENS
AutoCAD SHX Text
CONTROL
AutoCAD SHX Text THIS LAYOUT IS REFLECTIVE OF THE LATEST SALES CONFIGURATION. ANY CHANGES TO THIS SALES CONFIGURATION MAY REQUIRE A REVISION TO THIS PROJECT PLAN.
AutoCAD SHX Text IN THIS RECTANGULAR SHADED AREA, NOTHING CAN EXTEND BELOW THE FINISHED CEILING TO ALLOW FREE MOVEMENT OF THE CEILING X-RAY TUBE STAND.
AutoCAD SHX Text NOTE: THE CEILING X-RAY TUBE SUSPENSION RAILS HAVE BEEN LOCATED IN THIS PLAN TO MOUNT TO THE EXISTING UNISTRUT GRID LOCATION AS PROVIDED BY THE SIEMENS PROJECT MANAGER.
AutoCAD SHX Text
ORIENTATION POINT OF YSIO MAX TABLE
AutoCAD SHX Text
X-RAY TUBE SHOWN AT BOTH 45" AND 72" SID POSITIONS TO WALL STAND
AutoCAD SHX Text NEW 36" HIGH "STAND UP" CONTROL COUNTER TO BE FURNISHED AND INSTALLED BY THE CUSTOMER/CONTRACTOR.
AutoCAD SHX Text
FIN. CLG. HT.
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text
EXISTING SINK AND CABINETS TO REMAIN.
AutoCAD SHX Text
CLEARANCE LINE FOR DETECTOR INITIALIZATION AT THE IMAGING SYSTEM.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LEESTOWN
AutoCAD SHX Text
YSIO RM
AutoCAD SHX Text
AutoCAD SHX Text B
B 02/23/18
REV ROOM TITLE PER
CUSTOMER'S REQUEST
SHEET OF
2 2
DATE:
01/18/18
DRAWN BY:
J. CAPUNE
REF:
30210892
1800223
REFERENCE DOCUMENT - NOT FOR CONSTRUCTION
PROJECT MANAGER: TRAVIS MATTINGLY
PHONE: (859) 229-0866
EMAIL: TRAVIS.MATTINGLY@SIEMENS.COM
VA LEXINGTON #596 - LEESTOWN
2250 LEESTOWN ROAD, LEXINGTON, KY 40511
LEESTOWN YSIO RM #137 - YSIO MAX
SIEMENS
Authorization:
I have reviewed the below referenced plan(s) and understand and agree with the proposed room configuration and equipment arrangement. By signing below, I agree that I have the authority to sign on behalf of the customer. I have been fully informed by Siemens about the limitations (if applicable) that exist regarding the proposed equipment installation. Siemens has explained that the listed limitations may interfere with certain functions of the equipment. We agree to assume responsibility to inform employees, agents, contractors, users or any other persons handling this equipment of these limitations and will assure that the equipment is handled in compliance with these parameters.
Signature:_____________________________________________________ Date:______________________
Name Printed:__________________________________________________ Title:____________________________
AutoCAD SHX Text
EXAM RESTRICTIONS:
AutoCAD SHX Text
1) ANGLED CROSS-TABLE LATERAL EXPOSURES WITH THE X-RAY TUBE ARE ONLY POSSIBLE FROM THE FRONT SIDE OF THE TABLE.
AutoCAD SHX Text
WARNING NOTES:
AutoCAD SHX Text
1) DUE TO THE EXAM ROOM SIZE, THE LONGITUDINAL CEILING RAILS MUST BE REDUCED IN LENGTH BY APPROXIMATELY 12".
AutoCAD SHX Text
MISCELLANEOUS NOTES:
AutoCAD SHX Text
1) THE SERVICE CLEARANCE FOR INSTALLING AND SERVIICING THE YSIO MAX TABLE WILL ONLY BE POSSIBLE FROM THE HEAD END OF THE TABLE.
AutoCAD SHX Text FOR ADDITIONAL PLANNING RELATED QUESTIONS, PLEASE REFER TO TYPICAL DRAWING SET OR SIEMENS PROJECT MANAGEMENT.
AutoCAD SHX Text
ARCHITECTURAL NOTES
AutoCAD SHX Text
1) ALL PRELIMINARY EQUIPMENT LAYOUTS SUBMITTED BY SIEMENS HEALTHCARE ARE BASED ON THE RECOMMENDED SPACE NECESSARY FOR THE OPERATION AND SERVICEABILITY OF THE EQUIPMENT BEING PROPOSED. SIEMENS WILL NOT SUBMIT AN EQUIPMENT LAYOUT THAT IS NOT IN THE BEST INTEREST OF BOTH THE CUSTOMER AND SIEMENS. ALL EQUIPMENT LAYOUTS ARE BASED EITHER ON AN ACTUAL SITE SURVEY OR ARCHITECTURAL DRAWINGS SUPPLIED TO SIEMENS. SIEMENS WILL NOT BE RESPONSIBLE FOR ANY ALTERATIONS THAT ENCROACH WITHIN DESIGNATED SAFETY AND SERVICE CLEARANCE ZONES AS INDICATED ON DRAWINGS (I.E.. PIPE CHASES, VENTILATION DUCTS, CASEWORK, AND SOFFITS, ETC.) MADE BY THE CUSTOMER OR REQUIRED BY A CUSTOMER'S ARCHITECTURAL FIRM ONCE PRELIMINARY DRAWINGS HAVE BEEN SUBMITTED AND APPROVED. DO NOT ALTER ANY SPECIFICATIONS AND/OR DIMENSIONS WITHOUT CONTACTING AND RECEIVING WRITTEN CONFIRMATION FROM SIEMENS PROJECT MANAGER. 2) SIEMENS HEALTHCARE IS NOT AN ARCHITECTURAL OR ENGINEERING FIRM. DRAWINGS SUPPLIED BY SIEMENS ARE NOT CONSTRUCTION DRAWINGS. THEREFORE, THESE DRAWINGS ARE TO BE USED ONLY FOR INFORMATION TO COMPLEMENT ACTUAL CONSTRUCTION DRAWINGS AVAILABLE FROM A CUSTOMER APPOINTED ARCHITECTURAL REPRESENTATIVE OR A CUSTOMER'S ENGINEERING DESIGN GROUP. THE CUSTOMER'S ARCHITECT AND GENERAL CONTRACTOR SHALL BE ULTIMATELY RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE CODES AND PROFESSIONAL DESIGN REQUIREMENTS INCLUDING OSHA/NEC SAFETY CLEARANCE REQUIREMENTS IN ADDITION TO SIEMENS-REQUIRED SAFETY/SERVICE CLEARANCES SHOWN. 3) THE CUSTOMER IS RESPONSIBLE FOR ALL ROOM AND AREA PREPARATION COSTS, PROFESSIONAL FEES, PERMITS, REPORTS, AND INSPECTION FEES. 4) EQUIPMENT WARRANTIES, EXPRESSED OR IMPLIED ON THE PART OF SIEMENS SHALL BE CONTINGENT UPON STRICT COMPLIANCE WITH THE ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL AND RECOMMENDATIONS AND REQUIREMENTS CONTAINED IN THESE DRAWINGS, UNLESS SPECIFIED OTHERWISE. 5) ALL DIMENSIONS SHOWN ARE FROM FINISHED SURFACES UNLESS SPECIFIED OTHERWISE. 6) THIS DRAWING DOES NOT PROVIDE RADIATION SHIELDING REQUIREMENTS FOR X-RAY AND ASSOCIATED EQUIPMENT. THE CUSTOMER IS RESPONSIBLE FOR CONSULTING WITH A REGISTERED RADIATION PHYSICIST. ACTUAL PROTECTION REQUIREMENTS SHALL BE SPECIFIED BY A REGISTERED RADIATION PHYSICIST AT CUSTOMER'S ENGAGEMENT AND EXPENSE. RESPONSIBILITY FOR ALL INFORMATION AS TO THE ROOM LOCATION, USE, AND NUMBER OF ANTICIPATED EXAMINATIONS TO BE PERFORMED PER TIME PERIOD SHALL BE PROVIDED TO THE PHYSICIST BY THE CUSTOMER. THE CUSTOMER SHALL FURTHER TAKE ALL RESPONSIBILITY IN THE COMMUNICATION AND COORDINATION OF ACTIVITIES OF THE RADIATION PHYSICIST AND THE ARCHITECTURAL REPRESENTATIVE. 7) SIEMENS HEALTHCARE SHALL BE RESPONSIBLE FOR SIEMENS EQUIPMENT INSTALLATION, CALIBRATION, CONNECTION AND INSTALLATION OF SIEMENS PROVIDED CABLES. THE CUSTOMER/ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR TERMINATIONS OF CUSTOMER/ELECTRICAL CONTRACTOR-SUPPLIED CABLES TO SIEMENS EQUIPMENT. IN THE EVENT THAT SPECIFIC TRADE RULES OR LICENSE REQUIREMENTS PROHIBIT THIS, THE CUSTOMER SHALL INITIATE THE SERVICES OF APPROVED OTHER CONTRACTORS AND PAY FOR SELECTED, APPROVED PARTIES TO PERFORM THIS WORK WITH SUPERVISION PROVIDED BY SIEMENS. CALIBRATION WHEN ACCOMPLISHED OUTSIDE OF NORMAL INSTALLATION SEQUENCES DUE TO CONTRACTOR OR TRADE RULE ACTIONS OR REQUIREMENTS SHALL BE SUPPORTED BY, CHARGED TO, AND ACCEPTED BY THE CUSTOMER AS AN ADDITIONAL INSTALLATION EXPENSE. 8) THE CUSTOMER SHALL COORDINATE WITH SIEMENS PROJECT MANAGER THE LOCATIONS AND TRAVEL OF ALL ANCILLARY EQUIPMENT TO BE CEILING OR WALL MOUNTED (I.E.: O.R. LIGHTS, MEDICAL GAS COLUMNS, PHYSIOLOGICAL MONITORING INJECTORS, CRT PLATFORMS, SPRINKLER HEADS, SMOKE DETECTORS, ELECTRICAL OUTLETS, HVAC GRILLES, SPEAKERS, AND GENERAL ROOM LIGHTING, ETC.). 9) THE GENERAL CONTRACTOR/CUSTOMER SHALL BE RESPONSIBLE FOR ALL FINAL PAINT, TOUCH-UP AND ANY COSMETIC OR TRIM WORK WHICH NEEDS TO BE OR IS REQUIRED TO BE COMPLETED AFTER THE INSTALLATION OF THE SIEMENS EQUIPMENT AND ANY ASSOCIATED SUPPORT APPARATUS.
AutoCAD SHX Text
EQUIPMENT LEGEND
AutoCAD SHX Text
NO
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SMS
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
BTU/HR
AutoCAD SHX Text
DIMENSIONS (INCHES)
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
SYM
AutoCAD SHX Text
(LBS)
AutoCAD SHX Text
TO AIR
AutoCAD SHX Text W
AutoCAD SHX Text D
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
CRM
AutoCAD SHX Text
CONTROL ROOM MODULE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 4 3/4
AutoCAD SHX Text 10 1/16
AutoCAD SHX Text 3 3/16
AutoCAD SHX Text
ON CUSTOMER'S COUNTER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
IMAGING SYSTEM - KEYBOARD AND MOUSE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ON CUSTOMER'S COUNTER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
COLOR CONTROL ROOM DISPLAY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ON CUSTOMER'S COUNTER
AutoCAD SHX Text
AutoCAD SHX Text
IS
AutoCAD SHX Text
IMAGING SYSTEM CONTAINER (UNDER COUNTER)
AutoCAD SHX Text
AutoCAD SHX Text 1,468
AutoCAD SHX Text 17 3/8*
AutoCAD SHX Text 32 1/2*
AutoCAD SHX Text 27*
AutoCAD SHX Text
*INCLUDES REQUIRED CLEARANCES.
AutoCAD SHX Text
AutoCAD SHX Text
PU1
AutoCAD SHX Text POLYDOROS R80 (65 kW) GENERATOR CABINET
AutoCAD SHX Text
AutoCAD SHX Text 2,048**
AutoCAD SHX Text 31 1/2
AutoCAD SHX Text 17 1/8
AutoCAD SHX Text 86 3/4
AutoCAD SHX Text
**DURING OPERATION, 1,195 IN STANDBY MODE
AutoCAD SHX Text
AutoCAD SHX Text T1
AutoCAD SHX Text
YSIO MAX TABLE WITH MOBILE DETECTOR
AutoCAD SHX Text
AutoCAD SHX Text 2,560
AutoCAD SHX Text 94 13/16
AutoCAD SHX Text 31 1/2
AutoCAD SHX Text
AutoCAD SHX Text
***20 1/4" TO 37 9/16"
AutoCAD SHX Text
AutoCAD SHX Text
AP
AutoCAD SHX Text
ACCESS POINT (TOP OF GENERATOR)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5 1/2*A
AutoCAD SHX Text 3*B
AutoCAD SHX Text
*A 12 1/4, *B 9" INCLUDING ANTENNAE
AutoCAD SHX Text
AutoCAD SHX Text
WS
AutoCAD SHX Text
YSIO MAX WALL STAND WITH FIXED DETECTOR (RIGHT LOADING GRID)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 35*A
AutoCAD SHX Text
AutoCAD SHX Text
*A - MAX. IN HORIZONTAL POSITION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
YSIO CEILING RAILS FOR X-RAY TUBE SUSPENSION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 155 3/8
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SIZE AND WEIGHT PER RAIL
AutoCAD SHX Text
AutoCAD SHX Text
TS
AutoCAD SHX Text
3M FULLY SYNCHRONIZED BRIDGE & X-RAY TUBE STAND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 119 1/4
AutoCAD SHX Text
AutoCAD SHX Text *43
AutoCAD SHX Text
*TUBE CARRIAGE IN PARK POSITION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GRID HOLDER (WALL MOUNTED)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 21 11/16
AutoCAD SHX Text
AutoCAD SHX Text 16 9/16
AutoCAD SHX Text
LOCATED AND INSTALLED BY CUSTOMER/CONTRACTOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CHARGING STATION FOR MAX DETECTORS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 12 1/2
AutoCAD SHX Text 6 3/4
AutoCAD SHX Text
AutoCAD SHX Text
ON CUSTOMER'S COUNTER
| Sheets and Views |
| R-101-Plan(Landscape) |
| R-501-Notes(Landscape) |
File details come from the government source that posted it.