36C24827Q0127.docx

DOCX document 20 KB Posted

Attached to
6515--FY27 E14C4T TRIPLANE ENDO TRANSDUCERS INTEN TO SOLE SOURCE
Solicitation number
36C24827Q0127
Issued by

About this file

This is a Sources Sought Notice issued by the Department of Veterans Affairs Network Contracting Office 8 (NCO 8) for market research purposes. The C.W. Bill Young Veterans Medical Center Surgery Service in Bay Pines, Florida is seeking procurement of six GE Healthcare E14C4T Triplane endo transducers (Part Number 9018) and six reprocessing trays (Part Number UA2511) to replace non-functional, unrepairable ultrasound probes that have reached the end of their operational life. The required products must be delivered to Building 36 (Equipment Warehouse) no later than December 19, 2026, for ultimate placement at the Surgery Service in Building 100. This is a firm, fixed-price supply requirement with Product Service Code 6515 and NAICS Code 339112.

Responses must be submitted by November 16, 2026 at 14:00 Eastern Time via email to Michael A. Shook, the Contracting Officer, at michael.shook@va.gov. The notice indicates an intent to sole source this requirement and is targeted toward Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), Veteran-Owned Small Businesses (VOSBs), and Small Businesses (SBs). If insufficient SDVOSB responses are received, the requirement may be re-solicited as a VOSB or SB set-aside, or as unrestricted if necessary. Interested parties must submit a capability statement and supporting documentation demonstrating their ability to provide the specified triplane transrectal ultrasound transducers with integrated biopsy guidance capability, operating at 4-14 MHz frequency, compatible with BK Medical ultrasound systems, and meeting all specified imaging modes, sterilization, and safety requirements.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
FY27 E14C4T TRIPLANE ENDO TRANSDUCERS INTEN TO SOLE SOURCE

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
33744
SOLICITATION NUMBER*
36C24827Q0127
RESPONSE DATE/TIME/ZONE
11-16-2026 14:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
10 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8)

10,000 Bay Pines Blvd Bay Pines FL 33744

POINT OF CONTACT*

Michael A Shook

PLACE OF PERFORMANCE

ADDRESS
C.W. Bill Young Veterans Medical Center

10000 Bay Pines Blvd.

Bay Pines FL

POSTAL CODE
33744
COUNTRY
USA

ADDITIONAL INFORMATION

AGENCY’S URL
http://www.va.gov
URL DESCRIPTION
Department of Veterans Affairs
AGENCY CONTACT’S EMAIL ADDRESS
michael.shook@va.gov
EMAIL DESCRIPTION
Contracting Officer

DESCRIPTION

Good day, SDVOSB’s, VOSB’s & SB's Sources Sought INTENT TO SOLE SOURCE Pre-Solicitation.

This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSBs’ VOSBs’, or SBs’. This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB’s, the requirement may be solicited as a VOSB or a SB set aside, if none or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete.

Please reply in the affirmative via email if you are interested and can provide the required product/services for this requirement. Please provide your capability statement, and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of November 2026 14:00 EDT, thanks.

1. General: C.W. Bill Young Veterans Medical Center Surgery Service located at 10000 Bay Pines Blvd. Bay Pines, Fl. 33744 is seeking procurement of six transducers and six trays from GE Healthcare. The department requires replacement of ultrasound transducers that have reached the end of their operational life and can no longer be repaired or supported by the manufacturer.

2. Background: These transducers are vital to patient diagnostic and procedural imaging. The existing probes have been evaluated by Biomedical Engineering and determined to be non-functional, unrepairable, and beyond economical repair. Without replacements, the service cannot maintain adequate imaging capacity to support patient care.

2.Scope of Work: This requirement needs to provide six (P/N: 9018) E14C4T Triplane endo transducers and six (P/N:UA2511) trays.

3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 36 for Equipment.

4.Period of Performance: The product is requested to be delivered no later than December 19th.

5.Type of Contract: Supply: Firm, Fixed Price.

6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below.

6.1 Salient Characteristics

NAME BRAND - Equipment Requirement: GE Healthcare QTY. 6 - (P/N: 9018) E14C4T Triplane Endo Transducer QTY. 6 – (P/N: UA2511) Reprocessing Trays for E14C4T

Equipment Requirement:

Minimum Required Features and Specifications

1. Type / Intended Use:

a) Must be a transrectal ultrasound transducer specifically designed for prostate imaging and biopsy guidance in urology applications.

b) Must provide multi-plane (triplane) imaging capability—allowing visualization of transverse, sagittal, and end-fire planes without changing probes.

2. Frequency & Imaging Performance:

a) Must operate within a frequency range of approximately 4 MHz to 14 MHz to provide both high-resolution and deep-penetration imaging of the prostate.

b) Must support B-mode, M-mode, Color Doppler, and Power Doppler imaging modes (with optional elastography and contrast imaging if supported by the connected ultrasound system).

3. Biopsy and Procedural Capability:

a) Must include or support an integrated biopsy guide channel that allows both biplane and end-fire biopsy procedures without requiring probe exchange.

b) Must accommodate standard 17- or 18-gauge biopsy needles through compatible biopsy guide attachments.

c) Must permit real-time needle visualization during transrectal or transperineal prostate biopsy procedures.

4. Design & Ergonomics

a) Must be a compact, endocavity-style probe suitable for patient comfort and operator ergonomics during transrectal use.

b) Must include a control (“Smart”) button or equivalent for hands-free freezing, storing, or switching imaging planes directly from the probe handle.

c) Must be designed for one-handed operation and compatible with sterile probe covers.

5. Compatibility

a) Must be fully compatible with BK Medical ultrasound systems, including bk3000, bk5000, bkActiv, and bkSpecto platforms.

b) Must connect using the appropriate BK Medical proprietary connector interface without the need for modification or adapters.

6. Cleaning & Sterilization

a) Must be fully immersible and validated for standard high-level disinfection or sterilization processes used for endocavity probes.

b) Must be compatible with approved sterile covers and disinfection solutions specified in the manufacturer’s reprocessing guide.

7. Construction & Safety

a) Must be constructed of biocompatible materials suitable for internal use (per ISO 10993 or equivalent standards).

b) Must comply with applicable IEC/EN 60601-1 electrical safety and ultrasound acoustic output limits.

c) Must be supplied new, manufacturer-certified, and covered under OEM warranty for clinical use.

Summary Table

Feature Category
Requirement
Type
Triplane transrectal prostate ultrasound transducer
Frequency
4–14 MHz
Imaging Modes
B, M, Color Doppler, Power Doppler (Elastography optional)
Biopsy Capability
Integrated dual-plane biopsy guide
Needle Compatibility
17–18 G
Operation
One-handed, Smart Button on probe
Sterilization
Fully immersible, high-level disinfectable
Compatibility
bk3000, bk5000, bkActiv, bkSpecto
Intended Use
Prostate imaging and biopsy guidance
Condition
New OEM product, OEM warranty
*= Required Field
Sources Sought Notice

Sources Sought Notice

File details come from the government source that posted it. Updated .