J041--Intent to Sole Source | Calibrate Air Flow Monitoring Stations
Solicitation number
36C24826Q0097
Issued by

About this file

This is a Special Notice of Intent to Sole Source a contract to Johnson Controls for HVAC Air Flow Monitoring Station (AFMS) calibration and calculation services at VA healthcare facilities in Florida. The Department of Veterans Affairs Network Contracting Office 8 (NCO 8), located in Bay Pines, FL, intends to award this firm-fixed-price contract under FAR 6.302-1, having determined through market research that Johnson Controls is the only responsible source capable of meeting the requirements. The contract supports the Bay Pines VA Healthcare System and Lee County VA Medical Center (2489 Diplomat Parkway East, Cape Coral, FL 33909) and involves calculation and calibration services for up to 50 AFMS units and up to 175 AFMS probes, with work performed at the Lee County Health Care Clinic.

The scope of work requires the contractor to provide all supervision, materials, and labor for whole building adjustment, testing, and commissioning of the HVAC AFMS system. Specific deliverables include calculating and calibrating airflow in each Air Handling Unit (AHU) to manufacturer specifications, procuring and installing new monitoring station components (sensors, transmitter, controller, pressure transducers, temperature sensors), removing obsolete equipment, connecting the system to the existing METASYS Building Automation System for data integration, verifying proper operation in manual, auto, and bypass modes, conducting functional checks and system commissioning, configuring alarm settings, and submitting a comprehensive written report with test data and equipment operation verification. Expressions of Interest must be submitted by November 26, 2025, at 12:30 PM EST to Contracting Officer Lakiesha Anderson at lakiesha.anderson@va.gov. This notice is for market research purposes only, and the government retains discretion to conduct competitive procurement based on responses received.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Special Notice Special Notice

SUBJECT*
Intent to Sole Source | Calibrate Air Flow Monitoring Stations

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
33744
SOLICITATION NUMBER*
36C24826Q0097
RESPONSE DATE/TIME/ZONE
11-26-2025 12:30PM EASTERN TIME, NEW YORK, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
PRODUCT SERVICE CODE*
J041
NAICS CODE*
238220
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8)

10,000 Bay Pines Blvd Bay Pines FL 33744

POINT OF CONTACT*

Contracting Officer Lakiesha Anderson lakiesha.anderson@va.gov 561-618-2398

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

Network Contracting Office 8 (NCO 8) intends to make a sole source award to Johnson Controls under the authority of FAR 6.302-1, when the supplies or services required by the agency are available from only one responsible source. Market research was conducted and determined that Johnson Controls is the only vendor capable of providing supplies and services necessary to meet the requirements.

The proposed contract action is to support the Bay Pines VA Healthcare System, for the Calculation and Calibration (CaC) of up to 50 Air Flow Monitoring Stations (AFMS) and up to 175 AFMS probes. These services are required to ensure accurate airflow measurement and integration with the existing METASYS Building Automation System (BAS) installed at the Bay Pines VA Medical Center in support of the Lee County VA Medical Center, 2489 Diplomat Parkway East, Cape Coral, FL 33909. This one-time contract will be firm-fixed priced.

BRAND ONLY

GENERAL: The Contractor shall supply all supervision, materials, and labor to make the necessary Heating, Ventilation, and Air Conditioning (HVAC) Air Flow Monitoring Station (AFMS) system calculations and calibrations (CaC) to include including sensors, pickup tubes, pressure transducers, temperature sensors, and the AFMS controller, following manufacturer's specifications and best practices at the Lee County Health Care Clinic.

SCOPE: Preform a whole building adjustment, testing and commissioning to the HVAC Air flow monitoring station (AFMS) system through providing Calculation and Calibration (CaC) on up to qty 50 (Fifty) AFMS and up to 175 AFMS probes. Calculate and calibrate the airflow in each Air Handling Units (AHU) to manufactures recommendation and optimum airflow operation. Procure and install the new air flow monitoring station and its components, including sensors, transmitter, and controller. Remove old, nonfunctioning items and install the new airflow monitoring station components, including sensors, pickup tubes, pressure transducers, temperature sensors, and the AFMS controller, following manufacturer's specifications and best practices. Connect the new system to the existing METASY Building Automation System (BAS), for data collection and integration. Re-torque electrical and power connections as needed. Ensure the station and its components are compatible with the excising Building Management System (BMS) or control system. Verify proper operation of the new airflow monitoring station and its components in manual, auto, and bypass modes. Conduct functional checks prior to verify system is functioning as designed and perform system commissioning. Run tests to ensure equipment is operating according to design parameters, including safety and emergency control devices. Configure alarm settings to notify of deviations from airflow setpoints or other critical parameters. Submit a written report containing all recorded test data and proper equipment operation.

This Notice of Intent is not a request for Proposals or Quotations. No solicitation document exists, and no telephone or email inquiries will be accepted. No contract award will be made on the basis of proposals, or quotations received in response to this notice. This is strictly for market research purposes. Interested persons may identify their interest and capability to respond to the requirement and should furnish detailed data concerning their capabilities to provide supplies/services sought including pricing data and technical data sufficient enough to determine that a comparable source to the government is available.

The government may consider all Expressions of Interest (EOI) received prior to November 26, 2025, at 12:30 PM EST. A determination by the government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. Responses to this notice must be emailed to Lakiesha.anderson@va.gov using the following title in the email’s subject line: 36C24826Q0097 Calibrate Air Flow Monitoring Stations and received by 12:30PM EST on November 26,2025. Submitters are responsible for ensuring their EOI reaches the designated contracting officer on time.

See attached document: SOW Calibrate Air Flow Monitoring System.

See attached document: JA Calibrate Airflow Monitoring Station_Redacted.

*= Required Field
Special Notice

Special Notice

File details come from the government source that posted it. Updated .