36C24822Q0842 0001_1.docx

DOCX document 34 KB Posted

Attached to
J063--FY22: Surveillance Cameras Security Maintenance Services
Solicitation number
36C24822Q0842
Issued by

About this file

This is a combined synopsis and solicitation from the Department of Veterans Affairs seeking quotes for surveillance cameras security maintenance services. The solicitation is set aside for small businesses and involves preventative maintenance, repairs and operation services for integrated security electronic systems located at VA facilities in Puerto Rico and the US Virgin Islands. The contract period of performance is one year from the date of award with four one-year option periods. Quotes are due by May 27, 2022 and award will be based on a comparative evaluation of quotes considering best value to the government. The solicitation incorporates FAR provisions and clauses for commercial item acquisitions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment to a Previous Combined Solicitation Amendment to a Previous Combined Solicitation

SUBJECT*
FY22: Surveillance Cameras Security Maintenance Services

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
00921-3201
SOLICITATION NUMBER*
36C24822Q0842
RESPONSE DATE/TIME/ZONE
05-27-2022 4:30 PM EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
J063
NAICS CODE*
561621
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8) VA Caribbean HCS (Admin Bldg) #10 Calle Casia Suite #4M440 San Juan PR 00921-3201

POINT OF CONTACT*

Administrative Contracting Officer Mr. Israel Rodriguez israel.rodriguez-perez@va.gov 787-641-7582, extension 34973

DESCRIPTION

Amendment is issue to provide respond to questions.

Question 1: Will there be a site visit performed at any of the facilities? If not, we request that there is a site visit for the San Juan, Puerto Rico VA Caribbean Healthcare System (VACHS) based on the footprint of the campus and the amount of equipment listed. Janus Advisory Group, Mr. Andy Jones, President.

Answer Q1: A site visit was schedule for May 16, 2022 at 9:00 am EST. The activity was posted in SAM Contracting Opportunity on May 11, 2022.

Question 2: Are there any diagrams or drawings of the currently deployed systems? Janus Advisory Group, Mr. Andy Jones, President.

Answer Q2: There is no diagrams or drawings at this stage of the procurement. They will be available as needed in contract administration.

Question 3: Is there a current VAR of record/maintenance contract in place for the facilities? If so, may we have the information of the current incumbent providing the support? Janus Advisory Group, Mr. Andy Jones, President.

Answer Q3: At the present time the station do not have a maintenance contract in place. The station is performing maintenance, replacement of equipment and repairs as needed with micro purchase orders. The equipment will be fully operational by contract award.

Question 4: Is the current installed physical access control equipment able to read the newly issued v8.1 credentials that the VA is issuing through the USAccess program? If not, is the VA amenable to upgrades that would need to be performed as the credentials are rolled out? Janus Advisory Group, Mr. Andy Jones, President.

Answer Q4: There is currently an ongoing plan to have our system upgraded to the new v8.1. The execution will be carried out in contract administration.

Question 5: We are requesting an extension of the initial proposal due date- with this large of an equipment list (multiple technologies and vendors) and the clinic sites, we want to be able to provide as accurate and reflective of a response as possible. Janus Advisory Group, Mr. Andy Jones, President.

Answer Q5: No additional time for quote submission. The respond due date is May 27, 2022.

Question 6: What is the serial number of the CCure 800 software? Janus Advisory Group, Mr. Andy Jones, President.

Answer Q6: This will be provided to the company to whom the contract is awarded.

Question 7: When is the site visit for the upcoming project? Joint Venture with 7 Mountains, Mr. Marcus Lillard. CEO/President.

Answer Q7: A site visit was schedule for May 16, 2022 at 9:00 am EST. The activity was posted in SAM Contracting Opportunity on May 11, 2022.

Question 8: VACHS/OPA ACCESS CONTROL (1) Ccure 800 Application Software SSA it has been replaced by Ccure9000 Application Software SSA. Security Integration Group Inc, Mr. Esteban Bermudez, General Manager.

Answer Q8: Yes. Application has been replaced.

Question 9: VACHS/PHARMACY/ACCESS CONTROL OPA, (1) Ccure 800 Application Software SSA it has been replaced by Ccure9000 Application Software SSA. Security Integration Group Inc, Mr. Esteban Bermudez, General Manager.

Answer Q9: Yes. Application has been replaced.

Question 10: Ponce Access Control Pharmacy (1) Ccure 800 Application Software SSA it has been replaced by Ccure9000 Application Software SSA. Security Integration Group Inc, Mr. Esteban Bermudez, General Manager.

Answer Q10: Yes. Application has been replaced.

Question 10: Ponce OPA Clinic, (1) Ccure 800 Application Software SSA it has been replaced by Ccure9000 Application Software SSA. Security Integration Group Inc, Mr. Esteban Bermudez, General Manager.

Answer Q10: Yes. Application has been replaced.

Question 11: Could you be able to provide an equipment list to be considered for repair or replace before or during contract? It’s important to consider this since at this time the systems are not under a maintenance contract. Security Integration Group Inc, Mr. Esteban Bermudez, General Manager.

Answer Q11: The equipment is and will be fully operational by contract award. At the time of contract administration, the contractor shall maintain inventory of parts for equipment maintenance. Any part or component that is not considered part of the maintenance according to the terms of the contract, will be negotiated before being executed.

Question 12: Any additional cost to bring the system back to normal operation should be add to the proposal or shall be considered as an amendment after contract is awarded? Security Integration Group Inc, Mr. Esteban Bermudez, General Manager.

Answer Q12: The equipment will be fully operational by contract award. Any deficiency will be corrected prior to contract award. During contract administration, any work not covered under contract will be process by mutual agreement, modification of contract.

Question 13: Please verify date of site visit, I understand is May 16, not June. Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q13: The date of June 6 in the first sentence of notice is incorrect. The Site Visit was May 16, 2022; as it is clarified on the seventh and eighth sentence in conjunction with the date to submit questions.

Question 14: How many in‐house technicians are need and where? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q14: Just 1 Technician in house 3 days a week. This is Mondays, Wednesdays and Fridays. They report to the CCTV area Supervisor Security Assistant for daily task. In contract administration, any change in this condition will be negotiated and executed by mutual agreement, modification of contract.

Question 15: Please specify the location of equipment listed in OB.2 Scope or Work lines, Replacement Parts/components: items a.8. Community Living Center CCTV System, b.17. Clinics Duress Button, c.18. South Bed Tower CCTV, d.19. South Bed Tower Access Control, e.30. Administrative Building CCTV and Access Control, f.38. New Multilevel Parking CCTV and Access Control, g. 38. New Multilevel Parking CCTV and Access Control and h. 35. New Urology Area. Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q15: The location of equipment will be available at contract administration. The following is a consolidated list of equipment to be service.

VACHS Security System Inventory

VASJ and Clinics

VASJ Pharmacy

Access Control

Access Control

Device
Quantity
Device
Quantity
APC 8x
9
APC 8x
5
APC Lite
4
Lantronix 1100
2

Lantronix 1100

iSTAR Pro
1
iSTAR Pro
12
APS/PSX
6
iSTAR Ultra SE
7
Securitron/Altronix PWR
6
iSTAR Ultra ex
1
Interlock PWR
1
iSTAR Ultra Edge
72
Readers
40
APS/PSX
30
Doors
24
Securitron/Altronix PWR
107
RM-4
31
Readers
241
Ccure 9000
1
Doors
211
Elevators
8

POPC Pharmacy

i8
37

Access Control

o8
8
Device
Quantity
i32
1
APC 8x
1
RM-4
66
APC Lite
1
Panic Buttons
100
Lantronix 1100
1
APS/PSX
2

CCTV

Securitron/Altronix PWR
1
Exacq IP04-02T-R2AL-E-I2
1
Readers
10
Exacq Multilevel A (SN 4C-ED-FB-40-6C-1D)
1
Doors
5
Exacq IP02-01T-GM-A1
3
RM-4
10
Exacq IPS-2000-R2-5C
2
Ccure 9000
1
Exacq IPS04-012T-R2-G2
5
IPS04-6000-R2-G2
2

POPC Clinic

Exacq ISP04-4000-DT-H2
1

Access Control

Storage S-32TB-2U-A1
6
Device
Quantity
Multilevel B Video Edge (SN NV4062220158452)
1
APC 8x
2

Cameras

Lantronix 1100
1
Speed Dome PTZ
24
APS/PSX
2
Illustra Mini Dome
16
Securitron/Altronix PWR
2
Axis 215 PTZ
2

Readers

Axis 216MFD
17
Doors
8
Axis 241Q
8
RM-4
16
Hikvision DS-2CD2432F-IW
1
i8
4
Vivotek FD8161
2
Panic Buttons
32
Vivotek FE8182
2
Ccure 9000
1
Axis M1054
1
Axis M1065-L
57

POPC Clinic

Axis M3024-L
5

CCTV

Axis M3025
194
Device
Quantity
Axis M3045-V
23
Analog DVR 16ch
2
Axis M3046-V
3
Analog Cameras
28
Axis P3304
59
Cam PWR
2
Axis P5512-E
5
Axis Q6032-E
3

Carolina Warehouse

Axis Q6042
11

CCTV

Axis Q6042-E
6
Device
Quantity
Axis Q6052
1
Axis P3374-V
14
Axis Q6052-E
11
Axis M3048-P
16

Servers and Workstations

Axis P35624-MKII
1
Victor
1
Axis Server
1
Ccure
1
Lynx
1
Video Wall High Performance PC
4
Nurse Station Mini PC
2

Components

42" Monitor
10
Wall Flush Monitor
3
72" Network Cabinet
2
Monitor Stand
4
Windsted Desk
1
UPS Battery
1
HDMI Extender
4
Panic Bars
_
Exit Delays (XDT)
_
Doberman Siren
_
Motion detectors Comm Rooms
_
DSC Alarms
_
PIC Standalone Analog CCTV
8Cam 1 DVR

Question 16: The existing wiring runs thru a Conduit or Plenum? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q16: The wiring runs thru both systems.

Question 17: Who will be in charge for programming the system and devices, Contractor or VA personnel? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q17: The representatives of the Government and Contractor will be established in the contract document. All technical aspects will be handled by facility Police Service representative.

Question 18: Where will spare parts be stored, VA facilities or Contractors? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q18: The facility will not provide space to store inventory. That task will be the responsibility of contractor.

Question 19: How long has the existing equipment been operating? Can a list of dates be provided? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q19: The system has been in service since 2017, seven years.

Question 20: Who will be responsible for the cost when replacing equipment which is obsolete? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q20: In contract administration, all changes of term and conditions, will be negotiated and executed by mutual agreement, modification of contract.

Question 21: Does VA have an Inspection Form to follow? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q21: The station does not have any kind of guide for that purpose established. Maintenance should be executed in accordance with manufacturer standards. Contractor should develop one, if necessary.

Question 22: Are the actual systems fully operational? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q22: The equipment is and will be fully operational by contract award.

Question 23: Will the VA require an assessment of this systems prior beginning of service? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q23: No evaluation of the system is contemplating at the moment. If so, it will be established in contract document.

Question 24: Does new replacement equipment have to be the same model of existing one? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q24: Equipment must be replaced with the same brand or with another of same specification equal or higher quality in compliance with Secure Equipment Act 2021. Information must be presented for evaluation in all changes.

Question 25: Will an Escort be needed during maintenance? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q25: Only while entering restricted areas such as the IT Closets.

Question 26: Who will be responsible for damage to equipment due to electrical problems? Bonneville Contracting & Technology Group, LLC, Ms. Sandra M Chaloka.

Answer Q26: Any damage to equipment will be assessed to establish responsibility, then it will be repaired.