36C24818R0184-003.pdf

PDF 25 KB Posted

Attached to
Replace Eight Air Handlers (Construction) VA Medical Center West Palm Beach
Solicitation number
36C24818R0184
Issued by

About this file

36C24818R0184 Attachment 02 000110-TABLE OF CONTENTS.pdf

View the file

Other files

File Type Posted
36C24818R0184-A00003000.docx DOCX document
36C24818R0184-A00003002.pdf PDF
36C24818R0184-A00003005.pdf PDF
36C24818R0184-A00003001.pdf PDF
36C24818R0184-A00003006.pdf PDF
36C24818R0184-A00003003.pdf PDF
36C24818R0184-A00003004.pdf PDF
36C24818R0184-A00003007.pdf PDF
36C24818R0184-A00002000.docx DOCX document
36C24818R0184-A00002001.pdf PDF
36C24818R0184-A00001000.docx DOCX document
36C24818R0184-034.pdf PDF
36C24818R0184-012.pdf PDF
36C24818R0184-010.pdf PDF
36C24818R0184-004.pdf PDF
36C24818R0184-021.pdf PDF
36C24818R0184-025.pdf PDF
36C24818R0184-030.pdf PDF
36C24818R0184-027.pdf PDF
36C24818R0184-011.pdf PDF
36C24818R0184-006.pdf PDF
36C24818R0184-035.docx DOCX document
36C24818R0184-022.pdf PDF
36C24818R0184-005.pdf PDF
36C24818R0184-014.pdf PDF
36C24818R0184-019.pdf PDF
36C24818R0184-001.docx DOCX document
36C24818R0184-016.pdf PDF
36C24818R0184-024.pdf PDF
36C24818R0184-009.pdf PDF
36C24818R0184-026.pdf PDF
36C24818R0184-008.pdf PDF
36C24818R0184-015.pdf PDF
36C24818R0184-031.pdf PDF
36C24818R0184-029.pdf PDF
36C24818R0184-017.pdf PDF
36C24818R0184-007.pdf PDF
36C24818R0184-013.pdf PDF
36C24818R0184-028.pdf PDF
36C24818R0184-002.pdf PDF
36C24818R0184-020.pdf PDF
36C24818R0184-023.pdf PDF
36C24818R0184-033.pdf PDF
36C24818R0184-018.pdf PDF
36C24818R0184-032.pdf PDF
36C24818R0184-000.docx DOCX document
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10-01-16

REPLACE AIR HANDLERS 4, 35, 54, 55, 27, NAH1, NAH2, AND NAH3

WEST PALM BEACH VA MEDICAL CENTER

WEST PALM BEACH, FL 00 01 10-1

DEPARTMENT OF VETERANS AFFAIRS

VHA MASTER SPECIFICATIONS

TABLE OF CONTENTS

Section 00 01 10

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00 General Requirements 11-15 01 33 23 Shop Drawings, Product Data, and Samples 07-15 01 35 26 Safety Requirements 09-16 01 42 19 Reference Standards 05-16 01 57 19 Temporary Environmental Controls 01-11 01 74 19 Construction Waste Management 09-13

DIVISION 02 – EXISTING CONDITIONS

02 41 00 Demolition 02-15

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 84 00 Firestopping 02-16

DIVISION 09 – FINISHES

09 91 00 Painting 01-16

DIVISION 23 – HEATING, VENTILATING, AND AIR

CONDITIONING (HVAC)

23 05 11 Common Work Results for HVAC 02-15 23 05 12 General Motor Requirements for HVAC 11-10 23 05 41 Noise and Vibration Control for HVAC Piping and

Equipment 02-15

23 05 93 Testing, Adjusting, and Balancing for HVAC 02-15 23 07 11 HVAC Insulation 02-15 23 08 00 Commissioning of HVAC Systems 06-13 23 09 23 Direct-Digital Control System for HVAC 09-11 23 21 13 Hydronic Piping 09-12 23 31 00 HVAC Ducts and Casings 03-13 23 34 00 HVAC Fans 02-15 23 40 00 HVAC Air Cleaning Devices 02-12 23 72 00 Air-to-Air Energy Recovery Equipment 05-11 23 73 00 Indoor Central-Station Air-Handling Units 04-11 23 82 16 Air Coils 04-11

DIVISION 26 – ELECTRICAL

26 05 11 Requirements for Electrical Installations 01-16 26 05 19 Low-Voltage Electrical Power Conductors and Cables 07-13

10-01-16

REPLACE AIR HANDLERS 4, 35, 54, 55, 27, NAH1, NAH2, AND NAH3

WEST PALM BEACH VA MEDICAL CENTER

WEST PALM BEACH, FL 00 01 10-2

26 05 26 Grounding and Bonding for Electrical Systems 12-12 26 05 33 Raceway and Boxes for Electrical Systems 05-14 26 27 26 Wiring Devices 01-16 26 29 11 Motor Controllers 08-14 26 51 00 Interior Lighting 08-14

DIVISION 28 – ELECTRONIC SAFETY AND SECURITY

28 31 00 Fire Detection and Alarm 10-11